GSGeorge Stetten

George Stetten

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


George Stetten has a total of 73 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Leveraging The Finite States of Emotion Processing to Study Late-Life Mental Health

    by Yuanzhe Huang, Saurab Faruque, Minjie Wu, Akiko Mizuno, Eduardo Diniz, Shaolin Yang, George Dewitt Stetten, Noah Schweitzer, Hecheng Jin, Linghai Wang, et al.

    Traditional approaches in mental health research apply General Linear Models (GLM) to describe the longitudinal dynamics of observed psycho-behavioral measurements (questionnaire summary scores). Similarly, GLMs are also applied to characterize relationships between neurobiological measurements (regional fMRI signals) and perceptual stimuli or other regional signals. While these methods are useful for exploring linear correlations among the isolated signals of those constructs (i.e., summary scores or fMRI signals), these classical frameworks fall short in providing insights into the comprehensive system-level dynamics underlying observable changes. Hidden Markov Models (HMM) are a statistical model that enable us to describe the sequential relations among multiple observable constructs, and when applied through the lens of Finite State Automata (FSA), can provide a more integrated and intuitive framework for modeling and understanding the underlying controller (the prescription for how to respond to inputs) that fundamentally defines any system, as opposed to linearly correlating output signals produced by the controller. We present a simple and intuitive HMM processing pipeline vcHMM (See Preliminary Data) that highlights FSA theory and is applicable for both behavioral analysis of questionnaire data and fMRI data. HMMs offer theoretic promise as they are computationally equivalent to the FSA, the control processor of a Turing Machine (TM) The dynamic programming Viterbi algorithm is used to leverage the HMM model. It efficiently identifies the most likely sequence of hidden states. The vcHMM pipeline leverages this grammar to understand how behavior and neural activity relate to depression.

  • Open Access

    Age‐ and Sex‐Related Morphological Changes in Cerebral Blood Vessels: a 7T TOF MRA Study

    by Jiatai Li, George D Stetten, Noah Schweitzer, Zonghua Shi, Tamer Ibrahim, Shaolin Yang, Bistra Iordanova, Howard J Aizenstein, Minjie Wu

    Background: In this study we evaluated age‐ and sex‐associated morphological changes of cerebral blood vessels using 7T Time‐of‐flight (TOF) magnetic resonance angiography (MRA).Method: Our study consisted of 25 cognitively normal older adults (20 female, mean age 68.2 years). Whole‐Brain TOF MRA images were collected on a 7T Siemens scanner at the University of Pittsburgh (slice number = 354, voxel size = 0.38*0.38*0.38 mm, 12 mins). An iterative vessel segmentation algorithm, VesselMapper, was used to segment blood vessels on TOF MRA images (Li et al., 2023). For each subject, vessels are further divided into large and small vessels by median split based on vessel diameters. Mean tortuosity of large vessels, small vessels and overall vessels was computed. Linear regression analyses were performed to evaluate the main effects of age and sex, and the age*sex interaction on vessel tortuosity and diameter.Result: As shown in Figure 1, we found age‐related increase in mean vessel tortuosity (greater age is associated with greater tortuosity, p<0.02). This age‐related difference is driven by small vessels (p = 0.002) rather than large vessels (p = 0.7). We also found that age is positively associated with mean voxel tortuosity (p<0.001, black line in Figure 2). Furthermore, women showed greater age‐related increase in mean arterial tortuosity, compared to men (age*sex interaction p = 0.04, Figure 2).Conclusion: Our findings validated that morphological markers of cerebral blood vessels are sensitive to aging. Small vessels in the brain are particularly vulnerable. Further, compared to men, older women are at a higher risk for cerebral small vessel disease, which may contribute to elevated SVD‐related AD risk in women.Limitation: The study has an unbalanced sample (more women than men) and a relatively modest sample size (N = 25). A cross‐sectional instead of longitudinal design was used in this analysis. Future study with a large balanced sample and a longitudinal design are required to confirm our findings.Reference: Li, Jiatai, et al. “VesselMapper ‐ A Robust Vessel Segmentation Algorithm for 3D Images.” Annual Meeting of the Organization for Human Brain Mapping. 2023


  • Open Access

    Age‐ and Sex‐Related Morphological Changes in Cerebral Blood Vessels: a 7T TOF MRA Study

    by Jiatai Li, George D Stetten, Noah Schweitzer, Zonghua Shi, Tamer Ibrahim, Shaolin Yang, Bistra Iordanova, Howard J Aizenstein, Minjie Wu

    Background: In this study we evaluated age‐ and sex‐associated morphological changes of cerebral blood vessels using 7T Time‐of‐flight (TOF) magnetic resonance angiography (MRA).Method: Our study consisted of 25 cognitively normal older adults (20 female, mean age 68.2 years). Whole‐Brain TOF MRA images were collected on a 7T Siemens scanner at the University of Pittsburgh (slice number = 354, voxel size = 0.38*0.38*0.38 mm, 12 mins). An iterative vessel segmentation algorithm, VesselMapper, was used to segment blood vessels on TOF MRA images (Li et al., 2023). For each subject, vessels are further divided into large and small vessels by median split based on vessel diameters. Mean tortuosity of large vessels, small vessels and overall vessels was computed. Linear regression analyses were performed to evaluate the main effects of age and sex, and the age*sex interaction on vessel tortuosity and diameter.Result: As shown in Figure 1, we found age‐related increase in mean vessel tortuosity (greater age is associated with greater tortuosity, p<0.02). This age‐related difference is driven by small vessels (p = 0.002) rather than large vessels (p = 0.7). We also found that age is positively associated with mean voxel tortuosity (p<0.001, black line in Figure 2). Furthermore, women showed greater age‐related increase in mean arterial tortuosity, compared to men (age*sex interaction p = 0.04, Figure 2).Conclusion: Our findings validated that morphological markers of cerebral blood vessels are sensitive to aging. Small vessels in the brain are particularly vulnerable. Further, compared to men, older women are at a higher risk for cerebral small vessel disease, which may contribute to elevated SVD‐related AD risk in women. Limitation: The study has an unbalanced sample (more women than men) and a relatively modest sample size (N = 25). A cross‐sectional instead of longitudinal design was used in this analysis. Future study with a large balanced sample and a longitudinal design are required to confirm our findings. Reference: Li, Jiatai, et al. “VesselMapper ‐ A Robust Vessel Segmentation Algorithm for 3D Images.” Annual Meeting of the Organization for Human Brain Mapping. 2023

  • Assessment of surface rendering with 1 DoF vibration

    by Oliver Snyder, Rebeka Almasi, Cathy Fang, Roberta L. Klatzky, George Stetten

    This paper describes the creation and testing of a prototype device for rendering texture, using a touch-sensitive surface consisting of a linear soft potentiometer (LSP) attached to a 3D-printed platform and mounted on the cone of a 5-inch loudspeaker. Displacement of the cone is determined by finger position along the LSP. The roughness quality of rendered textures was evaluated psychophysically: A magnitude-estimation task measured how changes in the amplitude and spatial frequency of the rendered texture translated into perceptual change. A just-noticeable difference (JND) task measured the threshold for detection of change in amplitude or frequency, proportional to a base value. Magnitude estimation demonstrated sensitivity to both variables across the physical scales presented, but with stronger effects for amplitude: A doubling of frequency led to an approximate doubling of reported magnitude, whereas a 60% increase in amplitude led to an 86% increase in magnitude. The amplitude thresholds averaged 24%, whereas the frequency thresholds were substantially higher, averaging 64% but with substantial inter-participant variability. We conclude that the device has promise for conveying a broad range of vibratory effects and hence may simulate textural variations, but additional research is necessary to further its capabilities for differentiating vibrations close in frequency.


  • FingerSight: A Vibrotactile Wearable Ring for Assistance With Locating and Reaching Objects in Peripersonal Space

    by Shantanu A. Satpute, Janet R. Canady, Roberta L. Klatzky, George D. Stetten

    This paper describes a prototype guidance system, "FingerSight," to help people without vision locate and reach to objects in peripersonal space. It consists of four evenly spaced tactors embedded into a ring worn on the index finger, with a small camera mounted on top. Computer-vision analysis of the camera image controls vibrotactile feedback, leading users to move their hand to near targets. Two experiments tested the functionality of the prototype system. The first found that participants could discriminate between five different vibrotactile sites (four individual tactors and all simultaneously) with a mean accuracy of 88.8% after initial training. In the second experiment, participants were blindfolded and instructed to move their hand wearing the device to one of four locations within arm's reach, while hand trajectories were tracked. The tactors were controlled using two different strategies: (1) repeatedly signal axis with largest error, and (2) signal both axes in alternation. Participants demonstrated essentially straight-line trajectories toward the target under both instructions, but the temporal parameters (rate of approach, duration) showed an advantage for correction on both axes in sequence.


  • Open Access

    Integrating images from a moveable tracked display of three-dimensional data

    by Gaurav Shukla, Roberta L. Klatzky, Bing Wu, Bo Wang, John Galeotti, Brian Chapmann, George Stetten

    This paper describes a novel method for displaying data obtained by three-dimensional medical imaging, by which the position and orientation of a freely movable screen are optically tracked and used in real time to select the current slice from the data set for presentation. With this method, which we call a “freely moving in-situ medical image”, the screen and imaged data are registered to a common coordinate system in space external to the user, at adjustable scale, and are available for free exploration. The three-dimensional image data occupy empty space, as if an invisible patient is being sliced by the moving screen. A behavioral study using real computed tomography lung vessel data established the superiority of the in situ display over a control condition with the same free exploration, but displaying data on a fixed screen (ex situ), with respect to accuracy in the task of tracing along a vessel and reporting spatial relations between vessel structures. A “freely moving in-situ medical image” display appears from these measures to promote spatial navigation and understanding of medical data.

  • Open Access

    One-Dimensional Haptic Rendering Using Audio Speaker with Displacement Determined by Inductance

    by Avin Khera, Randy Lee, Avi Marcovici, Zhixuan Yu, Roberta Klatzky, Mel Siegel, Sanjeev G. Shroff, George Stetten

    We report overall design considerations and preliminary results for a new haptic rendering device based on an audio loudspeaker. Our application models tissue properties during microsurgery. For example, the device could respond to the tip of a tool by simulating a particular tissue, displaying a desired compressibility and viscosity, giving way as the tissue is disrupted, or exhibiting independent motion, such as that caused by pulsations in blood pressure. Although limited to one degree of freedom and with a relatively small range of displacement compared to other available haptic rendering devices, our design exhibits high bandwidth, low friction, low hysteresis, and low mass. These features are consistent with modeling interactions with delicate tissues during microsurgery. In addition, our haptic rendering device is designed to be simple and inexpensive to manufacture, in part through an innovative method of measuring displacement by existing variations in the speaker’s inductance as the voice coil moves over the permanent magnet. Low latency and jitter are achieved by running the real-time simulation models on a dedicated microprocessor, while maintaining bidirectional communication with a standard laptop computer for user controls and data logging.


  • Open Access

    FingerSight: Fingertip Haptic Sensing of the Visual Environment

    by Samantha Horvath, John Galeotti, Bing Wu, Roberta Klatzky, Mel Siegel, George Stetten

    We present a novel device mounted on the fingertip for acquiring and transmitting visual information through haptic channels. In contrast to previous systems in which the user interrogates an intermediate representation of visual information, such as a tactile display representing a camera generated image, our device uses a fingertip-mounted camera and haptic stimulator to allow the user to feel visual features directly from the environment. Visual features ranging from simple intensity or oriented edges to more complex information identified automatically about objects in the environment may be translated in this manner into haptic stimulation of the finger. Experiments using an initial prototype to trace a continuous straight edge have quantified the user's ability to discriminate the angle of the edge, a potentially useful feature for higher levels analysis of the visual scene.


  • The OCT penlight: in-situ image guidance for microsurgery

    by John Galeotti, Areej Sajjad, Bo Wang, Larry Kagemann, Gaurav Shukla, Mel Siegel, Bing Wu, Roberta Klatzky, Gadi Wollstein, Joel S. Schuman, et al.

    We have developed a new image-based guidance system for microsurgery using optical coherence tomography (OCT), which presents a virtual image in its correct location inside the scanned tissue. Applications include surgery of the cornea, skin, and other surfaces below which shallow targets may advantageously be displayed for the naked eye or low-power magnification by a surgical microscope or loupes (magnifying eyewear). OCT provides real-time highresolution (3 micron) images at video rates within a two or more millimeter axial range in soft tissue, and is therefore suitable for guidance to various shallow targets such as Schlemm's canal in the eye (for treating Glaucoma) or skin tumors. A series of prototypes of the "OCT penlight" have produced virtual images with sufficient resolution and intensity to be useful under magnification, while the geometrical arrangement between the OCT scanner and display optics (including a half-silvered mirror) permits sufficient surgical access. The two prototypes constructed thus far have used, respectively, a miniature organic light emitting diode (OLED) display and a reflective liquid crystal on silicon (LCoS) display. The OLED has the advantage of relative simplicity, satisfactory resolution (15 micron), and color capability, whereas the LCoS can produce an image with much higher intensity and superior resolution (12 micron), although it is monochromatic and more complicated optically. Intensity is a crucial limiting factor, since light flux is greatly diminished with increasing magnification, thus favoring the LCoS as the more practical system.