SOSaban Ozdemir

Saban Ozdemir

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Saban Ozdemir has a total of 26 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • A Novel Hybrid-Core Structure for Split-Core Inverter Output Transformers

    by Ibrahim Sefa, Necmi Altin, Saban Ozdemir, Selami Balci, Funda Battal


  • Open Access

    IEEE 14 Bara Sistemine Bağlanabilecek Maksimum Yük Seviyelerinin Belirlenmesi

    by Uğur Fesli̇, Mustafa Bahadır ÖZDEMİR, Şaban Özdemi̇r

    Güç sistemlerindeki generatörler, enerji kaynaklarını verimli kullanmak için maksimum kapasitede çalıştırılır. Bu nedenle, güç sistemlerindeki dalgalanmalar rotor açısı, gerilim ve frekans açısından kararlılık sorunlarına neden olmaktadır. Özellikle yeni endüstriyel veya yerleşim alanlarının kurulması planlanırken güç sistemlerine yeni yükler eklenir. Bu çalışmada, sistemdeki yük değerleri değiştirilerek IEEE 14 bara sisteminin maksimum yük seviyesi belirlenmiştir. Maksimum yüklenme seviyesinin belirlenmesinde hat yüklenme seviyeleri, bara gerilimleri ve generatör yüklenme parametreleri kullanılmıştır. Sistem benzetimi DIgSILENT PowerFactory yazılımında yapılmıştır. Bir yükün değeri, hat yüklenme limitlerini aşıncaya kadar adım adım artırılmıştır. Yük değeri, DIgSILENT PowerFactory ile etkileşimli çalışan Python kod dizimi kullanılarak artırılmıştır. Benzer şekilde bara gerilimleri ve generatör yüklenmeleri için de aynı analizler tekrarlanmıştır. Maksimum yüklenme seviyesi, hat yüklenme seviyeleri, bara gerilimleri veya generatör yüklenmesinin maksimum sınırını aşan yük değerine bağlı olarak belirlenmiştir. Böylece, IEEE 14 bara sisteminin ulaşılabilecek maksimum yüklenme seviyeleri, gerilim kararlılığını etkileyen üç parametre dikkate alınarak elde edilmiştir. Simülasyon sonuçları, yüklenme için kısıtlayıcı parametrenin, güç sistemindeki yeni yüklerin yerine bağlı olduğunu göstermektedir.


  • Open Access

    Power System Reliability Assessment— A Review on Analysis and Evaluation Methods

    by Selahattin Gari̇p, Şaban Özdemi̇r, Necmi Altin

    The structures of power systems and their capacity have been updated significantly from time to time. Therefore, a reliability analysis is an essential issue in the planning, designing, and operation of electric power systems. Thus, a number of methods have been proposed. These are grouped as analytical based methods, simulation-based methods, and hybrid methods. Some methods like Monte Carlo, Markov etc., developed and some indices such as interruption indices, energy-oriented indices, are used for the evaluation. The purpose of this review study is to investigate the reliability analysis approaches, methods and difficulties, and to report importance of the reliability analysis in power systems. Therefore, reliability indices and evaluation methods and models of evaluation of power system are listed and explained. Besides, modeling and computational burden and complexity and problems are discussed. The importance of reliability analysis for emerging power systems is examined and explained.


  • Open Access

    Optimization of PV and Battery Energy Storage Size in Grid-Connected Microgrid

    by Selahattin Garip, Saban Ozdemir

    This paper proposes a new method to determine the optimal size of a photovoltaic (PV) and battery energy storage system (BESS) in a grid-connected microgrid (MG). Energy cost minimization is selected as an objective function. Optimum BESS and PV size are determined via a novel energy management method and particle swarm optimization (PSO) algorithm to obtain minimum total cost. The MG was designed to use its own energy as much as possible, which is produced from renewable energy resources. Since it is a grid-connected system, it can demand energy from the grid within the determined limit with penalty. It differs from the studies in the literature in terms of optimizing both parameters such as PV and BESS size, being a grid-connected self-contained MG structure and controlling the grid energy by an energy management algorithm and optimizing the parameter via PSO with an energy management system (EMS). Results are compared for different PV and BESS. Moreover, effectiveness of the novel energy management method with PSO is compared with the genetic algorithm, which is the one of the well-known optimization algorithms. The results show that the proposed algorithm can achieve optimum PV and BESS size with minimum cost by using the new energy management method with the PSO algorithm.


  • Super twisting sliding mode control of three-phase grid-tied neutral point clamped inverters

    by Saban Ozdemir, Necmi Altin, Ibrahim Sefa, Zhen Zhang, Hasan Komurcugil


  • A Novel Topology for Solar PV Inverter Based on an LLC Resonant Converter With Optimal Frequency and Phase-Shift Control

    by Necmi Altin, Saban Ozdemir, Mehdy Khayamy, Adel Nasiri

    In this article, a new topology for a grid-connected solar photovoltaic inverter for the direct connection to the medium-voltage grid is proposed. This topology employs an LLC resonant converter with a high-frequency (HF) isolation transformer in the dc–dc stage. The output of the dc–dc stage is a rectified sine wave voltage and current at the line frequency. An unfolder inverter interfaces between this dc stage and the grid. A combined phase-shift and frequency control method is used to control the LLC resonant converter. The phase-shift angle and switching frequency values of the LLC resonant converter are regulated to track the reference current signal for the whole operation range. The Lagrange multiplier method is applied to find the optimal trajectory to calculate the optimal phase-shift angle and switching frequency pairs for any operation condition by considering power converter and HF transformer losses to achieve the highest efficiency at a varying current. The transformer leakage and magnetization inductances are properly designed to provide a zero-voltage switching (ZVS) for a wide operation area, and additional resonant inductor requirement is removed. The LLC converter operates in a ZVS region except in a narrow band around the zero-current crossings of the inverter output. Using an HF transformer in the LLC resonant converter, a bulky line frequency transformer requirement is eliminated, and thus, a more compact and efficient design is obtained. The proposed topology is validated by the simulation and experimental results.


  • Open Access

    Development of a Medium Voltage, High Power, High Frequency Four-Port Solid State Transformer

    by Ahmad El Shafei, Saban Ozdemir, Necmi Altin, Garry Jean-Pierre, Adel Nasiri

    The power and voltage levels of renewable energy resources is growing with the evolution of the power electronics and switching module technologies. For that, the need for the development of a compact and highly efficient solid-state transformer is becoming a critical task in-order to integrate the current AC grid with the new renewable energy systems. The objective of this paper is to present the design, implementation, and testing of a compact multi-port solid-state transformer for microgrid integration applications. The proposed system has a four-port transformer and four converters connected to the ports. The transformer has four windings integrated on a single common core. Thus, it can integrate different renewable energy resources and energy storage systems. Each port has a rated power of 25kW, and the switching frequency is pushed to 50kHz. The ports are chosen to represent a realistic industrial microgrid model consisting of grid, energy storage system, photovoltaic system, and load. The grid port is designed to operate at 4.16kVAC corresponding to 7.2kV DC bus voltage, while the other three ports operate at 500VDC. Moreover, the grid, energy storage and photovoltaic ports are active ports with dual active bridge topologies, while the load port is a passive port with full bridge rectifier one. The proposed design is first validated with simulation results, and then the proposed transformer is implemented and tested. Experimental results show that the designed system is suitable for 4.16kVAC medium voltage grid integration.


  • Design and Implementation of a LLC Resonant Solid State Transformer

    by Mohammad Rashidi, Necmi Altin, Saban Ozdemir, Abedalsalam Bani-Ahmed, Mohammad Sabbah, Farhad Balali, Adel Nasiri

    In this study, analysis and control of a high efficient, high power full-bridge unidirectional resonant LLC solid state transformer is proposed. A combination of Pulse Frequency Modulation (PFM) and Phase Shift Modulation (PSM) methods is utilized to control this resonant converter for wide load range. The converter is designed to maintain soft switching by using a resonant circuit to minimize the switching loss of the high frequency converter. Zero-voltage-switching (ZVS) is achieved for the H-bridge converter. The ZVS boundary for the proposed combined control method is also analyzed in detail. The experimental setup for the suggested configuration was implemented, and the performance of the proposed control scheme and resonant LLC solid state transformer have been verified with test results. The proposed combined control scheme improves the control performance. The obtained results show that, proposed system can regulate the output voltage and maintain the soft switching in a wide-load range. Thus, the efficiency of the system is improved and 97.18% efficiency is achieved.