Marc Lavi Ruch
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Marc Lavi Ruch has a total of 44 co-authors. Here are the top co-authors by number of shared publications:
Sara A. Pozzi
University of Michigan, Department of Nuclear Engineering and Radiological Sciences, Ann Arbor, MI, 48109, USA
9 shared publications- Angela Di Fulvio
Department of Nuclear, Plasma, and Radiological Engineering, University of Illinois Urbana-Champaign, Urbana, IL, 61801, USA.
4 shared publications Shaun D. Clarke
University of Michigan, Department of Nuclear Engineering and Radiological Sciences, Ann Arbor, MI, 48109, USA
4 shared publicationsMarek Flaska
Department of Mechanical and Nuclear Engineering, Pennsylvania State University, University Park, PA 16802 USA
3 shared publicationsPeter Marleau
Radiation and Nuclear Detection Systems Division, Sandia National Laboratories, Livermore, CA, 94551, USA
2 shared publicationsS.A. Pozzi
2 shared publications
Latest Publications
- Open Access
- 9 July 2025
- Published by Office of Scientific and Technical Information (OSTI)
Incorporating the latest Neutron NDA analysis techniques into INCC6
- 9 July 2025
- Published by Office of Scientific and Technical Information (OSTI)
Open AccessIncorporating the latest Neutron NDA analysis techniques into INCC6
- Open Access
- 5 February 2020
- Published by Springer Nature in Scientific Reports
- Vol. 10 (1) , 1-11
Imaging Special Nuclear Material using a Handheld Dual Particle Imager
A compact radiation imaging system capable of detecting, localizing, and characterizing special nuclear material (e.g. highly-enriched uranium, plutonium…) would be useful for national security missions involving inspection, emergency response, or war-fighters. Previously-designed radiation imaging systems have been large and bulky with significant portions of volume occupied by photomultiplier tubes (PMTs). The prototype imaging system presented here uses silicon photomultipliers (SiPMs) in place of PMTs because SiPMs are much more compact and operate at low power and voltage. The SiPMs are coupled to the ends of eight stilbene organic scintillators, which have an overall volume of 5.74 × 5.74 × 7.11 cm3. The prototype dual-particle imager’s capabilities were evaluated by performing measurements with a 252Cf source, a sphere of 4.5 kg of alpha-phase weapons-grade plutonium known as the BeRP ball, a 6 kg sphere of neptunium, and a canister of 3.4 kg of plutonium oxide (7% 240Pu and 93% 239Pu). These measurements demonstrate neutron spectroscopic capabilities, a neutron image resolution for a Watt spectrum of 9.65 ± 0.94° in the azimuthal direction and 22.59 ± 5.81° in the altitude direction, imaging of gamma rays using organic scintillators, and imaging of multiple sources in the same field of view.
- 5 February 2020
- Published by Springer Nature in Scientific Reports
- Vol. 10 (1) , 1-11
Open AccessImaging Special Nuclear Material using a Handheld Dual Particle Imager
A compact radiation imaging system capable of detecting, localizing, and characterizing special nuclear material (e.g. highly-enriched uranium, plutonium…) would be useful for national security missions involving inspection, emergency response, or war-fighters. Previously-designed radiation imaging systems have been large and bulky with significant portions of volume occupied by photomultiplier tubes (PMTs). The prototype imaging system presented here uses silicon photomultipliers (SiPMs) in place of PMTs because SiPMs are much more compact and operate at low power and voltage. The SiPMs are coupled to the ends of eight stilbene organic scintillators, which have an overall volume of 5.74 × 5.74 × 7.11 cm3. The prototype dual-particle imager’s capabilities were evaluated by performing measurements with a 252Cf source, a sphere of 4.5 kg of alpha-phase weapons-grade plutonium known as the BeRP ball, a 6 kg sphere of neptunium, and a canister of 3.4 kg of plutonium oxide (7% 240Pu and 93% 239Pu). These measurements demonstrate neutron spectroscopic capabilities, a neutron image resolution for a Watt spectrum of 9.65 ± 0.94° in the azimuthal direction and 22.59 ± 5.81° in the altitude direction, imaging of gamma rays using organic scintillators, and imaging of multiple sources in the same field of view.
- 1 December 2019
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 946, 162179
Time behavior of the emission of 1274 keV gamma-rays from UF6
- 1 December 2019
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 946, 162179
Time behavior of the emission of 1274 keV gamma-rays from UF6
- 19 June 2019
- Published by Office of Scientific and Technical Information (OSTI)
Data Analytics for Nonproliferation Applications [Slides]
The U.S. Department of Energy's Office of Scientific and Technical Information
- 19 June 2019
- Published by Office of Scientific and Technical Information (OSTI)
Data Analytics for Nonproliferation Applications [Slides]
The U.S. Department of Energy's Office of Scientific and Technical Information
- 1 March 2018
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 884, 82-91
Light output response of EJ-309 liquid organic scintillator to 2.86–3.95 MeV carbon recoil ions due to neutron elastic and inelastic scatter
- 1 March 2018
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 884, 82-91
Light output response of EJ-309 liquid organic scintillator to 2.86–3.95 MeV carbon recoil ions due to neutron elastic and inelastic scatter
- 1 October 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-3
Performance of Stilbene Bars Coupled to Silicon Photomultipliers Using Different Reflectors
Two 6-mm by 6-mm by 50-mm bars of stilbene were each coupled to a silicon photomultiplier (SiPM) and evaluated for signal-to-noise ratio (SNR), time resolution, and pulse shape discrimination (PSD) capability using specular and diffuse reflectors. To evaluate the SNR at 478 keV, a Cs-137 source was placed between both bars and measured. The average SNR was 38% lower using a specular reflector as compared to using a diffuse reflector. The coincidence resolving time, measured with a Na-22 source, improved by 32% for standard output pulses and 40% for fast output pulses. PSD capability, measured with a Cf252 source, degraded with an increased gamma misclassification rate of about 972% for the light output range of 100-200-keVee. These results show that timing performance can be improved by using a specular reflector, but PSD capability is greatly diminished.
- 1 October 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-3
Performance of Stilbene Bars Coupled to Silicon Photomultipliers Using Different Reflectors
Two 6-mm by 6-mm by 50-mm bars of stilbene were each coupled to a silicon photomultiplier (SiPM) and evaluated for signal-to-noise ratio (SNR), time resolution, and pulse shape discrimination (PSD) capability using specular and diffuse reflectors. To evaluate the SNR at 478 keV, a Cs-137 source was placed between both bars and measured. The average SNR was 38% lower using a specular reflector as compared to using a diffuse reflector. The coincidence resolving time, measured with a Na-22 source, improved by 32% for standard output pulses and 40% for fast output pulses. PSD capability, measured with a Cf252 source, degraded with an increased gamma misclassification rate of about 972% for the light output range of 100-200-keVee. These results show that timing performance can be improved by using a specular reflector, but PSD capability is greatly diminished.
- 1 October 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-3
Readout Electronics of a Handheld Dual Particle Imager
We designed and realized the front-end readout circuit for a matrix of silicon photomultipliers (SiPM), to be used in handheld dual particle imagers. In this work, we optically coupled two 6-mm by 6-mm by 6-mm stilbene crystals to two separate pixels on the same SiPM matrix and studied the performance of the readout architecture in terms of energy resolution and timing. A Na-22 source was placed on the array between the two pixels and energy and time resolution were measured. We varied the resistance of the AC stage of the readout circuit for each pixel by placing resistors of various resistance values in parallel with the signal readout jack. The energy resolution of the system improved with increasing resistance values, as expected. The time resolution in the 200 to 400 keV energy band did not vary significantly as a function of resistance value.
- 1 October 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-3
Readout Electronics of a Handheld Dual Particle Imager
We designed and realized the front-end readout circuit for a matrix of silicon photomultipliers (SiPM), to be used in handheld dual particle imagers. In this work, we optically coupled two 6-mm by 6-mm by 6-mm stilbene crystals to two separate pixels on the same SiPM matrix and studied the performance of the readout architecture in terms of energy resolution and timing. A Na-22 source was placed on the array between the two pixels and energy and time resolution were measured. We varied the resistance of the AC stage of the readout circuit for each pixel by placing resistors of various resistance values in parallel with the signal readout jack. The energy resolution of the system improved with increasing resistance values, as expected. The time resolution in the 200 to 400 keV energy band did not vary significantly as a function of resistance value.
- Open Access
- 11 August 2017
- Published by Springer Nature in Scientific Reports
- Vol. 7 (1) , 1-10
Active neutron and gamma-ray imaging of highly enriched uranium for treaty verification
The detection and characterization of highly enriched uranium (HEU) presents a large challenge in the non-proliferation field. HEU has a low neutron emission rate and most gamma rays are low energy and easily shielded. To address this challenge, an instrument known as the dual-particle imager (DPI) was used with a portable deuterium-tritium (DT) neutron generator to detect neutrons and gamma rays from induced fission in HEU. We evaluated system response using a 13.7-kg HEU sphere in several configurations with no moderation, high-density polyethylene (HDPE) moderation, and tungsten moderation. A hollow tungsten sphere was interrogated to evaluate the response to a possible hoax item. First, localization capabilities were demonstrated by reconstructing neutron and gamma-ray images. Once localized, additional properties such as fast neutron energy spectra and time-dependent neutron count rates were attributed to the items. For the interrogated configurations containing HEU, the reconstructed neutron spectra resembled Watt spectra, which gave confidence that the interrogated items were undergoing induced fission. The time-dependent neutron count rate was also compared for each configuration and shown to be dependent on the neutron multiplication of the item. This result showed that the DPI is a viable tool for localizing and confirming fissile mass and multiplication.
- 11 August 2017
- Published by Springer Nature in Scientific Reports
- Vol. 7 (1) , 1-10
Open AccessActive neutron and gamma-ray imaging of highly enriched uranium for treaty verification
The detection and characterization of highly enriched uranium (HEU) presents a large challenge in the non-proliferation field. HEU has a low neutron emission rate and most gamma rays are low energy and easily shielded. To address this challenge, an instrument known as the dual-particle imager (DPI) was used with a portable deuterium-tritium (DT) neutron generator to detect neutrons and gamma rays from induced fission in HEU. We evaluated system response using a 13.7-kg HEU sphere in several configurations with no moderation, high-density polyethylene (HDPE) moderation, and tungsten moderation. A hollow tungsten sphere was interrogated to evaluate the response to a possible hoax item. First, localization capabilities were demonstrated by reconstructing neutron and gamma-ray images. Once localized, additional properties such as fast neutron energy spectra and time-dependent neutron count rates were attributed to the items. For the interrogated configurations containing HEU, the reconstructed neutron spectra resembled Watt spectra, which gave confidence that the interrogated items were undergoing induced fission. The time-dependent neutron count rate was also compared for each configuration and shown to be dependent on the neutron multiplication of the item. This result showed that the DPI is a viable tool for localizing and confirming fissile mass and multiplication.