William S. P. Robertson
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
William S. P. Robertson has a total of 57 co-authors. Here are the top co-authors by number of shared publications:
- Claire Frances Jones
School of Electrical and Mechanical Engineering, The University of Adelaide, Adelaide, South Australia, Australia
6 shared publications - Dominic Thewlis
University of Adelaide
6 shared publications - Benjamin Seth Cazzolato
The University of Adelaide
5 shared publications - Johannes J. H. Paulides
Advanced Electromagnetics Group, Waalwijk, The Netherlands
4 shared publications - Matthew Forbes
The University of Adelaide
4 shared publications - Paul N. Grimshaw
School of Mechanical Engineering, University of Adelaide, Adelaide, SA, Australia
4 shared publications
Latest Publications
- 10 August 2026
- Published by Elsevier in Acta Astronautica
- Vol. 249, 32-42
Towards fully neuromorphic star tracking for spacecraft jitter mitigation
- 10 August 2026
- Published by Elsevier in Acta Astronautica
- Vol. 249, 32-42
Towards fully neuromorphic star tracking for spacecraft jitter mitigation
- Open Access
- 27 August 2025
- Published by Elsevier in The Spine Journal
- Vol. 26 (3) , 633-641
Passive neck stiffness and range of motion for males and females from early to late adulthood
- 27 August 2025
- Published by Elsevier in The Spine Journal
- Vol. 26 (3) , 633-641
Open AccessPassive neck stiffness and range of motion for males and females from early to late adulthood
- Open Access
- 5 March 2025
- Published by Elsevier in Applied Mathematical Modelling
- Vol. 144
A generalised Maxwell Stress Tensor for semi-analytic force and torque between permanent magnets, coils, and soft iron
- 5 March 2025
- Published by Elsevier in Applied Mathematical Modelling
- Vol. 144
Open AccessA generalised Maxwell Stress Tensor for semi-analytic force and torque between permanent magnets, coils, and soft iron
- Open Access
- 11 December 2024
- Published by The Royal Society in Journal of The Royal Society Interface
- Vol. 21 (221) , 20240565
Modelling individual variation in human walking gait across populations and walking conditions via gait recognition
Human walking gait is a personal story written by the body, a tool for understanding biological identity in healthcare and security. Gait analysis methods traditionally diverged between these domains but are now merging their complementary strengths to unlock new possibilities. Using large ground reaction force (GRF) datasets for gait recognition is a way to uncover subtle variations that define individual gait patterns. Previously, this was done by developing and evaluating machine learning models on the same individuals or the same dataset, potentially biasing findings towards population samples or walking conditions. This study introduces a new method for analysing gait variation across individuals, groups and datasets to explore how demographics and walking conditions shape individual gait patterns. Machine learning models were implemented using numerous configurations of four large walking GRF datasets from different countries (740 individuals, 7400 samples) and analysed using explainable artificial intelligence tools. Recognition accuracy ranged from 52 to 100%, with factors like footwear, walking speed and body mass playing interactive roles in defining gait. Models developed with individuals walking in personal footwear at multiple speeds effectively recognized novel individuals across populations and conditions (89–99% accuracy). Integrating force platform hardware and gait recognition software could be invaluable for reading the complex stories of human walking.
- 11 December 2024
- Published by The Royal Society in Journal of The Royal Society Interface
- Vol. 21 (221) , 20240565
Open AccessModelling individual variation in human walking gait across populations and walking conditions via gait recognition
Human walking gait is a personal story written by the body, a tool for understanding biological identity in healthcare and security. Gait analysis methods traditionally diverged between these domains but are now merging their complementary strengths to unlock new possibilities. Using large ground reaction force (GRF) datasets for gait recognition is a way to uncover subtle variations that define individual gait patterns. Previously, this was done by developing and evaluating machine learning models on the same individuals or the same dataset, potentially biasing findings towards population samples or walking conditions. This study introduces a new method for analysing gait variation across individuals, groups and datasets to explore how demographics and walking conditions shape individual gait patterns. Machine learning models were implemented using numerous configurations of four large walking GRF datasets from different countries (740 individuals, 7400 samples) and analysed using explainable artificial intelligence tools. Recognition accuracy ranged from 52 to 100%, with factors like footwear, walking speed and body mass playing interactive roles in defining gait. Models developed with individuals walking in personal footwear at multiple speeds effectively recognized novel individuals across populations and conditions (89–99% accuracy). Integrating force platform hardware and gait recognition software could be invaluable for reading the complex stories of human walking.
- Open Access
- 3 July 2024
- Published by Springer Nature in Sports Engineering
- Vol. 27 (2) , 1-12
A mechanical study of the influence of ankle joint angle on translational traction of soccer boots
The shoe–surface interaction for soccer players has both safety and performance implications. This interaction has been widely researched in terms of outsole configuration and surface type. However, these investigations, particularly those involving translational traction, often neglect the approach angle of the foot in terms of a real-world setting. This investigation considers the foot position prior to injuries such as anterior cruciate ligament tears, and observes how the translational traction alters with various angles for simulated plantarflexion, dorsiflexion, calcaneal inversion and calcaneal eversion. It was hypothesised that, as these angles increased, the translational traction would decrease as there would be less contact area between the boot and the surface compared to the neutral, flat footform. A custom-built testing apparatus recorded the translational traction of a soccer boot moving in four different directions at different loading angles on both a natural grass and artificial grass playing surface. A one-way ANOVA was performed, with a post-hoc Tukey Test to determine the significant differences between the translational traction between each angle. It was found that the geometry of the outsole configuration, more specifically, the apparent contact area between the shoe and surface played a significant role in the level of traction obtained. These results highlight the importance of stud geometry, particularly with respect to movements when the foot is angled as it would be in a potential injury scenario. Manufacturers should consider the profile of studs relative to the expected movements to not induce excessive traction, which could lead to potential foot fixation and injury.
- 3 July 2024
- Published by Springer Nature in Sports Engineering
- Vol. 27 (2) , 1-12
Open AccessA mechanical study of the influence of ankle joint angle on translational traction of soccer boots
The shoe–surface interaction for soccer players has both safety and performance implications. This interaction has been widely researched in terms of outsole configuration and surface type. However, these investigations, particularly those involving translational traction, often neglect the approach angle of the foot in terms of a real-world setting. This investigation considers the foot position prior to injuries such as anterior cruciate ligament tears, and observes how the translational traction alters with various angles for simulated plantarflexion, dorsiflexion, calcaneal inversion and calcaneal eversion. It was hypothesised that, as these angles increased, the translational traction would decrease as there would be less contact area between the boot and the surface compared to the neutral, flat footform. A custom-built testing apparatus recorded the translational traction of a soccer boot moving in four different directions at different loading angles on both a natural grass and artificial grass playing surface. A one-way ANOVA was performed, with a post-hoc Tukey Test to determine the significant differences between the translational traction between each angle. It was found that the geometry of the outsole configuration, more specifically, the apparent contact area between the shoe and surface played a significant role in the level of traction obtained. These results highlight the importance of stud geometry, particularly with respect to movements when the foot is angled as it would be in a potential injury scenario. Manufacturers should consider the profile of studs relative to the expected movements to not induce excessive traction, which could lead to potential foot fixation and injury.
- Open Access
- 13 June 2024
- Published by Springer Nature in Journal of Nonlinear Science
- Vol. 34 (4) , 1-29
Optimal Reconstruction of Vector Fields from Data for Prediction and Uncertainty Quantification
Predicting the evolution of dynamics from a given trajectory history of an unknown system is an important and challenging problem. This paper presents a model-free method of forecasting unknown chaotic systems through reconstructing vector fields from noisy measured data via an adaptation of optimal control methods. This technique is also applicable to partially observed systems using a Takens delay embedding approach. The algorithms are validated on the Lorenz system and the four-dimensional hyperchaotic Rössler system, and demonstrate successful predictions well beyond the Lyapunov timescale. It is found that for small datasets or datasets with large levels of noise, the prediction accuracy of partially observed systems approaches that of fully observed systems. The presented approach also allows the model-free assessment of local predictability on the attractor by evolving initial condition density through the reconstructed vector fields via estimation of the transfer operator. The method is compared to predictions made by an imperfect model which highlights the utility of model-free approaches when the only available models have significant model error. The capability of this method for reconstruction of continuous and global vector fields may be applied to model validation, forecasting of initial conditions not in the training set, and model-free filtering.
- 13 June 2024
- Published by Springer Nature in Journal of Nonlinear Science
- Vol. 34 (4) , 1-29
Open AccessOptimal Reconstruction of Vector Fields from Data for Prediction and Uncertainty Quantification
Predicting the evolution of dynamics from a given trajectory history of an unknown system is an important and challenging problem. This paper presents a model-free method of forecasting unknown chaotic systems through reconstructing vector fields from noisy measured data via an adaptation of optimal control methods. This technique is also applicable to partially observed systems using a Takens delay embedding approach. The algorithms are validated on the Lorenz system and the four-dimensional hyperchaotic Rössler system, and demonstrate successful predictions well beyond the Lyapunov timescale. It is found that for small datasets or datasets with large levels of noise, the prediction accuracy of partially observed systems approaches that of fully observed systems. The presented approach also allows the model-free assessment of local predictability on the attractor by evolving initial condition density through the reconstructed vector fields via estimation of the transfer operator. The method is compared to predictions made by an imperfect model which highlights the utility of model-free approaches when the only available models have significant model error. The capability of this method for reconstruction of continuous and global vector fields may be applied to model validation, forecasting of initial conditions not in the training set, and model-free filtering.
- Open Access
- 22 May 2024
- Published by Wiley in Advanced Physics Research
- Vol. 3 (7)
The Magnetic Field from Cylindrical Arc Coils and Magnets: A Compendium with New Analytic Solutions for Radial Magnetization and Azimuthal Current
This study provides analytic solutions for the magnetic field of coils and magnets that have a non‐axisymmetric cylindrical geometry with a rectangular cross‐section. New analytic solutions are provided for radially magnetized permanent magnet arcs, thin coil disc sectors, and thick coil sectors. If components of the 3D field are not representable in closed‐form or as canonical Legendre elliptic integrals, the exact solution is given in terms of a series of regularized beta functions. The limit and hence spatial convergence is found to these series, giving a well‐defined and fast solving algorithm for computation. The equations can be readily applied to find the magnetostatic field in linear or non‐linear systems that contain a large set of elements. Example applications are provided to demonstrate how the field can be used to calculate forces and benchmark computational efficiency of the equations. A thorough review of the preceding literature and background theory is provided before a detailed methodology obtaining the analytic solutions contained in this compendium, and further related geometries in cylindrical or spherical coordinates. This is the first study to comprehensively solve the field equations for this collection of electromagnetic geometries.
- 22 May 2024
- Published by Wiley in Advanced Physics Research
- Vol. 3 (7)
Open AccessThe Magnetic Field from Cylindrical Arc Coils and Magnets: A Compendium with New Analytic Solutions for Radial Magnetization and Azimuthal Current
This study provides analytic solutions for the magnetic field of coils and magnets that have a non‐axisymmetric cylindrical geometry with a rectangular cross‐section. New analytic solutions are provided for radially magnetized permanent magnet arcs, thin coil disc sectors, and thick coil sectors. If components of the 3D field are not representable in closed‐form or as canonical Legendre elliptic integrals, the exact solution is given in terms of a series of regularized beta functions. The limit and hence spatial convergence is found to these series, giving a well‐defined and fast solving algorithm for computation. The equations can be readily applied to find the magnetostatic field in linear or non‐linear systems that contain a large set of elements. Example applications are provided to demonstrate how the field can be used to calculate forces and benchmark computational efficiency of the equations. A thorough review of the preceding literature and background theory is provided before a detailed methodology obtaining the analytic solutions contained in this compendium, and further related geometries in cylindrical or spherical coordinates. This is the first study to comprehensively solve the field equations for this collection of electromagnetic geometries.
- Open Access
- 24 April 2024
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 52 (8) , 2178-2192
Evaluation of Apparatus and Protocols to Measure Human Passive Neck Stiffness and Range of Motion
Understanding of human neck stiffness and range of motion (ROM) with minimal neck muscle activation (“passive”) is important for clinical and bioengineering applications. The aim of this study was to develop, implement, and evaluate the reliability of methods for assessing passive-lying stiffness and ROM, in six head-neck rotation directions. Six participants completed two assessment sessions. To perform passive-lying tests, the participant’s head and torso were strapped to a bending (flexion, extension, lateral bending) or a rotation (axial rotation) apparatus, and clinical bed, respectively. The head and neck were manually rotated by the researcher to the participant’s maximum ROM, to assess passive-lying stiffness. Participant-initiated (“active”) head ROM was also assessed in the apparatus, and seated. Various measures of apparatus functionality were assessed. ROM was similar for all assessment configurations in each motion direction except flexion. In each direction, passive stiffness generally increased throughout neck rotation. Within-session reliability for stiffness (ICC > 0.656) and ROM (ICC > 0.872) was acceptable, but between-session reliability was low for some motion directions, probably due to intrinsic participant factors, participant-apparatus interaction, and the relatively low participant number. Moment-angle corridors from both assessment sessions were similar, suggesting that with greater sample size, these methods may be suitable for estimating population-level corridors.
- 24 April 2024
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 52 (8) , 2178-2192
Open AccessEvaluation of Apparatus and Protocols to Measure Human Passive Neck Stiffness and Range of Motion
Understanding of human neck stiffness and range of motion (ROM) with minimal neck muscle activation (“passive”) is important for clinical and bioengineering applications. The aim of this study was to develop, implement, and evaluate the reliability of methods for assessing passive-lying stiffness and ROM, in six head-neck rotation directions. Six participants completed two assessment sessions. To perform passive-lying tests, the participant’s head and torso were strapped to a bending (flexion, extension, lateral bending) or a rotation (axial rotation) apparatus, and clinical bed, respectively. The head and neck were manually rotated by the researcher to the participant’s maximum ROM, to assess passive-lying stiffness. Participant-initiated (“active”) head ROM was also assessed in the apparatus, and seated. Various measures of apparatus functionality were assessed. ROM was similar for all assessment configurations in each motion direction except flexion. In each direction, passive stiffness generally increased throughout neck rotation. Within-session reliability for stiffness (ICC > 0.656) and ROM (ICC > 0.872) was acceptable, but between-session reliability was low for some motion directions, probably due to intrinsic participant factors, participant-apparatus interaction, and the relatively low participant number. Moment-angle corridors from both assessment sessions were similar, suggesting that with greater sample size, these methods may be suitable for estimating population-level corridors.
- Open Access
- 9 April 2024
- Published by Elsevier in Journal of Biomechanics
- Vol. 168, 112090
Neck stiffness and range of motion for young males and females
- 9 April 2024
- Published by Elsevier in Journal of Biomechanics
- Vol. 168, 112090
Open AccessNeck stiffness and range of motion for young males and females