Randy K. Kalkman
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Randy K. Kalkman has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Johannes Hubertus Maria Frijns
Department of Otorhinolaryngology and Head & Neck Surgery, Leiden University Medical Center, Leiden, Netherlands
8 shared publications - Jeroen Johannes Briaire
Department of Otorhinolaryngology and Head & Neck Surgery, Leiden University Medical Center
5 shared publications Jeroen J. Briaire
Department of Otorhinolaryngology and Head & Neck Surgery, Leiden University Medical Center, PO Box 9600, 2300 RC, Leiden, the Netherlands
3 shared publications- Margriet J. van Gendt
ENT-Department, Leiden University Medical Centre, PO Box 9600, 2300 RC, Leiden, The Netherlands
2 shared publications Berit M. Verbist
Department of Radiology, Leiden University Medical Center, PO Box 9600, 2300 RC, Leiden, The Netherlands
1 shared publicationDavid M. Baguley
Addenbrookes NHS Trust, Cambridge, England
1 shared publication
Latest Publications
- Open Access
- 1 August 2025
- Published by MDPI AG in Technologies
- Vol. 13 (8) , 331
Neural Correlates of Loudness Coding in Two Types of Cochlear Implants—A Model Study
Many speech coding strategies have been developed over the years, but comparing them has been convoluted due to the difficulty in disentangling brand-specific and patient-specific factors from strategy-specific factors that contribute to speech understanding. Here, we present a comparison with a ‘virtual’ patient, by comparing two strategies from two different manufacturers, Advanced Combination Encoder (ACE) versus HiResolution Fidelity 120 (F120), running on two different implant systems in a computational model with the same anatomy and neural properties. We fitted both strategies to an expected T-level and C- or M-level based on the spike rate for each electrode contact’s allocated frequency (center electrode frequency) of the respective array. This paper highlights neural and electrical differences due to brand-specific characteristics such as pulse rate/channel, recruitment of adjacent electrodes, and presence of subthreshold pulses or interphase gaps. These differences lead to considerably different recruitment patterns of nerve fibers, while achieving the same total spike rates, i.e., loudness percepts. Also, loudness growth curves differ significantly between brands. The model is able to demonstrate considerable electrical and neural differences in the way loudness growth is achieved in CIs from different manufacturers.
- 1 August 2025
- Published by MDPI AG in Technologies
- Vol. 13 (8) , 331
Open AccessNeural Correlates of Loudness Coding in Two Types of Cochlear Implants—A Model Study
Many speech coding strategies have been developed over the years, but comparing them has been convoluted due to the difficulty in disentangling brand-specific and patient-specific factors from strategy-specific factors that contribute to speech understanding. Here, we present a comparison with a ‘virtual’ patient, by comparing two strategies from two different manufacturers, Advanced Combination Encoder (ACE) versus HiResolution Fidelity 120 (F120), running on two different implant systems in a computational model with the same anatomy and neural properties. We fitted both strategies to an expected T-level and C- or M-level based on the spike rate for each electrode contact’s allocated frequency (center electrode frequency) of the respective array. This paper highlights neural and electrical differences due to brand-specific characteristics such as pulse rate/channel, recruitment of adjacent electrodes, and presence of subthreshold pulses or interphase gaps. These differences lead to considerably different recruitment patterns of nerve fibers, while achieving the same total spike rates, i.e., loudness percepts. Also, loudness growth curves differ significantly between brands. The model is able to demonstrate considerable electrical and neural differences in the way loudness growth is achieved in CIs from different manufacturers.
- Open Access
Automated segmentation of clinical CT scans of the cochlea and analysis of the cochlea's vertical profile
- Open Access
- 25 March 2022
- Published by Elsevier in Hearing Research
- Vol. 420, 108490
The effect of stimulus level on excitation patterns of individual electrode contacts in cochlear implants
- 25 March 2022
- Published by Elsevier in Hearing Research
- Vol. 420, 108490
Open AccessThe effect of stimulus level on excitation patterns of individual electrode contacts in cochlear implants
- 1 August 2017
- Published by Elsevier in Hearing Research
- Vol. 351, 19-33
Modeled auditory nerve responses to amplitude modulated cochlear implant stimulation
- 1 August 2017
- Published by Elsevier in Hearing Research
- Vol. 351, 19-33
Modeled auditory nerve responses to amplitude modulated cochlear implant stimulation
- 1 November 2016
- Published by Elsevier in Hearing Research
- Vol. 341, 130-143
A fast, stochastic, and adaptive model of auditory nerve responses to cochlear implant stimulation
- 1 November 2016
- Published by Elsevier in Hearing Research
- Vol. 341, 130-143
A fast, stochastic, and adaptive model of auditory nerve responses to cochlear implant stimulation
- 1 September 2014
- Published by Elsevier in Hearing Research
- Vol. 315, 10-24
Place pitch versus electrode location in a realistic computational model of the implanted human cochlea
- 1 September 2014
- Published by Elsevier in Hearing Research
- Vol. 315, 10-24
Place pitch versus electrode location in a realistic computational model of the implanted human cochlea
- 22 May 2013
- Published by Springer Nature in Journal of the Association for Research in Otolaryngology
- Vol. 14 (5) , 781-790
Threshold Levels of Dual Electrode Stimulation in Cochlear Implants
Simultaneous stimulation on two contacts (current steering) creates intermediate pitches between the physical contacts in cochlear implants. All recent studies on current steering have focused on Most Comfortable Loudness levels and not at low stimulation levels. This study investigates the efficacy of dual electrode stimulation at lower levels, thereby focusing on the requirements to correct for threshold variations. With a current steered signal, threshold levels were determined on 4 different electrode pairs for 7 different current steering coefficients (α). This was done psychophysically in twelve postlingually deafened cochlear implant (HiRes90K, HiFocus1J) users and, in a computer model, which made use of three different neural morphologies. The analysis on the psychophysical data taking all subjects into account showed that in all conditions there was no significant difference between the threshold level of the physical contacts and the intermediate created percepts, eliminating the need for current corrections at these very low levels. The model data showed unexpected drops in threshold in the middle of the two physical contacts (both contacts equal current). Results consistent with this prediction were obtained for a subset of 5 subjects for the apical pair with wider spacing (2.2 mm). Further analysis showed that this decrease was only observed in subjects with a long duration of deafness. For current steering on adjacent contacts, the results from the psychophysical experiments were in line with the results from computational modelling. However, the dip in the threshold profile could only be replicated in the computational model with surviving peripheral processes without an unmyelinated terminal. On the basis of this result, we put forward that the majority of the surviving spiral ganglion cells in the cochlea in humans with a long duration of deafness still retain peripheral processes, but have lost their unmyelinated terminals.
- 22 May 2013
- Published by Springer Nature in Journal of the Association for Research in Otolaryngology
- Vol. 14 (5) , 781-790
Threshold Levels of Dual Electrode Stimulation in Cochlear Implants
Simultaneous stimulation on two contacts (current steering) creates intermediate pitches between the physical contacts in cochlear implants. All recent studies on current steering have focused on Most Comfortable Loudness levels and not at low stimulation levels. This study investigates the efficacy of dual electrode stimulation at lower levels, thereby focusing on the requirements to correct for threshold variations. With a current steered signal, threshold levels were determined on 4 different electrode pairs for 7 different current steering coefficients (α). This was done psychophysically in twelve postlingually deafened cochlear implant (HiRes90K, HiFocus1J) users and, in a computer model, which made use of three different neural morphologies. The analysis on the psychophysical data taking all subjects into account showed that in all conditions there was no significant difference between the threshold level of the physical contacts and the intermediate created percepts, eliminating the need for current corrections at these very low levels. The model data showed unexpected drops in threshold in the middle of the two physical contacts (both contacts equal current). Results consistent with this prediction were obtained for a subset of 5 subjects for the apical pair with wider spacing (2.2 mm). Further analysis showed that this decrease was only observed in subjects with a long duration of deafness. For current steering on adjacent contacts, the results from the psychophysical experiments were in line with the results from computational modelling. However, the dip in the threshold profile could only be replicated in the computational model with surviving peripheral processes without an unmyelinated terminal. On the basis of this result, we put forward that the majority of the surviving spiral ganglion cells in the cochlea in humans with a long duration of deafness still retain peripheral processes, but have lost their unmyelinated terminals.
- 1 October 2010
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 128 (4_Suppleme) , 2425
Pitch comparisons between cochlear-implant stimulation and sounds played to a normal-hearing contralateral ear.
A small group of cochlear implant users, having normal hearing in the unimplanted ear, compared the pitches of electrical and acoustic stimuli presented to the two ears. Comparisons were between 1031‐pps pulse trains and pure tones or between 12‐ or 25‐pps electric pulse trains and bandpass filtered acoustic pulse trains of the same rate. Three methods (pitch adjustment, constant stimuli, and interleaved adaptive procedures) were used. For all methods, we showed that the results can be strongly influenced by non‐sensory biases arising from the range of acoustic stimuli presented, and proposed a series of checks that should be made to alert the experimenter to those biases. We then showed that the results of comparisons that survived these checks do not deviate consistently from the predictions of a widely used cochlear frequency‐to‐place formula or of a computational cochlear model. In one case, the matches were reliable enough to successfully reveal the movement (slippage) of the electrode array. We also demonstrate that substantial range effects occur with other widely used experimental methods, even for normal‐hearing listeners.
- 1 October 2010
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 128 (4_Suppleme) , 2425
Pitch comparisons between cochlear-implant stimulation and sounds played to a normal-hearing contralateral ear.
A small group of cochlear implant users, having normal hearing in the unimplanted ear, compared the pitches of electrical and acoustic stimuli presented to the two ears. Comparisons were between 1031‐pps pulse trains and pure tones or between 12‐ or 25‐pps electric pulse trains and bandpass filtered acoustic pulse trains of the same rate. Three methods (pitch adjustment, constant stimuli, and interleaved adaptive procedures) were used. For all methods, we showed that the results can be strongly influenced by non‐sensory biases arising from the range of acoustic stimuli presented, and proposed a series of checks that should be made to alert the experimenter to those biases. We then showed that the results of comparisons that survived these checks do not deviate consistently from the predictions of a widely used cochlear frequency‐to‐place formula or of a computational cochlear model. In one case, the matches were reliable enough to successfully reveal the movement (slippage) of the electrode array. We also demonstrate that substantial range effects occur with other widely used experimental methods, even for normal‐hearing listeners.