Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Alicia L. Garcia-Costa has a total of 52 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Biochar-Supported Lanthanide Oxides as Photocatalysts for UV-Assisted Catalytic Wet Peroxide Oxidation of Pharmaceuticals at Circumneutral pH

    by Virginia Muelas-Ramos, Alicia L. Garcia-Costa, Javier Martín-Bueno, Christian De Los Rios, Antonio Gascó, Daphne Hermosilla

    Biochar-supported rare earth oxides are herein assessed as heterogeneous catalysts for the UV-assisted Catalytic Wet Peroxide Oxidation (UV-CWPO) treatment of pharmaceuticals under mild conditions. Catalysts were synthesized by two different pyrolysis methods (activated carbon-assisted oxygen-limited pyrolysis in a muffle furnace, and inert-gas pyrolysis in a tubular furnace under nitrogen flow), and characterized by XRD, SEM, and N2 adsorption–desorption isotherms. Their performance in assisting 385 nm UVA-LED CWPO treatment of acetaminophen (ACE), diclofenac (DCF), and metamizole (MTZ) was assessed under circumneutral pH conditions. The biochar-supported cerium-loaded catalyst prepared by oxygen-limited pyrolysis reported the highest activity, achieving 80% ACE and 70% DCF removals within 120 min of treatment, whereas MTZ was completely removed in less than 10 min, with only 16% of the removal attributable to adsorption. Superoxide radicals dominated the degradation mechanism, and photogenerated holes and hydroxyl radicals contributed moderately. Catalyst stability (minimal activity loss and negligible cerium leaching) was confirmed over five consecutive reuses. Degradation efficiency decreased ≈12–18% because of radical scavenging losses caused by the content of inorganic ions and organic matter in tap, river, and WWTP effluent waters. Treated effluents addressed lower toxicity than untreated solutions, reinforcing the environmental safety of this treatment strategy.

  • Open Access

    Electrochemical Anodic Oxidation Treatment of Pool Water Containing Cyanuric Acid

    by Jaime Carbajo, Jefferson E. Silveira, Inês Gomes, Annabel Fernandes, Lurdes Ciríaco, Alicia L. García-Costa, Juan A. Zazo, Jose A. Casas

    Cyanuric acid (CYA) is widely used as a chlorine stabilizer in swimming pools, but concentrations above 75 mg L−1 cause overstabilization and loss of disinfection capacity. This study evaluated CYA removal by advanced oxidation processes, including heterogeneous photocatalysis, photo-Fenton, photo-persulfate, and anodic oxidation (AO). AO with boron-doped diamond anodes proved most effective, achieving up to 90% total organic carbon removal in ultrapure water. When applied to real swimming pool samples (118 and 251 mg L−1 CYA), the process achieved significant CYA abatement, demonstrating its potential as a practical strategy to control overstabilization without additional chemicals.

  • Open Access

    Novel Pd-decorated graphite electrodes for perfluorooctanoic acid degradation in aqueous phase

    by Alicia L. Garcia-Costa, Andre Savall, Juan A. Zazo, Karine Groenen-Serrano, Jose A. Casas


  • Open Access

    Solar Photo-Fenton: An Effective Method for MCPA Degradation

    by Alicia Martin-Montero, Argyro Maria Zapanti, Gema Pliego, Jose A. Casas, Alicia L. Garcia-Costa

    The extensive use of herbicide 2-methyl-4-chlorophenoxyacetic acid (MCPA), coupled with its limited biodegradability, has led to its ubiquitous presence in aquatic environments. This work investigates the removal of MCPA (100 mg/L) in the aqueous phase via solar photo-Fenton. The process was carried out in a 700 mL reactor using a Xe lamp that simulates solar radiation (λ: 250–700 nm). A parametric study was conducted to assess the influence of dissolved O2 on the reaction medium, Fe2+ dosage, H2O2 concentration and pH0. The results indicate that dissolved O2 boosts pollutant mineralization, even working at sub-stoichiometric H2O2 concentrations. Under optimal reaction conditions ([Fe2+]: 7.5 mg/L, [H2O2]0: 322 mg/L (stoichiometric dose), pH0: 3.5), the MCPA reached almost complete mineralization (XTOC: 98.40%) in 180 min. Phytotoxicity and ecotoxicity assessments of treated effluents revealed that even working at sub-stoichiometric H2O2 dosages, toxicity decreases with the solar photo-Fenton treatment. Finally, the solar photo-Fenton process was evaluated in relevant matrices (river water and WWTP secondary effluent) and a realistic pollutant concentration (100 µg/L). In all cases, the pollutant degradation was ≥70% in 60 min, demonstrating the potential of this technology as a tertiary treatment.


  • Open Access

    Adsorption Technologies for the Removal of Cytostatics in Water: A Review

    by Alicia L. Garcia-Costa, Teresa I. A. Gouveia, Arminda Alves, Mónica S. F. Santos

    One of the most common treatments for cancer disease requires the administration of cytostatics, which are very effective drugs in the elimination of cancerous cells, but are toxic for healthy tissues. After being administered to patients, they are excreted and frequently reach natural water bodies, due to their poor degradation in wastewater treatment plants (WWTPs), posing a global threat to the environment and human health. The study of proper treatment approaches for the effective removal of these hazardous drugs in WWTPs is thus a topic of concern and of utmost importance to ensure environmental integrity, resilience and sustainability. The aim of this work is to perform a comprehensive review of the application of adsorption-based processes for the treatment of aqueous matrices contaminated with cytostatics, which has never been addressed before. A detailed discussion on the operating conditions, type and concentrations of sorbents used, toxicity of the effluents and other relevant parameters is presented. This paper aims to help identify the most promising sorbents and conditions, the current knowledge gaps, and future challenges/perspectives on adsorption technologies (isolated or coupled with other processes) to tackle the problem of cytostatic fingerprints in water courses. Additionally, information concerning the implementation of these technologies from an environmental and economic (life cycle assessment) perspective is given.


  • Intensification strategies for cytostatics degradation by ozone-based processes in aqueous phase

    by Alicia L. Garcia-Costa, Teresa I.A. Gouveia, M. Fernando R. Pereira, Adrián M.T. Silva, Luís M. Madeira, Arminda Alves, Mónica S.F. Santos


  • Ozonation of cytostatic drugs in aqueous phase

    by Alicia L. Garcia-Costa, Teresa I.A. Gouveia, M. Fernando R. Pereira, Adrián M.T. Silva, Arminda Alves, Luís M. Madeira, Mónica S.F. Santos


  • Open Access

    Multi-Matrix Approach for the Analysis of Bicalutamide Residues in Oncology Centers by HPLC–FLD

    by M. Francisca Portilha-Cunha, Teresa I. A. Gouveia, Alicia L. Garcia-Costa, Arminda Alves, Mónica S. F. Santos

    Cytostatics are toxic pharmaceuticals, whose presence in surfaces puts healthcare workers at risk. These drugs might also end up in hospital effluents (HWW), potentially damaging aquatic ecosystems. Bicalutamide is a cytostatic extensively consumed worldwide, but few analytical methods exist for its quantification and most of them require advanced techniques, such as liquid chromatography mass spectrometry (LC-MS), which are very complex and expensive for large monitoring studies. Therefore, a simple but reliable multi-matrix high performance liquid chromatographic method, with fluorescence detection, was developed and validated to rapidly screen abnormal concentrations of bicalutamide in HWW and relevant contamination levels of bicalutamide in indoor surfaces (>100 pg/cm2), prior to confirmation by LC-MS. The method presents good linearity and relatively low method detection limits (HWW: 0.14 ng/mL; surfaces: 0.28 pg/cm2). Global uncertainty was below 20% for concentrations higher than 25 ng/mL (HWW) and 50 pg/cm2 (surfaces); global uncertainty was little affected by the matrix. Therefore, a multi-matrix assessment could be achieved with this method, thus contributing to a holistic quantification of bicalutamide along the cytostatic circuit. Bicalutamide was not detected in any of the grab samples from a Portuguese hospital, but an enlarged sampling is required to conclude about its occurrence and exposure risks.