Maria Vinas

Maria Vinas

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Maria Vinas has a total of 63 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Extended defocus tolerance for image quality in two-photon vision

    by Oliwia Kaczkoś, Mateusz Grochalski, Maria Vinas-Pena, Maciej Wojtkowski, Jacek Pniewski, Katarzyna Komar

    Two-photon vision represents a novel area of research in vision science. The phenomenon relies on the perception of pulsed infrared light (800–1300 nm) through two-photon absorption in visual pigments, leading to the perception of color corresponding to approximately half of the stimulating wavelength. The potential applications of this effect require a quantitative assessment of the impact of defocus on perceived image quality. Here, we quantify the range of defocus over which image quality in two-photon vision is preserved. We demonstrate that two-photon vision is characterized by a greater tolerance to defocus, enabling high image quality. It may reduce accommodative activation to two-photon stimuli, leading to lower accommodative fatigue in two-photon AR displays.


  • Adaptive optics visual simulators: wavefront control to manipulate vision

    by Susana Marcos, Lucie Sawides, María Viñas Peña, Sara Aissati

    The human eye has aberrations that degrade the quality of vision. Adaptive Optics visual simulators allow closed-loop correction of the eye’s wave aberrations to produce diffraction-limited retinal image quality, or to manipulate the optics of the eye to probe the spatial limits of vision and neural adaptation. On the other hand, the wave aberrations can be controlled to expand depth-of-focus or provide multiple foci in eyes that have lost the ability to accommodate (presbyopia) and more recently to slow down myopia progression. We will present different wavefront control strategies (deformable mirrors, spatial light modulators and opto-tunable lenses) in visual simulators, and measured effects of correction and induction of wave aberrations and multifocal phase maps on visual function and perception.

  • Open Access

    Innovative Approaches for Organizing an Inclusive Optics and Photonics Conference in Virtual Format

    by Alba de Las Heras, Ana I. Gómez-Varela, María-Baralida Tomás, Rosa Ana Perez-Herrera, Luis Alberto Sánchez, Francesca Gallazzi, Beatriz Santamaría Fernández, Mario Garcia-Lechuga, Maria Vinas-Pena, Martina Delgado-Pinar, et al.

    The COVID pandemic is forcing the renewal of scientific conferences, offering opportunities to introduce technological and inclusive developments. Our analysis focuses on the implementation of inclusive practices for female and early-career researchers in a virtual scientific conference. This organization approach was applied in the XIII Spanish Optical Meeting (RNO2021), which was also characterized by avatars interacting in an online metaverse. The effectiveness of inclusive policies and novel technological tools was evaluated using the participation data and a post-conference survey. Our study reveals the high impact of inclusive actions and a strong interest in the scientific community to explore conference advances.


  • Accommodation through simulated multifocal optics

    by Shrilekha Vedhakrishnan, Alberto de Castro, Maria Vinas, Sara Aissati, Susana Marcos

    We evaluated the interaction of multifocal patterns with eye’s accommodation. Seven patterns were mapped on the spatial light modulator and the deformable mirror of an adaptive optics visual simulator, and projected onto the subjects’ eyes, representing different contact lens designs: NoLens, Bifocal Center Distance (+2.50D), Bifocal Center Near (+2.50D) and Multifocal Center Near-MediumAdd (+1.75D) and Center Near HighAdd (+2.50D), positive and negative spherical aberration (±1µm). The change in spherical aberration and the accommodative response to accommodative demands were obtained from Hartmann-Shack measurements. Positive spherical aberration and Center Distance designs are consistent with a higher accommodative response (p=0.001 & p=0.003): steeper shift of SA towards negative values and lower accommodative lag.


  • In situ measurement of the stiffness increase in the posterior sclera after UV-riboflavin crosslinking by optical coherence elastography

    by Maria Vinas-Pena, Xu Feng, Guo-Yang Li, Seok-Hyun Yun

    Scleral crosslinking may provide a way to prevent or treat myopia by stiffening scleral tissues. The ability to measure the stiffness of scleral tissues in situ pre and post scleral crosslinking would be useful but has not been established. Here, we tested the feasibility of optical coherence elastography (OCE) to measure shear modulus of scleral tissues and evaluate the impact of crosslinking on different posterior scleral regions using ex vivo porcine eyes as a model. From measured elastic wave speeds at 6 - 16 kHz, we obtained out-of-plane shear modulus value of 0.71 ± 0.12 MPa (n = 20) for normal porcine scleral tissues. After riboflavin-assisted UV crosslinking, the shear modulus increased to 1.50 ± 0.39 MPa (n = 20). This 2-fold change was consistent with the increase of static Young’s modulus from 5.5 ± 1.1 MPa to 9.3 ± 1.9 MPa after crosslinking, which we measured using conventional uniaxial extensometry on tissue stripes. OCE revealed regional stiffness differences across the temporal, nasal, and deeper posterior sclera. Our results show the potential of OCE as a noninvasive tool to evaluate the effect of scleral crosslinking.


  • Open Access

    Understanding In Vivo Chromatic Aberrations in Pseudophakic Eyes Using on Bench and Computational Approaches

    by Maria Vinas-Pena, Alberto de Castro, Carlos Dorronsoro, Ana Gonzalez-Ramos, Suad Redzovic, Nicolas Willet, Nuria Garzon, Susana Marcos

    Diffractive multifocal intraocular lenses (IOLs) modulate chromatic aberration and reduce it at certain distances due to interactions between the refractive and diffractive chromatic components. However, the extent to which computer modeling and on bench measurements of IOL chromatic aberration translate to chromatic aberration in patients implanted with these multifocal IOLs (MIOLs) is not yet fully understood. In this study, we compare the chromatic difference of focus and longitudinal chromatic aberrations in pseudophakic patients implanted with different IOL designs (monofocal and trifocal IOLs) and materials (hydrophobic and hydrophilic), and compared them with predictions from computer eye models and on bench measurements with the same IOLs. Patient data consisted of results from 63 pseudophakic eyes reported in four different studies and obtained psychophysically in the visual testing channel of a custom-developed polychromatic adaptive optics system. Computational predictions were obtained using ray tracing on computer eye models, and modulation transfer function (MTF) on bench measurements on physical eye models. We found that LCA (in vivo/simulated) for far vision was 1.37 ± 0.08 D/1.19 D for monofocal hydrophobic, 1.21 ± 0.08 D/0.88 D for monofocal hydrophilic, 0.99 ± 0.06 D/1.19 D for MIOL hydrophobic, and 0.82 ± 0.05 D/0.88 D for MIOL hydrophilic. For intermediate and near vision, LCA (in vivo/simulated) was 0.67 ± 0.10 D/0.75 D and 0.23 ± 0.08 D/0.19 D for MIOL hydrophobic and 0.27 ± 0.15 D/0.38 D and 0.15 ± 0.15 D/−0.13 D for MIOL hydrophilic, respectively. In conclusion, computational ray tracing and on bench measurements allowed for evaluating in vivo chromatic aberration with different materials and designs for multifocal diffractive intraocular lenses.


  • Open Access

    Matching convolved images to optically blurred images on the retina

    by Sara Aissati, Clara Benedi-Garcia, Maria Vinas, Alberto de Castro, Susana Marcos

    Convolved images are often used to simulate the effect of ocular aberrations on image quality, where the retinal image is simulated by convolving the stimulus with the point spread function derived from the subject's aberrations. However, some studies have shown that convolved images are perceived far more degraded than the same image blurred with optical defocus. We hypothesized that the positive interactions between the monochromatic and chromatic aberrations in the eye are lost in the convolution process. To test this hypothesis, we evaluated optical and visual quality with natural optics and with convolved images (on-bench, computer simulations, and visual acuity [VA] in subjects) using a polychromatic adaptive optics system with monochromatic (555 nm) and polychromatic light (WL) illumination. The subject's aberrations were measured using a Hartmann Shack system and were used to convolve the visual stimuli, using Fourier optics. The convolved images were seen through corrected optics. VA with convolved stimuli was lower than VA through natural aberrations, particularly in WL (by 26% in WL). Our results suggest that the systematic decrease in visual performance with visual acuity and retinal image quality by simulation with convolved stimuli appears to be primarily associated with a lack of favorable interaction between chromatic and monochromatic aberrations in the eye.


  • Optical and visual quality of real intraocular lenses physically projected on the patient’s eye

    by Clara Benedi-Garcia, Maria Vinas, Carmen María Lago, Sara Aissati, Alberto de Castro, Carlos Dorronsoro, Susana Marcos

    Visual simulators aim at evaluating vision with ophthalmic corrections prior to prescription or implantation of intraocular lenses (IOLs) in the patient’s eye. In the present study, we present the design, implementation, and validation of a new IOL-in-cuvette channel in an Adaptive Optics visual simulator, which provides an alternative channel for pre-operative simulation of vision with IOLs. The IOL is projected on the pupil’s plane of the subject by using a Rassow system. A second lens, the Rassow lens, compensates for an IOL of 20 D while other powers can be corrected with a Badal system within a 5 D range. The new channel was evaluated by through-focus (TF) optical quality in an artificial eye on bench, and by TF visual acuity in patients, with various IOL designs (monofocal, diffractive trifocal, and refractive extended depth of focus).


  • Vision with spatial light modulator simulating multifocal contact lenses in an adaptive optics system

    by Shrilekha Vedhakrishnan, Maria Vinas, Sara Aissati, Susana Marcos

    Visual simulators are useful tools to provide patients experience of multifocal vision prior to treatment. In this study, commercially available center-near aspheric multifocal contact lenses (MCLs) of low, medium, and high additions were mapped on a spatial light modulator (SLM) and validated on a bench. Through focus visual acuity (TFVA) was measured in subjects through the SLM and real MCLs on the eye. A correlation metric revealed statistically significant shape similarity between TFVA curves with real and simulated MCLs. A Bland-Altman analysis showed differences within confidence intervals of ±0.01 logMAR for LowAdd/MediumAdd and ±0.06 logMAR for HighAdd. Visual performance with simulated MCLs outperformed real MCLs by ∼20%. In conclusion, SLM captures the profile of center-near MCLs and reproduces vision with real MCLs, revealing that the MCL profile and its interactions with the eye’s optics (and not fitting aspects) account for the majority of the contributions to visual performance with MCLs.