Kazuki Mizutani
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Kazuki Mizutani has a total of 266 co-authors. Here are the top co-authors by number of shared publications:
- Kentaro Hayashida
Department of Cardiology, Keio University School of Medicine, Tokyo, Japan
33 shared publications - Yusuke Watanabe
Teikyo University School of Medicine
28 shared publications Toru Naganuma
Department of Cardiology, New Tokyo Hospital, Chiba, Japan
26 shared publications- Yohei Ohno
Department of Cardiology, Tokai University, Isehara, Japan
26 shared publications Shinichi Shirai
Division of Cardiology, Kokura Memorial Hospital, Kitakyushu, Japan
22 shared publications- Masahiko Asami
Division of Cardiology, Mitsui Memorial Hospital, Tokyo, Japan
21 shared publications
Latest Publications
- Open Access
- 6 May 2026
- Published by Elsevier in JACC: Asia
- Vol. 6 (8) , 1370-1381
Atrial Fibrillation and Clinical Outcomes Following Mitral Transcatheter Edge-to-Edge Repair According to Mitral Regurgitation Etiology
- 6 May 2026
- Published by Elsevier in JACC: Asia
- Vol. 6 (8) , 1370-1381
Open AccessAtrial Fibrillation and Clinical Outcomes Following Mitral Transcatheter Edge-to-Edge Repair According to Mitral Regurgitation Etiology
- Open Access
- 22 February 2026
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 107 (6) , 1692-1700
Predicting Coronary Occlusion Risk during Redo‐TAVR at First TAVR: Asymmetric Calcification Causes Failure
Background and Aims: Predicting coronary artery occlusion due to sinus sequestration (SS) during a second transcatheter aortic valve (TAV) procedure using pre‐procedural computed tomography (CT) after the first TAV replacement (TAVR) is underreported. This study aimed to investigate the accuracy of SS risk prediction using pre‐procedural CT by comparing it to the actual SS risk observed on post‐procedural CT during TAV‐in‐TAV. Methods and Results: We retrospectively evaluated 139 consecutive patients who underwent TAVR with a balloon‐expandable valve. The predicted valve‐to‐sinotubular junction (VTSTJ) length and calcium volume of each coronary cusp were measured on pre‐procedural CT. The observed VTSTJ length was assessed on post‐procedural CT. High SS risk was defined as VTSTJ < 2.0 mm in either the right or left coronary cusp. Pre‐procedural CT classified 78 patients into the high predicted SS (PSS) risk group; 77 (98.7%) showed a high observed SS (OSS) risk on post‐procedural CT. Among the 61 patients classified as having low PSS risk, 44 (72.1%) were found to have high OSS risk post‐TAVR. In this subgroup, patients with high OSS risk had a significantly higher proportion of non‐coronary cusp calcium volume (NCC‐CV) compared to those with low OSS risk (median 48.7% [interquartile range (IQR): 42.1–55.2] vs. 39.2% [IQR: 33.7–45.4]; p = 0.004). Multivariable logistic regression revealed NCC‐CV ≥ 41.6% as an independent predictor of high OSS risk during TAV‐in‐TAV (odds ratio: 12.59 [95% confidence interval: 4.20–44.14], p < 0.001). Conclusion: Asymmetric NCC calcification was associated with discrepancies in SS predictions on pre‐procedural CT.
- 22 February 2026
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 107 (6) , 1692-1700
Open AccessPredicting Coronary Occlusion Risk during Redo‐TAVR at First TAVR: Asymmetric Calcification Causes Failure
Background and Aims: Predicting coronary artery occlusion due to sinus sequestration (SS) during a second transcatheter aortic valve (TAV) procedure using pre‐procedural computed tomography (CT) after the first TAV replacement (TAVR) is underreported. This study aimed to investigate the accuracy of SS risk prediction using pre‐procedural CT by comparing it to the actual SS risk observed on post‐procedural CT during TAV‐in‐TAV. Methods and Results: We retrospectively evaluated 139 consecutive patients who underwent TAVR with a balloon‐expandable valve. The predicted valve‐to‐sinotubular junction (VTSTJ) length and calcium volume of each coronary cusp were measured on pre‐procedural CT. The observed VTSTJ length was assessed on post‐procedural CT. High SS risk was defined as VTSTJ < 2.0 mm in either the right or left coronary cusp. Pre‐procedural CT classified 78 patients into the high predicted SS (PSS) risk group; 77 (98.7%) showed a high observed SS (OSS) risk on post‐procedural CT. Among the 61 patients classified as having low PSS risk, 44 (72.1%) were found to have high OSS risk post‐TAVR. In this subgroup, patients with high OSS risk had a significantly higher proportion of non‐coronary cusp calcium volume (NCC‐CV) compared to those with low OSS risk (median 48.7% [interquartile range (IQR): 42.1–55.2] vs. 39.2% [IQR: 33.7–45.4]; p = 0.004). Multivariable logistic regression revealed NCC‐CV ≥ 41.6% as an independent predictor of high OSS risk during TAV‐in‐TAV (odds ratio: 12.59 [95% confidence interval: 4.20–44.14], p < 0.001). Conclusion: Asymmetric NCC calcification was associated with discrepancies in SS predictions on pre‐procedural CT.
- 7 December 2025
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 107 (3) , 717-728
Prognostic Implications of Very Low‐Gradient Aortic Stenosis After Transcatheter Aortic Valve Implantation: Insights From the OCEAN‐TAVI Registry
Background: The management of very low‐gradient (LG) severe aortic stenosis (AS) remains challenging. Moreover, limited evidence exists regarding the outcomes of patients with very LG severe AS following transcatheter aortic valve implantation (TAVI). Aims: We aimed to elucidate the prognosis of patients with very LG severe AS after TAVI and the influence of flow status. Methods: Data were retrospectively collected from the OCEAN‐TAVI multicenter registry in Japan, including patients with severe AS who underwent TAVI. Results: In total, 7103 patients were classified into three groups based on their baseline mean pressure gradient (MPG): very LG (MPG ≤ 20 mmHg), LG (20 < MPG < 40 mmHg), and high‐gradient (HG) (MPG ≥ 40 mmHg). The primary endpoint was a composite of all‐cause mortality and hospitalization for heart failure. During a median follow‐up period of 741 days, the composite endpoint was reached in 2081 patients. Patients with very LG severe AS had a higher prevalence of comorbidities. Kaplan–Meier analysis showed that very LG severe AS was associated with significantly lower event‐free survival compared to that with LG and HG severe AS. Multivariable Cox regression analysis identified very LG severe AS as an independent poor prognostic indicator, regardless of the flow state. Moreover, within the very LG severe AS group, a low body mass index and myocardial infarction history were associated with worse outcomes. Conclusion: This study indicates that patients with very LG severe AS have worse prognoses compared to those with LG or HG severe AS following TAVI, regardless of the flow state.
- 7 December 2025
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 107 (3) , 717-728
Prognostic Implications of Very Low‐Gradient Aortic Stenosis After Transcatheter Aortic Valve Implantation: Insights From the OCEAN‐TAVI Registry
Background: The management of very low‐gradient (LG) severe aortic stenosis (AS) remains challenging. Moreover, limited evidence exists regarding the outcomes of patients with very LG severe AS following transcatheter aortic valve implantation (TAVI). Aims: We aimed to elucidate the prognosis of patients with very LG severe AS after TAVI and the influence of flow status. Methods: Data were retrospectively collected from the OCEAN‐TAVI multicenter registry in Japan, including patients with severe AS who underwent TAVI. Results: In total, 7103 patients were classified into three groups based on their baseline mean pressure gradient (MPG): very LG (MPG ≤ 20 mmHg), LG (20 < MPG < 40 mmHg), and high‐gradient (HG) (MPG ≥ 40 mmHg). The primary endpoint was a composite of all‐cause mortality and hospitalization for heart failure. During a median follow‐up period of 741 days, the composite endpoint was reached in 2081 patients. Patients with very LG severe AS had a higher prevalence of comorbidities. Kaplan–Meier analysis showed that very LG severe AS was associated with significantly lower event‐free survival compared to that with LG and HG severe AS. Multivariable Cox regression analysis identified very LG severe AS as an independent poor prognostic indicator, regardless of the flow state. Moreover, within the very LG severe AS group, a low body mass index and myocardial infarction history were associated with worse outcomes. Conclusion: This study indicates that patients with very LG severe AS have worse prognoses compared to those with LG or HG severe AS following TAVI, regardless of the flow state.
- Open Access
- 29 October 2025
- Published by Elsevier in JACC: Asia
- Vol. 6 (1) , 27-38
Prognostic Impact of Supranormal LVEF Following Mitral Valve TEER in Patients With Secondary Atrial MR
- 29 October 2025
- Published by Elsevier in JACC: Asia
- Vol. 6 (1) , 27-38
Open AccessPrognostic Impact of Supranormal LVEF Following Mitral Valve TEER in Patients With Secondary Atrial MR
- Open Access
- 18 August 2025
- Published by Wolters Kluwer Health in Journal of the American Heart Association
- Vol. 14 (16) , e044422
Impact of Peridevice Leak on Clinical Outcomes After Left Atrial Appendage Closure: The OCEAN‐LAAC Registry
Background: The impact of peridevice leak (PDL) at device implantation on clinical outcomes after percutaneous left atrial appendage closure (LAAC) is unknown. This study aimed to investigate the association between PDL and clinical outcomes after LAAC. Methods: Using data from the OCEAN‐LAAC (Optimized Catheter Valvular Intervention‐Left Atrial Appendage Closure) Japanese multicenter registry, we examined 1397 patients who underwent LAAC between September 2019 and December 2022. The primary outcome was transient ischemic attack, ischemic stroke, or systemic embolism within 2 years of LAAC. Clinical outcomes were compared between patients with and without PDL at device implantation using Fine and Gray multivariable regression analyses and propensity score matching. Additional analyses were performed by categorizing PDL into 2 groups: ≤3 mm and >3 mm but ≤5 mm. Results: Of 1397 patients who underwent LAAC, 84 (6.0%) had PDL, of whom 73 (86.9%) had ≤3 mm PDL. Patients with PDL had a larger left atrium and higher CHADS2 scores than those without PDL. Multivariable analyses showed that PDL was significantly associated with a higher risk of transient ischemic attack, ischemic stroke, or systemic embolism (adjusted subdistribution hazard ratio [sHR], 4.25 [95% CI, 1.91–9.44]; P P =0.016). Propensity score matching analyses revealed consistent findings. Conclusions: PDL was associated with a higher risk of transient ischemic attack, ischemic stroke, or systemic embolism, even PDL ≤3 mm. Therefore, it may be necessary to aim for no PDL as much as possible.
- 18 August 2025
- Published by Wolters Kluwer Health in Journal of the American Heart Association
- Vol. 14 (16) , e044422
Open AccessImpact of Peridevice Leak on Clinical Outcomes After Left Atrial Appendage Closure: The OCEAN‐LAAC Registry
Background: The impact of peridevice leak (PDL) at device implantation on clinical outcomes after percutaneous left atrial appendage closure (LAAC) is unknown. This study aimed to investigate the association between PDL and clinical outcomes after LAAC. Methods: Using data from the OCEAN‐LAAC (Optimized Catheter Valvular Intervention‐Left Atrial Appendage Closure) Japanese multicenter registry, we examined 1397 patients who underwent LAAC between September 2019 and December 2022. The primary outcome was transient ischemic attack, ischemic stroke, or systemic embolism within 2 years of LAAC. Clinical outcomes were compared between patients with and without PDL at device implantation using Fine and Gray multivariable regression analyses and propensity score matching. Additional analyses were performed by categorizing PDL into 2 groups: ≤3 mm and >3 mm but ≤5 mm. Results: Of 1397 patients who underwent LAAC, 84 (6.0%) had PDL, of whom 73 (86.9%) had ≤3 mm PDL. Patients with PDL had a larger left atrium and higher CHADS2 scores than those without PDL. Multivariable analyses showed that PDL was significantly associated with a higher risk of transient ischemic attack, ischemic stroke, or systemic embolism (adjusted subdistribution hazard ratio [sHR], 4.25 [95% CI, 1.91–9.44]; P P =0.016). Propensity score matching analyses revealed consistent findings. Conclusions: PDL was associated with a higher risk of transient ischemic attack, ischemic stroke, or systemic embolism, even PDL ≤3 mm. Therefore, it may be necessary to aim for no PDL as much as possible.
- Open Access
- 16 July 2025
- Published by Elsevier in JACC: Asia
- Vol. 5 (9) , 1110-1120
Early- Versus Newer-Generation Transcatheter Mitral Valve Edge-to-Edge Repair Systems
- 16 July 2025
- Published by Elsevier in JACC: Asia
- Vol. 5 (9) , 1110-1120
Open AccessEarly- Versus Newer-Generation Transcatheter Mitral Valve Edge-to-Edge Repair Systems
- Open Access
- 30 June 2025
- Published by Oxford University Press (OUP) in European Heart Journal - Case Reports
- Vol. 9 (7) , ytaf315
Transfemoral transcatheter aortic valve-in-valve implantation using endoconduit in a patient with right-sided aortic arch and complex vascular anatomy: a case report
Background: The number of transcatheter aortic valve implantation (TAVI) procedures has increased significantly and now includes younger and higher-risk surgical patients. As early-generation transcatheter heart valves (THVs) continue to degrade over time, the incidence of structural valve deterioration (SVD) is increasing, requiring more complex valve-in-valve (TAV-in-TAV) procedures. Case summary: We present a case of SVD of a THV, resulting in severe aortic regurgitation in an 88-year-old female with decompensated heart failure. Eight years prior, the patient had undergone TAVI with SAPIEN XT 23 mm via the transapical approach because of severe calcified stenosis of the lower extremity arteries and extreme tortuosity from the arch to the descending aorta and abdominal aortic aneurysm, right-sided aortic arch. Considering the patient’s condition and access route, we performed emergency transfemoral TAV-in-TAV using a 23 mm SAPIEN3 Ultra RESILIA. The endoconduit technique successfully facilitated sheath passage. The valve was implanted without complications. The procedure was successful, resulting in only trace paravalvular regurgitation. The post-operative effective orifice area was 1.80 cm² (indexed EOA: 1.32 cm²/m²). The Doppler Velocity Index was 0.59, suggesting no significant patient–prosthesis mismatch. Discussion: Vascular anomalies often restrict the choice of a safe access route in TAVI procedures. The endoconduit technique provides a minimally invasive solution for accessing complex iliac arteries. This case illustrates the importance of selecting the appropriate sheath, utilising endoconduit, and employing various procedural techniques to manage complex anatomies and ensure successful outcomes in TAV-in-TAV procedures.
- 30 June 2025
- Published by Oxford University Press (OUP) in European Heart Journal - Case Reports
- Vol. 9 (7) , ytaf315
Open AccessTransfemoral transcatheter aortic valve-in-valve implantation using endoconduit in a patient with right-sided aortic arch and complex vascular anatomy: a case report
Background: The number of transcatheter aortic valve implantation (TAVI) procedures has increased significantly and now includes younger and higher-risk surgical patients. As early-generation transcatheter heart valves (THVs) continue to degrade over time, the incidence of structural valve deterioration (SVD) is increasing, requiring more complex valve-in-valve (TAV-in-TAV) procedures. Case summary: We present a case of SVD of a THV, resulting in severe aortic regurgitation in an 88-year-old female with decompensated heart failure. Eight years prior, the patient had undergone TAVI with SAPIEN XT 23 mm via the transapical approach because of severe calcified stenosis of the lower extremity arteries and extreme tortuosity from the arch to the descending aorta and abdominal aortic aneurysm, right-sided aortic arch. Considering the patient’s condition and access route, we performed emergency transfemoral TAV-in-TAV using a 23 mm SAPIEN3 Ultra RESILIA. The endoconduit technique successfully facilitated sheath passage. The valve was implanted without complications. The procedure was successful, resulting in only trace paravalvular regurgitation. The post-operative effective orifice area was 1.80 cm² (indexed EOA: 1.32 cm²/m²). The Doppler Velocity Index was 0.59, suggesting no significant patient–prosthesis mismatch. Discussion: Vascular anomalies often restrict the choice of a safe access route in TAVI procedures. The endoconduit technique provides a minimally invasive solution for accessing complex iliac arteries. This case illustrates the importance of selecting the appropriate sheath, utilising endoconduit, and employing various procedural techniques to manage complex anatomies and ensure successful outcomes in TAV-in-TAV procedures.
- Open Access
- 27 May 2025
- Published by Elsevier in JACC: Asia
- Vol. 5 (9) , 1095-1106
Implication of the Dose of Mineralocorticoid Receptor Antagonist Following Transcatheter Edge-to-Edge Mitral Valve Repair
- 27 May 2025
- Published by Elsevier in JACC: Asia
- Vol. 5 (9) , 1095-1106
Open AccessImplication of the Dose of Mineralocorticoid Receptor Antagonist Following Transcatheter Edge-to-Edge Mitral Valve Repair
- Open Access
- 1 April 2025
- Published by Wolters Kluwer Health in Journal of the American Heart Association
- Vol. 14 (7) , e039243
Impact of Transcatheter Edge‐to‐Edge Repair in Patients With Cardiac Sarcoidosis: Insights From the OCEAN‐Mitral Registry
Background: In patients with sarcoidosis, cardiac involvement is a crucial prognostic factor leading to severe cardiovascular events. Mitral regurgitation (MR) predisposes patients to drug‐refractory heart failure; however, MR in patients with cardiac sarcoidosis (CS) has been scarcely investigated and its therapeutic approach remains unclear. This study aimed to investigate the clinical impact of transcatheter edge‐to‐edge repair in patients with CS. Methods: Patients with CS‐related ventricular functional MR were compared with those with other nonischemic cardiomyopathies in the OCEAN (Optimized Catheter Valvular Intervention)‐Mitral registry in Japan. Results: Among 1240 patients with nonischemic cardiomyopathy‐related ventricular functional MR, 40 (3.2%) had CS. Of these, 18 patients (45.0%) had immunosuppressive therapy. Twenty‐seven patients (67.5%) were New York Heart Association function class III/IV. Patients with CS were more likely to be younger and female, had a higher prevalence of ventricular tachyarrhythmia and cardiac resynchronization therapy, and had a larger left ventricle with more severe MR than the others. At the procedure, 38 patients (95.0%) had devices placed at the central lesion. All patients with CS were successfully treated, leading to immediate improvement of cardiac output. At 1‐year follow‐up, 89.3% had MR ≤2+ and 40.0% had New York Heart Association function class I. Despite similar outcomes between groups, greater remnant MR and fatal arrhythmic events in those with CS may be due to inadequate reverse remodeling and ongoing left ventricle damage caused by inflammation. Conclusions: Transcatheter edge‐to‐edge repair is an effective heart failure treatment for patients with CS‐related MR; however, the drug‐ and cardiac device‐refractory cardiomyopathy in this population warrants careful management. Registration: URL: www.umin.ac.jp/english/ ; Unique Identifier: UMIN000023653.
- 1 April 2025
- Published by Wolters Kluwer Health in Journal of the American Heart Association
- Vol. 14 (7) , e039243
Open AccessImpact of Transcatheter Edge‐to‐Edge Repair in Patients With Cardiac Sarcoidosis: Insights From the OCEAN‐Mitral Registry
Background: In patients with sarcoidosis, cardiac involvement is a crucial prognostic factor leading to severe cardiovascular events. Mitral regurgitation (MR) predisposes patients to drug‐refractory heart failure; however, MR in patients with cardiac sarcoidosis (CS) has been scarcely investigated and its therapeutic approach remains unclear. This study aimed to investigate the clinical impact of transcatheter edge‐to‐edge repair in patients with CS. Methods: Patients with CS‐related ventricular functional MR were compared with those with other nonischemic cardiomyopathies in the OCEAN (Optimized Catheter Valvular Intervention)‐Mitral registry in Japan. Results: Among 1240 patients with nonischemic cardiomyopathy‐related ventricular functional MR, 40 (3.2%) had CS. Of these, 18 patients (45.0%) had immunosuppressive therapy. Twenty‐seven patients (67.5%) were New York Heart Association function class III/IV. Patients with CS were more likely to be younger and female, had a higher prevalence of ventricular tachyarrhythmia and cardiac resynchronization therapy, and had a larger left ventricle with more severe MR than the others. At the procedure, 38 patients (95.0%) had devices placed at the central lesion. All patients with CS were successfully treated, leading to immediate improvement of cardiac output. At 1‐year follow‐up, 89.3% had MR ≤2+ and 40.0% had New York Heart Association function class I. Despite similar outcomes between groups, greater remnant MR and fatal arrhythmic events in those with CS may be due to inadequate reverse remodeling and ongoing left ventricle damage caused by inflammation. Conclusions: Transcatheter edge‐to‐edge repair is an effective heart failure treatment for patients with CS‐related MR; however, the drug‐ and cardiac device‐refractory cardiomyopathy in this population warrants careful management. Registration: URL: www.umin.ac.jp/english/ ; Unique Identifier: UMIN000023653.
- Open Access
- 25 February 2025
- Published by Elsevier in JACC: Advances
- Vol. 4 (4) , 101631
Geriatric Nutritional Risk Index Assessment in Patients Undergoing Transcatheter Edge-to-Edge Repair
- 25 February 2025
- Published by Elsevier in JACC: Advances
- Vol. 4 (4) , 101631
Open AccessGeriatric Nutritional Risk Index Assessment in Patients Undergoing Transcatheter Edge-to-Edge Repair