Maciej Wysocki
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Maciej Wysocki has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Dan Zenkert
KTH Royal Institute of Technology
2 shared publications Erik Adolfsson
2 shared publicationsHenrik Dykhoff
2 shared publicationsJanis Varna
Department of Engineering Sciences and Mathematics, Luleå Tekniska Universitet, Luleå 971 87, Sweden
2 shared publicationsJocke Pettersson
2 shared publicationsRakel Wreland Lindström
2 shared publications
Latest Publications
- Open Access
- 3 April 2024
- Published by Elsevier in Composites Science and Technology
- Vol. 251
Enhancing structural battery performance: Investigating the role of conductive carbon additives in LiFePO4-Impregnated carbon fiber electrodes
- 3 April 2024
- Published by Elsevier in Composites Science and Technology
- Vol. 251
Open AccessEnhancing structural battery performance: Investigating the role of conductive carbon additives in LiFePO4-Impregnated carbon fiber electrodes
- Open Access
- 8 July 2023
- Published by Elsevier in Composites Science and Technology
- Vol. 241
Powder-impregnated carbon fibers with lithium iron phosphate as positive electrodes in structural batteries
- 8 July 2023
- Published by Elsevier in Composites Science and Technology
- Vol. 241
Open AccessPowder-impregnated carbon fibers with lithium iron phosphate as positive electrodes in structural batteries
- 1 May 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Research of magnetic system applied in autonomous MegaSumo robots
Research of magnetic system applied in autonomous MegaSumo robots is an important issue in the best adaptation of a fighting robot. Only this type of robots (dimensions 200×200 mm, weight up to 3000g) are obliged to use it. It is caused by the driving of robots on the metal rings (dohyo). To get the best movement characteristics, magnets are attached to the robot's floor. The quantity of magnets results in high or low traction during the fight. High magnetising power does not allow the opponent to get under the robot and push it out of the ring. In the article, simulation research was carried out on three different magnetic systems that can be used in a robot. After the simulations, each system was built in reality. In order to check the actual attractive forces of the system, tests were carried out on the strength machine. This allowed comparing the results from simulations and real tests. The best layout was used in the sumo robot. It had the greatest strength of attraction for a metal dohyo.
- 1 May 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Research of magnetic system applied in autonomous MegaSumo robots
Research of magnetic system applied in autonomous MegaSumo robots is an important issue in the best adaptation of a fighting robot. Only this type of robots (dimensions 200×200 mm, weight up to 3000g) are obliged to use it. It is caused by the driving of robots on the metal rings (dohyo). To get the best movement characteristics, magnets are attached to the robot's floor. The quantity of magnets results in high or low traction during the fight. High magnetising power does not allow the opponent to get under the robot and push it out of the ring. In the article, simulation research was carried out on three different magnetic systems that can be used in a robot. After the simulations, each system was built in reality. In order to check the actual attractive forces of the system, tests were carried out on the strength machine. This allowed comparing the results from simulations and real tests. The best layout was used in the sumo robot. It had the greatest strength of attraction for a metal dohyo.
- Open Access
- 3 July 2017
- Published by Taylor & Francis in Advanced Manufacturing: Polymer & Composites Science
- Vol. 3 (3) , 92-100
Cure-state dependent viscoelastic Poisson’s ratio of LY5052 epoxy resin
It is shown, using thermodynamically consistent linear viscoelastic material model that accounts for properties dependence on test temperature and cure state parameters, that for rheologically simple materials the cure and temperature related reduced times and shift factors are the same for all viscoelastic compliances, relaxation modulus, and Poisson’s ratio as well as for the storage and loss modulus. A necessary condition for that is that the cure and temperature parameters are affecting the reduced time only. This means that the Poisson’s ratio of polymeric materials, which for simplicity is often assumed constant, in fact exhibits a small dependence on time which is affected by temperature and state of cure. In this work, the evolution of the viscoelastic Poisson’s ratio of the commercial LY5052 epoxy resin is studied in relaxation test subjecting the specimen to constant axial strain. Specimens at several cure states are studied and Poisson’s ratio, defined as the lateral and axial strain ratio, is shown to evolve from 0.32 to 0.44 over time. Moreover, the data confirm that the cure state-dependent reduced time controlling the Poisson’s ratio development leads to the same shift functions as those identified in DMTA tests for storage modulus. The latter measurements also confirmed that the total shift can be considered as a sum of two shifts in the frequency domain, which means that function for reduced time calculation can be written as a product of two functions: one dependent on the test temperature and another one dependent on the cure state.
- 3 July 2017
- Published by Taylor & Francis in Advanced Manufacturing: Polymer & Composites Science
- Vol. 3 (3) , 92-100
Open AccessCure-state dependent viscoelastic Poisson’s ratio of LY5052 epoxy resin
It is shown, using thermodynamically consistent linear viscoelastic material model that accounts for properties dependence on test temperature and cure state parameters, that for rheologically simple materials the cure and temperature related reduced times and shift factors are the same for all viscoelastic compliances, relaxation modulus, and Poisson’s ratio as well as for the storage and loss modulus. A necessary condition for that is that the cure and temperature parameters are affecting the reduced time only. This means that the Poisson’s ratio of polymeric materials, which for simplicity is often assumed constant, in fact exhibits a small dependence on time which is affected by temperature and state of cure. In this work, the evolution of the viscoelastic Poisson’s ratio of the commercial LY5052 epoxy resin is studied in relaxation test subjecting the specimen to constant axial strain. Specimens at several cure states are studied and Poisson’s ratio, defined as the lateral and axial strain ratio, is shown to evolve from 0.32 to 0.44 over time. Moreover, the data confirm that the cure state-dependent reduced time controlling the Poisson’s ratio development leads to the same shift functions as those identified in DMTA tests for storage modulus. The latter measurements also confirmed that the total shift can be considered as a sum of two shifts in the frequency domain, which means that function for reduced time calculation can be written as a product of two functions: one dependent on the test temperature and another one dependent on the cure state.
- 10 April 2017
- Published by Taylor & Francis in Advanced Composite Materials
- Vol. 26 (6) , 553-567
Evolution of viscoelastic behaviour of a curing LY5052 epoxy resin in the rubbery state
In this work, we investigate the relationship between the rubbery modulus and the degree of cure for partially to fully cured LY5052 epoxy resin. In particular, this paper experimentally tests an existing model formulated for shear modulus by redefining for in the tensile storage modulus. Experiments to characterize viscoelastic behaviour were performed in a dynamic mechanical and thermal analysis (DMTA) instrument in the frequency domain. Master curves are then created from DMTA using general time–temperature–cure superposition. The master curves are then normalized using the model so that the master curve does not depend on the properties in the rubbery region. This results in a unique master curve that describes the viscoelastic behaviour of the LY5052 epoxy resin for the given conditions. Once the relationship between the rubbery modulus and the degree of cure has been established, the amount of experimental characterization can be reduced. This could lead to the development of simplified experimental methodologies and simplified models to characterize the viscoelasticity of low molecular weight resins like the LY5052 epoxy resin system.
- 10 April 2017
- Published by Taylor & Francis in Advanced Composite Materials
- Vol. 26 (6) , 553-567
Evolution of viscoelastic behaviour of a curing LY5052 epoxy resin in the rubbery state
In this work, we investigate the relationship between the rubbery modulus and the degree of cure for partially to fully cured LY5052 epoxy resin. In particular, this paper experimentally tests an existing model formulated for shear modulus by redefining for in the tensile storage modulus. Experiments to characterize viscoelastic behaviour were performed in a dynamic mechanical and thermal analysis (DMTA) instrument in the frequency domain. Master curves are then created from DMTA using general time–temperature–cure superposition. The master curves are then normalized using the model so that the master curve does not depend on the properties in the rubbery region. This results in a unique master curve that describes the viscoelastic behaviour of the LY5052 epoxy resin for the given conditions. Once the relationship between the rubbery modulus and the degree of cure has been established, the amount of experimental characterization can be reduced. This could lead to the development of simplified experimental methodologies and simplified models to characterize the viscoelasticity of low molecular weight resins like the LY5052 epoxy resin system.