Gustavo Avolio
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Gustavo Avolio has a total of 89 co-authors. Here are the top co-authors by number of shared publications:
- Dominique Schreurs
KU Leuven
70 shared publications - Antonio Raffo
University of Ferrara
43 shared publications - Giorgio Vannini
University of Ferrara
41 shared publications - Giovanni Crupi
University of Messina
30 shared publications - Alina Caddemi
Department of Engineering, University of Messina, 98166 Messina, Italy
22 shared publications - Bart Nauwelaers
Department of Electrical Engineering (ESAT), KU Leuven, Leuven, Belgium
14 shared publications
Latest Publications
- 18 June 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Microwave Theory and Techniques
- Vol. 68 (8) , 3532-3546
Uncertainty in Large-Signal Measurements Under Variable Load Conditions
We investigate the uncertainty of large-signal measurements of a microwave transistor due to variation in the load conditions at the fundamental frequency. In particular, we evaluate uncertainties in the complex frequency-domain traveling voltage waves. In our analysis, uncertainty sources typical for large-signal measurements are considered. Then, we discuss how the resultant uncertainty in the waves is dependent on a varying load reflection coefficient. For this investigation, we consider the total uncertainty of the waves and their magnitude and phase. We also show that these errors unavoidably affect the uncertainty of performance quantities, such as output power.
- 18 June 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Microwave Theory and Techniques
- Vol. 68 (8) , 3532-3546
Uncertainty in Large-Signal Measurements Under Variable Load Conditions
We investigate the uncertainty of large-signal measurements of a microwave transistor due to variation in the load conditions at the fundamental frequency. In particular, we evaluate uncertainties in the complex frequency-domain traveling voltage waves. In our analysis, uncertainty sources typical for large-signal measurements are considered. Then, we discuss how the resultant uncertainty in the waves is dependent on a varying load reflection coefficient. For this investigation, we consider the total uncertainty of the waves and their magnitude and phase. We also show that these errors unavoidably affect the uncertainty of performance quantities, such as output power.
- Open Access
- 18 September 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Microwave and Wireless Components Letters
- Vol. 28 (11) , 1035-1037
Assessing GaN FET Performance Degradation in Power Amplifiers for Pulsed Radar Systems
GaN FETs have achieved superior performance in the design of microwave power circuits. Nevertheless, the amount of dispersion related to this technology poses severe issues for the correct modeling and characterization of these devices. In this letter, the effects of GaN FET dispersion on the design of power amplifiers (PAs) with dynamic power supply, largely adopted in state-of-the-art high-efficiency pulsed radar transmitters, are discussed. In particular, we propose a technique for evaluating GaN device performance degradation in new-generation PAs that represents an effective alternative to pulsed-RF multiharmonic source/load-pull microwave setups.
- 18 September 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Microwave and Wireless Components Letters
- Vol. 28 (11) , 1035-1037
Open AccessAssessing GaN FET Performance Degradation in Power Amplifiers for Pulsed Radar Systems
GaN FETs have achieved superior performance in the design of microwave power circuits. Nevertheless, the amount of dispersion related to this technology poses severe issues for the correct modeling and characterization of these devices. In this letter, the effects of GaN FET dispersion on the design of power amplifiers (PAs) with dynamic power supply, largely adopted in state-of-the-art high-efficiency pulsed radar transmitters, are discussed. In particular, we propose a technique for evaluating GaN device performance degradation in new-generation PAs that represents an effective alternative to pulsed-RF multiharmonic source/load-pull microwave setups.
- Open Access
- 1 November 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Microwave Theory and Techniques
- Vol. 66 (2) , 1121-1130
Design and Evaluation of Nonlinear Verification Device for Nonlinear Vector Network Analyzers
A simple diode-based nonlinear verification device (NVD) design for nonlinear vector network analyzers is presented together with an improved figure of merit (FOM) parameter that is insensitive to impedance match and isolates variation of the devicequoteright s nonlinear parameters. The stability over 84 h and load-pull performance of this new design have been evaluated.
- 1 November 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Microwave Theory and Techniques
- Vol. 66 (2) , 1121-1130
Open AccessDesign and Evaluation of Nonlinear Verification Device for Nonlinear Vector Network Analyzers
A simple diode-based nonlinear verification device (NVD) design for nonlinear vector network analyzers is presented together with an improved figure of merit (FOM) parameter that is insensitive to impedance match and isolates variation of the devicequoteright s nonlinear parameters. The stability over 84 h and load-pull performance of this new design have been evaluated.
- 1 October 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 162-165
Thermal characterization of high-power GaN HEMTs up to 65 GHz
This study focuses on temperature dependent characterization of a 0.25×1500 μm 2 GaN HEMT. The impact of the ambient temperature on the microwave performance is reported and discussed. It is achieved that the reduction of the average electron velocity with increasing temperature leads to a remarkably degradation of the main figures of merit.
- 1 October 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 162-165
Thermal characterization of high-power GaN HEMTs up to 65 GHz
This study focuses on temperature dependent characterization of a 0.25×1500 μm 2 GaN HEMT. The impact of the ambient temperature on the microwave performance is reported and discussed. It is achieved that the reduction of the average electron velocity with increasing temperature leads to a remarkably degradation of the main figures of merit.
- 1 May 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Impact of transistor model uncertainty on microwave load-pull simulations
We propagate the uncertainty of measurements used for the identification of a transistor nonlinear model to microwave load-pull simulations. The results are presented for a 0.15-μm GaAs pHEMT under class-AB regime at different frequencies of operation.
- 1 May 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Impact of transistor model uncertainty on microwave load-pull simulations
We propagate the uncertainty of measurements used for the identification of a transistor nonlinear model to microwave load-pull simulations. The results are presented for a 0.15-μm GaAs pHEMT under class-AB regime at different frequencies of operation.
- 8 December 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Microwave Theory and Techniques
- Vol. 65 (1) , 218-228
A New Dynamic-Bias Measurement Setup for Nonlinear Transistor Model Identification
In this paper, we present a new dynamic-bias measurement setup and its application to the extraction of a nonlinear model for microwave field-effect transistors. The dynamic-bias technique has been recently proposed and relies on the use of low-frequency (LF) and high-frequency (HF) vector-calibrated measurements acquired, for instance, by means of a large-signal network analyzer. In this paper, we propose a new and alternative technique to perform the dynamic-bias measurements, based on relatively low-cost instrumentation commonly available in microwave laboratories. The new acquisition system is composed of a four-channel vector LF receiver (e.g., an oscilloscope) and a one-channel HF scalar receiver (e.g., a spectrum analyzer), which replace the eight-channel vector receiver. Moreover, the proposed architecture greatly simplifies the measurement setup and the calibration procedure. As a case study, a 0.25-μm GaN HEMT is considered. Dynamic-bias measurements, carried out by means of the proposed measurement setup, are used for the identification of a nonlinear model of this device. Finally, the model is fully validated through comparison with time-domain harmonic load-pull measurements carried out at 5 GHz.
- 8 December 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Microwave Theory and Techniques
- Vol. 65 (1) , 218-228
A New Dynamic-Bias Measurement Setup for Nonlinear Transistor Model Identification
In this paper, we present a new dynamic-bias measurement setup and its application to the extraction of a nonlinear model for microwave field-effect transistors. The dynamic-bias technique has been recently proposed and relies on the use of low-frequency (LF) and high-frequency (HF) vector-calibrated measurements acquired, for instance, by means of a large-signal network analyzer. In this paper, we propose a new and alternative technique to perform the dynamic-bias measurements, based on relatively low-cost instrumentation commonly available in microwave laboratories. The new acquisition system is composed of a four-channel vector LF receiver (e.g., an oscilloscope) and a one-channel HF scalar receiver (e.g., a spectrum analyzer), which replace the eight-channel vector receiver. Moreover, the proposed architecture greatly simplifies the measurement setup and the calibration procedure. As a case study, a 0.25-μm GaN HEMT is considered. Dynamic-bias measurements, carried out by means of the proposed measurement setup, are used for the identification of a nonlinear model of this device. Finally, the model is fully validated through comparison with time-domain harmonic load-pull measurements carried out at 5 GHz.
- 28 September 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Microwave Theory and Techniques
- Vol. 64 (11) , 3946-3955
Dynamic-Bias S-Parameters: A New Measurement Technique for Microwave Transistors
We present the first application of the recently introduced dynamic-bias measurement to the acquisition of the scattering (S-) parameters of microwave transistors under large signal operating conditions. We demonstrate that by properly acquiring and processing dynamic-bias measurements, one can derive the S-parameters of a nonlinear device-under test across a time-varying large-signal operating point (LSOP). Interestingly, these time-varying S-parameters can be used similar to the conventional S-parameters for characterization and modeling purposes. As compared with similar existing approaches, like those based on the pulsed S-parameter measurements, with the proposed technique, one can obtain, as a result of one measurement, the frequency-dependent S-parameters at each instantaneous point touched by the LSOP. We report experimental dynamic-bias S-parameters of a 0.15-μm GaAs pHEMT and a 0.25-μm GaN HEMT.
- 28 September 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Microwave Theory and Techniques
- Vol. 64 (11) , 3946-3955
Dynamic-Bias S-Parameters: A New Measurement Technique for Microwave Transistors
We present the first application of the recently introduced dynamic-bias measurement to the acquisition of the scattering (S-) parameters of microwave transistors under large signal operating conditions. We demonstrate that by properly acquiring and processing dynamic-bias measurements, one can derive the S-parameters of a nonlinear device-under test across a time-varying large-signal operating point (LSOP). Interestingly, these time-varying S-parameters can be used similar to the conventional S-parameters for characterization and modeling purposes. As compared with similar existing approaches, like those based on the pulsed S-parameter measurements, with the proposed technique, one can obtain, as a result of one measurement, the frequency-dependent S-parameters at each instantaneous point touched by the LSOP. We report experimental dynamic-bias S-parameters of a 0.15-μm GaAs pHEMT and a 0.25-μm GaN HEMT.
- 1 May 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Supply-terminal 40 MHz BW characterization of impedance-like nonlinear functions for envelope tracking PAs
We present an approach for the dynamic characterization of the non-idealities arising in envelope tracking (ET) systems when either the radio-frequency (RF) power amplifier (PA) or the supply modulator (SM) are driven into nonlinear operation. Impedance-like nonlinear functions, derived through a modified Volterra formulation, are here introduced and measured at the supply terminal over 40 MHz bandwidth (BW), allowing better predictions of the dynamic voltage and current at the SM-PA interface.
- 1 May 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Supply-terminal 40 MHz BW characterization of impedance-like nonlinear functions for envelope tracking PAs
We present an approach for the dynamic characterization of the non-idealities arising in envelope tracking (ET) systems when either the radio-frequency (RF) power amplifier (PA) or the supply modulator (SM) are driven into nonlinear operation. Impedance-like nonlinear functions, derived through a modified Volterra formulation, are here introduced and measured at the supply terminal over 40 MHz bandwidth (BW), allowing better predictions of the dynamic voltage and current at the SM-PA interface.
- 1 May 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Impact of microwave measurement uncertainty on the Nonlinear Embedding procedure
We analyze the uncertainty contribution of the Nonlinear-Embedding design technique in transposing the low-frequency data to microwave frequencies. Uncertainty analysis is performed with the NIST Microwave Uncertainty Framework and is applied to a GaAs pHEMT device.
- 1 May 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Impact of microwave measurement uncertainty on the Nonlinear Embedding procedure
We analyze the uncertainty contribution of the Nonlinear-Embedding design technique in transposing the low-frequency data to microwave frequencies. Uncertainty analysis is performed with the NIST Microwave Uncertainty Framework and is applied to a GaAs pHEMT device.
- 1 May 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Large signal rectifier characterization for simultaneous data and Power Transfer
In this work we characterize the RF-to-baseband response of a diode used for a rectifier circuit. The measurement setup enables the synchronous acquisition of vector-calibrated baseband and RF time-domain waveforms. The behavior of a Schottky diode, widely employed for RF Energy Harvesting and Wireless Power Transfer applications, is first measured, then further optimized, in order to enable the level of accuracy needed for the correct decoding of a possible modulated input RF signal. Finally, the RF to baseband response is further validated with a single-stage rectifier, in a different measurement setup.
- 1 May 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Large signal rectifier characterization for simultaneous data and Power Transfer
In this work we characterize the RF-to-baseband response of a diode used for a rectifier circuit. The measurement setup enables the synchronous acquisition of vector-calibrated baseband and RF time-domain waveforms. The behavior of a Schottky diode, widely employed for RF Energy Harvesting and Wireless Power Transfer applications, is first measured, then further optimized, in order to enable the level of accuracy needed for the correct decoding of a possible modulated input RF signal. Finally, the RF to baseband response is further validated with a single-stage rectifier, in a different measurement setup.