Patricia Cristina Grenzi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Patricia Cristina Grenzi has a total of 53 co-authors. Here are the top co-authors by number of shared publications:
- José Osmar Medina-Pestana
Universidade Federal de São Paulo
4 shared publications Maria Gerbase-DeLima
Instituto de Imunogenética – AFIP, Rua Loefgreen 1235, 04040-031 São Paulo, SP, Brazil
3 shared publications- Maria Gerbase-DeLima
Immunogenetics Division, Pediatrics Department, Escola Paulista de Medicina, Federal University of Sao Paulo (UNIFESP), Sao Paulo, Brazil
3 shared publications - Daniel Bachurski
Department I of Internal Medicine, Center for Integrated Oncology Aachen Bonn Cologne Duesseldorf, CECAD Center of Excellence on Cellular Stress Responses in Aging-Associated Diseases, Faculty of Medicine and University Hospital Cologne, University of Cologne, Cologne, Germany
2 shared publications Erika F. Campos
2 shared publications- Erika F. Campos
Instituto de Imunogenética-AFIP, Rua Loefgreen 1235, 04040-031 São Paulo, SP, Brazil; Universidade Federal de São Paulo, Rua Sena Madureira 1500, 04021-001 São Paulo, SP, Brazil
2 shared publications
Latest Publications
- Top Cited PapersOpen Access
- 1 April 2019
- Published by Wiley in Journal of Extracellular Vesicles
- Vol. 8 (1) , 1596016
Extracellular vesicle measurements with nanoparticle tracking analysis – An accuracy and repeatability comparison between NanoSight NS300 and ZetaView
The expanding field of extracellular vesicle (EV) research needs reproducible and accurate methods to characterize single EVs. Nanoparticle Tracking Analysis (NTA) is commonly used to determine EV concentration and diameter. As the EV field is lacking methods to easily confirm and validate NTA data, questioning the reliability of measurements remains highly important. In this regard, a comparison addressing measurement quality between different NTA devices such as Malvern's NanoSight NS300 or Particle Metrix' ZetaView has not yet been conducted. To evaluate the accuracy and repeatability of size and concentration determinations of both devices, we employed comparative methods including transmission electron microscopy (TEM) and single particle interferometric reflectance imaging sensing (SP‐IRIS) by ExoView. Multiple test measurements with nanospheres, liposomes and ultracentrifuged EVs from human serum and cell culture supernatant were performed. Additionally, serial dilutions and freeze‐thaw cycle‐dependent EV decrease were measured to determine the robustness of each system. Strikingly, NanoSight NS300 exhibited a 2.0–2.1‐fold overestimation of polystyrene and silica nanosphere concentration. By measuring serial dilutions of EV samples, we demonstrated higher accuracy in concentration determination by ZetaView (% BIAS range: 2.7–8.5) in comparison with NanoSight NS300 (% BIAS range: 32.9–36.8). The concentration measurements by ZetaView were also more precise (% CV range: 0.0–4.7) than measurements by NanoSight NS300 (% CV range: 5.4–10.7). On the contrary, quantitative TEM imaging indicated more accurate EV sizing by NanoSight NS300 (% DTEM range: 79.5–134.3) compared to ZetaView (% DTEM range: 111.8–205.7), while being equally repeatable (NanoSight NS300% CV range: 0.8–6.7; ZetaView: 1.4–7.8). However, both devices failed to report a peak EV diameter below 60 nm compared to TEM and SP‐IRIS. Taken together, NTA devices differ strongly in their hardware and software affecting measuring results. ZetaView provided a more accurate and repeatable depiction of EV concentration, whereas NanoSight NS300 supplied size measurements of higher resolution.
- 1 April 2019
- Published by Wiley in Journal of Extracellular Vesicles
- Vol. 8 (1) , 1596016
Top Cited PapersOpen AccessExtracellular vesicle measurements with nanoparticle tracking analysis – An accuracy and repeatability comparison between NanoSight NS300 and ZetaView
The expanding field of extracellular vesicle (EV) research needs reproducible and accurate methods to characterize single EVs. Nanoparticle Tracking Analysis (NTA) is commonly used to determine EV concentration and diameter. As the EV field is lacking methods to easily confirm and validate NTA data, questioning the reliability of measurements remains highly important. In this regard, a comparison addressing measurement quality between different NTA devices such as Malvern's NanoSight NS300 or Particle Metrix' ZetaView has not yet been conducted. To evaluate the accuracy and repeatability of size and concentration determinations of both devices, we employed comparative methods including transmission electron microscopy (TEM) and single particle interferometric reflectance imaging sensing (SP‐IRIS) by ExoView. Multiple test measurements with nanospheres, liposomes and ultracentrifuged EVs from human serum and cell culture supernatant were performed. Additionally, serial dilutions and freeze‐thaw cycle‐dependent EV decrease were measured to determine the robustness of each system. Strikingly, NanoSight NS300 exhibited a 2.0–2.1‐fold overestimation of polystyrene and silica nanosphere concentration. By measuring serial dilutions of EV samples, we demonstrated higher accuracy in concentration determination by ZetaView (% BIAS range: 2.7–8.5) in comparison with NanoSight NS300 (% BIAS range: 32.9–36.8). The concentration measurements by ZetaView were also more precise (% CV range: 0.0–4.7) than measurements by NanoSight NS300 (% CV range: 5.4–10.7). On the contrary, quantitative TEM imaging indicated more accurate EV sizing by NanoSight NS300 (% DTEM range: 79.5–134.3) compared to ZetaView (% DTEM range: 111.8–205.7), while being equally repeatable (NanoSight NS300% CV range: 0.8–6.7; ZetaView: 1.4–7.8). However, both devices failed to report a peak EV diameter below 60 nm compared to TEM and SP‐IRIS. Taken together, NTA devices differ strongly in their hardware and software affecting measuring results. ZetaView provided a more accurate and repeatable depiction of EV concentration, whereas NanoSight NS300 supplied size measurements of higher resolution.
- 12 April 2018
- Published by Elsevier in Human Immunology
- Vol. 79 (7) , 550-557
Influence of immunosuppressive drugs on the CD30 molecule in kidney transplanted patients
- 12 April 2018
- Published by Elsevier in Human Immunology
- Vol. 79 (7) , 550-557
Influence of immunosuppressive drugs on the CD30 molecule in kidney transplanted patients
- Open Access
- 20 April 2016
- Published by Impact Journals, LLC in Oncotarget
- Vol. 7 (21) , 30523-30535
CD30 on extracellular vesicles from malignant Hodgkin cells supports damaging of CD30 ligand-expressing bystander cells with Brentuximab-Vedotin,in vitro
CD30 on extracellular vesicles from malignant Hodgkin cells supports damaging of CD30 ligand-expressing bystander cells with Brentuximab-Vedotin, in vitro
- 20 April 2016
- Published by Impact Journals, LLC in Oncotarget
- Vol. 7 (21) , 30523-30535
Open AccessCD30 on extracellular vesicles from malignant Hodgkin cells supports damaging of CD30 ligand-expressing bystander cells with Brentuximab-Vedotin,in vitro
CD30 on extracellular vesicles from malignant Hodgkin cells supports damaging of CD30 ligand-expressing bystander cells with Brentuximab-Vedotin, in vitro
- 1 March 2015
- Published by Elsevier in Transplant Immunology
- Vol. 32 (2) , 61-65
Post-transplant soluble CD30 levels are associated with early subclinical rejection in kidney transplantation
- 1 March 2015
- Published by Elsevier in Transplant Immunology
- Vol. 32 (2) , 61-65
Post-transplant soluble CD30 levels are associated with early subclinical rejection in kidney transplantation
- 1 December 2013
- Published by Elsevier in Transplant Immunology
- Vol. 29 (1-4) , 34-38
Association of high post-transplant soluble CD30 serum levels with chronic allograft nephropathy
- 1 December 2013
- Published by Elsevier in Transplant Immunology
- Vol. 29 (1-4) , 34-38
Association of high post-transplant soluble CD30 serum levels with chronic allograft nephropathy
- 1 October 2013
- Published by Elsevier in Human Immunology
- Vol. 74 (10) , 1300-1303
Antibodies against denatured HLA class II molecules detected in luminex-single antigen assay
- 1 October 2013
- Published by Elsevier in Human Immunology
- Vol. 74 (10) , 1300-1303
Antibodies against denatured HLA class II molecules detected in luminex-single antigen assay
- 27 September 2012
- Published by Wolters Kluwer Health in Transplantation
- Vol. 94 (6) , 589-595
TLR4 mRNA Levels as Tools to Estimate Risk for Early Posttransplantation Kidney Graft Dysfunction
The participation of Toll-like receptor (TLR) 4, an innate immunity receptor, has been previously demonstrated in the pathogenesis of acute renal injury. We aimed to investigate whether messenger RNA (mRNA) levels of TLR4 and its adapter molecule, myeloid differentiation primary response gene (MYD) 88, are associated with delayed graft function (DGF) and could be used as biomarkers of its occurrence. TLR4 and MYD88 gene mRNA levels were evaluated with real-time polymerase chain reaction, in preimplantation biopsies (n=89) and first day posttransplantation samples of urine (n=67) and blood (n=80) from graft recipients and analyzed according to donor type (living or deceased) and DGF occurrence. Expression levels of both genes were higher in biopsies from deceased donors than from living donors (P14 days) (P=0.05, compared with cases without DGF); in blood, lower mRNA levels of TLR4 and MYD88 predicted pDGF occurrence with an accuracy of 86% and 87%, respectively. The expression levels of TLR4 and MYD88 were higher in kidneys from deceased donors than from living donors. Lower levels of expression of both genes in blood were associated with DGF occurrence. The prediction of prolonged DGF by low TLR4 and MYD88 expression levels in blood with a greater the 85% accuracy was the most important finding of this study.
- 27 September 2012
- Published by Wolters Kluwer Health in Transplantation
- Vol. 94 (6) , 589-595
TLR4 mRNA Levels as Tools to Estimate Risk for Early Posttransplantation Kidney Graft Dysfunction
The participation of Toll-like receptor (TLR) 4, an innate immunity receptor, has been previously demonstrated in the pathogenesis of acute renal injury. We aimed to investigate whether messenger RNA (mRNA) levels of TLR4 and its adapter molecule, myeloid differentiation primary response gene (MYD) 88, are associated with delayed graft function (DGF) and could be used as biomarkers of its occurrence. TLR4 and MYD88 gene mRNA levels were evaluated with real-time polymerase chain reaction, in preimplantation biopsies (n=89) and first day posttransplantation samples of urine (n=67) and blood (n=80) from graft recipients and analyzed according to donor type (living or deceased) and DGF occurrence. Expression levels of both genes were higher in biopsies from deceased donors than from living donors (P14 days) (P=0.05, compared with cases without DGF); in blood, lower mRNA levels of TLR4 and MYD88 predicted pDGF occurrence with an accuracy of 86% and 87%, respectively. The expression levels of TLR4 and MYD88 were higher in kidneys from deceased donors than from living donors. Lower levels of expression of both genes in blood were associated with DGF occurrence. The prediction of prolonged DGF by low TLR4 and MYD88 expression levels in blood with a greater the 85% accuracy was the most important finding of this study.
- 30 November 2009
- Published by Elsevier in Human Immunology
- Vol. 70, S52-52
81-P: Post-transplant anti-MICA antibodies and long-term kidney allograft survival
- 30 November 2009
- Published by Elsevier in Human Immunology
- Vol. 70, S52-52
81-P: Post-transplant anti-MICA antibodies and long-term kidney allograft survival