Erick Javier Argüello-Prada
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Erick Javier Argüello-Prada has a total of 34 co-authors. Here are the top co-authors by number of shared publications:
- Mónica Huerta
Universidad Politécnica Salesiana
3 shared publications R. Silva
Unidad de Gestión de Tecnología en Salud at Simón Bolívar University, Caracas, Venezuela
3 shared publicationsCarlos David Castaño Mosquera
Programa de Bioingeniería, Facultad de Ingeniería, Universidad Santiago de Cali, Calle 5 # 62-00 Barrio Pampalinda, Cali, 760032, Valle del Cauca, Colombia
2 shared publications- Cecilia Castillo
Instituto de Estudios Avanzados (IDEA), Caracas, Venezuela
2 shared publications - Javier Ferney Castillo García
Faculty of Engineering and Basic Sciences, Universidad Autónoma de Occidente, Cali 760035, Colombia
2 shared publications A. Gruber
1 shared publication
Latest Publications
- Open Access
- 18 May 2026
- Published by Elsevier in Biomedical Signal Processing and Control
- Vol. 123
A hierarchical rule-based algorithm for detecting premature ventricular contractions (PVCs) in the photoplethysmogram
- 18 May 2026
- Published by Elsevier in Biomedical Signal Processing and Control
- Vol. 123
Open AccessA hierarchical rule-based algorithm for detecting premature ventricular contractions (PVCs) in the photoplethysmogram
- Open Access
- 4 August 2025
- Published by Springer Nature in Physical and Engineering Sciences in Medicine
- Vol. 48 (3) , 1399-1414
Exploring supervised machine learning models to estimate blood pressure using non-fiducial features of the photoplethysmogram (PPG) and its derivatives
Machine learning has proven valuable in developing photoplethysmography (PPG)-based approaches for blood pressure (BP) estimation, with many holding some promise for cuff-less BP assessment. Still, their efficacy relies on accurate and robust fiducial point detection algorithms. The present study explores the usefulness of several non-fiducial features of the PPG signal and its derivatives in estimating BP by combining well-known feature selection methods and machine learning techniques. We collected PPG recordings from 56 participants and computed fifty-seven non-fiducial features, including statistical indexes and energy operators. After implementing three feature selection algorithms (i.e., F-test, mRMR, and ReliefF), the most relevant features were employed to train four learning regression model families. We computed the mean of all absolute errors (MAE), the squared sum and the standard deviation of the errors (MSE and RMSE, respectively), and the coefficient of determination (r 2) to evaluate the performance of each model. The abovementioned feature selection methods produced different optimal feature subsets for systolic and diastolic BP values, with the Matern 5/2 and the rational quadratic GPR models providing the best predictions when combined with ReliefF (MAE = 0.44, MSE = 0.61, and RMSE = 0.78 mmHg for SBP; MAE = 0.31, MSE = 0.40, and RMSE = 0.63 mmHg for DBP). Furthermore, each model utilizes only fifteen easy-to-compute features, thus becoming suitable for computationally constrained hardware. We highlight the need for implementing feature selection algorithms exhaustively, as the most relevant PPG-based features for systolic and diastolic BP estimation might not have the same weight.
- 4 August 2025
- Published by Springer Nature in Physical and Engineering Sciences in Medicine
- Vol. 48 (3) , 1399-1414
Open AccessExploring supervised machine learning models to estimate blood pressure using non-fiducial features of the photoplethysmogram (PPG) and its derivatives
Machine learning has proven valuable in developing photoplethysmography (PPG)-based approaches for blood pressure (BP) estimation, with many holding some promise for cuff-less BP assessment. Still, their efficacy relies on accurate and robust fiducial point detection algorithms. The present study explores the usefulness of several non-fiducial features of the PPG signal and its derivatives in estimating BP by combining well-known feature selection methods and machine learning techniques. We collected PPG recordings from 56 participants and computed fifty-seven non-fiducial features, including statistical indexes and energy operators. After implementing three feature selection algorithms (i.e., F-test, mRMR, and ReliefF), the most relevant features were employed to train four learning regression model families. We computed the mean of all absolute errors (MAE), the squared sum and the standard deviation of the errors (MSE and RMSE, respectively), and the coefficient of determination (r 2) to evaluate the performance of each model. The abovementioned feature selection methods produced different optimal feature subsets for systolic and diastolic BP values, with the Matern 5/2 and the rational quadratic GPR models providing the best predictions when combined with ReliefF (MAE = 0.44, MSE = 0.61, and RMSE = 0.78 mmHg for SBP; MAE = 0.31, MSE = 0.40, and RMSE = 0.63 mmHg for DBP). Furthermore, each model utilizes only fifteen easy-to-compute features, thus becoming suitable for computationally constrained hardware. We highlight the need for implementing feature selection algorithms exhaustively, as the most relevant PPG-based features for systolic and diastolic BP estimation might not have the same weight.
- Open Access
- 11 March 2025
- Published by IOP Publishing in Physiological Measurement
- Vol. 46 (3) , 035002
The MSPTDfast photoplethysmography beat detection algorithm: design, benchmarking, and open-source distribution
Objective: photoplethysmography is widely used for physiological monitoring, whether in clinical devices such as pulse oximeters, or consumer devices such as smartwatches. A key step in the analysis of photoplethysmogram (PPG) signals is detecting heartbeats. The multi-scale peak & trough detection (MSPTD) algorithm has been found to be one of the most accurate PPG beat detection algorithms, but is less computationally efficient than other algorithms. Therefore, the aim of this study was to develop a more efficient, open-source implementation of the MSPTD algorithm for PPG beat detection, named MSPTDfast (v.2). Approach. five potential improvements to MSPTD were identified and evaluated on four datasets. MSPTDfast (v.2) was designed by incorporating each improvement which on its own reduced execution time whilst maintaining a high F 1-score. After internal validation, MSPTDfast (v.2) was benchmarked against state-of-the-art beat detection algorithms on four additional datasets. Main results. MSPTDfast (v.2) incorporated two key improvements: pre-processing PPG signals to reduce the sampling frequency to 20 Hz; and only calculating scalogram scales corresponding to heart rates >30 bpm. During internal validation MSPTDfast (v.2) was found to have an execution time of between approximately one-third and one-twentieth of MSPTD, and a comparable F 1-score. During benchmarking MSPTDfast (v.2) was found to have the highest F 1-score alongside MSPTD, and amongst one of the lowest execution times with only MSPTDfast (v.1), qppgfast and MMPD (v.2) achieving shorter execution times. Significance. MSPTDfast (v.2) is an accurate and efficient PPG beat detection algorithm, available in an open-source Matlab toolbox.
- 11 March 2025
- Published by IOP Publishing in Physiological Measurement
- Vol. 46 (3) , 035002
Open AccessThe MSPTDfast photoplethysmography beat detection algorithm: design, benchmarking, and open-source distribution
Objective: photoplethysmography is widely used for physiological monitoring, whether in clinical devices such as pulse oximeters, or consumer devices such as smartwatches. A key step in the analysis of photoplethysmogram (PPG) signals is detecting heartbeats. The multi-scale peak & trough detection (MSPTD) algorithm has been found to be one of the most accurate PPG beat detection algorithms, but is less computationally efficient than other algorithms. Therefore, the aim of this study was to develop a more efficient, open-source implementation of the MSPTD algorithm for PPG beat detection, named MSPTDfast (v.2). Approach. five potential improvements to MSPTD were identified and evaluated on four datasets. MSPTDfast (v.2) was designed by incorporating each improvement which on its own reduced execution time whilst maintaining a high F 1-score. After internal validation, MSPTDfast (v.2) was benchmarked against state-of-the-art beat detection algorithms on four additional datasets. Main results. MSPTDfast (v.2) incorporated two key improvements: pre-processing PPG signals to reduce the sampling frequency to 20 Hz; and only calculating scalogram scales corresponding to heart rates >30 bpm. During internal validation MSPTDfast (v.2) was found to have an execution time of between approximately one-third and one-twentieth of MSPTD, and a comparable F 1-score. During benchmarking MSPTDfast (v.2) was found to have the highest F 1-score alongside MSPTD, and amongst one of the lowest execution times with only MSPTDfast (v.1), qppgfast and MMPD (v.2) achieving shorter execution times. Significance. MSPTDfast (v.2) is an accurate and efficient PPG beat detection algorithm, available in an open-source Matlab toolbox.
- Open Access
- 18 February 2025
- Published by Taylor & Francis in Cogent Engineering
- Vol. 12 (1)
Non-invasive prediction of cholesterol levels from photoplethysmogram (PPG)-based features using machine learning techniques: a proof-of-concept study
- 18 February 2025
- Published by Taylor & Francis in Cogent Engineering
- Vol. 12 (1)
Open AccessNon-invasive prediction of cholesterol levels from photoplethysmogram (PPG)-based features using machine learning techniques: a proof-of-concept study
- Open Access
Machine Learning Applied to Reference Signal-Less Detection of Motion Artifacts in Photoplethysmographic Signals: A Review
Machine learning algorithms have brought remarkable advancements in detecting motion artifacts (MAs) from the photoplethysmogram (PPG) with no measured or synthetic reference data. However, no study has provided a synthesis of these methods, let alone an in-depth discussion to aid in deciding which one is more suitable for a specific purpose. This narrative review examines the application of machine learning techniques for the reference signal-less detection of MAs in PPG signals. We did not consider articles introducing signal filtering or decomposition algorithms without previous identification of corrupted segments. Studies on MA-detecting approaches utilizing multiple channels and additional sensors such as accelerometers were also excluded. Despite its promising results, the literature on this topic shows several limitations and inconsistencies, particularly those regarding the model development and testing process and the measures used by authors to support the method’s suitability for real-time applications. Moreover, there is a need for broader exploration and validation across different body parts and a standardized set of experiments specifically designed to test and validate MA detection approaches. It is essential to provide enough elements to enable researchers and developers to objectively assess the reliability and applicability of these methods and, therefore, obtain the most out of them.
Open AccessMachine Learning Applied to Reference Signal-Less Detection of Motion Artifacts in Photoplethysmographic Signals: A Review
Machine learning algorithms have brought remarkable advancements in detecting motion artifacts (MAs) from the photoplethysmogram (PPG) with no measured or synthetic reference data. However, no study has provided a synthesis of these methods, let alone an in-depth discussion to aid in deciding which one is more suitable for a specific purpose. This narrative review examines the application of machine learning techniques for the reference signal-less detection of MAs in PPG signals. We did not consider articles introducing signal filtering or decomposition algorithms without previous identification of corrupted segments. Studies on MA-detecting approaches utilizing multiple channels and additional sensors such as accelerometers were also excluded. Despite its promising results, the literature on this topic shows several limitations and inconsistencies, particularly those regarding the model development and testing process and the measures used by authors to support the method’s suitability for real-time applications. Moreover, there is a need for broader exploration and validation across different body parts and a standardized set of experiments specifically designed to test and validate MA detection approaches. It is essential to provide enough elements to enable researchers and developers to objectively assess the reliability and applicability of these methods and, therefore, obtain the most out of them.
- Open Access
- 3 October 2024
- Published by Springer Nature in Research Square
Exploring supervised machine learning models to estimate blood pressure using non-fiducial features of the photoplethysmogram (PPG) and its derivatives
Machine learning has proven valuable in developing PPG-based approaches for blood pressure (BP) estimation, with many holding some promise for cuff-less BP assessment. Still, they depend on accurate and robust fiducial point detection algorithms to extract several features from collected signals. The present study explores the usefulness of several non-fiducial features of the PPG signal and its derivatives in estimating BP by combining well-known feature selection methods and machine learning techniques. We collected PPG recordings from 56 participants and computed fifty-seven non-fiducial features, including statistical indexes and energy operators. After implementing three feature selection algorithms (i.e., F-test, mRMR, and ReliefF), the most relevant features were employed to train four learning regression model families: linear regressions (LR), regression trees (RT), support vector regressions (SVR), and Gaussian process regressions (GPR). The abovementioned feature selection methods produced different optimal feature subsets for SBP and DBP estimation, with the Matern 5/2 and the rational quadratic GPR models providing the best predictions when combined with ReliefF (MAE = 0.44, MSE = 0.61, and RMSE = 0.78 mmHg for SBP; MAE = 0.31, MSE = 0.40, and RMSE = 0.63 mmHg for DBP). Furthermore, each model utilizes only fifteen features, many of which are relatively easy to compute, thus becoming suitable for computationally constrained hardware. We highlight the need for implementing feature selection algorithms exhaustively, as the most relevant PPG-based features for SBP estimation might not have the same weight for DBP prediction and vice versa.
- 3 October 2024
- Published by Springer Nature in Research Square
Open AccessExploring supervised machine learning models to estimate blood pressure using non-fiducial features of the photoplethysmogram (PPG) and its derivatives
Machine learning has proven valuable in developing PPG-based approaches for blood pressure (BP) estimation, with many holding some promise for cuff-less BP assessment. Still, they depend on accurate and robust fiducial point detection algorithms to extract several features from collected signals. The present study explores the usefulness of several non-fiducial features of the PPG signal and its derivatives in estimating BP by combining well-known feature selection methods and machine learning techniques. We collected PPG recordings from 56 participants and computed fifty-seven non-fiducial features, including statistical indexes and energy operators. After implementing three feature selection algorithms (i.e., F-test, mRMR, and ReliefF), the most relevant features were employed to train four learning regression model families: linear regressions (LR), regression trees (RT), support vector regressions (SVR), and Gaussian process regressions (GPR). The abovementioned feature selection methods produced different optimal feature subsets for SBP and DBP estimation, with the Matern 5/2 and the rational quadratic GPR models providing the best predictions when combined with ReliefF (MAE = 0.44, MSE = 0.61, and RMSE = 0.78 mmHg for SBP; MAE = 0.31, MSE = 0.40, and RMSE = 0.63 mmHg for DBP). Furthermore, each model utilizes only fifteen features, many of which are relatively easy to compute, thus becoming suitable for computationally constrained hardware. We highlight the need for implementing feature selection algorithms exhaustively, as the most relevant PPG-based features for SBP estimation might not have the same weight for DBP prediction and vice versa.
- Open Access
- 17 July 2024
- Published by Taylor & Francis in Cogent Education
- Vol. 11 (1)
An Arduino-based interactive tool for pain education: a pilot study
- 17 July 2024
- Published by Taylor & Francis in Cogent Education
- Vol. 11 (1)
Open AccessAn Arduino-based interactive tool for pain education: a pilot study
- Open Access
- 15 March 2022
- Published by Taylor & Francis in Cogent Engineering
- Vol. 9 (1)
A belt-like assistive device for visually impaired people: Toward a more collaborative approach
There is a large body of work focused on the development of mobility assistive devices for visually impaired (VI) people. However, none of them seems to satisfy the needs of VI people, which might suggest that these requirements have not been considered during the development process. In this sense, this study aimed to develop a novel assistive system based on the opinions provided by a group of VI persons who also participated in the performance assessment stage. Two ultrasonic sensors and one infrared sensor were combined to estimate the proximity and height of an obstacle in front of the user who acquired that information via audio messages and vibrating alerts. The proposed system was tested by twelve VI participants, who were asked to provide suggestions for improvement. Our prototype performed well indoors and achieved overall positive feedback when detecting obstacles at different heights, although it was unable to provide directional information. Future research endeavors in this field might be benefited from more collaborative participation between end-users, researchers, and institutes for VI people.
- 15 March 2022
- Published by Taylor & Francis in Cogent Engineering
- Vol. 9 (1)
Open AccessA belt-like assistive device for visually impaired people: Toward a more collaborative approach
There is a large body of work focused on the development of mobility assistive devices for visually impaired (VI) people. However, none of them seems to satisfy the needs of VI people, which might suggest that these requirements have not been considered during the development process. In this sense, this study aimed to develop a novel assistive system based on the opinions provided by a group of VI persons who also participated in the performance assessment stage. Two ultrasonic sensors and one infrared sensor were combined to estimate the proximity and height of an obstacle in front of the user who acquired that information via audio messages and vibrating alerts. The proposed system was tested by twelve VI participants, who were asked to provide suggestions for improvement. Our prototype performed well indoors and achieved overall positive feedback when detecting obstacles at different heights, although it was unable to provide directional information. Future research endeavors in this field might be benefited from more collaborative participation between end-users, researchers, and institutes for VI people.