Brian C. Ross
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Brian C. Ross has a total of 39 co-authors. Here are the top co-authors by number of shared publications:
- James C. Costello
Department of Pharmacology, University of Colorado Anschutz Medical Campus, Aurora, USA
5 shared publications - Henry Brinkerhoff
Department of Physics, University of Washington , Seattle , WA 98195 , USA
3 shared publications - Jens H. Gundlach
Department of Physics, University of Washington, Seattle, USA
3 shared publications - Andrew H. Laszlo
Department of Physics, University of Washington, Seattle, USA
2 shared publications - Holly Weeks
Department of Biostatistics and Informatics, University of Colorado Anschutz Medical Campus, 13001 E. 17th Place, Aurora, CO, 80045, USA
2 shared publications - Hui Ge
Whitehead Institute for Biomedical Research, Cambridge, Massachusetts, United States of America
2 shared publications
Latest Publications
- 12 November 2021
- Published by Wiley in Journal of Viral Hepatitis
- Vol. 29 (2) , 147-155
Electronic nose versus quadrupole mass spectrometry for identifying viral hepatitis C patients
Hepatitis C is a leading cause of liver disease and transplantation and is a significant burden on public health worldwide. This study aimed to apply the Electronic Nose (E‐Nose) and quadrupole Mass Spectrometry (MS/MS) technologies for screening blood samples from hepatitis C patients and healthy controls. We analysed volatile organic compounds (VOCs) in the headspace over blood samples to identify those VOCs characteristic for diagnosing hepatitis C patients. The study comprised 150 acute hepatitis C patients with age range: 24–59 years, and mean age ±SD: 41.5 ± 12.8 years and 150 age‐matched healthy controls (age range: 24–51 and mean age: 40.11 ± 4.89 years) from the Hospital of the Medical Research Institute, Alexandria University, Alexandria, Egypt. Collected blood samples were analysed qualitatively and quantitatively using the E‐Nose and MS/MS techniques, respectively. Principal component analysis of the E‐Nose 10‐sensor responses accurately classified blood samples from hepatitis C patients and healthy controls. The first two principal components explained over 98.35% of the variance in signals with no false‐positive (healthy controls) or false‐negative (hepatitis C patients) results. MS/MS showed two fragmentation ions at m/z of 104 and 151 Da with the positive electrospray ionization mode (ESI+) in blood samples for hepatitis C patients, but not for healthy controls or background water samples. We identified the two specific fragmentation ions at m/z 104 and m/z 151 Da as malonic acid (MF: C3H4O4; MW: 104.06 g/mol) and monosaccharide pentose (MF: C5H10O5; MW: 150.13 g/mol) in VOCs of the headspace over blood samples for hepatitis C patients. This provides a rationale for developing diagnostic tests for hepatitis C virus based on altered trace VOCs concentrations using the relatively inexpensive, easy‐to‐use, portable and non‐invasive E‐Nose technology.
- 12 November 2021
- Published by Wiley in Journal of Viral Hepatitis
- Vol. 29 (2) , 147-155
Electronic nose versus quadrupole mass spectrometry for identifying viral hepatitis C patients
Hepatitis C is a leading cause of liver disease and transplantation and is a significant burden on public health worldwide. This study aimed to apply the Electronic Nose (E‐Nose) and quadrupole Mass Spectrometry (MS/MS) technologies for screening blood samples from hepatitis C patients and healthy controls. We analysed volatile organic compounds (VOCs) in the headspace over blood samples to identify those VOCs characteristic for diagnosing hepatitis C patients. The study comprised 150 acute hepatitis C patients with age range: 24–59 years, and mean age ±SD: 41.5 ± 12.8 years and 150 age‐matched healthy controls (age range: 24–51 and mean age: 40.11 ± 4.89 years) from the Hospital of the Medical Research Institute, Alexandria University, Alexandria, Egypt. Collected blood samples were analysed qualitatively and quantitatively using the E‐Nose and MS/MS techniques, respectively. Principal component analysis of the E‐Nose 10‐sensor responses accurately classified blood samples from hepatitis C patients and healthy controls. The first two principal components explained over 98.35% of the variance in signals with no false‐positive (healthy controls) or false‐negative (hepatitis C patients) results. MS/MS showed two fragmentation ions at m/z of 104 and 151 Da with the positive electrospray ionization mode (ESI+) in blood samples for hepatitis C patients, but not for healthy controls or background water samples. We identified the two specific fragmentation ions at m/z 104 and m/z 151 Da as malonic acid (MF: C3H4O4; MW: 104.06 g/mol) and monosaccharide pentose (MF: C5H10O5; MW: 150.13 g/mol) in VOCs of the headspace over blood samples for hepatitis C patients. This provides a rationale for developing diagnostic tests for hepatitis C virus based on altered trace VOCs concentrations using the relatively inexpensive, easy‐to‐use, portable and non‐invasive E‐Nose technology.
- Open Access
Measuring chromosome conformation by fluorescence microscopy
Measurement of in-vivo chromosome conformations (structures) in single cells is a major technological goal of structural biology. If one could identify many genetic loci in a microscope image despite the limited palette of fluorescent colors used to label them, then the conformation could be solved at some resolution by ‘connecting the dots’. Computational tools for making this reconstruction are expected to produce near-perfect reconstructions when the number of fluorescent colors is high enough, irrespective of the number of loci assayed. Here we report the first experimental test of the performance of these reconstruction algorithms and check their ability to reconstruct experimentally-measured conformations. We also demonstrate the experimental metrics needed to assess reconstruction quality. Our results indicate that current sequential FISH experiments may be close to the point where the reconstructions are nearly flawless at some distance scales.
Open AccessMeasuring chromosome conformation by fluorescence microscopy
Measurement of in-vivo chromosome conformations (structures) in single cells is a major technological goal of structural biology. If one could identify many genetic loci in a microscope image despite the limited palette of fluorescent colors used to label them, then the conformation could be solved at some resolution by ‘connecting the dots’. Computational tools for making this reconstruction are expected to produce near-perfect reconstructions when the number of fluorescent colors is high enough, irrespective of the number of loci assayed. Here we report the first experimental test of the performance of these reconstruction algorithms and check their ability to reconstruct experimentally-measured conformations. We also demonstrate the experimental metrics needed to assess reconstruction quality. Our results indicate that current sequential FISH experiments may be close to the point where the reconstructions are nearly flawless at some distance scales.
- Open Access
- 28 March 2019
- Published by F1000 Research Ltd in F1000Research
- Vol. 7, 1521
Improved inference of chromosome conformation from images of labeled loci
We previously published a method that infers chromosome conformation from images of fluorescently-tagged genomic loci, for the case when there are many loci labeled with each distinguishable color. Here we build on our previous work and improve the reconstruction algorithm to address previous limitations. We show that these improvements 1) increase the reconstruction accuracy and 2) allow the method to be used on large-scale problems involving several hundred labeled loci. Simulations indicate that full-chromosome reconstructions at 1/2 Mb resolution are possible using existing labeling and imaging technologies. The updated reconstruction code and the script files used for this paper are available at: https://github.com/heltilda/align3d.
- 28 March 2019
- Published by F1000 Research Ltd in F1000Research
- Vol. 7, 1521
Open AccessImproved inference of chromosome conformation from images of labeled loci
We previously published a method that infers chromosome conformation from images of fluorescently-tagged genomic loci, for the case when there are many loci labeled with each distinguishable color. Here we build on our previous work and improve the reconstruction algorithm to address previous limitations. We show that these improvements 1) increase the reconstruction accuracy and 2) allow the method to be used on large-scale problems involving several hundred labeled loci. Simulations indicate that full-chromosome reconstructions at 1/2 Mb resolution are possible using existing labeling and imaging technologies. The updated reconstruction code and the script files used for this paper are available at: https://github.com/heltilda/align3d.
- Open Access
- 11 March 2019
- Published by F1000 Research Ltd in F1000Research
- Vol. 7, 1521
Improved inference of chromosome conformation from images of labeled loci
We previously published a method that infers chromosome conformation from images of fluorescently-tagged genomic loci, for the case when there are many loci labeled with each distinguishable color. Here we build on our previous work and improve the reconstruction algorithm to address previous limitations. We show that these improvements 1) increase the reconstruction accuracy and 2) allow the method to be used on large-scale problems involving several hundred labeled loci. Simulations indicate that full-chromosome reconstructions at 1/2 Mb resolution are possible using existing labeling and imaging technologies. The updated reconstruction code and the script files used for this paper are available at: https://github.com/heltilda/align3d.
- 11 March 2019
- Published by F1000 Research Ltd in F1000Research
- Vol. 7, 1521
Open AccessImproved inference of chromosome conformation from images of labeled loci
We previously published a method that infers chromosome conformation from images of fluorescently-tagged genomic loci, for the case when there are many loci labeled with each distinguishable color. Here we build on our previous work and improve the reconstruction algorithm to address previous limitations. We show that these improvements 1) increase the reconstruction accuracy and 2) allow the method to be used on large-scale problems involving several hundred labeled loci. Simulations indicate that full-chromosome reconstructions at 1/2 Mb resolution are possible using existing labeling and imaging technologies. The updated reconstruction code and the script files used for this paper are available at: https://github.com/heltilda/align3d.
- Open Access
- 21 September 2018
- Published by F1000 Research Ltd in F1000Research
- Vol. 7, 1521
Improved inference of chromosome conformation from images of labeled loci
We previously published a method that infers chromosome conformation from images of fluorescently-tagged genomic loci, for the case when there are many loci labeled with each distinguishable color. Here we build on our previous work and improve the reconstruction algorithm to address previous limitations. We show that these improvements 1) increase the reconstruction accuracy and 2) allow the method to be used on large-scale problems involving several hundred labeled loci. Simulations indicate that full-chromosome reconstructions at 1/2 Mb resolution are possible using existing labeling and imaging technologies. The updated reconstruction code and the script files used for this paper are available at: https://github.com/heltilda/align3d.
- 21 September 2018
- Published by F1000 Research Ltd in F1000Research
- Vol. 7, 1521
Open AccessImproved inference of chromosome conformation from images of labeled loci
We previously published a method that infers chromosome conformation from images of fluorescently-tagged genomic loci, for the case when there are many loci labeled with each distinguishable color. Here we build on our previous work and improve the reconstruction algorithm to address previous limitations. We show that these improvements 1) increase the reconstruction accuracy and 2) allow the method to be used on large-scale problems involving several hundred labeled loci. Simulations indicate that full-chromosome reconstructions at 1/2 Mb resolution are possible using existing labeling and imaging technologies. The updated reconstruction code and the script files used for this paper are available at: https://github.com/heltilda/align3d.
- Open Access
- 7 June 2018
- Published by Springer Nature in BMC Systems Biology
- Vol. 12 (1) , 64-64:11
Simulating heterogeneous populations using Boolean models
Certain biological processes, such as the development of cancer and immune activation, can be controlled by rare cellular events that are difficult to capture computationally through simulations of individual cells. Information about such rare events can be gleaned from an attractor analysis, for which a variety of methods exist (in particular for Boolean models). However, explicitly simulating a defined mixed population of cells in a way that tracks even the rarest subpopulations remains an open challenge. Here we show that when cellular states are described using a Boolean network model, one can exactly simulate the dynamics of non-interacting, highly heterogeneous populations directly, without having to model the various subpopulations. This strategy captures even the rarest outcomes of the model with no sampling error. Our method can incorporate heterogeneity in both cell state and, by augmenting the model, the underlying rules of the network as well (e.g., introducing loss-of-function genetic alterations). We demonstrate our method by using it to simulate a heterogeneous population of Boolean networks modeling the T-cell receptor, spanning ∼ 1020 distinct cellular states and mutational profiles. We have developed a method for using Boolean models to perform a population-level simulation, in which the population consists of non-interacting individuals existing in different states. This approach can be used even when there are far too many distinct subpopulations to model individually.
- 7 June 2018
- Published by Springer Nature in BMC Systems Biology
- Vol. 12 (1) , 64-64:11
Open AccessSimulating heterogeneous populations using Boolean models
Certain biological processes, such as the development of cancer and immune activation, can be controlled by rare cellular events that are difficult to capture computationally through simulations of individual cells. Information about such rare events can be gleaned from an attractor analysis, for which a variety of methods exist (in particular for Boolean models). However, explicitly simulating a defined mixed population of cells in a way that tracks even the rarest subpopulations remains an open challenge. Here we show that when cellular states are described using a Boolean network model, one can exactly simulate the dynamics of non-interacting, highly heterogeneous populations directly, without having to model the various subpopulations. This strategy captures even the rarest outcomes of the model with no sampling error. Our method can incorporate heterogeneity in both cell state and, by augmenting the model, the underlying rules of the network as well (e.g., introducing loss-of-function genetic alterations). We demonstrate our method by using it to simulate a heterogeneous population of Boolean networks modeling the T-cell receptor, spanning ∼ 1020 distinct cellular states and mutational profiles. We have developed a method for using Boolean models to perform a population-level simulation, in which the population consists of non-interacting individuals existing in different states. This approach can be used even when there are far too many distinct subpopulations to model individually.
- Open Access
Simulating heterogeneous populations using Boolean models
Certain biological processes such as cancer development and immune activation are controlled by rare cellular events that are difficult to capture computationally through simulations of individual cells. Here we show that when cellular states are described using a Boolean network model, one can exactly simulate the dynamics of non-interacting, highly heterogeneous populations directly, without having to model the various subpopulations. This strategy captures even the rarest outcomes of the model with no sampling error. Our method can incorporate heterogeneity in both cell state and, by augmenting the model, the underlying rules of the network as well (i.e. mutations). We demonstrate our method by using it to simulate a heterogeneous population of Boolean networks modeling the T-cell receptor, spanning ~ 10 20 distinct cellular states and mutational profiles.
Open AccessSimulating heterogeneous populations using Boolean models
Certain biological processes such as cancer development and immune activation are controlled by rare cellular events that are difficult to capture computationally through simulations of individual cells. Here we show that when cellular states are described using a Boolean network model, one can exactly simulate the dynamics of non-interacting, highly heterogeneous populations directly, without having to model the various subpopulations. This strategy captures even the rarest outcomes of the model with no sampling error. Our method can incorporate heterogeneity in both cell state and, by augmenting the model, the underlying rules of the network as well (i.e. mutations). We demonstrate our method by using it to simulate a heterogeneous population of Boolean networks modeling the T-cell receptor, spanning ~ 10 20 distinct cellular states and mutational profiles.
- 1 January 2015
- Published by Elsevier in Biophysical Journal
- Vol. 108 (2) , 176a
Single-Read De Novo Sequencing Using Nanopore Mspa
- 1 January 2015
- Published by Elsevier in Biophysical Journal
- Vol. 108 (2) , 176a
Single-Read De Novo Sequencing Using Nanopore Mspa
- 1 January 2015
- Published by Elsevier in Biophysical Journal
- Vol. 108 (2) , 630a
Decoding Long Nanopore Reads of Bacteriophage Phi X 174
- 1 January 2015
- Published by Elsevier in Biophysical Journal
- Vol. 108 (2) , 630a
Decoding Long Nanopore Reads of Bacteriophage Phi X 174
- Top Cited PapersOpen Access
- 25 June 2014
- Published by Springer Nature in Nature Biotechnology
- Vol. 32 (8) , 829-833
Decoding long nanopore sequencing reads of natural DNA
Laszlo et al. demonstrate sequence alignment, and proof-of-concept organism identification, genome assembly and polymorphism detection from nanopore analysis of natural DNA. Nanopore sequencing of DNA is a single-molecule technique that may achieve long reads, low cost and high speed with minimal sample preparation and instrumentation. Here, we build on recent progress with respect to nanopore resolution and DNA control to interpret the procession of ion current levels observed during the translocation of DNA through the pore MspA. As approximately four nucleotides affect the ion current of each level, we measured the ion current corresponding to all 256 four-nucleotide combinations (quadromers). This quadromer map is highly predictive of ion current levels of previously unmeasured sequences derived from the bacteriophage phi X 174 genome. Furthermore, we show nanopore sequencing reads of phi X 174 up to 4,500 bases in length, which can be unambiguously aligned to the phi X 174 reference genome, and demonstrate proof-of-concept utility with respect to hybrid genome assembly and polymorphism detection. This work provides a foundation for nanopore sequencing of long, natural DNA strands.
- 25 June 2014
- Published by Springer Nature in Nature Biotechnology
- Vol. 32 (8) , 829-833
Top Cited PapersOpen AccessDecoding long nanopore sequencing reads of natural DNA
Laszlo et al. demonstrate sequence alignment, and proof-of-concept organism identification, genome assembly and polymorphism detection from nanopore analysis of natural DNA. Nanopore sequencing of DNA is a single-molecule technique that may achieve long reads, low cost and high speed with minimal sample preparation and instrumentation. Here, we build on recent progress with respect to nanopore resolution and DNA control to interpret the procession of ion current levels observed during the translocation of DNA through the pore MspA. As approximately four nucleotides affect the ion current of each level, we measured the ion current corresponding to all 256 four-nucleotide combinations (quadromers). This quadromer map is highly predictive of ion current levels of previously unmeasured sequences derived from the bacteriophage phi X 174 genome. Furthermore, we show nanopore sequencing reads of phi X 174 up to 4,500 bases in length, which can be unambiguously aligned to the phi X 174 reference genome, and demonstrate proof-of-concept utility with respect to hybrid genome assembly and polymorphism detection. This work provides a foundation for nanopore sequencing of long, natural DNA strands.