Brecht Laforce
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Brecht Laforce has a total of 67 co-authors. Here are the top co-authors by number of shared publications:
Laszlo Vincze
8 shared publicationsBart Vekemans
Department of Chemistry, Ghent University, Ghent, Belgium
6 shared publications- Laszlo Vincze
Department of Chemistry, Ghent University, Krijgslaan 281 S12, B-9000 Ghent, Belgium
4 shared publications - Matthieu Nicolaas Boone
Ghent University
4 shared publications Luc Van Hoorebeke
UGCT-Department of Physics and Astronomy, Ghent University, Proeftuinstraat 86, B-9000 Ghent, Belgium
3 shared publications- Veerle Cnudde
PProGRess-UGCT, Department of Geology, Ghent University, Ghent, Belgium
3 shared publications
Latest Publications
- 9 July 2021
- Published by Elsevier
Contributors
- 18 February 2021
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 93 (8) , 3898-3904
Monte Carlo Simulation Aided Quantitative Laboratory X-ray Fluorescence Analysis and Its Application in Provenancing Studies for Geo-Archeological Samples
A laboratory-based X-ray fluorescence (XRF) methodology is presented for standardless quantified analysis based on a monochromatic X-ray spectrometer coupled to Monte Carlo aided quantification. This procedure will be valuable for many scientific fields (e.g. archaeology, geology, etc.) where the unique nature of the investigated samples calls for the application of non-destructive techniques. To illustrate the value of the methodology, a case study is presented where flint artefacts from the Scheldt basin are analyzed in an attempt to provenance them. So far, little geochemical research has been done in this area. Our results contribute to the creation of a database that will help assign lithic artefacts to specific geological outcrops and will aid further research in this field.
- 18 February 2021
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 93 (8) , 3898-3904
Monte Carlo Simulation Aided Quantitative Laboratory X-ray Fluorescence Analysis and Its Application in Provenancing Studies for Geo-Archeological Samples
A laboratory-based X-ray fluorescence (XRF) methodology is presented for standardless quantified analysis based on a monochromatic X-ray spectrometer coupled to Monte Carlo aided quantification. This procedure will be valuable for many scientific fields (e.g. archaeology, geology, etc.) where the unique nature of the investigated samples calls for the application of non-destructive techniques. To illustrate the value of the methodology, a case study is presented where flint artefacts from the Scheldt basin are analyzed in an attempt to provenance them. So far, little geochemical research has been done in this area. Our results contribute to the creation of a database that will help assign lithic artefacts to specific geological outcrops and will aid further research in this field.
- 6 January 2021
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 93 (4) , 2082-2089
Quantitative Reconstruction of Polychromatic X-ray Fluorescence Computed Tomography Using Transmission Tomography
Through measuring the intensity of the fluorescence X-rays emitted by the elements of interest, X-ray fluorescence computed tomography (XFCT) is capable of mapping the elemental distribution inside an object without destructively sectioning it. With the recent advances in XFCT utilizing polychromatic microfocus X-ray sources, it is expected that the popularity of such imaging modality will rise further. However, XFCT suffers from self-absorption effects, which make it challenging to reconstruct the elemental distribution inside the sample accurately. For this reason, polychromatic XFCT is mainly used to retrieve the distribution of elements with a relatively high atomic number (Z) when compared to the matrix of the sample. To enable the quantitative reconstruction of trace and low Z elements with polychromatic XFCT, a novel reconstruction method has been proposed in this manuscript. Through examining the proposed method on both simulation data and experimental data, its capacity on retrieving the density distribution of relatively low Z elements has been confirmed.
- 6 January 2021
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 93 (4) , 2082-2089
Quantitative Reconstruction of Polychromatic X-ray Fluorescence Computed Tomography Using Transmission Tomography
Through measuring the intensity of the fluorescence X-rays emitted by the elements of interest, X-ray fluorescence computed tomography (XFCT) is capable of mapping the elemental distribution inside an object without destructively sectioning it. With the recent advances in XFCT utilizing polychromatic microfocus X-ray sources, it is expected that the popularity of such imaging modality will rise further. However, XFCT suffers from self-absorption effects, which make it challenging to reconstruct the elemental distribution inside the sample accurately. For this reason, polychromatic XFCT is mainly used to retrieve the distribution of elements with a relatively high atomic number (Z) when compared to the matrix of the sample. To enable the quantitative reconstruction of trace and low Z elements with polychromatic XFCT, a novel reconstruction method has been proposed in this manuscript. Through examining the proposed method on both simulation data and experimental data, its capacity on retrieving the density distribution of relatively low Z elements has been confirmed.
- 1 May 2020
- Published by Elsevier in Radiation Physics and Chemistry
- Vol. 170, 108622
An analytical simulation method for X-ray fluorescence computed tomography
- 1 May 2020
- Published by Elsevier in Radiation Physics and Chemistry
- Vol. 170, 108622
An analytical simulation method for X-ray fluorescence computed tomography
- 2 August 2019
- Published by American Chemical Society (ACS) in Environmental Science & Technology
- Vol. 53 (18) , 10961-10968
Correlations between As in Earthworms’ Coelomic Fluid and As Bioavailability in Highly Polluted Soils as Revealed by Combined Laboratory X-ray Techniques
Combined X-ray-based spectroscopy techniques were applied to investigate arsenic (As) bioaccumulation in earthworms (Eisenia andrei) exposed to six field-collected polluted soils (58–13 330 mg As kg–1). After 14 days of exposure to the arsenious soils, the As distribution in earthworms was examined by micro-X-ray fluorescence spectroscopy (μXRF), after epoxy resin embedding and preparing thin sections. Similar to μXRF data, XRF-computed tomography (XRF-CT) confirmed As accumulation in the coelom of intact earthworms. Therefore, total-reflection XRF was used to determine total As within both the whole earthworm’s body (AsE) and coelomic fluid extracts (AsF). Bioaccumulation data (AsE and AsF) were thereafter evaluated in relation to total As concentration in soils (AsT) and to As mobile fraction in soils. A significant linear correlation (R2 = 0.97) was found between AsE and AsF, indicating that the As sequestrated into the coelomic fluid may reflect the total body concentration. Therefore, we may conclude that the As concentration in the coelomic fluid can be used as an index of As availability. This paper demonstrates that by combining different laboratory X-ray analytical techniques, compartmentalization and bioavailability of potentially toxic elements can be visualized and quantified within indicator-living organisms, thus contributing to an improved risk assessment for contaminated soils.
- 2 August 2019
- Published by American Chemical Society (ACS) in Environmental Science & Technology
- Vol. 53 (18) , 10961-10968
Correlations between As in Earthworms’ Coelomic Fluid and As Bioavailability in Highly Polluted Soils as Revealed by Combined Laboratory X-ray Techniques
Combined X-ray-based spectroscopy techniques were applied to investigate arsenic (As) bioaccumulation in earthworms (Eisenia andrei) exposed to six field-collected polluted soils (58–13 330 mg As kg–1). After 14 days of exposure to the arsenious soils, the As distribution in earthworms was examined by micro-X-ray fluorescence spectroscopy (μXRF), after epoxy resin embedding and preparing thin sections. Similar to μXRF data, XRF-computed tomography (XRF-CT) confirmed As accumulation in the coelom of intact earthworms. Therefore, total-reflection XRF was used to determine total As within both the whole earthworm’s body (AsE) and coelomic fluid extracts (AsF). Bioaccumulation data (AsE and AsF) were thereafter evaluated in relation to total As concentration in soils (AsT) and to As mobile fraction in soils. A significant linear correlation (R2 = 0.97) was found between AsE and AsF, indicating that the As sequestrated into the coelomic fluid may reflect the total body concentration. Therefore, we may conclude that the As concentration in the coelomic fluid can be used as an index of As availability. This paper demonstrates that by combining different laboratory X-ray analytical techniques, compartmentalization and bioavailability of potentially toxic elements can be visualized and quantified within indicator-living organisms, thus contributing to an improved risk assessment for contaminated soils.
- Open Access
- 10 August 2018
- Published by Cambridge University Press (CUP) in Microscopy and Microanalysis
- Vol. 24 (S2) , 180-181
Combined 3D Chemical and Morphological Characterization Using Innovative Lab-based Equipment
- 10 August 2018
- Published by Cambridge University Press (CUP) in Microscopy and Microanalysis
- Vol. 24 (S2) , 180-181
Open AccessCombined 3D Chemical and Morphological Characterization Using Innovative Lab-based Equipment
- 10 August 2018
- Published by Cambridge University Press (CUP) in Microscopy and Microanalysis
- Vol. 24 (S2) , 242-243
The Herakles 3D X-ray Scanner: Concept, Characterization and Application Complementary to Synchrotron Radiation Based Experiments.
- 10 August 2018
- Published by Cambridge University Press (CUP) in Microscopy and Microanalysis
- Vol. 24 (S2) , 242-243
The Herakles 3D X-ray Scanner: Concept, Characterization and Application Complementary to Synchrotron Radiation Based Experiments.
- 20 September 2017
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 89 (19) , 10617-10624
Integrated Three-Dimensional Microanalysis Combining X-Ray Microtomography and X-Ray Fluorescence Methodologies
A novel 3D elemental and morphological analysis approach is presented combining X-ray computed tomography (μCT), X-ray fluorescence (XRF) tomography, and confocal XRF analysis in a single laboratory instrument (Herakles). Each end station of Herakles (μCT, XRF-CT, and confocal XRF) represents the state-of-the-art of currently available laboratory techniques. The integration of these techniques enables linking the (quantitative) spatial distribution of chemical elements within the investigated materials to their three-dimensional (3D) internal morphology/structure down to 1–10 μm resolution level, which has not been achieved so-far using laboratory X-ray techniques. The concept of Herakles relies strongly on its high precision (around 100 nm) air-bearing motor system that connects the different end-stations, allowing combined measurements based on the above X-ray techniques while retaining the coordinate system. In-house developed control and analysis software further ensures a smooth integration of the techniques. Case studies on a Cu test pattern, a Daphnia magna model organism and a perlite biocatalyst support material demonstrate the attainable resolution, elemental sensitivity of the instrument, and the strength of combining these three complementary methodologies.
- 20 September 2017
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 89 (19) , 10617-10624
Integrated Three-Dimensional Microanalysis Combining X-Ray Microtomography and X-Ray Fluorescence Methodologies
A novel 3D elemental and morphological analysis approach is presented combining X-ray computed tomography (μCT), X-ray fluorescence (XRF) tomography, and confocal XRF analysis in a single laboratory instrument (Herakles). Each end station of Herakles (μCT, XRF-CT, and confocal XRF) represents the state-of-the-art of currently available laboratory techniques. The integration of these techniques enables linking the (quantitative) spatial distribution of chemical elements within the investigated materials to their three-dimensional (3D) internal morphology/structure down to 1–10 μm resolution level, which has not been achieved so-far using laboratory X-ray techniques. The concept of Herakles relies strongly on its high precision (around 100 nm) air-bearing motor system that connects the different end-stations, allowing combined measurements based on the above X-ray techniques while retaining the coordinate system. In-house developed control and analysis software further ensures a smooth integration of the techniques. Case studies on a Cu test pattern, a Daphnia magna model organism and a perlite biocatalyst support material demonstrate the attainable resolution, elemental sensitivity of the instrument, and the strength of combining these three complementary methodologies.
- 16 March 2017
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 89 (7) , 4161-4168
Three-Dimensional Reconstruction of the Tissue-Specific Multielemental Distribution within Ceriodaphnia dubia via Multimodal Registration Using Laser Ablation ICP-Mass Spectrometry and X-ray Spectroscopic Techniques
In this work, the three-dimensional elemental distribution profile within the freshwater crustacean Ceriodaphnia dubia was constructed at a spatial resolution down to 5 μm via a data fusion approach employing state-of-the-art laser ablation-inductively coupled plasma-time-of-flight mass spectrometry (LA-ICP-TOFMS) and laboratory-based absorption microcomputed tomography (μ-CT). C. dubia was exposed to elevated Cu, Ni, and Zn concentrations, chemically fixed, dehydrated, stained, and embedded, prior to μ-CT analysis. Subsequently, the sample was cut into 5 μm thin sections that were subjected to LA-ICP-TOFMS imaging. Multimodal image registration was performed to spatially align the 2D LA-ICP-TOFMS images relative to the corresponding slices of the 3D μ-CT reconstruction. Mass channels corresponding to the isotopes of a single element were merged to improve the signal-to-noise ratios within the elemental images. In order to aid the visual interpretation of the data, LA-ICP-TOFMS data were projected onto the μ-CT voxels representing tissue. Additionally, the image resolution and elemental sensitivity were compared to those obtained with synchrotron radiation based 3D confocal μ-X-ray fluorescence imaging upon a chemically fixed and air-dried C. dubia specimen.
- 16 March 2017
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 89 (7) , 4161-4168
Three-Dimensional Reconstruction of the Tissue-Specific Multielemental Distribution within Ceriodaphnia dubia via Multimodal Registration Using Laser Ablation ICP-Mass Spectrometry and X-ray Spectroscopic Techniques
In this work, the three-dimensional elemental distribution profile within the freshwater crustacean Ceriodaphnia dubia was constructed at a spatial resolution down to 5 μm via a data fusion approach employing state-of-the-art laser ablation-inductively coupled plasma-time-of-flight mass spectrometry (LA-ICP-TOFMS) and laboratory-based absorption microcomputed tomography (μ-CT). C. dubia was exposed to elevated Cu, Ni, and Zn concentrations, chemically fixed, dehydrated, stained, and embedded, prior to μ-CT analysis. Subsequently, the sample was cut into 5 μm thin sections that were subjected to LA-ICP-TOFMS imaging. Multimodal image registration was performed to spatially align the 2D LA-ICP-TOFMS images relative to the corresponding slices of the 3D μ-CT reconstruction. Mass channels corresponding to the isotopes of a single element were merged to improve the signal-to-noise ratios within the elemental images. In order to aid the visual interpretation of the data, LA-ICP-TOFMS data were projected onto the μ-CT voxels representing tissue. Additionally, the image resolution and elemental sensitivity were compared to those obtained with synchrotron radiation based 3D confocal μ-X-ray fluorescence imaging upon a chemically fixed and air-dried C. dubia specimen.