Jean Baptiste Mosset
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Jean Baptiste Mosset has a total of 146 co-authors. Here are the top co-authors by number of shared publications:
C. Morel
11 shared publicationsJ.-F. Loude
8 shared publicationsM. Krieguer
8 shared publicationsM. Rey
7 shared publicationsO. Devroede
7 shared publicationsP. Bruyndonckx
7 shared publications
Latest Publications
- 2 March 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 67 (4) , 625-635
A mm3 Fiber-Coupled Scintillator for In-Core Thermal Neutron Detection in CROCUS
- 2 March 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 67 (4) , 625-635
A mm3 Fiber-Coupled Scintillator for In-Core Thermal Neutron Detection in CROCUS
- 23 January 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 65 (8) , 2061-2067
Evaluation of ZnS:6LiF and ZnO:6LiF Scintillation Neutron Detectors Readout With SiPMs
It is generally accepted that the count rate capability of ZnS: 6 LiF neutron detectors is strongly limited due to the long afterglow of the scintillator. However, realized as an array of individual sensitive elements (pixels) with independent signal readout and processing, such detectors can be operated with blocking times down to 1 μs and promising counting rates up to 100 kHz/pixel. In this paper, we investigate how the long emission of the ZnS scintillator influences the detector performance apart from requiring a finite blocking time to suppress the probability of multiple counts. We also study the potential of the ZnO: 6 LiF scintillator with lower afterglow as a possible replacement of ZnS: 6 LiF.
- 23 January 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 65 (8) , 2061-2067
Evaluation of ZnS:6LiF and ZnO:6LiF Scintillation Neutron Detectors Readout With SiPMs
It is generally accepted that the count rate capability of ZnS: 6 LiF neutron detectors is strongly limited due to the long afterglow of the scintillator. However, realized as an array of individual sensitive elements (pixels) with independent signal readout and processing, such detectors can be operated with blocking times down to 1 μs and promising counting rates up to 100 kHz/pixel. In this paper, we investigate how the long emission of the ZnS scintillator influences the detector performance apart from requiring a finite blocking time to suppress the probability of multiple counts. We also study the potential of the ZnO: 6 LiF scintillator with lower afterglow as a possible replacement of ZnS: 6 LiF.
- Open Access
A 16-ch module for thermal neutron detection using ZnS:${}^6$LiF scintillator with embedded WLS fibers coupled to SiPMs and its dedicated readout electronics
A scalable 16-ch thermal neutron detection system has been developed in the framework of the upgrade of a neutron diffractometer. The detector is based on ZnS:${}^6$LiF scintillator with embedded WLS fibers which are read out with SiPMs. In this paper, we present the 16-ch module, the dedicated readout electronics, a direct comparison between the performance of the diffractometer obtained with the current ${}^3$He detector and with the 16-ch detection module, and the channel-to-channel uniformity.
Open AccessA 16-ch module for thermal neutron detection using ZnS:${}^6$LiF scintillator with embedded WLS fibers coupled to SiPMs and its dedicated readout electronics
A scalable 16-ch thermal neutron detection system has been developed in the framework of the upgrade of a neutron diffractometer. The detector is based on ZnS:${}^6$LiF scintillator with embedded WLS fibers which are read out with SiPMs. In this paper, we present the 16-ch module, the dedicated readout electronics, a direct comparison between the performance of the diffractometer obtained with the current ${}^3$He detector and with the 16-ch detection module, and the channel-to-channel uniformity.
- 21 November 2015
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 824, 319-321
Digital signal processing for a thermal neutron detector using ZnS(Ag):6LiF scintillating layers read out with WLS fibers and SiPMs
- 21 November 2015
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 824, 319-321
Digital signal processing for a thermal neutron detector using ZnS(Ag):6LiF scintillating layers read out with WLS fibers and SiPMs
- Open Access
Digital signal processing for a thermal neutron detector using ZnS(Ag):6LiF scintillating layers read out with WLS fibers and SiPMs
We present a digital signal processing system based on a photon counting approach which we developed for a thermal neutron detector consisting of ZnS(Ag):6LiF scintillating layers read out with WLS fibers and SiPMs. Three digital filters have been evaluated: a moving sum, a moving sum after differentiation and a digital CR-RC^4 filter. The performances of the detector with these filters are presented. A full analog signal processing using a CR-RC^4 filter has been emulated digitally. The detector performance obtained with this analog approach is compared with the one obtained with the best performing digital approach.
Open AccessDigital signal processing for a thermal neutron detector using ZnS(Ag):6LiF scintillating layers read out with WLS fibers and SiPMs
We present a digital signal processing system based on a photon counting approach which we developed for a thermal neutron detector consisting of ZnS(Ag):6LiF scintillating layers read out with WLS fibers and SiPMs. Three digital filters have been evaluated: a moving sum, a moving sum after differentiation and a digital CR-RC^4 filter. The performances of the detector with these filters are presented. A full analog signal processing using a CR-RC^4 filter has been emulated digitally. The detector performance obtained with this analog approach is compared with the one obtained with the best performing digital approach.
- 1 November 2014
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 764, 299-304
Evaluation of two thermal neutron detection units consisting of ZnS/ 6 LiF scintillating layers with embedded WLS fibers read out with a SiPM
- 1 November 2014
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 764, 299-304
Evaluation of two thermal neutron detection units consisting of ZnS/ 6 LiF scintillating layers with embedded WLS fibers read out with a SiPM
- Open Access
- 24 July 2014
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 528 (1) , 012041
Upgrade of the POLDI diffractometer with a ZnS(Ag)/6LiF scintillation detector read out with WLS fibers coupled to SiPMs
A thermal neutron detector based on ZnS(Ag)/6LiF scintillator, wavelength- shifting fibers (WLS) and silicon photomultipliers (SiPM) is under development at the Paul Scherrer Institute (PSI) for upgrading the POLDI instrument, a pulse-overlap diffractometer. The design of the detector is outlined, and the measurements performed on a single channel prototype are presented. An innovative signal processing system based on a photon counting approach is under development. Its principle of operation is described and its performances are evaluated on the basis of a Monte Carlo simulation.
- 24 July 2014
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 528 (1) , 012041
Open AccessUpgrade of the POLDI diffractometer with a ZnS(Ag)/6LiF scintillation detector read out with WLS fibers coupled to SiPMs
A thermal neutron detector based on ZnS(Ag)/6LiF scintillator, wavelength- shifting fibers (WLS) and silicon photomultipliers (SiPM) is under development at the Paul Scherrer Institute (PSI) for upgrading the POLDI instrument, a pulse-overlap diffractometer. The design of the detector is outlined, and the measurements performed on a single channel prototype are presented. An innovative signal processing system based on a photon counting approach is under development. Its principle of operation is described and its performances are evaluated on the basis of a Monte Carlo simulation.
- 1 June 2014
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 9 (06) , P06015
Use of Silicon Photomultipliers in ZnS:6LiF scintillation neutron detectors: signal extraction in presence of high dark count rates
- 1 June 2014
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 9 (06) , P06015
Use of Silicon Photomultipliers in ZnS:6LiF scintillation neutron detectors: signal extraction in presence of high dark count rates
- Open Access
Upgrade of the POLDI diffractometer with a ZnS(Ag)/6LiF scintillation detector read out with WLS fibers coupled to SiPMs
A thermal neutron detector based on ZnS(Ag)/6LiF scintillator, wavelength-shifting fibers (WLS) and silicon photomultipliers (SiPM) is under development at the Paul Scherrer Institute (PSI) for upgrading the POLDI instrument, a pulse-overlap diffractometer. The design of the detector is outlined, and the measurements performed on a single channel prototype are presented. An innovative signal processing system based on a photon counting approach is under development. Its principle of operation is described and its performances are evaluated on the basis of a Monte Carlo simulation.
Open AccessUpgrade of the POLDI diffractometer with a ZnS(Ag)/6LiF scintillation detector read out with WLS fibers coupled to SiPMs
A thermal neutron detector based on ZnS(Ag)/6LiF scintillator, wavelength-shifting fibers (WLS) and silicon photomultipliers (SiPM) is under development at the Paul Scherrer Institute (PSI) for upgrading the POLDI instrument, a pulse-overlap diffractometer. The design of the detector is outlined, and the measurements performed on a single channel prototype are presented. An innovative signal processing system based on a photon counting approach is under development. Its principle of operation is described and its performances are evaluated on the basis of a Monte Carlo simulation.