Hun-Chul Seo
Research Subjects
Hun-Chul Seo has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
- Gi-Hyeon Gwon
Department of Smart Electrical and Electronic Engineering, Yonam Institute of Technology, Jinju, Korea
4 shared publications - Keon-Woo Park
Next Square, Gunpo, Korea
2 shared publications - Keon-Woo Park
Next Square, Gunpo-si 15850, Korea
1 shared publication - Sang-Bong Rhee
Department of Electrical Engineering, Yeungnam University, Gyeongsan 38541, Republic of Korea
1 shared publication
Latest Publications
- 15 March 2024
- Published by Springer Nature in Journal of Electrical Engineering & Technology
- Vol. 19 (4) , 2767-2777
Development of New Protection System Using Direction of Fault Current in Radial-Type LVDC Distribution System with PV System
- 15 March 2024
- Published by Springer Nature in Journal of Electrical Engineering & Technology
- Vol. 19 (4) , 2767-2777
Development of New Protection System Using Direction of Fault Current in Radial-Type LVDC Distribution System with PV System
- 29 August 2022
- Published by Springer Nature in Journal of Electrical Engineering & Technology
- Vol. 18 (1) , 239-248
New Protection Method Considering Fault Section in LVDC Distribution System with PV System
- 29 August 2022
- Published by Springer Nature in Journal of Electrical Engineering & Technology
- Vol. 18 (1) , 239-248
New Protection Method Considering Fault Section in LVDC Distribution System with PV System
- Open Access
Development of New Protection Scheme in DC Microgrid Using Wavelet Transform
The demand for a low voltage direct current (LVDC) microgrid is increasing by the increase of DC-based digital loads and renewable resources and the rapid development of power electronics technology. For the stable operation of an LVDC microgrid, it is necessary to develop a protection method. In this paper, the new protection scheme considering the fault section is proposed using wavelet transform (WT) in an LVDC microgrid. The fault sections are classified into DC side of the alternating current (AC)/DC converter, DC/DC converter connected to photovoltaic (PV) system, DC line, and DC bus. The characteristics of fault current at each fault section are analyzed. Based on these analyses, the new protection scheme including the fault section estimation is proposed using WT. The proposed scheme estimates the fault section using the detail component after performing WT and sends the trip signal to each circuit breaker according to the fault section. The proposed protection scheme is verified through various simulations according to the fault region and fault current using electromagnetic transient program (EMTP)/ATPDraw and MATLAB. The simulation results show that the fault section is accurately determined, and the corresponding circuit breaker (CB) operations are performed.
Open AccessDevelopment of New Protection Scheme in DC Microgrid Using Wavelet Transform
The demand for a low voltage direct current (LVDC) microgrid is increasing by the increase of DC-based digital loads and renewable resources and the rapid development of power electronics technology. For the stable operation of an LVDC microgrid, it is necessary to develop a protection method. In this paper, the new protection scheme considering the fault section is proposed using wavelet transform (WT) in an LVDC microgrid. The fault sections are classified into DC side of the alternating current (AC)/DC converter, DC/DC converter connected to photovoltaic (PV) system, DC line, and DC bus. The characteristics of fault current at each fault section are analyzed. Based on these analyses, the new protection scheme including the fault section estimation is proposed using WT. The proposed scheme estimates the fault section using the detail component after performing WT and sends the trip signal to each circuit breaker according to the fault section. The proposed protection scheme is verified through various simulations according to the fault region and fault current using electromagnetic transient program (EMTP)/ATPDraw and MATLAB. The simulation results show that the fault section is accurately determined, and the corresponding circuit breaker (CB) operations are performed.
- Open Access
Fault Section Estimation in Radial LVDC Distribution System Using Wavelet Transform
The demand for low voltage DC (LVDC) distribution systems is increasing due to the rapid development of power conversion technology, the increase of DC-based digital loads, and the expansion of DC-based distributed generation (DG). For the stable operation of the LVDC distribution system, it is necessary to develop a protection method. In this paper, the fault section is estimated using wavelet transform (WT) in LVDC distribution system. The fault section is classified into a DC line and a DC bus. The characteristics of fault current at each fault section part are analyzed in simple and actual LVDC system. Based on this analysis, the algorithm for fault section estimation is proposed using the detail component after performing WT. The results of fault section estimations are verified through various simulations using EMTP and MATLAB. The fault section estimation can be utilized in the development of protection schemes in LVDC distribution system.
Open AccessFault Section Estimation in Radial LVDC Distribution System Using Wavelet Transform
The demand for low voltage DC (LVDC) distribution systems is increasing due to the rapid development of power conversion technology, the increase of DC-based digital loads, and the expansion of DC-based distributed generation (DG). For the stable operation of the LVDC distribution system, it is necessary to develop a protection method. In this paper, the fault section is estimated using wavelet transform (WT) in LVDC distribution system. The fault section is classified into a DC line and a DC bus. The characteristics of fault current at each fault section part are analyzed in simple and actual LVDC system. Based on this analysis, the algorithm for fault section estimation is proposed using the detail component after performing WT. The results of fault section estimations are verified through various simulations using EMTP and MATLAB. The fault section estimation can be utilized in the development of protection schemes in LVDC distribution system.
- Open Access
New Protection Scheme in Loop Distribution System with Distributed Generation
Loop distribution systems are increasingly used for reasons such as increased distributed generation (DG) and increased demand for a reliable and high-quality power supply. Because the loop distribution system involves bidirectional power flow, the method for protection of the radial distribution system cannot be applied. Therefore, a protection method is proposed herein for loop distribution systems. In this study, the existence of DG is also considered. According to the proposed method, the fault point is estimated on the basis of the equivalent circuit of the distribution system. Then, the fault section is determined and separated from the distribution system. The separation of DG is determined depending on whether the frequency and voltage are maintained within the steady state ranges. The proposed method is modelled and verified using the Electromagnetic Transients Program. Simulations according to the fault location are performed and analyzed. The results show that the method accurately determines the fault section so that normal power can be supplied to the healthy sections in the distribution system.
Open AccessNew Protection Scheme in Loop Distribution System with Distributed Generation
Loop distribution systems are increasingly used for reasons such as increased distributed generation (DG) and increased demand for a reliable and high-quality power supply. Because the loop distribution system involves bidirectional power flow, the method for protection of the radial distribution system cannot be applied. Therefore, a protection method is proposed herein for loop distribution systems. In this study, the existence of DG is also considered. According to the proposed method, the fault point is estimated on the basis of the equivalent circuit of the distribution system. Then, the fault section is determined and separated from the distribution system. The separation of DG is determined depending on whether the frequency and voltage are maintained within the steady state ranges. The proposed method is modelled and verified using the Electromagnetic Transients Program. Simulations according to the fault location are performed and analyzed. The results show that the method accurately determines the fault section so that normal power can be supplied to the healthy sections in the distribution system.
- Open Access
New Protection Scheme Based on Coordination with Tie Switch in an Open-Loop Microgrid
Owing to the increase in renewable energy, microgrids (MGs) are increasing. A MG has a small loop-type grid configuration. In the loop MG, challenges in protection such as maloperation of protection relay may occur owing to bidirectional current flow. Herein, we propose a new protection scheme in the loop MG. Considerations for protection in loop MG and fault characteristics are analyzed. Based on these, a new index to solve the considerations for MG protection are proposed using a wavelet transform. Furthermore, the new protection scheme based on the coordination with tie switch using the proposed new index is proposed. To verify the proposed scheme, the MG and the proposed scheme are modeled using the electromagnetic transients program and MATLAB. Various simulations according to the fault location and the success/failure of fault section separation are performed. Simulation results indicate that the power supply on the original feeder can be maintained by proposed method.
Open AccessNew Protection Scheme Based on Coordination with Tie Switch in an Open-Loop Microgrid
Owing to the increase in renewable energy, microgrids (MGs) are increasing. A MG has a small loop-type grid configuration. In the loop MG, challenges in protection such as maloperation of protection relay may occur owing to bidirectional current flow. Herein, we propose a new protection scheme in the loop MG. Considerations for protection in loop MG and fault characteristics are analyzed. Based on these, a new index to solve the considerations for MG protection are proposed using a wavelet transform. Furthermore, the new protection scheme based on the coordination with tie switch using the proposed new index is proposed. To verify the proposed scheme, the MG and the proposed scheme are modeled using the electromagnetic transients program and MATLAB. Various simulations according to the fault location and the success/failure of fault section separation are performed. Simulation results indicate that the power supply on the original feeder can be maintained by proposed method.
- Open Access
- 12 June 2019
- Published by MDPI AG in Applied Sciences
- Vol. 9 (12) , 2398
Systematization of the Simulation Process of Transformer Inrush Current Using EMTP
An inrush current is generated when a transformer is energized. This current has a large magnitude and rich harmonics, thereby causing mal-operation of the protection relay. Therefore, the development of countermeasures against inrush current is necessary, and this study has been performed by computer simulations. However, it is difficult for a power system operator to perform a computer simulation as it is difficult to determine what data should be selected and entered. Therefore, this paper establishes the simulation process of transformer inrush current using the Electromagnetic Transients Program (EMTP). Two methods to simulate the transformer inrush current are described in detail. Based on the actual 154 kV transformer test report in Korea, the simulation results of the inrush current using the two methods are discussed.
- 12 June 2019
- Published by MDPI AG in Applied Sciences
- Vol. 9 (12) , 2398
Open AccessSystematization of the Simulation Process of Transformer Inrush Current Using EMTP
An inrush current is generated when a transformer is energized. This current has a large magnitude and rich harmonics, thereby causing mal-operation of the protection relay. Therefore, the development of countermeasures against inrush current is necessary, and this study has been performed by computer simulations. However, it is difficult for a power system operator to perform a computer simulation as it is difficult to determine what data should be selected and entered. Therefore, this paper establishes the simulation process of transformer inrush current using the Electromagnetic Transients Program (EMTP). Two methods to simulate the transformer inrush current are described in detail. Based on the actual 154 kV transformer test report in Korea, the simulation results of the inrush current using the two methods are discussed.
- Open Access
Novel Protection Scheme considering Tie Switch Operation in an Open-Loop Distribution System using Wavelet Transform
Loop power distribution systems are gaining increasing attention due to improvements in the reliability of the power supply and the connection of distributed generation. With loop distribution systems, there is the possibility of mal-operation of the protection relay because of the existence of the tie switch and bi-directional current injection. In this paper, we propose a novel protection scheme considering the tie switch operation in the open loop power distribution system using wavelet transform. We analyze the possibility of mal-operation of the protection relay as a result of the normal load current after tie switch operation and analyze the characteristics of the normal load current and fault current injection after tie switch operation. Using these results, a new index is proposed to distinguish the normal load current and fault current, and a novel protection scheme based on this new index is proposed. The proposed method is modeled using an electromagnetic transients program and MATLAB, and the various simulations are performed according to the tie switch position, the fault location, and the success or failure of the fault section separation. From the simulation results, we can confirm that the normal load current and the fault current after tie switch operation can be accurately distinguished and the protection relay can accurately operate at only fault conditions.
Open AccessNovel Protection Scheme considering Tie Switch Operation in an Open-Loop Distribution System using Wavelet Transform
Loop power distribution systems are gaining increasing attention due to improvements in the reliability of the power supply and the connection of distributed generation. With loop distribution systems, there is the possibility of mal-operation of the protection relay because of the existence of the tie switch and bi-directional current injection. In this paper, we propose a novel protection scheme considering the tie switch operation in the open loop power distribution system using wavelet transform. We analyze the possibility of mal-operation of the protection relay as a result of the normal load current after tie switch operation and analyze the characteristics of the normal load current and fault current injection after tie switch operation. Using these results, a new index is proposed to distinguish the normal load current and fault current, and a novel protection scheme based on this new index is proposed. The proposed method is modeled using an electromagnetic transients program and MATLAB, and the various simulations are performed according to the tie switch position, the fault location, and the success or failure of the fault section separation. From the simulation results, we can confirm that the normal load current and the fault current after tie switch operation can be accurately distinguished and the protection relay can accurately operate at only fault conditions.
- Open Access
Development of Reclosing Method in a Distribution System with Distributed Generation and Battery Energy Storage System
The connection of distributed generation (DG) and a battery energy storage system (BESS) in distribution systems has recently been increasing. However, little research has been conducted on the reclosing of the distribution system when both the DG and BESS are connected. Therefore, this paper proposes a new reclosing method for a distribution system with a DG and BESS. The proposed method also has a circuit breaker (CB) installed in the distribution line. A CB close to the DG and BESS is first reclosed after a fixed dead time and, then, the fault clearance is detected using the current flowing to the fault point. Once the fault is cleared, the reclosing of the CB at the source side is attempted after completing a synchronism check. The proposed method is modeled using an electromagnetic transient program. We perform various simulations according to the capacities of the DG and the fault clearance time, and analyze the simulation results. The simulation results show that steady-state power is supplied to the load from the DG and BESS before reclosing to prevent outage, and that the reclosing is successfully performed.
Open AccessDevelopment of Reclosing Method in a Distribution System with Distributed Generation and Battery Energy Storage System
The connection of distributed generation (DG) and a battery energy storage system (BESS) in distribution systems has recently been increasing. However, little research has been conducted on the reclosing of the distribution system when both the DG and BESS are connected. Therefore, this paper proposes a new reclosing method for a distribution system with a DG and BESS. The proposed method also has a circuit breaker (CB) installed in the distribution line. A CB close to the DG and BESS is first reclosed after a fixed dead time and, then, the fault clearance is detected using the current flowing to the fault point. Once the fault is cleared, the reclosing of the CB at the source side is attempted after completing a synchronism check. The proposed method is modeled using an electromagnetic transient program. We perform various simulations according to the capacities of the DG and the fault clearance time, and analyze the simulation results. The simulation results show that steady-state power is supplied to the load from the DG and BESS before reclosing to prevent outage, and that the reclosing is successfully performed.