Tsutomu Oyama
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Tsutomu Oyama has a total of 103 co-authors. Here are the top co-authors by number of shared publications:
Takao Tsuji
Department of Electrical and Computer Engineering, Yokohama National University, Yokohama, Japan
21 shared publicationsTadahiro Goda
Department of Engineering, Doshisha University
13 shared publications- Takao Tsuji
Graduate School of Engineering, Yokohama National University
13 shared publications Takuhei Hashiguchi
Kyushu University Japan
12 shared publicationsTakao Shinji
Tokyo Gas Co., Ltd
10 shared publicationsShinsuke Tsujita
Smart Energy Technology Center Tokyo Gas Co., Ltd Japan
8 shared publications
Latest Publications
- Open Access
- 1 January 2019
- Published by Taylor & Francis in Journal of International Council on Electrical Engineering
- Vol. 9 (1) , 78-84
Reliability evaluation of power systems with massive penetration of photovoltaic generation
Recently, distributed generation using renewable energy sources such as photovoltaic (PV) generation has increased in power systems to solve environmental problems and resource exhaustion problems. However, conventional reliability evaluation methods of power systems cannot easily evaluate power systems with massive penetration of PV. The methods may not accurately evaluate overload exceeding system capacity, expansion of voltage phase difference between adjacent power systems, and voltage violation resulting from a sudden decrease in PV output due to weather conditions. Therefore, this paper proposes a new method to evaluate the supply reliability of power systems by three constraints, namely, capacity constraint, voltage phase difference constraint, and voltage magnitude difference constraint.
- 1 January 2019
- Published by Taylor & Francis in Journal of International Council on Electrical Engineering
- Vol. 9 (1) , 78-84
Open AccessReliability evaluation of power systems with massive penetration of photovoltaic generation
Recently, distributed generation using renewable energy sources such as photovoltaic (PV) generation has increased in power systems to solve environmental problems and resource exhaustion problems. However, conventional reliability evaluation methods of power systems cannot easily evaluate power systems with massive penetration of PV. The methods may not accurately evaluate overload exceeding system capacity, expansion of voltage phase difference between adjacent power systems, and voltage violation resulting from a sudden decrease in PV output due to weather conditions. Therefore, this paper proposes a new method to evaluate the supply reliability of power systems by three constraints, namely, capacity constraint, voltage phase difference constraint, and voltage magnitude difference constraint.
- 1 January 2019
- Published by Institute of Electrical Engineers of Japan (IEE Japan) in IEEJ Transactions on Power and Energy
- Vol. 139 (1) , 13-26
Three Phase Unbalance Elimination in Distribution System by Optimal Inverter Dispatch of PCS
The increasing introduction of photovoltaic (PV) units into low voltage distribution system causes serious power quality issues, e. g. voltage variation and three phase voltage unbalance (VU) which limit the rating and number of further connections. Some conventional countermeasures such as on load tap changer, step voltage regulator, etc. have been applied to mitigate the voltage problems. However, these methodologies might not be enough to cope with PV output fluctuation due to the limitation in the number of tap changing operations or slow response of tap changers. On the other hand, it seems promising to use PV inverter control to solve the problems when PV units are allowed to inject or absorb reactive power. In particular, there is a possibility that PV inverter control can contribute to VU problem even if they are connected with low voltage single phase networks. This paper proposed a comprehensive inverter control strategy consisting of both reactive power control and active power curtailment to improve the operation performance of VU in medium voltage distribution network with high penetration of residential PV systems by minimizing network losses and active power curtailment with voltage quality constraints. The effectiveness of the proposed method was evaluated in consideration of solar insolation level which affects active power generation of PVs.
- 1 January 2019
- Published by Institute of Electrical Engineers of Japan (IEE Japan) in IEEJ Transactions on Power and Energy
- Vol. 139 (1) , 13-26
Three Phase Unbalance Elimination in Distribution System by Optimal Inverter Dispatch of PCS
The increasing introduction of photovoltaic (PV) units into low voltage distribution system causes serious power quality issues, e. g. voltage variation and three phase voltage unbalance (VU) which limit the rating and number of further connections. Some conventional countermeasures such as on load tap changer, step voltage regulator, etc. have been applied to mitigate the voltage problems. However, these methodologies might not be enough to cope with PV output fluctuation due to the limitation in the number of tap changing operations or slow response of tap changers. On the other hand, it seems promising to use PV inverter control to solve the problems when PV units are allowed to inject or absorb reactive power. In particular, there is a possibility that PV inverter control can contribute to VU problem even if they are connected with low voltage single phase networks. This paper proposed a comprehensive inverter control strategy consisting of both reactive power control and active power curtailment to improve the operation performance of VU in medium voltage distribution network with high penetration of residential PV systems by minimizing network losses and active power curtailment with voltage quality constraints. The effectiveness of the proposed method was evaluated in consideration of solar insolation level which affects active power generation of PVs.
- 1 August 2018
- Published by Institute of Electrical Engineers of Japan (IEE Japan) in IEEJ Transactions on Power and Energy
- Vol. 138 (8) , 671-684
Supply and Demand Balance Control and Congestion Management by Locational Marginal Price based on Balancing Market in Power System with Wind Power Integration
In power systems with a large amount of wind power plants, the supply and demand balance control is an important issue. In particular, uncertain output fluctuation depending on weather condition gives a large impact on frequency regulation. Moreover, the wind power fluctuation causes power flow issues such as loop power flow. Thereby, proper congestion management of transmission lines with ensuring the control reserve for frequency regulation is necessary to keep the system stable under the large fluctuation of renewable energy sources. On the other hand, recently, the balancing power has been traded in balancing market worldwide in order to promote the economic balancing control. It is planned that the balancing market will be newly established in the near future also in Japan. Hence, this paper presents an application of locational marginal price (LMP) to the balancing market and an optimal method to determine the LMP in the balancing market for tertiary control considering not only supply and demand balance but also power flow issue and secondary control reserve. The proposed method was tested in IEEE 39 bus system model and its effectiveness was shown.
- 1 August 2018
- Published by Institute of Electrical Engineers of Japan (IEE Japan) in IEEJ Transactions on Power and Energy
- Vol. 138 (8) , 671-684
Supply and Demand Balance Control and Congestion Management by Locational Marginal Price based on Balancing Market in Power System with Wind Power Integration
In power systems with a large amount of wind power plants, the supply and demand balance control is an important issue. In particular, uncertain output fluctuation depending on weather condition gives a large impact on frequency regulation. Moreover, the wind power fluctuation causes power flow issues such as loop power flow. Thereby, proper congestion management of transmission lines with ensuring the control reserve for frequency regulation is necessary to keep the system stable under the large fluctuation of renewable energy sources. On the other hand, recently, the balancing power has been traded in balancing market worldwide in order to promote the economic balancing control. It is planned that the balancing market will be newly established in the near future also in Japan. Hence, this paper presents an application of locational marginal price (LMP) to the balancing market and an optimal method to determine the LMP in the balancing market for tertiary control considering not only supply and demand balance but also power flow issue and secondary control reserve. The proposed method was tested in IEEE 39 bus system model and its effectiveness was shown.
- 1 August 2018
- Published by Institute of Electrical Engineers of Japan (IEE Japan) in IEEJ Transactions on Power and Energy
- Vol. 138 (8) , 703-709
A Generation Method of Artificial Fluctuation Data of Wind Power Output Considering Smoothing Effect
To use realistic wind power fluctuation data is important in simulating frequency change of power systems. It is well known that the smoothing effect must be taken into account when generating the artificial wind power output. Therefore, this paper proposed a new method to generate fluctuation waveform considering smoothing effect based on random number to fulfill the correlation among multiple sites and autoregression model. The effectiveness of the proposed method was tested by using practical wind speed data measured in Tohoku district.
- 1 August 2018
- Published by Institute of Electrical Engineers of Japan (IEE Japan) in IEEJ Transactions on Power and Energy
- Vol. 138 (8) , 703-709
A Generation Method of Artificial Fluctuation Data of Wind Power Output Considering Smoothing Effect
To use realistic wind power fluctuation data is important in simulating frequency change of power systems. It is well known that the smoothing effect must be taken into account when generating the artificial wind power output. Therefore, this paper proposed a new method to generate fluctuation waveform considering smoothing effect based on random number to fulfill the correlation among multiple sites and autoregression model. The effectiveness of the proposed method was tested by using practical wind speed data measured in Tohoku district.
- 23 November 2016
- Published by Wiley in Electrical Engineering in Japan
- Vol. 198 (4) , 51-62
A LRT Control Method Using Sensor Information in Distribution Systems with a Large Amount of PVs and EVs
- 23 November 2016
- Published by Wiley in Electrical Engineering in Japan
- Vol. 198 (4) , 51-62
A LRT Control Method Using Sensor Information in Distribution Systems with a Large Amount of PVs and EVs
- 1 November 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1177-1182
Speedup of parallel computing by parareal method in transient stability analysis of Japanese power system
Long computation time is required for transient stability analysis of power systems because it can be expressed as combination of differential and algebraic equations. In order to finish the calculation within a practical amount of time, it is an effective approach that applying Parareal method as one of parallel computing technique to transient stability analysis. In the Parareal method, the accuracy of the result is gradually updated through iterative procedures in combination with rough estimation of entire waveform and detailed calculation for each decomposed time window. Based on the Parareal method, the authors have developed a new stability assessment method by using chaos theory. If an operating point is in unstable region, the trajectory has the chaotic property, “sensitive dependence on initial conditions”. Therefore, it is possible to assess the stability by detecting the convergence characteristics of the estimated waveform at each iterative procedure by the Parareal method. The effectiveness of the proposed method was tested by using IEEJ WEST10 system model.
- 1 November 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1177-1182
Speedup of parallel computing by parareal method in transient stability analysis of Japanese power system
Long computation time is required for transient stability analysis of power systems because it can be expressed as combination of differential and algebraic equations. In order to finish the calculation within a practical amount of time, it is an effective approach that applying Parareal method as one of parallel computing technique to transient stability analysis. In the Parareal method, the accuracy of the result is gradually updated through iterative procedures in combination with rough estimation of entire waveform and detailed calculation for each decomposed time window. Based on the Parareal method, the authors have developed a new stability assessment method by using chaos theory. If an operating point is in unstable region, the trajectory has the chaotic property, “sensitive dependence on initial conditions”. Therefore, it is possible to assess the stability by detecting the convergence characteristics of the estimated waveform at each iterative procedure by the Parareal method. The effectiveness of the proposed method was tested by using IEEJ WEST10 system model.
- 1 January 2016
- Published by Institute of Electrical Engineers of Japan (IEE Japan) in IEEJ Transactions on Power and Energy
- Vol. 136 (4) , 382-389
A Pricing Method of Reactive Power Considering Communication Function of Smart Meters in Distribution Systems
- 1 January 2016
- Published by Institute of Electrical Engineers of Japan (IEE Japan) in IEEJ Transactions on Power and Energy
- Vol. 136 (4) , 382-389
A Pricing Method of Reactive Power Considering Communication Function of Smart Meters in Distribution Systems
- 1 January 2016
- Published by Institute of Electrical Engineers of Japan (IEE Japan) in IEEJ Transactions on Power and Energy
- Vol. 136 (4) , 410-423
A Probabilistic Estimation Method of Reactive Power Controlled by PCS using Measurement Data of Switchgears with Sensors
- 1 January 2016
- Published by Institute of Electrical Engineers of Japan (IEE Japan) in IEEJ Transactions on Power and Energy
- Vol. 136 (4) , 410-423
A Probabilistic Estimation Method of Reactive Power Controlled by PCS using Measurement Data of Switchgears with Sensors
- 1 November 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Interface flow limit identification using focused time delay network for MEPS transmission
This paper investigates the use of use of Dynamic Neural Network (DNN) to extensively identify limitation of active power flow on the main transmission line for Malaysia Electric Power System (MEPS) network with PV generators provision. Conceptually, DNN is superior to Static Neural Network (SNN) in whatever errands are propounded from simple to complex systems. Compared to the conventional method using Continuous Power Flow (CPF) hereby with dynamical of neural network expedited identification of secure limitation on the network at given occasion. Namely, a Focused Time Delay Network (FTDN) which categorized as dynamic network model is developed in this study to specify the limit of active power flow over the network. Further, load variations e.g. low and high peak demand whilst considering N-1 criterion is deployed correspondingly. The simulations results are obtained using MATLAB software to identify MEPS network for inter area power transactions capability successfully presented and discussed thoroughly.
- 1 November 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Interface flow limit identification using focused time delay network for MEPS transmission
This paper investigates the use of use of Dynamic Neural Network (DNN) to extensively identify limitation of active power flow on the main transmission line for Malaysia Electric Power System (MEPS) network with PV generators provision. Conceptually, DNN is superior to Static Neural Network (SNN) in whatever errands are propounded from simple to complex systems. Compared to the conventional method using Continuous Power Flow (CPF) hereby with dynamical of neural network expedited identification of secure limitation on the network at given occasion. Namely, a Focused Time Delay Network (FTDN) which categorized as dynamic network model is developed in this study to specify the limit of active power flow over the network. Further, load variations e.g. low and high peak demand whilst considering N-1 criterion is deployed correspondingly. The simulations results are obtained using MATLAB software to identify MEPS network for inter area power transactions capability successfully presented and discussed thoroughly.
- Open Access
- 1 October 2014
- Published by Taylor & Francis in Journal of International Council on Electrical Engineering
- Vol. 4 (4) , 275-280
A Study on Feasible Region for Islanded Operation Mode in Power Systems with Distributed Generators in Emergency
– As an expected effectiveness in introducing micro-grid, there are possibilities that the microgrid can improve the electrical power supply reliability. Specifically, micro-grid with islanded operation mode can continuously supply power to loads when a fault, such as large-scale power outage, occurs at the utility grid. When the range of the small scale network which can operate independently is planned in advance, it is easier for DGs (Distributed Generators) to design desirable autonomous operation in islanded state during a grid failure in the upstream network. Inversely, under the assumption that the range of the islanded system changes depending on the fault cases, the control logic should have any robustness. Hence, in this paper, to improve the power supply reliability in small-scale distribution systems, we studied the relationship between inverter control and stability of the islanded mode. Supposing that the inverter control is based on droop characteristics, its parameters have to be adjusted considering the equivalent impedance between the inverter and the center of inertia of the remained part of the system in order to realize the stable islanded operation in various fault cases.
- 1 October 2014
- Published by Taylor & Francis in Journal of International Council on Electrical Engineering
- Vol. 4 (4) , 275-280
Open AccessA Study on Feasible Region for Islanded Operation Mode in Power Systems with Distributed Generators in Emergency
– As an expected effectiveness in introducing micro-grid, there are possibilities that the microgrid can improve the electrical power supply reliability. Specifically, micro-grid with islanded operation mode can continuously supply power to loads when a fault, such as large-scale power outage, occurs at the utility grid. When the range of the small scale network which can operate independently is planned in advance, it is easier for DGs (Distributed Generators) to design desirable autonomous operation in islanded state during a grid failure in the upstream network. Inversely, under the assumption that the range of the islanded system changes depending on the fault cases, the control logic should have any robustness. Hence, in this paper, to improve the power supply reliability in small-scale distribution systems, we studied the relationship between inverter control and stability of the islanded mode. Supposing that the inverter control is based on droop characteristics, its parameters have to be adjusted considering the equivalent impedance between the inverter and the center of inertia of the remained part of the system in order to realize the stable islanded operation in various fault cases.