ADAlex G. Dukas

Alex G. Dukas

*This is an algorithmically generated author record based on publicly available information.

Alex G. Dukas has a total of 72 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Arthroscopic Reduction and Fixation of a Lesser Trochanter Avulsion Nonunion

    by Alex G. Dukas, Taylor L. King, Temitope F. Adeyemi, Travis G. Maak

    Identifying and treating avulsion fractures of the pelvis and proximal femur in adolescent athletes has become increasingly more important as the rate of competitive sports participation has grown. The majority of these fractures can be treated conservatively, with most returning to full activity. Surgical treatment of these injuries has been traditionally indicated for >2 cm displacement, painful nonunion, symptomatic exostosis formation, or persistent pain and symptoms. Lesser trochanter avulsion injuries are extremely rare and literature outlining their surgical treatment lacking. We present our method of arthroscopic reduction and fixation of lesser trochanter avulsion nonunions. Technique Video: video See video under supplementary data.


  • Surgical Treatment for FAI: Arthroscopic and Open Techniques for Osteoplasty

    by Alex G. Dukas, Andrew S. Gupta, Christopher L. Peters, Stephen K. Aoki

    To review the relevant literature and techniques regarding arthroscopic and open treatment of femoroacetabular impingement (FAI). To discuss both the senior authors’ preferred method of arthroscopic and open treatment of FAI.


  • Open Access

    Biomechanical Comparison of Olecranon Sled Versus Intramedullary Screw Tension Banding for Olecranon Osteotomies

    by Cameron Kia, Alex G. Dukas, Silas T. Marshall, Andreas Voss, Elifho Obopilwe, Bruce D. Browner, Augustus D. Mazzocca

    Olecranon osteotomies are frequently performed to gain access to the distal humeral articular surface. Repair of the osteotomy or fixation of a simple 2-part olecranon fracture with traditional tension band construct is often plagued by complication. Proximal migration and irritation attributed to hardware are common complications of the standard construct of an intramedullary screw with tension band and are causes for reoperation. To compare the biomechanical performance, time of implant, and prominence of an intramedullary screw and tension band construct with that of a newer low-profile continuous loop tension band (Olecranon Sled) construct in an olecranon osteotomy model. Controlled laboratory study. Chevron osteotomies were created in 6 matched pairs of fresh-frozen human elbows (mean age, 66 ± 16 years). Each matched pair was then randomly divided into 1 of 2 groups: fixation with a screw and tension band construct or the Olecranon Sled. Bone mineral density, implant prominence, and time for implantation were recorded. Following olecranon fixation, each specimen underwent cyclic loading of 0 to 10 N for 100 cycles (to simulate unresisted active range of motion) and then 0 to 500 N for 500 cycles (to simulate pushing up from a chair) to measure for any displacement at the osteotomy site. The constructs were then loaded to failure and compared. No differences were found in bone mineral density between the 2 groups (P = .290). When measured from the tip of the olecranon, the continuous loop tension band had a medial prominence of only 3.57 ± 0.4 mm, as opposed to the intramedullary screw fixation of 7.288 ± 0.762 mm (P = .027). Total time of implantation, including osteotomy preparation, was a mean 155 seconds shorter with the Olecranon Sled versus the traditional tension band (P < .05). Because of the fracture of 1 specimen during cyclic loading, it and its matched counterpart were excluded, and only 5 matched pairs were analyzed for displacement and load to failure. There were no significant differences between groups in load to failure or displacement during cyclic loading (P > .05). The Olecranon Sled device was found to have no difference in biomechanical strength from that of the standard intramedullary screw with tension band construct. The Olecranon Sled was also found to be significantly less prominent while being faster to implant than the intramedullary screw. Evaluating an alternative option to the standard tension band construct is important for patients with olecranon fractures or osteotomies, as standard techniques have been fraught with hardware issues and need for revision surgery.


  • Open Access

    Biomechanical Comparison of Epiphyseal Anterior Cruciate Ligament Fixation Using a Cortical Button Construct Versus an Interference Screw and Sheath Construct in Skeletally Immature Cadaveric Specimens

    by Alex G. Dukas, Kevin G. Shea, Carl W. Nissen, Elifho Obopilwe, Peter D. Fabricant, Peter C. Cannamela, Matthew D. Milewski

    Anterior cruciate ligament (ACL) ruptures have become increasingly common in pediatric and adolescent athletes. While multiple methods exist, all-epiphyseal ACL reconstruction is a popular technique in the skeletally immature patient. Given the high rate of reruptures in this population and the increasing number of commercially available fixation devices, biomechanical testing is crucial to understand the performance of these devices in pediatric epiphyseal bone. To our knowledge, there has not been a biomechanical analysis of ACL fixation devices in skeletally immature bone. To compare cortically based button fixation with interference screw and sheath fixation in skeletally immature femoral epiphyseal cadaveric bone. Our hypothesis was that there would be no difference in peak load to failure, stiffness, or cyclic displacement between these 2 fixation constructs. Controlled laboratory study. Fresh-frozen matched-pair knees from 3 pediatric cadaveric specimens were obtained. A synthetic graft was fixed in an all-epiphyseal femoral tunnel. Both the lateral and medial condyles were utilized to increase the sample size. Specimens were randomized and assigned to receive either an interference screw and sheath construct designed for pediatric patients or an adjustable loop cortical button. Biomechanical testing was performed to obtain ultimate load to failure, stiffness, total displacement after 500 cycles, and the failure mode for each condyle. Each medial and lateral condyle in 3 pairs of skeletally immature cadaveric knees (ages 7, 9, and 11 years) was utilized for testing. One specimen was excluded after it failed by having a transphyseal fracture. The median peak load to failure was 769.80 N (interquartile range [IQR], 628.50-930.41 N) for the screw and sheath group and 862.80 N (IQR, 692.34-872.65 N) for the button group (P = .893). The median displacement after 500 cycles for the screw and sheath group was 0.65 mm (IQR, 0.47-1.03 mm) and 1.13 mm (IQR, 0.96-1.25 mm) for the button group (P = .08). The median stiffness of the screw and sheath group was significantly higher than that of the button group (31.47 N/mm [IQR, 26.40-43.00 N/mm] vs 25.22 N/mm [IQR, 21.18-27.07 N/mm], respectively) (P = .043). When comparing femoral fixation with a screw and sheath construct developed for pediatric patients to an adjustable loop cortical button in skeletally immature bone, our results showed that fixation did not significantly differ with respect to cyclic displacement or peak load to failure. While the screw and sheath construct was significantly stiffer, its effect on clinical outcomes is not yet known. With regard to femoral fixation, there is no significant biomechanical difference between the use of cortically based button fixation or interference screw and sheath fixation in pediatric epiphyseal cadaveric bone.


  • Arthrex TightRope Fixation of a Soft Tissue Graft

    by Alex G. Dukas, James Kristopher Ware, Thomas M. DeBerardino

  • Anterior Cruciate Ligament All-Inside Retroconstruction: Single- and Double-Bundle Techniques

    by James Kristopher Ware, Alex G. Dukas, Thomas M. DeBerardino

  • A Biomechanical Analysis of Different Clavicular Tunnel Diameters in Anatomic Acromioclavicular Ligament Reconstruction

    by Andreas Voss, Knut Beitzel, Farhang Alaee, Alex Dukas, Elmar Herbst, Elifho Obopilwe, John Apostolakos, Jessica DiVenere, Hardeep Singh, Mark P. Cote, et al.

    Purpose: To evaluate the biomechanical stability of a tendon–to–clavicle bone interface fixation of a graft in revision acromioclavicular reconstruction. Methods: Fifteen fresh‐frozen cadaveric shoulders were used. All specimens underwent bone density evaluation. For the primary reconstruction, a 5‐mm semitendinosus allograft was inserted into a 5‐mm bone tunnel at 25 and 45 mm from the lateral end of the clavicle using a 5.5 × 8–mm PEEK (polyether ether ketone) tenodesis screw. Each single graft was fixed in a cryo‐clamp and cyclically loaded from 5 to 70 N for 3,000 cycles, followed by load‐to‐failure testing at a rate of 120 mm/min to simulate the revision case. To simulate tunnel widening, the tunnels of the revision series were over‐drilled with an 8‐mm drill, and a 5‐mm semitendinosus graft with an 8 × 12–mm PEEK tenodesis screw was inserted. Biomechanical testing was then repeated. Results: The bone mineral density analysis showed a significantly higher density at the 45‐mm hole compared with the 25‐mm hole ( P = .001). The ultimate load to failure increased from the 5.5‐mm screw to the 8‐mm screw at the 45‐mm hole position ( P = .001). There was no statistically significant difference at the 25‐mm hole position ( P = .934). No statistical significance for graft elongation comparing the 5.5‐mm screw and the 8‐mm screw at the 25‐mm ( P = .156) and 45‐mm ( P = .334) positions could be found. Conclusions: Comparable biomechanical stability for the tendon‐to‐bone interface fixation in different clavicular tunnel diameters simulating primary and revision reconstruction was achieved. Clinical Relevance: There is a lack of literature regarding revision acromioclavicular joint reconstruction, but our biomechanical results show comparable stability to primary reconstruction. These data provide support for the use of anatomic acromioclavicular ligament reconstruction in revision cases.


  • Systemic Administration of Sclerostin Antibody Enhances Bone Morphogenetic Protein-Induced Femoral Defect Repair in a Rat Model

    by Brian A. Tinsley, Alex Dukas, Michael J. Pensak, Douglas J. Adams, Amy H. Tang, Michael S. Ominsky, Hua Zhu Ke, Jay R. Lieberman

    Background: Recombinant human bone morphogenetic protein (rhBMP)-2 is a potent osteoinductive agent; however, its clinical use has been reduced because of safety and efficacy concerns. In preclinical studies involving a critical-sized defect in a rat model, sclerostin antibody (Scl-Ab) treatment increased bone formation within the defect but did not result in reliable healing. The purpose of the current study was to evaluate bone repair of a critical-sized femoral defect in a rat model with use of local implantation of rhBMP-2 combined with systemic administration of Scl-Ab. Methods: A critical-sized femoral defect was created in rats randomized into three treatment groups: local rhBMP-2 and systemic Scl-Ab (Scl + BMP), local rhBMP-2 alone, and collagen sponge alone (operative control). The Scl + BMP group received local rhBMP-2 (10 μg) on a collagen sponge placed within the defect intraoperatively and then twice weekly injections of Scl-Ab (25 mg/kg) administered postoperatively. The femora were evaluated at twelve weeks with use of radiography, microcomputed tomography (microCT), histomorphometric analysis, and biomechanical testing. Results: At twelve weeks, all Scl + BMP and rhBMP-2 only samples were healed. No femora healed in the operative control group. Histomorphometric analysis demonstrated more bone in the Scl + BMP samples than in the samples treated with rhBMP-2 alone (p = 0.029) and the control samples (p = 0.003). MicroCT revealed that the Scl + BMP group had a 90% greater bone volume within the defect region compared with the rhBMP-2 group and a 350% greater bone volume compared with the operative control group (p < 0.001). Biomechanical testing showed that the group treated with Scl + BMP had greater torsional strength and rigidity compared with the rhBMP-2 group (p < 0.001 and p = 0.047) and the intact femoral control group (p < 0.001). Torque to failure was lower in the rhBMP-2 group compared with the intact femoral control group (p < 0.002). Mean energy to failure was higher in the Scl + BMP samples compared with the rhBMP-2 only samples (p = 0.001). Conclusions: In a critical-sized femoral defect in a rat model, local rhBMP-2 combined with systemic administration of Scl-Ab resulted in more robust healing that was stronger and more rigid than results for rhBMP-2 alone and intact nonoperative femora. Clinical Relevance: Our study demonstrated that combining an osteoinductive agent with a systemically administered antibody that promotes bone formation can enhance bone repair and has potential as a therapeutic regimen in humans.


  • Combination therapy with PTH and DBM cannot heal a critical sized murine femoral defect

    by Michael Pensak, Seung-Hyun Hong, Alex Dukas, Jennifer Bayron, Brian Tinsley, Ashish Jain, Amy Tang, David Rowe, Jay R. Lieberman

    Orthopaedic surgeons continue to search for cost-effective bone graft substitutes to enhance bone repair. Teriparatide (PTH 1-34) and demineralized bone matrix (DBM) have been used in patients to promote bone healing. We evaluated the efficacy of PTH and DBM in healing a critical sized femoral defect in three lineage-specific transgenic mice expressing Col3.6GFPtopaz (pre-osteoblastic marker), Col2.3GFPemerald (osteoblastic marker) and α-SMA-Cherry (pericyte/myofibroblast marker). Mid-diaphyseal defects measuring 2 mm in length were created in the central 1/3 of mice femora using a circular saw and stabilized with an alveolar distractor device and cerclage wires. Three groups were evaluated: Group I, PTH 30 μg/kg injection daily, Group II, PTH 30 μg/kg injection daily + DBM, and Group III, DBM + 30μL saline injection. PTH was given for 28 days or until the time of sacrifice. Animals were sacrificed at 7, 14, 28, and 56 days. Radiographs at the time of sacrifice were evaluated using a 5-point scaled scoring system. Radiographs showed a lack of healing across all treatment groups at all time points: Group I, 1.57 +/- 0.68; Group II, 3.00 +/- 1.29; and Group III, 2.90 +/- 1.03. Bone formation in the defect as measured by radiographic healing score was significantly better at 56 days in Groups II (p = 0.01) and III (p < 0.01) compared to Group I. Across all treatment groups and time points the defects were largely absent of osteoprogenitor cells based on gross observation of frozen histology and quantitation of cellular based histomorphometric parameters. Quantitation of frozen histologic slides showed a limited osteoprogenitor response to PTH and DBM. Our results suggest that the anabolic agent teriparatide is unable to induce healing in a critical sized mouse femoral defect when given alone or in combination with the DBM preparation we used as a local bone graft substitute. © 2015 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 33:1242-1249, 2015.