Mona Nasseri
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Mona Nasseri has a total of 106 co-authors. Here are the top co-authors by number of shared publications:
- Benjamin H. Brinkmann
Department of Neurology Mayo Clinic Rochester Minnesota USA
8 shared publications - Gregory A. Worrell
Mayo Clinic
4 shared publications Shu Lin
Department of Electrical and Computer Engineering, University of California Davis, CA, USA
4 shared publications- Tal Pal Attia
Department of Neurology, Bioelectronics Neurophysiology and Engineering Laboratory Mayo Clinic Minnesota Rochester USA
4 shared publications - Vaclav Kremen
Mayo Clinic
4 shared publications Grentina Kilungeja
University of North Florida, 1 UNF Dr., Jacksonville, Florida, 32224-7699, UNITED STATES
3 shared publications
Latest Publications
- 22 October 2025
- Published by IOP Publishing in Physiological Measurement
- Vol. 46 (10) , 105004
Bidirectional analysis of seizure patterns and menstrual cycle phases extracted from physiological signals
Objective . This exploratory study investigates cyclical changes in physiological features across the menstrual cycle in women with epilepsy, focusing on their potential relationship with seizure occurrence. Approach . Nocturnal data during sleep were collected from two women with ovulatory cycles and compared with data from healthy controls, two non-ovulatory women, one postmenopausal woman, and two male patients. The aim was to characterize signal patterns across different reproductive states and to explore whether menstrual-related rhythms correspond to seizure timing. Circular statistics mapped signals onto an angular scale, allowing identification of biphasic patterns linked to ovulation, while machine learning algorithms identified ovulatory phases. Main Results . In ovulatory participants, seizure activity predominantly occurred around the late luteal and early follicular phases ( p < 0.05), and non-uniform and biphaisc trends were observed in temperature, resembling patterns in healthy participants. In contrast, individuals taking enzyme-inducing antiepileptic drugs showed disrupted physiological rhythms. Although hormonal fluctuations appear to drive cyclical patterns, additional rhythms (e.g. weekly) were also observed, suggesting multifactorial influences. Significance . These preliminary findings underscore the need to account for menstrual and other biological cycles in seizure forecasting models and provide a foundation for future studies involving larger cohorts.
- 22 October 2025
- Published by IOP Publishing in Physiological Measurement
- Vol. 46 (10) , 105004
Bidirectional analysis of seizure patterns and menstrual cycle phases extracted from physiological signals
Objective . This exploratory study investigates cyclical changes in physiological features across the menstrual cycle in women with epilepsy, focusing on their potential relationship with seizure occurrence. Approach . Nocturnal data during sleep were collected from two women with ovulatory cycles and compared with data from healthy controls, two non-ovulatory women, one postmenopausal woman, and two male patients. The aim was to characterize signal patterns across different reproductive states and to explore whether menstrual-related rhythms correspond to seizure timing. Circular statistics mapped signals onto an angular scale, allowing identification of biphasic patterns linked to ovulation, while machine learning algorithms identified ovulatory phases. Main Results . In ovulatory participants, seizure activity predominantly occurred around the late luteal and early follicular phases ( p < 0.05), and non-uniform and biphaisc trends were observed in temperature, resembling patterns in healthy participants. In contrast, individuals taking enzyme-inducing antiepileptic drugs showed disrupted physiological rhythms. Although hormonal fluctuations appear to drive cyclical patterns, additional rhythms (e.g. weekly) were also observed, suggesting multifactorial influences. Significance . These preliminary findings underscore the need to account for menstrual and other biological cycles in seizure forecasting models and provide a foundation for future studies involving larger cohorts.
- Open Access
- 24 June 2025
- Published by Association for Computing Machinery (ACM)
- p. 498-499
MAPD2: Mobile Application-based Pulmonary Disease Detector Using Electrocardiograms and Deep Learning
- 24 June 2025
- Published by Association for Computing Machinery (ACM)
- p. 498-499
Open AccessMAPD2: Mobile Application-based Pulmonary Disease Detector Using Electrocardiograms and Deep Learning
- Open Access
- 13 May 2025
- Published by Springer Nature in npj Women's Health
- Vol. 3 (1) , 1-10
Machine learning-based menstrual phase identification using wearable device data
- 13 May 2025
- Published by Springer Nature in npj Women's Health
- Vol. 3 (1) , 1-10
Open AccessMachine learning-based menstrual phase identification using wearable device data
- Open Access
- 24 April 2025
- Published by Association for Computing Machinery (ACM)
- p. 221-226
Obstructive Lung Disease Classification from Electrocardiograms Using Machine Learning
- 24 April 2025
- Published by Association for Computing Machinery (ACM)
- p. 221-226
Open AccessObstructive Lung Disease Classification from Electrocardiograms Using Machine Learning
- Open Access
Human Activity Recognition Algorithm with Physiological and Inertial Signals Fusion: Photoplethysmography, Electrodermal Activity, and Accelerometry
Inertial signals are the most widely used signals in human activity recognition (HAR) applications, and extensive research has been performed on developing HAR classifiers using accelerometer and gyroscope data. This study aimed to investigate the potential enhancement of HAR models through the fusion of biological signals with inertial signals. The classification of eight common low-, medium-, and high-intensity activities was assessed using machine learning (ML) algorithms, trained on accelerometer (ACC), blood volume pulse (BVP), and electrodermal activity (EDA) data obtained from a wrist-worn sensor. Two types of ML algorithms were employed: a random forest (RF) trained on features; and a pre-trained deep learning (DL) network (ResNet-18) trained on spectrogram images. Evaluation was conducted on both individual activities and more generalized activity groups, based on similar intensity. Results indicated that RF classifiers outperformed corresponding DL classifiers at both individual and grouped levels. However, the fusion of EDA and BVP signals with ACC data improved DL classifier performance compared to a baseline DL model with ACC-only data. The best performance was achieved by a classifier trained on a combination of ACC, EDA, and BVP images, yielding F1-scores of 69 and 87 for individual and grouped activity classifications, respectively. For DL models trained with additional biological signals, almost all individual activity classifications showed improvement (p-value < 0.05). In grouped activity classifications, DL model performance was enhanced for low- and medium-intensity activities. Exploring the classification of two specific activities, ascending/descending stairs and cycling, revealed significantly improved results using a DL model trained on combined ACC, BVP, and EDA spectrogram images (p-value < 0.05).
Open AccessHuman Activity Recognition Algorithm with Physiological and Inertial Signals Fusion: Photoplethysmography, Electrodermal Activity, and Accelerometry
Inertial signals are the most widely used signals in human activity recognition (HAR) applications, and extensive research has been performed on developing HAR classifiers using accelerometer and gyroscope data. This study aimed to investigate the potential enhancement of HAR models through the fusion of biological signals with inertial signals. The classification of eight common low-, medium-, and high-intensity activities was assessed using machine learning (ML) algorithms, trained on accelerometer (ACC), blood volume pulse (BVP), and electrodermal activity (EDA) data obtained from a wrist-worn sensor. Two types of ML algorithms were employed: a random forest (RF) trained on features; and a pre-trained deep learning (DL) network (ResNet-18) trained on spectrogram images. Evaluation was conducted on both individual activities and more generalized activity groups, based on similar intensity. Results indicated that RF classifiers outperformed corresponding DL classifiers at both individual and grouped levels. However, the fusion of EDA and BVP signals with ACC data improved DL classifier performance compared to a baseline DL model with ACC-only data. The best performance was achieved by a classifier trained on a combination of ACC, EDA, and BVP images, yielding F1-scores of 69 and 87 for individual and grouped activity classifications, respectively. For DL models trained with additional biological signals, almost all individual activity classifications showed improvement (p-value < 0.05). In grouped activity classifications, DL model performance was enhanced for low- and medium-intensity activities. Exploring the classification of two specific activities, ascending/descending stairs and cycling, revealed significantly improved results using a DL model trained on combined ACC, BVP, and EDA spectrogram images (p-value < 0.05).
- Open Access
- 19 October 2023
- Published by Frontiers Media SA in Frontiers in Network Physiology
- Vol. 3, 1227228
Analyzing physiological signals recorded with a wearable sensor across the menstrual cycle using circular statistics
This study aims to identify the most significant features in physiological signals representing a biphasic pattern in the menstrual cycle using circular statistics which is an appropriate analytic method for the interpretation of data with a periodic nature. The results can be used empirically to determine menstrual phases. A non-uniform pattern was observed in ovulating subjects, with a significant periodicity (p0.05) in mean temperature, heart rate (HR), Inter-beat Interval (IBI), mean tonic component of Electrodermal Activity (EDA), and signal magnitude area (SMA) of the EDA phasic component in the frequency domain. In contrast, non-ovulating cycles displayed a more uniform distribution (p0.05). There was a significant difference between ovulating and non-ovulating cycles (p0.05) in temperature, IBI, and EDA but not in mean HR. Selected features were used in training an Autoregressive Integrated Moving Average (ARIMA) model, using data from at least one cycle of a subject, to predict the behavior of the signal in the last cycle. By iteratively retraining the algorithm on a per-day basis, the mean temperature, HR, IBI and EDA tonic values of the next day were predicted with root mean square error (RMSE) of 0.13 ± 0.07 (C°), 1.31 ± 0.34 (bpm), 0.016 ± 0.005 (s) and 0.17 ± 0.17 (μS), respectively.- 19 October 2023
- Published by Frontiers Media SA in Frontiers in Network Physiology
- Vol. 3, 1227228
Open AccessAnalyzing physiological signals recorded with a wearable sensor across the menstrual cycle using circular statistics
This study aims to identify the most significant features in physiological signals representing a biphasic pattern in the menstrual cycle using circular statistics which is an appropriate analytic method for the interpretation of data with a periodic nature. The results can be used empirically to determine menstrual phases. A non-uniform pattern was observed in ovulating subjects, with a significant periodicity (p0.05) in mean temperature, heart rate (HR), Inter-beat Interval (IBI), mean tonic component of Electrodermal Activity (EDA), and signal magnitude area (SMA) of the EDA phasic component in the frequency domain. In contrast, non-ovulating cycles displayed a more uniform distribution (p0.05). There was a significant difference between ovulating and non-ovulating cycles (p0.05) in temperature, IBI, and EDA but not in mean HR. Selected features were used in training an Autoregressive Integrated Moving Average (ARIMA) model, using data from at least one cycle of a subject, to predict the behavior of the signal in the last cycle. By iteratively retraining the algorithm on a per-day basis, the mean temperature, HR, IBI and EDA tonic values of the next day were predicted with root mean square error (RMSE) of 0.13 ± 0.07 (C°), 1.31 ± 0.34 (bpm), 0.016 ± 0.005 (s) and 0.17 ± 0.17 (μS), respectively. - Open Access
- 8 May 2023
- Published by University of Florida George A Smathers Libraries in The International FLAIRS Conference Proceedings
- Vol. 36
Heart Murmur Classification in Phonocardiogram Representations Using Convolutional Neural Networks
Heart murmurs are sounds made by rapid blood flow in the heart. Abnormal heart murmurs can be a sign of serious heart conditions such as arrhythmia and cardiovascular diseases. Therefore, heart murmur classification is crucial for early detection of such conditions. To this end, we study the heart murmur classification problem training selected convolutional neural network (CNN) models (such as VGGNet and ResNet) using various signal representations (such as spectrogram, mel-frequency cepstral coefficient (MFCC), and shorttime Fourier transform (STFT)) of the phonocardiograms in the public PASCAL CHSC dataset. Our preliminary results show that ResNet outperforms VGGNet across all metrics and representations, consistent with the recent published works we can find in literature. Unlike some of these works, however, we see MFCC and STFT in general more effective with higher test accuracies than spectrogram across all CNN models. Looking forward, we propose to study other effective models (such as InceptionV3 and Vision Transformer) to predict heart murmur conditions in phonocardiogram representations including spectrogram, MFCC and STFT, as well as others like Wigner Ville distribution.
- 8 May 2023
- Published by University of Florida George A Smathers Libraries in The International FLAIRS Conference Proceedings
- Vol. 36
Open AccessHeart Murmur Classification in Phonocardiogram Representations Using Convolutional Neural Networks
Heart murmurs are sounds made by rapid blood flow in the heart. Abnormal heart murmurs can be a sign of serious heart conditions such as arrhythmia and cardiovascular diseases. Therefore, heart murmur classification is crucial for early detection of such conditions. To this end, we study the heart murmur classification problem training selected convolutional neural network (CNN) models (such as VGGNet and ResNet) using various signal representations (such as spectrogram, mel-frequency cepstral coefficient (MFCC), and shorttime Fourier transform (STFT)) of the phonocardiograms in the public PASCAL CHSC dataset. Our preliminary results show that ResNet outperforms VGGNet across all metrics and representations, consistent with the recent published works we can find in literature. Unlike some of these works, however, we see MFCC and STFT in general more effective with higher test accuracies than spectrogram across all CNN models. Looking forward, we propose to study other effective models (such as InceptionV3 and Vision Transformer) to predict heart murmur conditions in phonocardiogram representations including spectrogram, MFCC and STFT, as well as others like Wigner Ville distribution.
- Open Access
- 10 December 2022
- Published by Springer Nature in Scientific Reports
- Vol. 12 (1) , 1-16
Data quality evaluation in wearable monitoring
Wearable recordings of neurophysiological signals captured from the wrist offer enormous potential for seizure monitoring. Yet, data quality remains one of the most challenging factors that impact data reliability. We suggest a combined data quality assessment tool for the evaluation of multimodal wearable data. We analyzed data from patients with epilepsy from four epilepsy centers. Patients wore wristbands recording accelerometry, electrodermal activity, blood volume pulse, and skin temperature. We calculated data completeness and assessed the time the device was worn (on-body), and modality-specific signal quality scores. We included 37,166 h from 632 patients in the inpatient and 90,776 h from 39 patients in the outpatient setting. All modalities were affected by artifacts. Data loss was higher when using data streaming (up to 49% among inpatient cohorts, averaged across respective recordings) as compared to onboard device recording and storage (up to 9%). On-body scores, estimating the percentage of time a device was worn on the body, were consistently high across cohorts (more than 80%). Signal quality of some modalities, based on established indices, was higher at night than during the day. A uniformly reported data quality and multimodal signal quality index is feasible, makes study results more comparable, and contributes to the development of devices and evaluation routines necessary for seizure monitoring.
- 10 December 2022
- Published by Springer Nature in Scientific Reports
- Vol. 12 (1) , 1-16
Open AccessData quality evaluation in wearable monitoring
Wearable recordings of neurophysiological signals captured from the wrist offer enormous potential for seizure monitoring. Yet, data quality remains one of the most challenging factors that impact data reliability. We suggest a combined data quality assessment tool for the evaluation of multimodal wearable data. We analyzed data from patients with epilepsy from four epilepsy centers. Patients wore wristbands recording accelerometry, electrodermal activity, blood volume pulse, and skin temperature. We calculated data completeness and assessed the time the device was worn (on-body), and modality-specific signal quality scores. We included 37,166 h from 632 patients in the inpatient and 90,776 h from 39 patients in the outpatient setting. All modalities were affected by artifacts. Data loss was higher when using data streaming (up to 49% among inpatient cohorts, averaged across respective recordings) as compared to onboard device recording and storage (up to 9%). On-body scores, estimating the percentage of time a device was worn on the body, were consistently high across cohorts (more than 80%). Signal quality of some modalities, based on established indices, was higher at night than during the day. A uniformly reported data quality and multimodal signal quality index is feasible, makes study results more comparable, and contributes to the development of devices and evaluation routines necessary for seizure monitoring.
Seizure forecasting using minimally invasive, ultra‐long‐term subcutaneous EEG: Generalizable cross‐patient models
This study describes a generalized cross‐patient seizure‐forecasting approach using recurrent neural networks with ultra‐long‐term subcutaneous EEG (sqEEG) recordings. Data from six patients diagnosed with refractory epilepsy and monitored with an sqEEG device were used to develop a generalized algorithm for seizure forecasting using long short‐term memory (LSTM) deep‐learning classifiers. Electrographic seizures were identified by a board‐certified epileptologist. One‐minute data segments were labeled as preictal or interictal based on their relationship to confirmed seizures. Data were separated into training and testing data sets, and to compensate for the unbalanced data ratio in training, noise‐added copies of preictal data segments were generated to expand the training data set. The mean and standard deviation (SD) of the training data were used to normalize all data, preserving the pseudo‐prospective nature of the analysis. Different architecture classifiers were trained and tested using a leave‐one‐patient‐out cross‐validation method, and the area under the receiver‐operating characteristic (ROC) curve (AUC) was used to evaluate the performance classifiers. The importance of each input signal was evaluated using a leave‐one‐signal‐out method with repeated training and testing for each classifier. Cross‐patient classifiers achieved performance significantly better than chance in four of the six patients and an overall mean AUC of 0.602 ± 0.126 (mean ± SD). A time in warning of 37.386% ± 5.006% (mean ± std) and sensitivity of 0.691 ± 0.068 (mean ± std) were observed for patients with better than chance results. Analysis of input channels showed a significant contribution (p < .05) by the Fourier transform of signals channels to overall classifier performance. The relative contribution of input signals varied among patients and architectures, suggesting that the inclusion of all signals contributes to robustness in a cross‐patient classifier. These early results show that it is possible to forecast seizures training with data from different patients using two‐channel ultra‐long‐term sqEEG.
Seizure forecasting using minimally invasive, ultra‐long‐term subcutaneous EEG: Generalizable cross‐patient models
This study describes a generalized cross‐patient seizure‐forecasting approach using recurrent neural networks with ultra‐long‐term subcutaneous EEG (sqEEG) recordings. Data from six patients diagnosed with refractory epilepsy and monitored with an sqEEG device were used to develop a generalized algorithm for seizure forecasting using long short‐term memory (LSTM) deep‐learning classifiers. Electrographic seizures were identified by a board‐certified epileptologist. One‐minute data segments were labeled as preictal or interictal based on their relationship to confirmed seizures. Data were separated into training and testing data sets, and to compensate for the unbalanced data ratio in training, noise‐added copies of preictal data segments were generated to expand the training data set. The mean and standard deviation (SD) of the training data were used to normalize all data, preserving the pseudo‐prospective nature of the analysis. Different architecture classifiers were trained and tested using a leave‐one‐patient‐out cross‐validation method, and the area under the receiver‐operating characteristic (ROC) curve (AUC) was used to evaluate the performance classifiers. The importance of each input signal was evaluated using a leave‐one‐signal‐out method with repeated training and testing for each classifier. Cross‐patient classifiers achieved performance significantly better than chance in four of the six patients and an overall mean AUC of 0.602 ± 0.126 (mean ± SD). A time in warning of 37.386% ± 5.006% (mean ± std) and sensitivity of 0.691 ± 0.068 (mean ± std) were observed for patients with better than chance results. Analysis of input channels showed a significant contribution (p < .05) by the Fourier transform of signals channels to overall classifier performance. The relative contribution of input signals varied among patients and architectures, suggesting that the inclusion of all signals contributes to robustness in a cross‐patient classifier. These early results show that it is possible to forecast seizures training with data from different patients using two‐channel ultra‐long‐term sqEEG.
- 9 December 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 3599-3602
Seizure Forecasting from Subcutaneous EEG Using Long Short Term Memory Neural Networks: Algorithm Development and Optimization
Seizure forecasting is a great research interest due to its potential in helping patients manage activities or facilitate targeted therapies, specifically with the emergence of new subcutaneous continuous EEG recording systems that have shown promise to be helpful. In work presented here, we used one subject diagnosed with refractory epilepsy with 230 days of monitoring to evaluate seven architectures to design a seizure prediction algorithm using a deep learning RNN classifier. The preliminary results suggest that it is possible to forecast seizures using two-channel chronic subcutaneous EEG recordings. With an average AUC of 0.74947 for architectures found to have better than chance performance. Future work will focus on extending results to additional patients, investigating cross-subject performance, and the importance of the different inputs to the architectures.
- 9 December 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 3599-3602
Seizure Forecasting from Subcutaneous EEG Using Long Short Term Memory Neural Networks: Algorithm Development and Optimization
Seizure forecasting is a great research interest due to its potential in helping patients manage activities or facilitate targeted therapies, specifically with the emergence of new subcutaneous continuous EEG recording systems that have shown promise to be helpful. In work presented here, we used one subject diagnosed with refractory epilepsy with 230 days of monitoring to evaluate seven architectures to design a seizure prediction algorithm using a deep learning RNN classifier. The preliminary results suggest that it is possible to forecast seizures using two-channel chronic subcutaneous EEG recordings. With an average AUC of 0.74947 for architectures found to have better than chance performance. Future work will focus on extending results to additional patients, investigating cross-subject performance, and the importance of the different inputs to the architectures.