Nevzat Giineri Gencer
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Nevzat Giineri Gencer has a total of 57 co-authors. Here are the top co-authors by number of shared publications:
- Can Baris Top
Aselsan Research Center, Ankara, Turkey
8 shared publications Y.Z. Ider
Dept. of Electr. & Electron. Eng., Middle East Tech. Univ., Ankara, Turkey
6 shared publications- Azadeh Kamali Tafreshi
Member of Young Researcher Club of Biomedical Eng. Dept., Science & Research Branch, Islamic Azad University, Tehran, Iran
4 shared publications Reyhan Zengin
Electrical and Electronics Engineering, Middle East Technical University, Orta Dogu Teknik Universitesi Elektrik-Elektronik Muhendisligi B, Ankara, 06800, TURKEY
3 shared publicationsBalkar Erdogan
Elektrik ve Elektronik Mühendisli¿i Bölümü, Orta Do¿u Teknik Üniversitesi, Turkey
2 shared publicationsBerna Akinci
Elektrik ve Elektronik Mühendisli¿i Bölümü, Orta Do¿u Teknik Üniversitesi, Turkey
2 shared publications
Latest Publications
- Open Access
- 9 July 2025
- Published by Wiley in International Journal for Numerical Methods in Biomedical Engineering
- Vol. 41 (7) , e70063
Enhancing Imaging Performance and Resolution in Magneto‐Acoustic Electrical Tomography With Magnetic Field Measurements ( MAET ‐ MI ) Using Figure‐of‐Eight and High‐Quality Factor Circular Coils
Magneto‐acousto‐electrical tomography with magnetic field measurement technique (MAET‐MI) is a hybrid imaging method that brings high spatial resolution of ultrasound imaging in electrical impedance tomography. This study investigates the impact of the quality factor of circular and figure‐of‐eight coils on the imaging performance of MAET‐MI. Induced MAET signals on the circular coil are accurately obtained by modeling a circuit representation of an air‐cored circular coil and deriving its transfer function through impedance measurements. The study demonstrates a significant improvement in signal‐to‐noise ratio (SNR) using high‐quality factor coils compared to unity quality factor coils. Additionally, a 16‐element linear phased array (LPA) ultrasound transducer, an air core circular coil, and a figure‐of‐eight coil are numerically modeled to obtain sector scan images of two‐dimensional conductivity distributions. Point spread function (PSF) is characterized, and the lateral resolution of sector scan conductivity images is enhanced through two‐dimensional deconvolution with PSF. The combined use of circular and figure‐of‐eight coils provides comprehensive imaging coverage. Notably, this research presents a practical method for estimating both circular and figure‐of‐eight coils' transfer functions, achieving 12.9 dB SNR improvement with high‐quality factor coils. A simplified breast model is rotated 16 steps, and sector scan conductive boundary images are reconstructed for both coils. A two‐dimensional image of a breast model is obtained by combining images from two different coils. These findings offer significant advancements in MAET‐MI imaging, particularly in low SNR environments.
- 9 July 2025
- Published by Wiley in International Journal for Numerical Methods in Biomedical Engineering
- Vol. 41 (7) , e70063
Open AccessEnhancing Imaging Performance and Resolution in Magneto‐Acoustic Electrical Tomography With Magnetic Field Measurements ( MAET ‐ MI ) Using Figure‐of‐Eight and High‐Quality Factor Circular Coils
Magneto‐acousto‐electrical tomography with magnetic field measurement technique (MAET‐MI) is a hybrid imaging method that brings high spatial resolution of ultrasound imaging in electrical impedance tomography. This study investigates the impact of the quality factor of circular and figure‐of‐eight coils on the imaging performance of MAET‐MI. Induced MAET signals on the circular coil are accurately obtained by modeling a circuit representation of an air‐cored circular coil and deriving its transfer function through impedance measurements. The study demonstrates a significant improvement in signal‐to‐noise ratio (SNR) using high‐quality factor coils compared to unity quality factor coils. Additionally, a 16‐element linear phased array (LPA) ultrasound transducer, an air core circular coil, and a figure‐of‐eight coil are numerically modeled to obtain sector scan images of two‐dimensional conductivity distributions. Point spread function (PSF) is characterized, and the lateral resolution of sector scan conductivity images is enhanced through two‐dimensional deconvolution with PSF. The combined use of circular and figure‐of‐eight coils provides comprehensive imaging coverage. Notably, this research presents a practical method for estimating both circular and figure‐of‐eight coils' transfer functions, achieving 12.9 dB SNR improvement with high‐quality factor coils. A simplified breast model is rotated 16 steps, and sector scan conductive boundary images are reconstructed for both coils. A two‐dimensional image of a breast model is obtained by combining images from two different coils. These findings offer significant advancements in MAET‐MI imaging, particularly in low SNR environments.
- Open Access
- 15 April 2025
- Published by Wiley in Annals of the New York Academy of Sciences
- Vol. 1547 (1) , 192-203
Development of breast tissue–mimicking electrical and acoustic phantoms for magneto‐acoustic electrical tomography
Magneto‐acousto electrical tomography (MAET) is a novel medical imaging technique that relies on the difference in electrical properties between healthy and tumor tissues. To facilitate MAET experiments, this study proposes a comprehensive procedure for developing, characterizing, and preserving realistic breast tissue–mimicking phantoms. We developed nontoxic and inexpensive phantoms using sodium alginate, graphite powder, agar, propanediol, aluminum powder, glycine, and deionized water. The dielectric (conductivity and permittivity) and acoustic (speed of sound) properties of phantoms (breast fat, breast gland, and tumor) within the 1–8 MHz frequency range were measured to ensure their suitability for MAET experiments. In conclusion, this study presents a detailed methodology for the preparation, characterization, and preservation of realistic breast tissue–mimicking phantoms tailored for MAET experiments.
- 15 April 2025
- Published by Wiley in Annals of the New York Academy of Sciences
- Vol. 1547 (1) , 192-203
Open AccessDevelopment of breast tissue–mimicking electrical and acoustic phantoms for magneto‐acoustic electrical tomography
Magneto‐acousto electrical tomography (MAET) is a novel medical imaging technique that relies on the difference in electrical properties between healthy and tumor tissues. To facilitate MAET experiments, this study proposes a comprehensive procedure for developing, characterizing, and preserving realistic breast tissue–mimicking phantoms. We developed nontoxic and inexpensive phantoms using sodium alginate, graphite powder, agar, propanediol, aluminum powder, glycine, and deionized water. The dielectric (conductivity and permittivity) and acoustic (speed of sound) properties of phantoms (breast fat, breast gland, and tumor) within the 1–8 MHz frequency range were measured to ensure their suitability for MAET experiments. In conclusion, this study presents a detailed methodology for the preparation, characterization, and preservation of realistic breast tissue–mimicking phantoms tailored for MAET experiments.
- 6 February 2024
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 52 (4) , 1078-1090
Induced Current Electro-Thermal Imaging for Breast Tumor Detection: A Numerical and Experimental Study
This study proposes using magnetically induced currents in medical infrared imaging to increase the temperature contrast due to the electrical conductivity differences between tumors and healthy tissues. There are two objectives: (1) to investigate the feasibility of this active method for surface and deep tumors using numerical simulations, and (2) to demonstrate the use of this method through different experiments conducted with phantoms that mimic breast tissues. Tumorous breasts were numerically modeled and simulated in active and passive modes. At 750 kHz, the applied current was limited for breast tissue-tumor conductivities (0.3 S/m and 0.75 S/m) according to the local specific absorption rate limit of 10 W/kg. Gelatin-based and mashed potato phantoms were produced to mimic tumorous breast tissues. In the simulation studies, the induced current changed the temperature contrast on the imaging surface, and the tumor detection sensitivity increased by 4 mm. An 11-turn 70-mm-long solenoid coil was constructed, 20 A current was applied for deep tumors, and a difference of up to 0.4 \(^\circ\)C was observed in the tumor location compared with the temperature in the absence of the tumor. Similarly, a 23-turn multi-layer coil was constructed, and a temperature difference of 0.4 \(^\circ\)C was observed. The temperature contrast on the body surface changed, and the tumor detection depth increased with the induced currents in breast IR imaging. The proposed active thermal imaging method was validated using numerical simulations and in vitro experiments.- 6 February 2024
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 52 (4) , 1078-1090
Induced Current Electro-Thermal Imaging for Breast Tumor Detection: A Numerical and Experimental Study
This study proposes using magnetically induced currents in medical infrared imaging to increase the temperature contrast due to the electrical conductivity differences between tumors and healthy tissues. There are two objectives: (1) to investigate the feasibility of this active method for surface and deep tumors using numerical simulations, and (2) to demonstrate the use of this method through different experiments conducted with phantoms that mimic breast tissues. Tumorous breasts were numerically modeled and simulated in active and passive modes. At 750 kHz, the applied current was limited for breast tissue-tumor conductivities (0.3 S/m and 0.75 S/m) according to the local specific absorption rate limit of 10 W/kg. Gelatin-based and mashed potato phantoms were produced to mimic tumorous breast tissues. In the simulation studies, the induced current changed the temperature contrast on the imaging surface, and the tumor detection sensitivity increased by 4 mm. An 11-turn 70-mm-long solenoid coil was constructed, 20 A current was applied for deep tumors, and a difference of up to 0.4 \(^\circ\)C was observed in the tumor location compared with the temperature in the absence of the tumor. Similarly, a 23-turn multi-layer coil was constructed, and a temperature difference of 0.4 \(^\circ\)C was observed. The temperature contrast on the body surface changed, and the tumor detection depth increased with the induced currents in breast IR imaging. The proposed active thermal imaging method was validated using numerical simulations and in vitro experiments.- 23 April 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Electromagnetics, RF and Microwaves in Medicine and Biology
- Vol. 5 (4) , 362-370
The Effect of Contrasts in Electrical and Mechanical Properties Between Breast Tissues on Harmonic Motion Microwave Doppler Imaging Signal
Harmonic Motion Microwave Doppler Imaging (HMMDI) method employs concurrent tissue excitation with focused ultrasound radiation force and microwaves to obtain information on malignancy, based on the dielectric and mechanical properties of the tissues. In this study, we analyze the effect of dielectric and elastic contrasts between a small (tumor) inclusion (3 mm) and the surrounding normal tissue on the HMMDI signal as functions of inclusion position and vibration frequency (from 10 Hz to 95 Hz) using simulations. To solve the forward problem of HMMDI, we developed a Discrete Dipole Approximation (DDA) based simulation method, and analyzed the received HMMDI signal for low to medium dielectric contrast (1:1.17, 1:2.6, 1:3.5) and elastic contrast (1:1.5, 1:2.5, 1:5) levels. DDA solver decreased the simulation time by a factor of 146 compared to the Finite Difference Time Domain method and facilitated the extensive number of simulations required for the analysis. The results of this study provide useful information for the development of the HMMDI method as a tool for breast cancer detection in dense tissues.
- 23 April 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Electromagnetics, RF and Microwaves in Medicine and Biology
- Vol. 5 (4) , 362-370
The Effect of Contrasts in Electrical and Mechanical Properties Between Breast Tissues on Harmonic Motion Microwave Doppler Imaging Signal
Harmonic Motion Microwave Doppler Imaging (HMMDI) method employs concurrent tissue excitation with focused ultrasound radiation force and microwaves to obtain information on malignancy, based on the dielectric and mechanical properties of the tissues. In this study, we analyze the effect of dielectric and elastic contrasts between a small (tumor) inclusion (3 mm) and the surrounding normal tissue on the HMMDI signal as functions of inclusion position and vibration frequency (from 10 Hz to 95 Hz) using simulations. To solve the forward problem of HMMDI, we developed a Discrete Dipole Approximation (DDA) based simulation method, and analyzed the received HMMDI signal for low to medium dielectric contrast (1:1.17, 1:2.6, 1:3.5) and elastic contrast (1:1.5, 1:2.5, 1:5) levels. DDA solver decreased the simulation time by a factor of 146 compared to the Finite Difference Time Domain method and facilitated the extensive number of simulations required for the analysis. The results of this study provide useful information for the development of the HMMDI method as a tool for breast cancer detection in dense tissues.
- 29 May 2019
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 64 (11) , 115016
Data acquisition system for MAET with magnetic field measurements
Magneto-acousto-electrical tomography (MAET) is an imaging modality to image the electrical conductivity of biological tissues. It is based on electrical current induction by using ultrasound under a static magnetic field. The aim of this study is to develop a data acquisition system for MAET based on magnetic field measurements. The static magnetic field is generated by six permanent neodymium magnets. A 16-element linear phased array (LPA) transducer is utilized to generate acoustic pressure waves inside the phantom. To measure the magnetic field intensity generated by the induced currents, contactless receiver sensors are developed using two similar disk multiple layer coils, which are Helmholtz coil sensor. Physical properties and electrical characteristics of the sensors are assessed. A two-stage cascaded amplifier is designed and utilized in the receiving system. The gain of the cascaded amplifier at 1 MHz is adjusted to be 96 dB. Experimental studies are conducted with two different phantoms, having 3 S m −1 and 58 S m −1 electrical conductivity, respectively. A-scan and B-scan images of phantoms are obtained with the LPA transducer. Comparison of the ultrasound (A-scan) and MAET signals reveals that 3 S m −1 conductive inhomogeneity can be detected with this data acquisition system. Furthermore, the front and rear interfaces of an inhomogeneity ( ) of 58 S m −1 conductivity are detectable.
- 29 May 2019
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 64 (11) , 115016
Data acquisition system for MAET with magnetic field measurements
Magneto-acousto-electrical tomography (MAET) is an imaging modality to image the electrical conductivity of biological tissues. It is based on electrical current induction by using ultrasound under a static magnetic field. The aim of this study is to develop a data acquisition system for MAET based on magnetic field measurements. The static magnetic field is generated by six permanent neodymium magnets. A 16-element linear phased array (LPA) transducer is utilized to generate acoustic pressure waves inside the phantom. To measure the magnetic field intensity generated by the induced currents, contactless receiver sensors are developed using two similar disk multiple layer coils, which are Helmholtz coil sensor. Physical properties and electrical characteristics of the sensors are assessed. A two-stage cascaded amplifier is designed and utilized in the receiving system. The gain of the cascaded amplifier at 1 MHz is adjusted to be 96 dB. Experimental studies are conducted with two different phantoms, having 3 S m −1 and 58 S m −1 electrical conductivity, respectively. A-scan and B-scan images of phantoms are obtained with the LPA transducer. Comparison of the ultrasound (A-scan) and MAET signals reveals that 3 S m −1 conductive inhomogeneity can be detected with this data acquisition system. Furthermore, the front and rear interfaces of an inhomogeneity ( ) of 58 S m −1 conductivity are detectable.
- 3 October 2017
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 62 (20) , 8025-8040
Theoretical limits to sensitivity and resolution in magneto-acousto-electrical tomography
In this study, the performance of magneto-acousto-electrical tomography (MAET) is investigated quantitatively by considering interrelations between its sensitivity, resolution and conductivity contrast. An analytical solution for the forward problem of MAET is derived for two-dimensional (2D) concentric bodies by the separation of variables method. The electric potential and the acoustic pressure are separated into their angular and radial components. The series coefficients for these solutions are obtained from their respective boundary conditions. The electric potential on the boundary is related to the acoustic boundary acceleration analytically. From this relation, a sensitivity expression is derived relating fractional change in conductivity contrast to fractional change in the measured electric potential. This expression is a function of the resolution and conductivity contrast of the imaging system. It also depends on the acoustic wave number and the dimensions of the body. The pair-wise relations between these parameters are presented. The sensitivity behavior of MAET is compared with applied current electrical impedance tomography and the improvements for small inhomogeneities are presented. For eccentric bodies, a modified expression for the sensitivity is obtained by conformal mapping. For arbitrary periodic boundary excitations, the sensitivity expressions for harmonic cases are combined to obtain a unified sensitivity expression.
- 3 October 2017
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 62 (20) , 8025-8040
Theoretical limits to sensitivity and resolution in magneto-acousto-electrical tomography
In this study, the performance of magneto-acousto-electrical tomography (MAET) is investigated quantitatively by considering interrelations between its sensitivity, resolution and conductivity contrast. An analytical solution for the forward problem of MAET is derived for two-dimensional (2D) concentric bodies by the separation of variables method. The electric potential and the acoustic pressure are separated into their angular and radial components. The series coefficients for these solutions are obtained from their respective boundary conditions. The electric potential on the boundary is related to the acoustic boundary acceleration analytically. From this relation, a sensitivity expression is derived relating fractional change in conductivity contrast to fractional change in the measured electric potential. This expression is a function of the resolution and conductivity contrast of the imaging system. It also depends on the acoustic wave number and the dimensions of the body. The pair-wise relations between these parameters are presented. The sensitivity behavior of MAET is compared with applied current electrical impedance tomography and the improvements for small inhomogeneities are presented. For eccentric bodies, a modified expression for the sensitivity is obtained by conformal mapping. For arbitrary periodic boundary excitations, the sensitivity expressions for harmonic cases are combined to obtain a unified sensitivity expression.
- 22 May 2017
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 62 (12) , 4852-4869
Two-dimensional multi-frequency imaging of a tumor inclusion in a homogeneous breast phantom using the harmonic motion Doppler imaging method
Harmonic motion microwave Doppler imaging (HMMDI) is a novel imaging modality for imaging the coupled electrical and mechanical properties of body tissues. In this paper, we used two experimental systems with different receiver configurations to obtain HMMDI images from tissue-mimicking phantoms at multiple vibration frequencies between 15 Hz and 35 Hz. In the first system, we used a spectrum analyzer to obtain the Doppler data in the frequency domain, while in the second one, we used a homodyne receiver that was designed to acquire time-domain data. The developed phantoms mimicked the elastic and dielectric properties of breast fat tissue, and included a 14 m m × 9 mm cylindrical inclusion representing the tumor. A focused ultrasound probe was mechanically scanned in two lateral dimensions to obtain two-dimensional HMMDI images of the phantoms. The inclusions were resolved inside the fat phantom using both experimental setups. The image resolution increased with increasing vibration frequency. The designed receiver showed higher sensitivity than the spectrum analyzer measurements. The results also showed that time-domain data acquisition should be used to fully exploit the potential of the HMMDI method.
- 22 May 2017
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 62 (12) , 4852-4869
Two-dimensional multi-frequency imaging of a tumor inclusion in a homogeneous breast phantom using the harmonic motion Doppler imaging method
Harmonic motion microwave Doppler imaging (HMMDI) is a novel imaging modality for imaging the coupled electrical and mechanical properties of body tissues. In this paper, we used two experimental systems with different receiver configurations to obtain HMMDI images from tissue-mimicking phantoms at multiple vibration frequencies between 15 Hz and 35 Hz. In the first system, we used a spectrum analyzer to obtain the Doppler data in the frequency domain, while in the second one, we used a homodyne receiver that was designed to acquire time-domain data. The developed phantoms mimicked the elastic and dielectric properties of breast fat tissue, and included a 14 m m × 9 mm cylindrical inclusion representing the tumor. A focused ultrasound probe was mechanically scanned in two lateral dimensions to obtain two-dimensional HMMDI images of the phantoms. The inclusions were resolved inside the fat phantom using both experimental setups. The image resolution increased with increasing vibration frequency. The designed receiver showed higher sensitivity than the spectrum analyzer measurements. The results also showed that time-domain data acquisition should be used to fully exploit the potential of the HMMDI method.
- 1 January 2017
- Published by ACTA Press
A Numerical Analysis of Magneto-Acousto Electrical Tomography with a Simplified Breast Model
- 1 January 2017
- Published by ACTA Press
A Numerical Analysis of Magneto-Acousto Electrical Tomography with a Simplified Breast Model
- 23 September 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Microwave Theory and Techniques
- Vol. 64 (11) , 3974-3986
Microwave Sensing of Acoustically Induced Local Harmonic Motion: Experimental and Simulation Studies on Breast Tumor Detection
Sensing acoustically induced local harmonic motion using a microwave transceiver system may provide useful information for detecting nonpalpable tumors in dense breast tissue. For this purpose, we propose the harmonic motion microwave Doppler imaging method, in which the first harmonic of the phase modulated signal due to local harmonic motion is sensed. This signal is related to the dielectric, elastic, and acoustic properties of the vibrating region. The purpose of this paper is twofold: 1) to demonstrate the concept of this method with experiments using phantom materials mimicking the elastic and electrical properties of the breast tissue and 2) to investigate the effect of fibroglandular region size and vibration frequency on the received signal, using numerical simulations. A breast phantom with a tumor phantom inclusion (5-mm diameter and 7-mm height) inside fibroglandular region is constructed for the experimental study. The response due to a focused ultrasound probe is linearly scanned at 30-mm depth from the phantom surface, and the Doppler signal level is tracked using a spectrum analyzer. It is shown that the tumor phantom is resolvable inside the surrounding fibroglandular region with about a 3-5-dB decrease in the signal level. The simulations, using the finite-difference time-domain method, show that the received signal level depends on the relative size of the fibroglandular region with respect to the vibrating region size. Further experimental and numerical studies are needed to investigate the feasibility of this method and to optimize the imaging system design.
- 23 September 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Microwave Theory and Techniques
- Vol. 64 (11) , 3974-3986
Microwave Sensing of Acoustically Induced Local Harmonic Motion: Experimental and Simulation Studies on Breast Tumor Detection
Sensing acoustically induced local harmonic motion using a microwave transceiver system may provide useful information for detecting nonpalpable tumors in dense breast tissue. For this purpose, we propose the harmonic motion microwave Doppler imaging method, in which the first harmonic of the phase modulated signal due to local harmonic motion is sensed. This signal is related to the dielectric, elastic, and acoustic properties of the vibrating region. The purpose of this paper is twofold: 1) to demonstrate the concept of this method with experiments using phantom materials mimicking the elastic and electrical properties of the breast tissue and 2) to investigate the effect of fibroglandular region size and vibration frequency on the received signal, using numerical simulations. A breast phantom with a tumor phantom inclusion (5-mm diameter and 7-mm height) inside fibroglandular region is constructed for the experimental study. The response due to a focused ultrasound probe is linearly scanned at 30-mm depth from the phantom surface, and the Doppler signal level is tracked using a spectrum analyzer. It is shown that the tumor phantom is resolvable inside the surrounding fibroglandular region with about a 3-5-dB decrease in the signal level. The simulations, using the finite-difference time-domain method, show that the received signal level depends on the relative size of the fibroglandular region with respect to the vibrating region size. Further experimental and numerical studies are needed to investigate the feasibility of this method and to optimize the imaging system design.
- 20 July 2016
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 61 (16) , 5887-5905
Lorentz force electrical impedance tomography using magnetic field measurements
In this study, magnetic field measurement technique is investigated to image the electrical conductivity properties of biological tissues using Lorentz forces. This technique is based on electrical current induction using ultrasound together with an applied static magnetic field. The magnetic field intensity generated due to induced currents is measured using two coil configurations, namely, a rectangular loop coil and a novel xy coil pair. A time-varying voltage is picked-up and recorded while the acoustic wave propagates along its path. The forward problem of this imaging modality is defined as calculation of the pick-up voltages due to a given acoustic excitation and known body properties. Firstly, the feasibility of the proposed technique is investigated analytically. The basic field equations governing the behaviour of time-varying electromagnetic fields are presented. Secondly, the general formulation of the partial differential equations for the scalar and magnetic vector potentials are derived. To investigate the feasibility of this technique, numerical studies are conducted using a finite element method based software. To sense the pick-up voltages a novel coil configuration ( xy coil pairs) is proposed. Two-dimensional numerical geometry with a 16-element linear phased array (LPA) ultrasonic transducer (1 MHz) and a conductive body (breast fat) with five tumorous tissues is modeled. The static magnetic field is assumed to be 4 Tesla. To understand the performance of the imaging system, the sensitivity matrix is analyzed. The sensitivity matrix is obtained for two different locations of LPA transducer with eleven steering angles from − 25 ∘ to 25 ∘ at intervals of 5 ∘ . The characteristics of the imaging system are shown with the singular value decomposition (SVD) of the sensitivity matrix. The images are reconstructed with the truncated SVD algorithm. The signal-to-noise ratio in measurements is assumed 80 dB. Simulation studies based on the sensitivity matrix analysis reveal that perturbations with 5 m m × 5 mm size can be detected up to a 3.5 cm depth.
- 20 July 2016
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 61 (16) , 5887-5905
Lorentz force electrical impedance tomography using magnetic field measurements
In this study, magnetic field measurement technique is investigated to image the electrical conductivity properties of biological tissues using Lorentz forces. This technique is based on electrical current induction using ultrasound together with an applied static magnetic field. The magnetic field intensity generated due to induced currents is measured using two coil configurations, namely, a rectangular loop coil and a novel xy coil pair. A time-varying voltage is picked-up and recorded while the acoustic wave propagates along its path. The forward problem of this imaging modality is defined as calculation of the pick-up voltages due to a given acoustic excitation and known body properties. Firstly, the feasibility of the proposed technique is investigated analytically. The basic field equations governing the behaviour of time-varying electromagnetic fields are presented. Secondly, the general formulation of the partial differential equations for the scalar and magnetic vector potentials are derived. To investigate the feasibility of this technique, numerical studies are conducted using a finite element method based software. To sense the pick-up voltages a novel coil configuration ( xy coil pairs) is proposed. Two-dimensional numerical geometry with a 16-element linear phased array (LPA) ultrasonic transducer (1 MHz) and a conductive body (breast fat) with five tumorous tissues is modeled. The static magnetic field is assumed to be 4 Tesla. To understand the performance of the imaging system, the sensitivity matrix is analyzed. The sensitivity matrix is obtained for two different locations of LPA transducer with eleven steering angles from − 25 ∘ to 25 ∘ at intervals of 5 ∘ . The characteristics of the imaging system are shown with the singular value decomposition (SVD) of the sensitivity matrix. The images are reconstructed with the truncated SVD algorithm. The signal-to-noise ratio in measurements is assumed 80 dB. Simulation studies based on the sensitivity matrix analysis reveal that perturbations with 5 m m × 5 mm size can be detected up to a 3.5 cm depth.