ZLZhenkun Li

Zhenkun Li

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Zhenkun Li has a total of 32 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Joint Optimization for Micro-siting and Collector System of Floating Wind and Wave Energy Considering Stochastic Displacements under Combined Wind-Wave-Current Loads

    by Zhiquan Zhang, Haolong Wu, Yang Fu, Zhenkun Li

    Co-locating floating wind turbines (FWTs) with wave energy converters (WECs) offers a promising pathway to reduce the levelized cost of electricity (LCOE) for deep-sea renewable energy. However, stochastic platform displacements under coupled wind–wave–current loads aggravate wake interactions, degrade WEC shielding benefits, and increase cable fatigue risks—challenges not addressed by existing deterministic or empirical approaches. This paper proposes a bi-level distributionally robust optimization method for joint micro-siting and collector-system design of hybrid FWT–WEC plants. The upper level optimizes device layout by incorporating motion-aware wake–shielding coupling, while the lower level formulates a distributionally robust optimization (DRO) model for cable topology, sizing, and slack allocation using Wasserstein ambiguity sets constructed via kernel density estimation. Case studies demonstrate that the proposed method reduces wake losses by 53.70%, FWT heave amplitude by 42.3%, cable length by 4.81%, line losses by 12.76%, and reliability costs by 39.55%, achieving an overall LCOE reduction of 5.36% compared to conventional approaches.

  • A Resilience Enhancement Strategy for Electric-Hydrogen Coupled System Considering Unmanned Aerial Vehicle De-Icing Under Extreme Ice Storm

    by Shuxin Tian, Haoxing Zhao, Yang Fu, Kui Li, Zhenkun Li

    Extreme ice storms cause severe icing faults on power lines and energy supply shortages, which can seriously threaten the safe operation of distribution systems. To enhance system resilience, a comprehensive resilience enhancement strategy for electric–hydrogen coupled distribution systems considering unmanned aerial vehicle (UAV) de-icing and hydrogen energy storage systems (HESS) is proposed in this paper. First, a line icing thickness model under extreme ice storms is established considering UAV de-icing effects to derive the corresponding fault rate. Second, resilience evaluation indicators are developed to quantify the disaster resistance and recovery capabilities of the electric–hydrogen coupled distribution system. Finally, a multi-dimensional disaster mitigation optimization model is formulated to strengthen the defense capability and resilience of the electric–hydrogen coupled system. Simulations are conducted on an improved IEEE 33-bus distribution system integrating UAVs and hydrogen energy storage systems, verifying that the proposed strategy significantly enhances restoration capability under extreme icing disasters while reducing economic costs.

  • Study on the influence of design parameters on the dynamic instability of bearingless rotor helicopter

    by Yan Zhu, YuHui Lu, Zhenkun Li, Qiyou Cheng, Fengnan Sun, Feng Qian, Zhizhuang Feng

    In order to improve the stability of ground resonance and air resonance of the bearingless rotor helicopter, especially the unstable phenomenon of air resonance may occur in the condition of large overload high-speed flight and maneuvering flight, how to broaden the flight envelope of air stability, the key is to study and master the design parameters or factors that significantly affect the dynamic instability. Based on the stability analysis of the bearingless rotor model test-bed and the compatibility design analysis of ground and air resonance of bearingless rotor prototype, some main factors affecting the ground and air resonance were summarized and found. The influence of these design parameters is mainly studied, such as natural frequency, aerodynamic damping, artificial damping, lift force, pitch control line stiffness and flight speed. The influence of these design parameters on the stability was analyzed to provide technical support for avoiding or eliminating the ground and air resonance instability. It provides important design measures for improving or eliminating the ground and air resonance of bearingless rotor.

  • Open Access

    An improved fault control strategy for virtual synchronous generator with the coordination of STATCOM during unbalanced fault

    by Yu Wang, Liang Ji, Yifan Ding, Xiao Chang, Qiteng Hong, Botong Li, Zhenkun Li, Xingwu Yang

    The virtual synchronous generator (VSG) is a good solution for stabilizing the power system with high penetration of renewable energy. However, in case of serious unbalanced voltage disturbance/fault, the conventional VSG may lose voltage, inertia, and damping support characteristics to the grid and even can cause disconnection of renewable energy. This paper proposes an improved fault control strategy for VSG with the coordination of STATCOM. The proposed method can provide sufficient voltage support while keeping continuous system inertia and damping support under severe unbalanced fault. In the paper, an improved VSG and STATCOM control topology based on positive and negative sequence current control are first proposed so as to keep the damping and inertia support to grid during the grid fault. Secondly, the voltage support control method for the VSG with improved topology during unbalanced fault is introduced, which can achieve multiple control objectives, in terms of voltage support, current limitation, and active power output simultaneously. Then a coordination control scheme of improved VSG and STATCOM is developed so as to optimize the maximum control objectives in all possible scenarios, especially in the case of severe unbalanced fault. Finally, the effectiveness of the method is verified by using the MATLAB/SIMULINK simulation platform.


  • Open Access

    Energy supply reliability assessment of the integrated energy system considering complementary and optimal operation during failure

    by Zhenkun Li, Zhifeng Wang, Yang Fu, Nan Zhao

    Integrated energy system (IES) is an effective solution for energy and environment problems. In view of the difficulty of traditional reliability assessment methods to reasonably and effectively assess the reliability of the IES, an energy supply reliability assessment method based on sequential Monte Carlo simulation is proposed in this study. The optimal operation of the system is realised by mobilising the multi‐energy complementary characteristics during device failure. The reliability of the system under three different operation objectives is compared and analysed. Three new reliability indices are proposed, which take into account the supply of multiple energy loads and the differences among different energy. Finally, through the analysis of energy supply reliability under different objectives, the reasonability of the proposed indices and the flexible scheduling of energy flow under different objectives are verified; therefore, the IES can realise adaptive and targeted operation strategy during device failure. Also, the influence of different device faults on the system's energy supply reliability is ranked, which is of great significance to find the weak parts of the system and provide a reference for the system to improve energy supply reliability.


  • A Multi-Objective Control Strategy for Three Phase Grid-Connected Inverter During Unbalanced Voltage Sag

    by Liang Ji, Jiabin Shi, Qiteng Hong, Yang Fu, Xiao Chang, Zhe Cao, Yang Mi, Zhenkun Li, Campbell Booth

    This paper presents a new multi-objective control strategy for inverter-interfaced distributed generation (IIDG) to ensure its safe and continuous operation under unbalanced voltage sags. The proposed control strategy can effectively improve the low voltage ride through (LVRT) capability, reduce active power oscillations, and limit overcurrent simultaneously, which are marked as the most important control objectives of IIDG during unbalanced voltage sags. The advanced voltage support scheme, which utilizes positive sequence component, is firstly proposed to maximize the LVRT capability of IIDG during unbalanced voltage sags. Then, to ensure the safety of IIDG, the active power oscillation suppression and current limitation algorithm are designed individually. Based on the control algorithms of such objectives, the multi-objective control method, including scenario classification and reference current determination, is then presented to achieve such three objectives under various system conditions simultaneously. Finally, case studies and evaluations based on MATLAB/Simulink are carried out to illustrate the effectiveness of the proposed method.


  • Energy Management for Hybrid AC/DC Distribution System With Microgrid Clusters Using Non-Cooperative Game Theory and Robust Optimization

    by Yang Fu, Zhiquan Zhang, Zhenkun Li, Yang Mi

    This paper presents a novel coordinated energy management approach for hybrid AC/DC distribution system with microgrid clusters considering multiple market players, which is modeled as a bi-level optimization problem by using non-cooperative game theory and robust optimization. The hybrid AC/DC distribution network and each microgrid are regarded as different entities, which are in the upper/lower level of the model, respectively. Considering the uncertainty of renewable energy, two-stage robust optimization is added in the bi-level optimization problem to suppress the influence of uncertainty on power interaction and achieve the minimum operation costs of each entity under uncertainty. Furthermore, In the upper level model, hybrid AC/DC distribution network can control power flow in real time, promote power interaction between entities, and reduce operation cost under uncertainty by using effective control of converter station and diesel generator. And each microgrid has dealt with the impact of uncertainty on the power interaction by reasonably managing the charge/discharge of energy storage, which realizes its own minimum operation cost. The proposed model can be transformed into mathematical programming with complementarity constraints (MPCC) by using Karush-Kuhn-Tucker conditions. Finally, numerical cases on an improved IEEE 33-bus hybrid AC/DC distribution system show the effectiveness of the proposed method.