Daniel Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Daniel Li has a total of 58 co-authors. Here are the top co-authors by number of shared publications:
- Alexander R. Horswill
Department of Immunology and Microbiology, University of Colorado School of Medicine
2 shared publications - Amelia Staats
Department of Microbiology, The Ohio State University, Columbus, Ohio, USA
2 shared publications - Anne Sullivan
Department of Orthopaedics, The Ohio State University Wexner Medical Center, Columbus, Ohio, USA
2 shared publications - Bennet A. Butler
Northwestern University Feinberg School of Medicine
2 shared publications - Paul Stoodley
Department of Microbial Infection and Immunity, The Ohio State University, Columbus, OH 43210, USA
2 shared publications - Peter W. Burback
Department of Microbial Infection and Immunity, The Ohio State University, Columbus, Ohio, USA
2 shared publications
Latest Publications
- 25 April 2023
- Published by American Society for Microbiology in Journal of Bacteriology
- Vol. 205 (4) , e0045122
In Vitro Staphylococcal Aggregate Morphology and Protection from Antibiotics Are Dependent on Distinct Mechanisms Arising from Postsurgical Joint Components and Fluid Motion
The formation of a bacterial biofilm in the postsurgical joint environment significantly complicates the resolution of an infection. To form a resilient biofilm, incoming bacteria must first survive the initial invasion of the joint space.
- 25 April 2023
- Published by American Society for Microbiology in Journal of Bacteriology
- Vol. 205 (4) , e0045122
In Vitro Staphylococcal Aggregate Morphology and Protection from Antibiotics Are Dependent on Distinct Mechanisms Arising from Postsurgical Joint Components and Fluid Motion
The formation of a bacterial biofilm in the postsurgical joint environment significantly complicates the resolution of an infection. To form a resilient biofilm, incoming bacteria must first survive the initial invasion of the joint space.
- Open Access
- 26 April 2022
- Published by American Society for Microbiology in mBio
- Vol. 13 (2) , e0023622
Rapid Aggregation of Staphylococcus aureus in Synovial Fluid Is Influenced by Synovial Fluid Concentration, Viscosity, and Fluid Dynamics, with Evidence of Polymer Bridging
Infection is a major complication of knee and hip joint replacement surgery, which is used to treat arthritis or joint damage. We have shown that Staphylococcus aureus , a common bacterial pathogen, aggregates upon contact with synovial fluid.
- 26 April 2022
- Published by American Society for Microbiology in mBio
- Vol. 13 (2) , e0023622
Open AccessRapid Aggregation of Staphylococcus aureus in Synovial Fluid Is Influenced by Synovial Fluid Concentration, Viscosity, and Fluid Dynamics, with Evidence of Polymer Bridging
Infection is a major complication of knee and hip joint replacement surgery, which is used to treat arthritis or joint damage. We have shown that Staphylococcus aureus , a common bacterial pathogen, aggregates upon contact with synovial fluid.
- 1 July 2019
- Published by Elsevier in Journal of Science and Medicine in Sport
- Vol. 22 (7) , 758-762
CrossFit and rhabdomyolysis: A case series of 11 patients presenting at a single academic institution
- 1 July 2019
- Published by Elsevier in Journal of Science and Medicine in Sport
- Vol. 22 (7) , 758-762
CrossFit and rhabdomyolysis: A case series of 11 patients presenting at a single academic institution
- 1 September 2018
- Published by Wolters Kluwer Health in Plastic and Reconstructive Surgery
- Vol. 142 (3) , 264e-270e
Nitroglycerin Ointment for Reducing the Rate of Mastectomy Flap Necrosis in Immediate Implant-Based Breast Reconstruction
Mastectomy flap necrosis (MFN) remains a challenging complication in immediate tissue expander breast reconstruction (ITEBR). Nitroglycerin ointment has been shown to reduce the incidence of MFN in a randomized controlled study, using 45g per breast and treating one side only in bilateral cases. This study was conducted to determine the efficacy of 15g of nitroglycerin ointment per breast - therefore permitting application to both breasts in cases of bilateral mastectomy. A retrospective cohort study of patients undergoing ITEBR by a single reconstructive surgeon was conducted. The intervention cohort consisted of all patients between June 10, 2015 and June 9, 2016 (94 patients, 158 breasts), where 15g of nitroglycerin ointment was routinely applied per breast. The control cohort consisted of all patients from June 10, 2014 to June 9, 2015 (107 patients, 170 breasts) where nitroglycerin was not applied. All complications were tracked including minor wound healing problems. There was an overall 22% decreased incidence of MFN in the nitroglycerin ointment cohort (47.5% vs. 60.6%, p=0.002), with a 44% reduction in full thickness MFN that trended towards statistical significance (9.5% vs. 16.5%, p=0.06). On multivariate analysis, nitroglycerin application was independently associated with a decrease in MFN or need for mastectomy flap debridement. There was no significant difference in the incidence of post-operative hypotension (3.8 vs. 2.9%) or headache among cohorts. Topical nitroglycerin ointment application to mastectomy skin flaps at 15g per breast is a cost-effective means to decrease the incidence of MFN in unilateral and bilateral ITEBR.
- 1 September 2018
- Published by Wolters Kluwer Health in Plastic and Reconstructive Surgery
- Vol. 142 (3) , 264e-270e
Nitroglycerin Ointment for Reducing the Rate of Mastectomy Flap Necrosis in Immediate Implant-Based Breast Reconstruction
Mastectomy flap necrosis (MFN) remains a challenging complication in immediate tissue expander breast reconstruction (ITEBR). Nitroglycerin ointment has been shown to reduce the incidence of MFN in a randomized controlled study, using 45g per breast and treating one side only in bilateral cases. This study was conducted to determine the efficacy of 15g of nitroglycerin ointment per breast - therefore permitting application to both breasts in cases of bilateral mastectomy. A retrospective cohort study of patients undergoing ITEBR by a single reconstructive surgeon was conducted. The intervention cohort consisted of all patients between June 10, 2015 and June 9, 2016 (94 patients, 158 breasts), where 15g of nitroglycerin ointment was routinely applied per breast. The control cohort consisted of all patients from June 10, 2014 to June 9, 2015 (107 patients, 170 breasts) where nitroglycerin was not applied. All complications were tracked including minor wound healing problems. There was an overall 22% decreased incidence of MFN in the nitroglycerin ointment cohort (47.5% vs. 60.6%, p=0.002), with a 44% reduction in full thickness MFN that trended towards statistical significance (9.5% vs. 16.5%, p=0.06). On multivariate analysis, nitroglycerin application was independently associated with a decrease in MFN or need for mastectomy flap debridement. There was no significant difference in the incidence of post-operative hypotension (3.8 vs. 2.9%) or headache among cohorts. Topical nitroglycerin ointment application to mastectomy skin flaps at 15g per breast is a cost-effective means to decrease the incidence of MFN in unilateral and bilateral ITEBR.
- 1 May 2018
- Published by Elsevier in Journal of Orthopaedic Science
- Vol. 23 (3) , 542-545
Early diagnosis of septic arthritis in immunocompromised patients
- 1 May 2018
- Published by Elsevier in Journal of Orthopaedic Science
- Vol. 23 (3) , 542-545
Early diagnosis of septic arthritis in immunocompromised patients
- Open Access
- 31 March 2017
- Published by Springer Nature in Journal of Orthopaedic Surgery and Research
- Vol. 12 (1) , 53
Novel intramedullary device for lengthening transfemoral residual limbs
Lower limb loss is a highly disabling medical condition that can severely impact a person’s quality of life. Recovery becomes especially challenging if an amputee has a short residual limb, which can complicate proper prosthetic fitting, causing discomfort, difficulties in suspension, and reduced mobility. Current limb lengthening techniques such as the Ilizarov apparatus and external fixators are cumbersome, uncomfortable, and have high complication rates. In this study, we investigated the effectiveness of a novel limb-lengthening device that uses intramedullary bone lengthening and requires only one percutaneous rod at the end of the limb during the distraction phase. Only the intramedullary nail remains after the distraction phase, and no external components are required during the consolidation phase. We hypothesize that this system would create a much easier experience for the patient. The system was first tested in a mock surgical implantation using plastic femur bones. The device was then tested in a series of cadaveric experiments using pelvis-to-knee specimens by a group of surgeons. Surgeons evaluated the surgical insertion technique, soft tissue considerations, hardware fixation strategies, and the effectiveness of the distraction mechanism. Revisions and improvements to the device and surgical procedure were made based on the results from the cadaveric experiments. A questionnaire was given to two visiting surgeons following the final iteration of the device. The surgeons reported that the system effectively lengthened the limb, was sturdy, and could be installed efficiently. However, there remains a risk of infection and soft tissue imbalances, similar to that introduced by an external fixator device. Suggestions on how to improve the design of the device and mitigate infection through postoperative management and surgical standard of care will be considered for future clinical trials. The described intramedullary residual limb-lengthening device has evolved from a prototype to a mature model tested in six cadaveric experiments to date. Further mechanical and functional testing is needed to finalize the device before testing in patients.
- 31 March 2017
- Published by Springer Nature in Journal of Orthopaedic Surgery and Research
- Vol. 12 (1) , 53
Open AccessNovel intramedullary device for lengthening transfemoral residual limbs
Lower limb loss is a highly disabling medical condition that can severely impact a person’s quality of life. Recovery becomes especially challenging if an amputee has a short residual limb, which can complicate proper prosthetic fitting, causing discomfort, difficulties in suspension, and reduced mobility. Current limb lengthening techniques such as the Ilizarov apparatus and external fixators are cumbersome, uncomfortable, and have high complication rates. In this study, we investigated the effectiveness of a novel limb-lengthening device that uses intramedullary bone lengthening and requires only one percutaneous rod at the end of the limb during the distraction phase. Only the intramedullary nail remains after the distraction phase, and no external components are required during the consolidation phase. We hypothesize that this system would create a much easier experience for the patient. The system was first tested in a mock surgical implantation using plastic femur bones. The device was then tested in a series of cadaveric experiments using pelvis-to-knee specimens by a group of surgeons. Surgeons evaluated the surgical insertion technique, soft tissue considerations, hardware fixation strategies, and the effectiveness of the distraction mechanism. Revisions and improvements to the device and surgical procedure were made based on the results from the cadaveric experiments. A questionnaire was given to two visiting surgeons following the final iteration of the device. The surgeons reported that the system effectively lengthened the limb, was sturdy, and could be installed efficiently. However, there remains a risk of infection and soft tissue imbalances, similar to that introduced by an external fixator device. Suggestions on how to improve the design of the device and mitigate infection through postoperative management and surgical standard of care will be considered for future clinical trials. The described intramedullary residual limb-lengthening device has evolved from a prototype to a mature model tested in six cadaveric experiments to date. Further mechanical and functional testing is needed to finalize the device before testing in patients.
- 20 February 2017
- Published by AIP Publishing in Applied Physics Letters
- Vol. 110 (8)
On the wetting behavior of ceria thin films grown by pulsed laser deposition
Polymers are most widely used in the production of water-repellant coatings. However, their use in applications requiring wear resistance or high-temperature stability is extremely limited. A recent report suggests that wear resistant, thermally stable rare earth oxide materials like cerium dioxide (ceria) are intrinsically water repellant. We have studied this intriguing finding for ceria thin films fabricated by pulsed laser deposition (PLD) at different oxygen pressures and different substrate temperatures. We used a custom apparatus for measuring water contact angles on ceria films deposited by PLD. X-ray photoelectron spectroscopy was used to determine the relationship between the ceria wetting behavior and ceria surface chemistry. Our results show that ceria thin films are intrinsically hydrophilic and that hydrophobicity arises due to adsorption of hydrocarbon species after ∼24 h.
- 20 February 2017
- Published by AIP Publishing in Applied Physics Letters
- Vol. 110 (8)
On the wetting behavior of ceria thin films grown by pulsed laser deposition
Polymers are most widely used in the production of water-repellant coatings. However, their use in applications requiring wear resistance or high-temperature stability is extremely limited. A recent report suggests that wear resistant, thermally stable rare earth oxide materials like cerium dioxide (ceria) are intrinsically water repellant. We have studied this intriguing finding for ceria thin films fabricated by pulsed laser deposition (PLD) at different oxygen pressures and different substrate temperatures. We used a custom apparatus for measuring water contact angles on ceria films deposited by PLD. X-ray photoelectron spectroscopy was used to determine the relationship between the ceria wetting behavior and ceria surface chemistry. Our results show that ceria thin films are intrinsically hydrophilic and that hydrophobicity arises due to adsorption of hydrocarbon species after ∼24 h.
- 22 July 2015
- Published by Royal Society of Chemistry (RSC) in Journal of Materials Chemistry B
- Vol. 3 (34) , 6885-6896
In vitro and in vivo drug release behavior and osteogenic potential of a composite scaffold based on poly(ε-caprolactone)-block-poly(lactic-co-glycolic acid) and β-tricalcium phosphate
To cure serious bone tuberculosis, a novel long-term drug delivery system was designed and prepared to satisfy the needs of both bone regeneration and antituberculous drug therapy.
- 22 July 2015
- Published by Royal Society of Chemistry (RSC) in Journal of Materials Chemistry B
- Vol. 3 (34) , 6885-6896
In vitro and in vivo drug release behavior and osteogenic potential of a composite scaffold based on poly(ε-caprolactone)-block-poly(lactic-co-glycolic acid) and β-tricalcium phosphate
To cure serious bone tuberculosis, a novel long-term drug delivery system was designed and prepared to satisfy the needs of both bone regeneration and antituberculous drug therapy.
- Open Access
- 24 July 2013
- Published by Springer Nature in Journal of Orthopaedic Surgery and Research
- Vol. 8 (1) , 24
Preliminary evaluation of a robotic apparatus for the analysis of passive glenohumeral joint kinematics
Background: The shoulder has the greatest range of motion of any joint in the human body. This is due, in part, to the complex interplay between the glenohumeral (GH) joint and the scapulothoracic (ST) articulation. Currently, our ability to study shoulder kinematics is limited, because existing models isolate the GH joint and rely on manual manipulation to create motion, and have low reproducibility. Similarly, most established techniques track shoulder motion discontinuously with limited accuracy.Methods: To overcome these problems, we have designed a novel system in which the shoulder girdle is studied intact, incorporating both GH and ST motions. In this system, highly reproducible trajectories are created using a robotic actuator to control the intact shoulder girdle. High-speed cameras are employed to track retroreflective bone markers continuously.Results: We evaluated this automated system’s capacity to reproducibly capture GH translation in intact and pathologic shoulder conditions. A pair of shoulders (left and right) were tested during forward elevation at baseline, with a winged scapula, and after creation of a full thickness supraspinatus tear.Discussion: The system detected differences in GH translations as small as 0.5 mm between different conditions. For each, three consecutive trials were performed and demonstrated high reproducibility and high precision.
- 24 July 2013
- Published by Springer Nature in Journal of Orthopaedic Surgery and Research
- Vol. 8 (1) , 24
Open AccessPreliminary evaluation of a robotic apparatus for the analysis of passive glenohumeral joint kinematics
Background: The shoulder has the greatest range of motion of any joint in the human body. This is due, in part, to the complex interplay between the glenohumeral (GH) joint and the scapulothoracic (ST) articulation. Currently, our ability to study shoulder kinematics is limited, because existing models isolate the GH joint and rely on manual manipulation to create motion, and have low reproducibility. Similarly, most established techniques track shoulder motion discontinuously with limited accuracy.Methods: To overcome these problems, we have designed a novel system in which the shoulder girdle is studied intact, incorporating both GH and ST motions. In this system, highly reproducible trajectories are created using a robotic actuator to control the intact shoulder girdle. High-speed cameras are employed to track retroreflective bone markers continuously.Results: We evaluated this automated system’s capacity to reproducibly capture GH translation in intact and pathologic shoulder conditions. A pair of shoulders (left and right) were tested during forward elevation at baseline, with a winged scapula, and after creation of a full thickness supraspinatus tear.Discussion: The system detected differences in GH translations as small as 0.5 mm between different conditions. For each, three consecutive trials were performed and demonstrated high reproducibility and high precision.