Paul Claude Diemoz
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Paul Claude Diemoz has a total of 135 co-authors. Here are the top co-authors by number of shared publications:
- Alessandro Olivo
University College London
44 shared publications - Marco Endrizzi
University College London
36 shared publications - Paola Coan
Faculty of Medicine and Institute of Clinical Radiology, Ludwig-Maximilians University, Munich, Germany
14 shared publications - Ian K. Robinson
Brookhaven National Laboratory
13 shared publications Fabio A. Vittoria
Department of Medical Physics and Biomedical Engineering, University College London, London, UK; Research Complex at Harwell, Oxford Harwell Campus, Didcot, UK
11 shared publicationsC. K. Hagen
Department of Medical Physics and Biomedical Engineering, UCL, WC1E 6BT London, United Kingdom
10 shared publications
Latest Publications
- 30 March 2026
- Published by Agence Bibliographique de l'Enseignement Supérieur
Contributions expérimentales et théoriques aux techniques de contraste de phase pour l'imagerie médicale par rayons X
Différentes techniques d'imagerie par contraste de phase des rayons X ont été récemment développées. Contrairement aux méthodes conventionnelles, qui mesurent les propriétés d'absorption des tissus, ces techniques donnent aussi le contraste du déphasage introduit par l'échantillon. Puisque le changement dans la phase peut être important même quand les différences en atténuation sont faibles ou absentes, le contraste d'image obtenable peut être considérablement augmenté, notamment pour les tissus mous biologiques. Ces méthodes sont donc très prometteuses pour une application dans le domaine médical. Cette Thèse a le but de contribuer à une compréhension plus profonde de ces techniques, en particulier la propagation-based imaging (PBI), la analyzer-based imaging (ABI) et la grating interferometry (GIFM), et d'étudier leur potentiel et la meilleure implémentation pratique pour les applications médicales. Une partie importante de cette Thèse est dédiée à l'utilisation d'algorithmes mathématiques pour l'extraction, à partir des images acquises, d'informations quantitatives (absorption, réfraction et diffusion) concernant l'échantillon. En particulier, cinq parmi les algorithmes les plus connus pour la technique ABI sont analysés théoriquement et comparés expérimentalement, dans les modalités planaire et tomographique, en utilisant des fantômes et des échantillons de tissu mammaire et d'os-cartilage. Une méthode semi-quantitative pour l'acquisition et la reconstruction d'images tomographiques dans les techniques ABI et GIFM est aussi proposée. Les conditions de validité sont analysées en détail et la méthode, permettant une simplification considérable de l'implémentation pratique, est vérifiée expérimentalement sur des fantômes et des échantillons humains. Enfin, une comparaison théorique et expérimentale des techniques PBI, ABI et GIFM est présentée. Les avantages et les désavantages de chacune des techniques sont mis en évidence. Les résultats obtenus par cette analyse peuvent être très utiles pour déterminer quelle technique est la plus adaptée à une application donnée.
- 30 March 2026
- Published by Agence Bibliographique de l'Enseignement Supérieur
Contributions expérimentales et théoriques aux techniques de contraste de phase pour l'imagerie médicale par rayons X
Différentes techniques d'imagerie par contraste de phase des rayons X ont été récemment développées. Contrairement aux méthodes conventionnelles, qui mesurent les propriétés d'absorption des tissus, ces techniques donnent aussi le contraste du déphasage introduit par l'échantillon. Puisque le changement dans la phase peut être important même quand les différences en atténuation sont faibles ou absentes, le contraste d'image obtenable peut être considérablement augmenté, notamment pour les tissus mous biologiques. Ces méthodes sont donc très prometteuses pour une application dans le domaine médical. Cette Thèse a le but de contribuer à une compréhension plus profonde de ces techniques, en particulier la propagation-based imaging (PBI), la analyzer-based imaging (ABI) et la grating interferometry (GIFM), et d'étudier leur potentiel et la meilleure implémentation pratique pour les applications médicales. Une partie importante de cette Thèse est dédiée à l'utilisation d'algorithmes mathématiques pour l'extraction, à partir des images acquises, d'informations quantitatives (absorption, réfraction et diffusion) concernant l'échantillon. En particulier, cinq parmi les algorithmes les plus connus pour la technique ABI sont analysés théoriquement et comparés expérimentalement, dans les modalités planaire et tomographique, en utilisant des fantômes et des échantillons de tissu mammaire et d'os-cartilage. Une méthode semi-quantitative pour l'acquisition et la reconstruction d'images tomographiques dans les techniques ABI et GIFM est aussi proposée. Les conditions de validité sont analysées en détail et la méthode, permettant une simplification considérable de l'implémentation pratique, est vérifiée expérimentalement sur des fantômes et des échantillons humains. Enfin, une comparaison théorique et expérimentale des techniques PBI, ABI et GIFM est présentée. Les avantages et les désavantages de chacune des techniques sont mis en évidence. Les résultats obtenus par cette analyse peuvent être très utiles pour déterminer quelle technique est la plus adaptée à une application donnée.
- Open Access
- 28 April 2017
- Published by American Physical Society (APS) in Physical Review Applied
- Vol. 7 (4) , 044029
Single-Shot X-Ray Phase-Contrast Computed Tomography with Nonmicrofocal Laboratory Sources
We present a method that enables performing x-ray phase-contrast imaging (XPCI) computed tomography with a laboratory setup using a single image per projection angle, eliminating the need to move optical elements during acquisition. Theoretical derivation of the method is presented, and its validity conditions are provided. The object is assumed to be quasihomogeneous, i.e., to feature a ratio between the refractive index and the linear attenuation coefficient that is approximately constant across the field of view. The method is experimentally demonstrated on a plastics phantom and on biological samples using a continuous rotation acquisition scheme achieving scan times of a few minutes. Moreover, we show that such acquisition times can be further reduced with the use of a high-efficiency photon-counting detector. Thanks to its ability to substantially simplify the image-acquisition procedure and greatly reduce collection times, we believe this method represents a very important step towards the application of XPCI to real-world problems.
- 28 April 2017
- Published by American Physical Society (APS) in Physical Review Applied
- Vol. 7 (4) , 044029
Open AccessSingle-Shot X-Ray Phase-Contrast Computed Tomography with Nonmicrofocal Laboratory Sources
We present a method that enables performing x-ray phase-contrast imaging (XPCI) computed tomography with a laboratory setup using a single image per projection angle, eliminating the need to move optical elements during acquisition. Theoretical derivation of the method is presented, and its validity conditions are provided. The object is assumed to be quasihomogeneous, i.e., to feature a ratio between the refractive index and the linear attenuation coefficient that is approximately constant across the field of view. The method is experimentally demonstrated on a plastics phantom and on biological samples using a continuous rotation acquisition scheme achieving scan times of a few minutes. Moreover, we show that such acquisition times can be further reduced with the use of a high-efficiency photon-counting detector. Thanks to its ability to substantially simplify the image-acquisition procedure and greatly reduce collection times, we believe this method represents a very important step towards the application of XPCI to real-world problems.
- 3 April 2017
- Published by Wiley in Medical Physics
- Vol. 44 (5) , 1876-1885
On the relative performance of edge illumination x-ray phase-contrast CT and conventional, attenuation-based CT
These results imply that EI PCT could outperform CT in applications for which high spatial resolutions are key, e.g., small animal or specimen imaging.
- 3 April 2017
- Published by Wiley in Medical Physics
- Vol. 44 (5) , 1876-1885
On the relative performance of edge illumination x-ray phase-contrast CT and conventional, attenuation-based CT
These results imply that EI PCT could outperform CT in applications for which high spatial resolutions are key, e.g., small animal or specimen imaging.
- Open Access
- 1 December 2016
- Published by Elsevier in Physica Medica
- Vol. 32 (12) , 1759-1764
A single-image retrieval method for edge illumination X-ray phase-contrast imaging: Application and noise analysis
- 1 December 2016
- Published by Elsevier in Physica Medica
- Vol. 32 (12) , 1759-1764
Open AccessA single-image retrieval method for edge illumination X-ray phase-contrast imaging: Application and noise analysis
- Open Access
- 26 May 2016
- Published by IOP Publishing in Journal of Physics D: Applied Physics
- Vol. 49 (25) , 255501
Reverse projection retrieval in edge illumination x-ray phase contrast computed tomography
- 26 May 2016
- Published by IOP Publishing in Journal of Physics D: Applied Physics
- Vol. 49 (25) , 255501
Open AccessReverse projection retrieval in edge illumination x-ray phase contrast computed tomography
- Open Access
- 13 May 2016
- Published by Optica Publishing Group in Optics Express
- Vol. 24 (10) , 11250-11265
Concept of contrast transfer function for edge illumination x-ray phase-contrast imaging and its comparison with the free-space propagation technique
Previous studies on edge illumination (EI) X-ray phase-contrast imaging (XPCi) have investigated the nature and amplitude of the signal provided by this technique. However, the response of the imaging system to different object spatial frequencies was never explicitly considered and studied. This is required in order to predict the performance of a given EI setup for different classes of objects. To this scope, in the present work we derive analytical expressions for the contrast transfer function of an EI imaging system, using the approximation of near-field regime, and study its dependence upon the main experimental parameters. We then exploit these results to compare the frequency response of an EI system with respect of that of a free-space propagation XPCi one. The results achieved in this work can be useful for predicting the signals obtainable for different types of objects and also as a basis for new retrieval methods.
- 13 May 2016
- Published by Optica Publishing Group in Optics Express
- Vol. 24 (10) , 11250-11265
Open AccessConcept of contrast transfer function for edge illumination x-ray phase-contrast imaging and its comparison with the free-space propagation technique
Previous studies on edge illumination (EI) X-ray phase-contrast imaging (XPCi) have investigated the nature and amplitude of the signal provided by this technique. However, the response of the imaging system to different object spatial frequencies was never explicitly considered and studied. This is required in order to predict the performance of a given EI setup for different classes of objects. To this scope, in the present work we derive analytical expressions for the contrast transfer function of an EI imaging system, using the approximation of near-field regime, and study its dependence upon the main experimental parameters. We then exploit these results to compare the frequency response of an EI system with respect of that of a free-space propagation XPCi one. The results achieved in this work can be useful for predicting the signals obtainable for different types of objects and also as a basis for new retrieval methods.
- 1 February 2016
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 89 (1058) , 20150565
X-ray phase contrast tomography; proof of principle for post-mortem imaging
Objectives:To demonstrate the feasibility of using X-ray phase contrast tomography to assess internal organs in a post-mortem piglet model, as a possible non-invasive imaging autopsy technique.Methods:Tomographic images of a new-born piglet were obtained using a Free Space Propagation (FSP) X-ray phase contrast imaging setup at a synchrotron (European Synchrotron Radiation Facility, Grenoble, France). A monochromatic X-ray beam (52 keV) was used in combination with a detector pixel size of 46x46 µm2. A phase-retrieval algorithm was applied to all projections, which were then reconstructed into tomograms using the filtered-back projection algorithm. Images were assessed for diagnostic quality.Results:Images obtained with the FSP setup presented high soft tissue contrast and sufficient resolution for resolving organ structure. All of the main body organs (heart, lungs, kidneys, liver and intestines) were easily identified and adequately visualised. In addition, grey/white matter differentiation in the cereb...
- 1 February 2016
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 89 (1058) , 20150565
X-ray phase contrast tomography; proof of principle for post-mortem imaging
Objectives:To demonstrate the feasibility of using X-ray phase contrast tomography to assess internal organs in a post-mortem piglet model, as a possible non-invasive imaging autopsy technique.Methods:Tomographic images of a new-born piglet were obtained using a Free Space Propagation (FSP) X-ray phase contrast imaging setup at a synchrotron (European Synchrotron Radiation Facility, Grenoble, France). A monochromatic X-ray beam (52 keV) was used in combination with a detector pixel size of 46x46 µm2. A phase-retrieval algorithm was applied to all projections, which were then reconstructed into tomograms using the filtered-back projection algorithm. Images were assessed for diagnostic quality.Results:Images obtained with the FSP setup presented high soft tissue contrast and sufficient resolution for resolving organ structure. All of the main body organs (heart, lungs, kidneys, liver and intestines) were easily identified and adequately visualised. In addition, grey/white matter differentiation in the cereb...
- Open Access
- 14 December 2015
- Published by Springer Nature in Scientific Reports
- Vol. 5 (1) , 18156
High contrast microstructural visualization of natural acellular matrices by means of phase-based x-ray tomography
Acellular scaffolds obtained via decellularization are a key instrument in regenerative medicine both per se and to drive the development of future-generation synthetic scaffolds that could become available off-the-shelf. In this framework, imaging is key to the understanding of the scaffolds’ internal structure as well as their interaction with cells and other organs, including ideally post-implantation. Scaffolds of a wide range of intricate organs (esophagus, lung, liver and small intestine) were imaged with x-ray phase contrast computed tomography (PC-CT). Image quality was sufficiently high to visualize scaffold microarchitecture and to detect major anatomical features, such as the esophageal mucosal-submucosal separation, pulmonary alveoli and intestinal villi. These results are a long-sought step for the field of regenerative medicine; until now, histology and scanning electron microscopy have been the gold standard to study the scaffold structure. However, they are both destructive: hence, they are not suitable for imaging scaffolds prior to transplantation and have no prospect for post-transplantation use. PC-CT, on the other hand, is non-destructive, 3D and fully quantitative. Importantly, not only do we demonstrate achievement of high image quality at two different synchrotron facilities, but also with commercial x-ray equipment, which makes the method available to any research laboratory.
- 14 December 2015
- Published by Springer Nature in Scientific Reports
- Vol. 5 (1) , 18156
Open AccessHigh contrast microstructural visualization of natural acellular matrices by means of phase-based x-ray tomography
Acellular scaffolds obtained via decellularization are a key instrument in regenerative medicine both per se and to drive the development of future-generation synthetic scaffolds that could become available off-the-shelf. In this framework, imaging is key to the understanding of the scaffolds’ internal structure as well as their interaction with cells and other organs, including ideally post-implantation. Scaffolds of a wide range of intricate organs (esophagus, lung, liver and small intestine) were imaged with x-ray phase contrast computed tomography (PC-CT). Image quality was sufficiently high to visualize scaffold microarchitecture and to detect major anatomical features, such as the esophageal mucosal-submucosal separation, pulmonary alveoli and intestinal villi. These results are a long-sought step for the field of regenerative medicine; until now, histology and scanning electron microscopy have been the gold standard to study the scaffold structure. However, they are both destructive: hence, they are not suitable for imaging scaffolds prior to transplantation and have no prospect for post-transplantation use. PC-CT, on the other hand, is non-destructive, 3D and fully quantitative. Importantly, not only do we demonstrate achievement of high image quality at two different synchrotron facilities, but also with commercial x-ray equipment, which makes the method available to any research laboratory.
- Open Access
- 16 November 2015
- Published by AIP Publishing in Applied Physics Letters
- Vol. 107 (20) , 204105
A laboratory based edge-illumination x-ray phase-contrast imaging setup with two-directional sensitivity
We report on a preliminary laboratory based x-ray phase-contrast imaging system capable of achieving two-directional phase sensitivity, thanks to the use of L-shaped apertures. We show that in addition to apparent absorption, two-directional differential phase images of an object can be quantitatively retrieved by using only three input images. We also verify that knowledge of the phase derivatives along both directions allows for straightforward phase integration with no streak artefacts, a known problem common to all differential phase techniques. In addition, an analytical method for 2-directional dark field retrieval is proposed and experimentally demonstrated.
- 16 November 2015
- Published by AIP Publishing in Applied Physics Letters
- Vol. 107 (20) , 204105
Open AccessA laboratory based edge-illumination x-ray phase-contrast imaging setup with two-directional sensitivity
We report on a preliminary laboratory based x-ray phase-contrast imaging system capable of achieving two-directional phase sensitivity, thanks to the use of L-shaped apertures. We show that in addition to apparent absorption, two-directional differential phase images of an object can be quantitatively retrieved by using only three input images. We also verify that knowledge of the phase derivatives along both directions allows for straightforward phase integration with no streak artefacts, a known problem common to all differential phase techniques. In addition, an analytical method for 2-directional dark field retrieval is proposed and experimentally demonstrated.
- Open Access
- 6 November 2015
- Published by Springer Nature in Scientific Reports
- Vol. 5 (1) , 16318
X–ray absorption, phase and dark–field tomography through a beam tracking approach
We present a development of the beam–tracking approach that allows its implementation in computed tomography. One absorbing mask placed before the sample and a high resolution detector are used to track variations in the beam intensity distribution caused by the sample. Absorption, refraction, and dark–field are retrieved through a multi–Gaussian interpolation of the beam. Standard filtered back projection is used to reconstruct three dimensional maps of the real and imaginary part of the refractive index, and of the dark–field signal. While the method is here demonstrated using synchrotron radiation, its low coherence requirements suggest a possible implementation with laboratory sources.
- 6 November 2015
- Published by Springer Nature in Scientific Reports
- Vol. 5 (1) , 16318
Open AccessX–ray absorption, phase and dark–field tomography through a beam tracking approach
We present a development of the beam–tracking approach that allows its implementation in computed tomography. One absorbing mask placed before the sample and a high resolution detector are used to track variations in the beam intensity distribution caused by the sample. Absorption, refraction, and dark–field are retrieved through a multi–Gaussian interpolation of the beam. Standard filtered back projection is used to reconstruct three dimensional maps of the real and imaginary part of the refractive index, and of the dark–field signal. While the method is here demonstrated using synchrotron radiation, its low coherence requirements suggest a possible implementation with laboratory sources.