Gwansuk Kang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Gwansuk Kang has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
- Dong-Guk Paeng
Department of Ocean System Engineering, Jeju National University, Jeju, Korea
2 shared publications - Joo Ha Hwang
Division of Gastroenterology and Hepatology, Department of Medicine, Stanford University, Stanford, California, USA
2 shared publications - Joon Hyouk Choi
Department of Internal Medicine, Jeju National University College of Medicine, Jeju, Republic of Korea
2 shared publications - Min Joo Choi
Interdisciplinary Postgraduate Program in Biomedical Engineering, Jeju National University, Jeju, Korea
2 shared publications - Andrew John Coleman
Medical Physics Department, Guy’s and St Thomas’ NHS Foundation Trust, London
1 shared publication - Cheong-Ah Lee
Faculty of Earth and Marine Convergence, Major Ocean Systems, Jeju National University, Jeju 63243, Republic of Korea
1 shared publication
Latest Publications
- 1 July 2026
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 160 (1) , 839-856
Cavitation bubble dynamics following lithotripter-induced shock wave-gas bubble interaction in viscous compressible blood
The equation of motion for a cavitation bubble following lithotripter-induced shock wave and gas bubble nucleus interaction in a viscous compressible blood is derived using the Keller–Miksis model, together by applying a Casson equation as a constitutive equation for blood flow, and numerical calculations have been performed for the initial bubble radii R0, 1–10 μm. Following the shock wave–gas bubble interaction, a cavitation bubble is formed when the shock wave pressure tail enters the negative pressure region, and it expands to reach the maximum radius Rmax. The Rmax value decreases linearly as R0 decreases for whole blood, plasma, and water. Among the three types of liquids, whole blood tends to exhibit the smallest Rmax value due to the influence of apparent viscosity. During cavitation bubble collapse, a high Reynolds number flow is developed in the whole blood, in which the apparent viscosity approaches Casson viscosity. Eventually, the bubble collapse dominated by inertial effect can produce impulsively high pressures on the order of several hundreds to thousands of gigapascals with the pulse width of 7.5 ps to 0.11 ns (i.e., full width at half maximum). A pair of impulsive collapse pressure pulses, with the collapse pressure ratio of 27–789, occur with the occurrence frequency of approximately 9 kHz for whole blood.
- 1 July 2026
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 160 (1) , 839-856
Cavitation bubble dynamics following lithotripter-induced shock wave-gas bubble interaction in viscous compressible blood
The equation of motion for a cavitation bubble following lithotripter-induced shock wave and gas bubble nucleus interaction in a viscous compressible blood is derived using the Keller–Miksis model, together by applying a Casson equation as a constitutive equation for blood flow, and numerical calculations have been performed for the initial bubble radii R0, 1–10 μm. Following the shock wave–gas bubble interaction, a cavitation bubble is formed when the shock wave pressure tail enters the negative pressure region, and it expands to reach the maximum radius Rmax. The Rmax value decreases linearly as R0 decreases for whole blood, plasma, and water. Among the three types of liquids, whole blood tends to exhibit the smallest Rmax value due to the influence of apparent viscosity. During cavitation bubble collapse, a high Reynolds number flow is developed in the whole blood, in which the apparent viscosity approaches Casson viscosity. Eventually, the bubble collapse dominated by inertial effect can produce impulsively high pressures on the order of several hundreds to thousands of gigapascals with the pulse width of 7.5 ps to 0.11 ns (i.e., full width at half maximum). A pair of impulsive collapse pressure pulses, with the collapse pressure ratio of 27–789, occur with the occurrence frequency of approximately 9 kHz for whole blood.
- Open Access
- 24 September 2024
- Published by Elsevier in Environmental Pollution
- Vol. 362, 125009
Preparation of fragmented polyethylene nanoplastics using a focused ultrasonic system and assessment of their cytotoxic effects on human cells
- 24 September 2024
- Published by Elsevier in Environmental Pollution
- Vol. 362, 125009
Open AccessPreparation of fragmented polyethylene nanoplastics using a focused ultrasonic system and assessment of their cytotoxic effects on human cells
- Open Access
- 4 July 2024
- Published by MDPI AG in Diagnostics
- Vol. 14 (13) , 1429
A Novel Method for Angiographic Contrast-Based Diagnosis of Stenosis in Coronary Artery Disease: In Vivo and In Vitro Analyses
Background: The existing diagnostic methods for coronary artery disease (CAD), such as coronary angiography and fractional flow reserve (FFR), have limitations regarding their invasiveness, cost, and discomfort. We explored a novel diagnostic approach, coronary contrast intensity analysis (CCIA), and conducted a comparative analysis between it and FFR. Methods: We used an in vitro coronary-circulation-mimicking system with nine stenosis models representing various stenosis lengths (6, 18, and 30 mm) and degrees (30%, 50%, and 70%). The angiographic brightness values were analyzed for CCIA. The in vivo experiments included 15 patients with a normal sinus rhythm. Coronary angiography was performed, and arterial movement was tracked, enabling CCIA derivation. The CCIA values were compared with the FFR (n = 15) and instantaneous wave-free ratio (iFR; n = 11) measurements. Results: In vitro FFR showed a consistent trend related to the length and severity of stenosis. The CCIA was related to stenosis but had a weaker correlation with length, except for with 70% stenosis (6 mm: 0.82 ± 0.007, 0.68 ± 0.007, 0.61 ± 0.004; 18 mm: 0.78 ± 0.052, 0.69 ± 0.025, 0.44 ± 0.016; 30 mm: 0.80 ± 0.018, 0.64 ± 0.006, 0.40 ± 0.026 at 30%, 50%, and 70%, respectively). In vitro CCIA and FFR were significantly correlated (R = 0.9442, p < 0.01). The in vivo analysis revealed significant correlations between CCIA and FFR (R = 0.5775, p < 0.05) and the iFR (n = 11, R = 0.7578, p < 0.01). Conclusions: CCIA is a promising alternative for diagnosing stenosis in patients with CAD. The initial in vitro validation and in vivo confirmation in patients demonstrate the feasibility of applying CCIA during coronary angiography. Further clinical studies are warranted to fully evaluate the diagnostic accuracy and potential impact of CCIA on CAD management.
- 4 July 2024
- Published by MDPI AG in Diagnostics
- Vol. 14 (13) , 1429
Open AccessA Novel Method for Angiographic Contrast-Based Diagnosis of Stenosis in Coronary Artery Disease: In Vivo and In Vitro Analyses
Background: The existing diagnostic methods for coronary artery disease (CAD), such as coronary angiography and fractional flow reserve (FFR), have limitations regarding their invasiveness, cost, and discomfort. We explored a novel diagnostic approach, coronary contrast intensity analysis (CCIA), and conducted a comparative analysis between it and FFR. Methods: We used an in vitro coronary-circulation-mimicking system with nine stenosis models representing various stenosis lengths (6, 18, and 30 mm) and degrees (30%, 50%, and 70%). The angiographic brightness values were analyzed for CCIA. The in vivo experiments included 15 patients with a normal sinus rhythm. Coronary angiography was performed, and arterial movement was tracked, enabling CCIA derivation. The CCIA values were compared with the FFR (n = 15) and instantaneous wave-free ratio (iFR; n = 11) measurements. Results: In vitro FFR showed a consistent trend related to the length and severity of stenosis. The CCIA was related to stenosis but had a weaker correlation with length, except for with 70% stenosis (6 mm: 0.82 ± 0.007, 0.68 ± 0.007, 0.61 ± 0.004; 18 mm: 0.78 ± 0.052, 0.69 ± 0.025, 0.44 ± 0.016; 30 mm: 0.80 ± 0.018, 0.64 ± 0.006, 0.40 ± 0.026 at 30%, 50%, and 70%, respectively). In vitro CCIA and FFR were significantly correlated (R = 0.9442, p < 0.01). The in vivo analysis revealed significant correlations between CCIA and FFR (R = 0.5775, p < 0.05) and the iFR (n = 11, R = 0.7578, p < 0.01). Conclusions: CCIA is a promising alternative for diagnosing stenosis in patients with CAD. The initial in vitro validation and in vivo confirmation in patients demonstrate the feasibility of applying CCIA during coronary angiography. Further clinical studies are warranted to fully evaluate the diagnostic accuracy and potential impact of CCIA on CAD management.
- Open Access
- 30 June 2022
- Published by Kosin University College of Medicine in Kosin Medical Journal
- Vol. 37 (2) , 96-101
How to write an original article in medicine and medical science
Excellent research in the fields of medicine and medical science can advance the field and contribute to human health improvement. In this aspect, research is important. However, if researchers do not publish their research, their efforts cannot benefit anyone. To make a difference, researchers must disseminate their results and communicate their opinions. One way to do this is by publishing their research. Therefore, academic writing is an essential skill for researchers. However, preparing a manuscript is not an easy task, and it is difficult to write well. Following a structure may be helpful for researchers. For example, the standard structure of medical and medical science articles includes the following sections: introduction, methods, results, and discussion (IMRAD). The purpose of this review is to present an introduction for researchers, especially novices, on how to write an original article in the field of medicine and medical science. Therefore, we discuss how to prepare and write a research manuscript for publication, using the IMRAD structure. We also included specific tips for writing manuscripts in medicine and medical science.
- 30 June 2022
- Published by Kosin University College of Medicine in Kosin Medical Journal
- Vol. 37 (2) , 96-101
Open AccessHow to write an original article in medicine and medical science
Excellent research in the fields of medicine and medical science can advance the field and contribute to human health improvement. In this aspect, research is important. However, if researchers do not publish their research, their efforts cannot benefit anyone. To make a difference, researchers must disseminate their results and communicate their opinions. One way to do this is by publishing their research. Therefore, academic writing is an essential skill for researchers. However, preparing a manuscript is not an easy task, and it is difficult to write well. Following a structure may be helpful for researchers. For example, the standard structure of medical and medical science articles includes the following sections: introduction, methods, results, and discussion (IMRAD). The purpose of this review is to present an introduction for researchers, especially novices, on how to write an original article in the field of medicine and medical science. Therefore, we discuss how to prepare and write a research manuscript for publication, using the IMRAD structure. We also included specific tips for writing manuscripts in medicine and medical science.
- Open Access
- 6 October 2021
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 12 (11) , 6717-6729
High-resolution photoacoustic/ultrasound imaging of the porcine stomach wall: an ex vivo feasibility study
Photoacoustic (PA) imaging has become invaluable in preclinical and clinical research. Endoscopic PA imaging in particular has been explored as a noninvasive imaging modality to view vasculature and diagnose cancers in the digestive system. However, these feasibility studies are still limited to rodents or rabbits. Here, we develop a fully synchronized simultaneous ultrasound and photoacoustic microscopy system using two spectral bands (i.e., the visible and near-infrared) in both optical- and acoustic-resolution modes. We investigate the feasibility of imaging gastric vasculature in an ex vivo porcine model. The entire gastric wall, including the mucosa, submucosa, muscularis propria, and serosa, was excised from fresh porcine stomachs immediately followed by ultrasound and PA imaging being performed within a few hours of sacrifice. PA images of the mucosal vasculature were obtained at depths of 1.90 mm, which is a clinically significant accomplishment considering that the average thickness of the human mucosa is 1.26 mm. The layer structure of the stomach wall could be clearly distinguished in the overlaid PA and US images. Because gastric cancer starts from the mucosal surface and infiltrates into the submucosa, PA imaging can cover a clinically relevant depth in early gastric cancer diagnosis. We were able to detect mucosal vasculature in the entire mucosal layer, suggesting the potential utility of combined PA/US imaging in gastroenterology.
- 6 October 2021
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 12 (11) , 6717-6729
Open AccessHigh-resolution photoacoustic/ultrasound imaging of the porcine stomach wall: an ex vivo feasibility study
Photoacoustic (PA) imaging has become invaluable in preclinical and clinical research. Endoscopic PA imaging in particular has been explored as a noninvasive imaging modality to view vasculature and diagnose cancers in the digestive system. However, these feasibility studies are still limited to rodents or rabbits. Here, we develop a fully synchronized simultaneous ultrasound and photoacoustic microscopy system using two spectral bands (i.e., the visible and near-infrared) in both optical- and acoustic-resolution modes. We investigate the feasibility of imaging gastric vasculature in an ex vivo porcine model. The entire gastric wall, including the mucosa, submucosa, muscularis propria, and serosa, was excised from fresh porcine stomachs immediately followed by ultrasound and PA imaging being performed within a few hours of sacrifice. PA images of the mucosal vasculature were obtained at depths of 1.90 mm, which is a clinically significant accomplishment considering that the average thickness of the human mucosa is 1.26 mm. The layer structure of the stomach wall could be clearly distinguished in the overlaid PA and US images. Because gastric cancer starts from the mucosal surface and infiltrates into the submucosa, PA imaging can cover a clinically relevant depth in early gastric cancer diagnosis. We were able to detect mucosal vasculature in the entire mucosal layer, suggesting the potential utility of combined PA/US imaging in gastroenterology.
- Open Access
- 25 January 2021
- Published by Springer Nature in BMC Cardiovascular Disorders
- Vol. 21 (1) , 1-12
The reasons why fractional flow reserve and instantaneous wave-free ratio are similar using wave separation analysis
Background and objectives: Fractional flow reserve (FFR) and instantaneous wave-free ratio (iFR) are the two most commonly used coronary indices of physiological stenosis severity based on pressure. To minimize the effect of wedge pressure (Pwedge), FFR is measured during hyperemia conditions, and iFR is calculated as the ratio of distal and aortic pressures (Pd/Pa) in the wave-free period. The goal of this study was to predict Pwedge using the backward wave (Pback) through wave separation analysis (WSA) and to reflect the effect of Pwedge on FFR and iFR to identify the relationship between the two indices. Methods: An in vitro circulation system was constructed to calculate Pwedge. The measurements were performed in cases with stenosis percentages of 48, 71, and 88% and with hydrostatic pressures of 10 and 30 mmHg. Then, the correlation between Pback by WSA and Pwedge was calculated. In vivo coronary flow and pressure were simultaneously measured for 11 vessels in all patients. The FFR and iFR values were reconstructed as the ratios of forward wave at distal and proximal sites during hyperemia and at rest, respectively. Results: Based on the in vitro results, the correlation between Pback and Pwedge was high (r = 0.990, p < 0.0001). In vivo results showed high correlations between FFR and reconstructed FFR (r = 0.992, p < 0.001) and between iFR and reconstructed iFR (r = 0.930, p < 0.001). Conclusions: Reconstructed FFR and iFR were in good agreement with conventional FFR and iFR. FFR and iFR can be expressed as the variation of trans-stenotic forward pressure, indicating that the two values are inferred from the same formula under different conditions.
- 25 January 2021
- Published by Springer Nature in BMC Cardiovascular Disorders
- Vol. 21 (1) , 1-12
Open AccessThe reasons why fractional flow reserve and instantaneous wave-free ratio are similar using wave separation analysis
Background and objectives: Fractional flow reserve (FFR) and instantaneous wave-free ratio (iFR) are the two most commonly used coronary indices of physiological stenosis severity based on pressure. To minimize the effect of wedge pressure (Pwedge), FFR is measured during hyperemia conditions, and iFR is calculated as the ratio of distal and aortic pressures (Pd/Pa) in the wave-free period. The goal of this study was to predict Pwedge using the backward wave (Pback) through wave separation analysis (WSA) and to reflect the effect of Pwedge on FFR and iFR to identify the relationship between the two indices. Methods: An in vitro circulation system was constructed to calculate Pwedge. The measurements were performed in cases with stenosis percentages of 48, 71, and 88% and with hydrostatic pressures of 10 and 30 mmHg. Then, the correlation between Pback by WSA and Pwedge was calculated. In vivo coronary flow and pressure were simultaneously measured for 11 vessels in all patients. The FFR and iFR values were reconstructed as the ratios of forward wave at distal and proximal sites during hyperemia and at rest, respectively. Results: Based on the in vitro results, the correlation between Pback and Pwedge was high (r = 0.990, p < 0.0001). In vivo results showed high correlations between FFR and reconstructed FFR (r = 0.992, p < 0.001) and between iFR and reconstructed iFR (r = 0.930, p < 0.001). Conclusions: Reconstructed FFR and iFR were in good agreement with conventional FFR and iFR. FFR and iFR can be expressed as the variation of trans-stenotic forward pressure, indicating that the two values are inferred from the same formula under different conditions.
- Open Access
- 27 January 2015
- Published by Korean Society of Ultrasound in Medicine in Ultrasonography
- Vol. 34 (2) , 109-114
The role of the acoustic radiation force in color Doppler twinkling artifacts
The aim of this experimental study was to evaluate whether the acoustic radiation force (ARF) is a potential source of twinkling artifacts in color Doppler images. Color Doppler images were obtained using a clinical ultrasonic scanner (Voluson e, GE Healthcare) for a high contrast (+15 dB) circular scattering phantom at pulse repetition frequencies (PRFs) ranging from 0.1 to 13 kHz. Ultrasound transmissions resulting in ARF were measured using a hydrophone at the various PRFs considered. The influence of ARF on the appearance of twinkling colors was examined via the common parameter PRF. This methodology is based on the fact that alternating positive and negative Doppler shifts induced by the ARF are centered at a PRF twice the maximum Doppler frequency on the color scale bar, whereas the twinkling color aliasing is expected to remain similar regardless of PRF. Color twinkling artifacts were observed to be most conspicuous at the lowest PRF of 0.1 kHz. The extent of twinkling rapidly decreased as the PRF increased, eventually disappearing when the PRF ≥0.6 kHz. The measured ultrasound transmissions, however, were found to be insensitive to the PRF, and therefore it can be inferred that the PRF was insensitive to the ARF. Based on our experimental observations, the ARF may not be a source of color Doppler twinkling artifacts.
- 27 January 2015
- Published by Korean Society of Ultrasound in Medicine in Ultrasonography
- Vol. 34 (2) , 109-114
Open AccessThe role of the acoustic radiation force in color Doppler twinkling artifacts
The aim of this experimental study was to evaluate whether the acoustic radiation force (ARF) is a potential source of twinkling artifacts in color Doppler images. Color Doppler images were obtained using a clinical ultrasonic scanner (Voluson e, GE Healthcare) for a high contrast (+15 dB) circular scattering phantom at pulse repetition frequencies (PRFs) ranging from 0.1 to 13 kHz. Ultrasound transmissions resulting in ARF were measured using a hydrophone at the various PRFs considered. The influence of ARF on the appearance of twinkling colors was examined via the common parameter PRF. This methodology is based on the fact that alternating positive and negative Doppler shifts induced by the ARF are centered at a PRF twice the maximum Doppler frequency on the color scale bar, whereas the twinkling color aliasing is expected to remain similar regardless of PRF. Color twinkling artifacts were observed to be most conspicuous at the lowest PRF of 0.1 kHz. The extent of twinkling rapidly decreased as the PRF increased, eventually disappearing when the PRF ≥0.6 kHz. The measured ultrasound transmissions, however, were found to be insensitive to the PRF, and therefore it can be inferred that the PRF was insensitive to the ARF. Based on our experimental observations, the ARF may not be a source of color Doppler twinkling artifacts.
- 1 March 2014
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 135 (3) , 1139-1148
Characterization of the shock pulse-induced cavitation bubble activities recorded by an optical fiber hydrophone
A shock pressure pulse used in an extracorporeal shock wave treatment has a large negative pressure (<-5 MPa) which can produce cavitation. Cavitation cannot be measured easily, but may have known therapeutic effects. This study considers the signal recorded for several hundred microseconds using an optical hydrophone submerged in water at the focus of shock pressure field. The signal is characterized by shock pulse followed by a long tail after several microseconds; this signal is regarded as a cavitation-related signal (CRS). An experimental investigation of the CRS was conducted in the shock pressure field produced in water using an optical hydrophone (FOPH2000, RP Acoustics, Germany). The CRS was found to contain characteristic information about the shock pulse-induced cavitation. The first and second collapse times (t1 and t2) were identified in the CRS. The collapse time delay (tc = t2 - t1) increased with the driving shock pressures. The signal amplitude integrated for time from t1 to t2 was highly correlated with tc (adjusted R(2) = 0.990). This finding suggests that a single optical hydrophone can be used to measure shock pulse and to characterize shock pulse-induced cavitation.
- 1 March 2014
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 135 (3) , 1139-1148
Characterization of the shock pulse-induced cavitation bubble activities recorded by an optical fiber hydrophone
A shock pressure pulse used in an extracorporeal shock wave treatment has a large negative pressure (<-5 MPa) which can produce cavitation. Cavitation cannot be measured easily, but may have known therapeutic effects. This study considers the signal recorded for several hundred microseconds using an optical hydrophone submerged in water at the focus of shock pressure field. The signal is characterized by shock pulse followed by a long tail after several microseconds; this signal is regarded as a cavitation-related signal (CRS). An experimental investigation of the CRS was conducted in the shock pressure field produced in water using an optical hydrophone (FOPH2000, RP Acoustics, Germany). The CRS was found to contain characteristic information about the shock pulse-induced cavitation. The first and second collapse times (t1 and t2) were identified in the CRS. The collapse time delay (tc = t2 - t1) increased with the driving shock pressures. The signal amplitude integrated for time from t1 to t2 was highly correlated with tc (adjusted R(2) = 0.990). This finding suggests that a single optical hydrophone can be used to measure shock pulse and to characterize shock pulse-induced cavitation.