PSPiergiorgio Sonato

Piergiorgio Sonato

*This is an algorithmically generated author record based on publicly available information.

Piergiorgio Sonato has a total of 260 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Corrigendum to “Status of SPIDER beam source after the first 3.5 years of operation” [Fusion Engineering and Design, Volume 192, July 2023, 113831]

    by M. Pavei, C. Gasparrini, G. Berton, M. Agostini, V. Candela, V. Candeloro, C. Cavallini, M. Dan, S. Denizeau, M. Fadone, et al.

  • Open Access

    Design of a large nonevaporable getter pump for the full size ITER beam source prototype

    by E. Sartori, M. Siragusa, G. Berton, C. Cavallini, S. Dal Bello, M. Fadone, L. Grando, D. Marcuzzi, D. Rizzetto, G. Serianni, et al.

    An improvement for the vacuum system of the multidriver radio frequency (RF) prototype negative ion source SPIDER has been developed, to allow operating at high RF power, while minimizing the breakdown probability on the outside of the plasma source. A first-of-its-kind large nonevaporable getter (NEG) pump, based on a modular design of 384 cartridges totaling about 350 kg of ZAO® alloy (composed by Zr-Ti-V-Al) with an installed pumping speed at a room temperature of 330 m3/s for hydrogen, will complement the existing pumping system, based on eight cryogenic pumps and four turbomolecular pumps totaling about 90 m3/s in hydrogen. The vessel pressure during absorption is expected to be between 20 and 40 mPa, while during the getter regeneration, the peak operating pressure will be around 2 Pa. The NEG pump will use an additional vessel module, with integrated thermal shields to protect the in-vessel components during activation and regeneration of the pump, to be carried out at temperatures in the range of 550–600 °C. Integrated thermal analyses were carried out to verify the low heat load on pre-existing in-vessel components with a low limit of acceptable temperature, and to provide boundary conditions for the mechanical verifications of the pump structure. The scenario of cyclic hydrogen load was calculated considering the SPIDER operation modes, the expected gas throughput, and the cumulated load to the pump, to determine the regeneration temperature and auxiliary pumping necessary to make the regeneration duration compatible with the high availability of the system. The upgrade of the auxiliary pumping system is also described, as well as the mitigation of air or water exposure risk during regeneration of the NEG pump.


  • Open Access

    Experimental Characterization of an NEG Pump of Novel Size—A Major Step toward Its Application in DEMO Neutral Beam Injectors

    by Stefan Hanke, Christian Day, Thomas Giegerich, Xueli Luo, Fabrizio Siviero, Michele Mura, Beatrice Busetto, Enrico Maccallini, Paolo Manini, Emanuele Sartori, et al.

    A future nuclear fusion plant DEMO needs neutral beam injection (NBI) systems requiring a vacuum pumping system with a very high pumping speed, in the order of several 1000 m3/s. Large customized cryopumps are actually used to meet the requirements. A promising concept for future NBI systems is based on high capacity getter materials. The ZAO® alloy, developed by SAES Getters, Italy, provides a drastically improved performance for the pumping of hydrogen compared to conventional getter materials. This paper describes the experimental characterization of a large pump of scalable size with 15 kg of ZAO® and the achieved results, in particular the systematic investigation of sorption characteristics and regeneration behaviors. Major findings include a very good repeatability of the sorption performance, a reduced pumping speed at higher pressures only above the NBI relevant level, an improved performance (+20%) with elevated getter temperature and an isotope independent sticking coefficient for hydrogen. Furthermore, improved operation experience and regeneration prediction tools have been developed. Employing the experimental results, a simulation task was performed and the sticking factor of the getter cartridge was determined with 7%.


  • Open Access

    Investigations on Caesium Dispersion and Molybdenum Coating on SPIDER Components

    by Valentina Candela, Caterina Cavallini, Claudia Gasparrini, Lidia Armelao, Valeria Candeloro, Mauro Dalla Palma, Michele Fadone, Diego Marcuzzi, Mauro Pavei, Adriano Pepato, et al.

    SPIDER is the 100 keV full-size Negative Ion Source prototype of the ITER Neutral Beam Injector, operating at Consorzio RFX in Padova, Italy. The largest Negative Ion Source in the world, SPIDER generates an RF driven plasma from which Deuterium or Hydrogen negative ions are produced and extracted. At the end of 2021, a scheduled long-term shutdown started to introduce major modifications and improvements aiming to solve issues and drawbacks identified during the first three years of SPIDER operations. The first action of the shutdown period was the disassembly and characterization of the SPIDER beam source after removal from the vacuum vessel and its placement inside the clean room. Each component was carefully assessed and catalogued, following a documented procedure. Some source components, i.e., the Plasma Grid, Extraction Grid and Bias Plate, revealed the presence of different and non-uniform red, white and green coatings that might be correlated to back-streaming positive ions impinging on grid surfaces, electrical discharges and caesium evaporation. Thus, several analyses have been carried out to understand the nature of such coatings, with the study still ongoing. The evidence of caesium evaporation and deposition on molybdenum-coated SPIDER components, such as the formation of oxides and hydroxides, is demonstrated through surface characterization analyses with the use of the Scanning Electron Microscope (SEM), X-ray Diffraction (XRD) and X-ray Photoelectron Spectroscopy (XPS).


  • Water Chemistry in Fusion Cooling Systems: Borated Water for DTT Vacuum Vessel

    by C. Gasparrini, D. Badocco, L. Di Pace, N. Terranova, P. Pastore, F. Montagner, L. Mattarozzi, R. Villari, E. Martelli, S. Roccella, et al.

    The Divertor Tokamak Test (DTT) vacuum vessel (VV) is a toroidal chamber that ensures an enclosed vacuum environment for the plasma, a confinement barrier, and temperature control. Water flows in the double-shell D-shaped VV cross-sectional structure made from stainless steel to operate at a set temperature. Beyond temperature control, the water cooling circuit needs to act as a neutron shielding media to protect the structures installed outside of the VV, namely, the superconducting coils. The shielding function is achieved due to the addition of boric acid in the water. The requirement on the borated water for the DTT VV is to have 8000-ppm B solution highly enriched in ¹⁰B (95% ¹⁰B). Given the lack of water chemistry guidelines for fusion power plants, the water chemistry requirements from fission power plants were investigated. In this work, general corrosion of stainless steel, 316L type family, in concentrated borated water solutions was investigated experimentally using metal release test. Samples were exposed to ultrapure water (UPW) and 8000-ppm B borated water at 80 °C for one week to quantify the amount of ions released in solution. 316L general corrosion was studied considering the different water chemistries, UPW versus borated water, and steels microstructures. DTT VV presents many welded joints, so general corrosion of welding-induced microstructure was here investigated compared to 316L base microstructure. The release of ions from general corrosion was found to be more influenced by water chemistry than microstructure.


  • Open Access

    Initial port integration concept for EC and NB systems in EU DEMO tokamak

    by Thomas Franke, Piero Agostinetti, Christian Bachmann, Alessandro Bruschi, Matthew Carr, Fabio Cismondi, Aljaz Cufar, H.P.L. de Esch, Gianfranco Federici, Niek Den Harder, et al.


  • Open Access

    On the Electrical and Optical Features of the Plasma Coagulation Controller Low Temperature Atmospheric Plasma Jet

    by Luigi Cordaro, Gianluca De Masi, Alessandro Fassina, Davide Mancini, Roberto Cavazzana, Daniele Desideri, Piergiorgio Sonato, Matteo Zuin, Barbara Zaniol, Emilio Martines

    We report on the electrical and optical characterization of the Plasma Coagulation Controller (PCC) device, a low temperature atmospheric plasma source for biomedical applications. This device, designed for the study of plasma-induced blood coagulation, has been developed to operate flexibly in several operational conditions, since it is possible to vary the applied voltage V p and the pulse repetition rate f in a quite wide range ( V p range: 2–12 kV, f range: 1–40 kHz). Emission spectroscopy measurements were conducted by varying the line of sight along the axis of helium and neon plasma plumes. The increase of the Reactive Oxygen and Nitrogen Species (RONS) has been observed, as one moves from inside the gas pipe to the outside, as a consequence of the gas mixture with the surrounding air. Furthermore, high-speed photographs of the plasma jet were taken, showing that the plasma is not uniformly distributed in a continuous volumetric region, the plasma being concentrated in localized structures called Pulsed Atmospheric-pressure Plasma Streams (PAPS). The propagation velocities of these objects have been examined, noting that they are not related to the propagation of ion sound waves. Rather, we provide indications that the streamer propagation speed is proportional to the electron drift velocity.


  • Open Access

    Estimate of 3D power wall loads due to Neutral Beam Injection in EU DEMO ramp-up phase

    by P. Vincenzi, J. Varje, P. Agostinetti, J.F. Artaud, T. Bolzonella, T. Kurki-Suonio, M. Mattei, P. Sonato, M. Vallar


  • Review of the Innovative H&CD Designs and the Impact of Their Configurations on the Performance of the EU DEMO Fusion Power Plant Reactor

    by T. Franke, P. Agostinetti, G. Aiello, K. Avramidis, Ch. Bachmann, A. Bruschi, G. Federici, S. Garavaglia, G. Granucci, G. Grossetti, et al.

    Heating and current drive (H&CD) systems are being investigated for a demonstration fusion power plant DEMO to deliver net electricity for the grid around 2050. Compared to ITER, which has to show the generation of 500-MW thermal power, the target of DEMO is the successful production of 300 to 500 MW electrical power to the grid and to aim for a self-sufficient tritium fuel cycle. Three H&CD systems are under development for DEMO in Europe, the electron cyclotron (EC) system, the neutral beam injection (NBI) system, and the ion cyclotron system. Based on present studies for plasma ramp-up, ramp-down, and flat top phases, to be further validated in more detailed simulations, the assumed total launched power needed from the H&CD system in DEMO is in the range of 50-100 MW, to be provided for plasma heating and control. This paper describes the design and Research and Development status of selected H&CD systems, considered for their deployment in the EU DEMO. It was always considered that different H&CD configurations and design variants will have an impact on the performances for the whole fusion plant. It shall be noted that the basis for the H&CD integrated design and system development is the actual version of the European fusion electricity roadmap. The project also elaborates on H&CD efficiency improvements which will reduce the recirculating power fraction in the future fusion power plants. Different studies under investigation will be discussed such as for NBI the photoneutralization and for EC novel concepts for gyrotron multistage-depressed collector.


  • Open Access

    Heating & current drive efficiencies, TBR and RAMI considerations for DEMO

    by T. Franke, P. Agostinetti, K. Avramidis, A. Bader, Ch. Bachmann, W. Biel, T. Bolzonella, S. Ciattaglia, M. Coleman, F. Cismondi, et al.