Fujio Kurokawa
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Fujio Kurokawa has a total of 71 co-authors. Here are the top co-authors by number of shared publications:
- Hiroaki Kusawake
Japan Aerospace Exploration Agency, Tsukuba, Japan
4 shared publications - Hiroki Watanabe
Japan Aerospace Exploration Agency
4 shared publications - Ikkoh Funaki
Japan Aerospace Exploration Agency, Sagamihara, Japan
4 shared publications - Jizhe Wang
Institute for Innovative Science and Technology, Nagasaki Institute of Applied Science, Nagasaki, Japan
4 shared publications - Kazuhiro Kajiwara
Nagasaki Institute of Applied Science, Nagasaki, Japan
4 shared publications - Shinatora Cho
Japan Aerospace Exploration Agency
4 shared publications
Latest Publications
- 17 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 62 (4) , 5635-5645
Multi-Vehicle Optimization for Coordinating Electric Vehicle Power Supply and Charging
Medical facilities providing dialysis treatment need to strengthen their power grid resilience against blackouts to ensure continued medical services. In Japan, the number of artificial dialysis patients is increasing, and natural disasters cause blackouts annually. Then, reinforcing power grid resilience has become a critical issue for medical facilities. Typically, most of these facilities install emergency generators that are designed to only supply power to essential equipment. As a result, load suppression must be implemented, limiting their ability to provide medical services during blackouts. To address this issue, a power supply system combining a diesel generator (DG) and electric vehicles (EVs) is being considered. By optimizing the power supply from the DG and EVs, as well as coordinating EV charging, this system is anticipated to supply power to a medical facility for a longer duration without load suppression. Therefore, this paper proposes an optimization method for multiple vehicles, coordinating EV power supply and charging. The results indicate that the proposed optimization method can supply stable power to the medical facility, even under natural disasters where additional fuel cannot be supplied to the DG fuel tank, providing power for over 72 h in summer and 48 h in winter without load suppression. In Japan, there are more than 4,500 dialysis facilities, and their aggregated power demand is comparable to that of a large-scale power plant. Accordingly, the proposed operation method has substantial significance in terms of both practical feasibility and societal impact. In addition, business buildings are legally required to install emergency power generation systems. The proposed approach can contribute not only to medical facilities but also to enhancing power resilience in business buildings that utilize EVs for commercial operations or goods transportation
- 17 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 62 (4) , 5635-5645
Multi-Vehicle Optimization for Coordinating Electric Vehicle Power Supply and Charging
Medical facilities providing dialysis treatment need to strengthen their power grid resilience against blackouts to ensure continued medical services. In Japan, the number of artificial dialysis patients is increasing, and natural disasters cause blackouts annually. Then, reinforcing power grid resilience has become a critical issue for medical facilities. Typically, most of these facilities install emergency generators that are designed to only supply power to essential equipment. As a result, load suppression must be implemented, limiting their ability to provide medical services during blackouts. To address this issue, a power supply system combining a diesel generator (DG) and electric vehicles (EVs) is being considered. By optimizing the power supply from the DG and EVs, as well as coordinating EV charging, this system is anticipated to supply power to a medical facility for a longer duration without load suppression. Therefore, this paper proposes an optimization method for multiple vehicles, coordinating EV power supply and charging. The results indicate that the proposed optimization method can supply stable power to the medical facility, even under natural disasters where additional fuel cannot be supplied to the DG fuel tank, providing power for over 72 h in summer and 48 h in winter without load suppression. In Japan, there are more than 4,500 dialysis facilities, and their aggregated power demand is comparable to that of a large-scale power plant. Accordingly, the proposed operation method has substantial significance in terms of both practical feasibility and societal impact. In addition, business buildings are legally required to install emergency power generation systems. The proposed approach can contribute not only to medical facilities but also to enhancing power resilience in business buildings that utilize EVs for commercial operations or goods transportation
- Open Access
- 26 June 2025
- Published by Springer Nature in Journal of Electric Propulsion
- Vol. 4 (1) , 1-18
Discharge current amplitude detection in power processing units for hall thrusters
Discharge current oscillation in Hall thrusters can cause noise or, in the worst case, severe damage to the satellite. An amplitude detection system senses the discharge current and can shut off the thruster if excessive oscillations occur. The system divides a waveform 100 ms long and sampled at 1 MHz into 1000 segments and calculates the current amplitude in each segment. Next, a Power Processing Unit (PPU) calculates the number of segments where the current threshold is exceeded and determines whether the thruster should stop running. The proposed system was installed in a PPU2, PPU for 6 kW thrusters, and PPU Technology Development Unit 2 (PPU-TDU2) for 1 kW thrusters. In a test of the PPU2, the system detected 905 peaks over the threshold of 5.1 A during the 100 ms period, which has acceptable agreement with the actual number of peaks, 931. In addition, the thruster can be automatically changed to a state with a low-amplitude discharge current by changing the magnetic field. In a test of the PPU-TDU2, the maximum amplitude of 4.3 A calculated by the system agreed well with the peak value of 4.07 A calculated from the current waveform on an oscilloscope. These results reveal that the amplitude detection system is sufficiently accurate for thrusters of different power levels.
- 26 June 2025
- Published by Springer Nature in Journal of Electric Propulsion
- Vol. 4 (1) , 1-18
Open AccessDischarge current amplitude detection in power processing units for hall thrusters
Discharge current oscillation in Hall thrusters can cause noise or, in the worst case, severe damage to the satellite. An amplitude detection system senses the discharge current and can shut off the thruster if excessive oscillations occur. The system divides a waveform 100 ms long and sampled at 1 MHz into 1000 segments and calculates the current amplitude in each segment. Next, a Power Processing Unit (PPU) calculates the number of segments where the current threshold is exceeded and determines whether the thruster should stop running. The proposed system was installed in a PPU2, PPU for 6 kW thrusters, and PPU Technology Development Unit 2 (PPU-TDU2) for 1 kW thrusters. In a test of the PPU2, the system detected 905 peaks over the threshold of 5.1 A during the 100 ms period, which has acceptable agreement with the actual number of peaks, 931. In addition, the thruster can be automatically changed to a state with a low-amplitude discharge current by changing the magnetic field. In a test of the PPU-TDU2, the maximum amplitude of 4.3 A calculated by the system agreed well with the peak value of 4.07 A calculated from the current waveform on an oscilloscope. These results reveal that the amplitude detection system is sufficiently accurate for thrusters of different power levels.
- Open Access
- 4 April 2025
- Published by Springer Nature in Research Square
Discharge Current Amplitude Detection in Power Processing Units for Hall Thrusters
Discharge current oscillation in Hall thrusters can cause noise or, in the worst case, severe damage to the satellite. An amplitude detection system senses the discharge current and can shut off the thruster if excessive oscillations occur. The system divides a waveform 100 ms long and sampled at 1 MHz into 1000 segments and calculates the current amplitude in each segment. Next, a Power Processing Unit (PPU) calculates the number of segments where the current threshold is exceeded and determines whether the thruster should stop running. The proposed system was installed in a PPU2, PPU for 6 kW thrusters, and PPU Technology Development Unit 2 (PPU-TDU2) for 1 kW thrusters. In a test of the PPU2, the system detected 905 peaks over the threshold of 5.1 A during the 100 ms period, which agrees with the actual number of peaks, 931. In addition, the thruster can be automatically changed to a state with a low-amplitude discharge current by changing the magnetic field. In a test of the PPU-TDU2, the maximum amplitude of 4.3 A calculated by the system agreed well with the peak value of 4.07 A calculated from the current waveform on an oscilloscope. These results reveal that the amplitude detection system is sufficiently accurate for thrusters of different power levels.
- 4 April 2025
- Published by Springer Nature in Research Square
Open AccessDischarge Current Amplitude Detection in Power Processing Units for Hall Thrusters
Discharge current oscillation in Hall thrusters can cause noise or, in the worst case, severe damage to the satellite. An amplitude detection system senses the discharge current and can shut off the thruster if excessive oscillations occur. The system divides a waveform 100 ms long and sampled at 1 MHz into 1000 segments and calculates the current amplitude in each segment. Next, a Power Processing Unit (PPU) calculates the number of segments where the current threshold is exceeded and determines whether the thruster should stop running. The proposed system was installed in a PPU2, PPU for 6 kW thrusters, and PPU Technology Development Unit 2 (PPU-TDU2) for 1 kW thrusters. In a test of the PPU2, the system detected 905 peaks over the threshold of 5.1 A during the 100 ms period, which agrees with the actual number of peaks, 931. In addition, the thruster can be automatically changed to a state with a low-amplitude discharge current by changing the magnetic field. In a test of the PPU-TDU2, the maximum amplitude of 4.3 A calculated by the system agreed well with the peak value of 4.07 A calculated from the current waveform on an oscilloscope. These results reveal that the amplitude detection system is sufficiently accurate for thrusters of different power levels.
- 17 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 61 (1) , 930-939
Parameter Evaluation Method for Power Demand Forecasting Methodology of a Clinic
In Japan, efforts to achieve a carbon-neutral society by 2050 are underway. As part of these efforts, hospitals and clinics are particularly focusing on energy management to reduce carbon dioxide emissions with peak-cut operations. Especially, peak-cut operations necessitate accurate power demand forecasting, often facilitated by neural networks (NNs). The multilayer perceptron (MLP) and the long short-term memory (LSTM) networks represent two prominent NNs employed for this purpose. Moreover, the mean absolute error (MAE), root mean square error (RMSE), and the ratio of RMSE to MAE are used as evaluation indicators. This study employs the MLP and LSTM for the power demand forecasting of a clinic considering factors such as data partitioning, structure of the NN (the number of layers and nodes), and data period. For MLP-based forecasting models, random partitioning is preferred to improve forecasting accuracy. Additionally, for four year or longer data periods, the learning outcomes are unaffected by the structure of the NN (the number of nodes and layers). Conversely, in LSTM-based forecasting models, the choice between random and block partitioning depends on the data period. Single- or double-layer configurations show better MAE and RMSE values than three- or six-layer configurations. Employing the ratio of RMSE to MAE as an evaluation indicator, the error distribution of the NN can be estimated. The characteristics of the forecasting model can be described from the error distribution. A value of 1.414 for the ratio of RMSE to MAE indicates a Laplace distribution, a value of 1.253 indicates a normal distribution. Therefore, a good forecasting model is characterized by low RMSE to MAE values and RMSE to MAE ratios between 1.253 and 1.414.
- 17 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 61 (1) , 930-939
Parameter Evaluation Method for Power Demand Forecasting Methodology of a Clinic
In Japan, efforts to achieve a carbon-neutral society by 2050 are underway. As part of these efforts, hospitals and clinics are particularly focusing on energy management to reduce carbon dioxide emissions with peak-cut operations. Especially, peak-cut operations necessitate accurate power demand forecasting, often facilitated by neural networks (NNs). The multilayer perceptron (MLP) and the long short-term memory (LSTM) networks represent two prominent NNs employed for this purpose. Moreover, the mean absolute error (MAE), root mean square error (RMSE), and the ratio of RMSE to MAE are used as evaluation indicators. This study employs the MLP and LSTM for the power demand forecasting of a clinic considering factors such as data partitioning, structure of the NN (the number of layers and nodes), and data period. For MLP-based forecasting models, random partitioning is preferred to improve forecasting accuracy. Additionally, for four year or longer data periods, the learning outcomes are unaffected by the structure of the NN (the number of nodes and layers). Conversely, in LSTM-based forecasting models, the choice between random and block partitioning depends on the data period. Single- or double-layer configurations show better MAE and RMSE values than three- or six-layer configurations. Employing the ratio of RMSE to MAE as an evaluation indicator, the error distribution of the NN can be estimated. The characteristics of the forecasting model can be described from the error distribution. A value of 1.414 for the ratio of RMSE to MAE indicates a Laplace distribution, a value of 1.253 indicates a normal distribution. Therefore, a good forecasting model is characterized by low RMSE to MAE values and RMSE to MAE ratios between 1.253 and 1.414.
- 29 August 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 625-628
Input Voltage Unevenness Analysis in Series-Parallel DC-DC Converter
The authors have proposed the series-parallel dc-dc converter as an elemental technology to develop the power supply system that is highly compatible with renewable energy. However, when the series-parallel dc-dc converter is operated, there is an issue that the input voltage is not shared evenly by each dc-dc converter unit that consists of the series-parallel dc-dc converter. The aim of this paper is to analyze the causes of input voltage unevenness under specific conditions. By analysis of the current path through simulation, it is found that the charge and discharge of the input capacitor of each dc-dc converter unit occur, and it became clear that this leads the unevenness in the sharing of the input voltage.
- 29 August 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 625-628
Input Voltage Unevenness Analysis in Series-Parallel DC-DC Converter
The authors have proposed the series-parallel dc-dc converter as an elemental technology to develop the power supply system that is highly compatible with renewable energy. However, when the series-parallel dc-dc converter is operated, there is an issue that the input voltage is not shared evenly by each dc-dc converter unit that consists of the series-parallel dc-dc converter. The aim of this paper is to analyze the causes of input voltage unevenness under specific conditions. By analysis of the current path through simulation, it is found that the charge and discharge of the input capacitor of each dc-dc converter unit occur, and it became clear that this leads the unevenness in the sharing of the input voltage.
- 29 August 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. a247, 440-444
A Novel Type of Wireless V2H with Seamless Two-Way One-SW Converters and Asymmetric Power-Transfer Coils
In recent years, Vehicle to Home (V2H) systems, which bi-directionally link the power of smart houses and electric vehicles, have been attracting attention as a solution for stabilizing the power system in response to the large-scale introduction of renewable energy. A wireless V2H using Wireless Power Transfer (WPT) is easy to use and safe because it automatically connects to the house when parked in the carport. In this paper, proposed is a new type of wireless V2H system with stable two-way seamless WPT operation under constant frequency and excellent robustness. New resonant single-ended WPT converters with dual-active phase-difference control which requires no mutual communication and new asymmetric transfer coils of less coupling fluctuation for stable operation are discussed.
- 29 August 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. a247, 440-444
A Novel Type of Wireless V2H with Seamless Two-Way One-SW Converters and Asymmetric Power-Transfer Coils
In recent years, Vehicle to Home (V2H) systems, which bi-directionally link the power of smart houses and electric vehicles, have been attracting attention as a solution for stabilizing the power system in response to the large-scale introduction of renewable energy. A wireless V2H using Wireless Power Transfer (WPT) is easy to use and safe because it automatically connects to the house when parked in the carport. In this paper, proposed is a new type of wireless V2H system with stable two-way seamless WPT operation under constant frequency and excellent robustness. New resonant single-ended WPT converters with dual-active phase-difference control which requires no mutual communication and new asymmetric transfer coils of less coupling fluctuation for stable operation are discussed.
- 15 May 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 59 (5) , 6012-6024
Analog Controlled Critical Conduction Mode Three-Phase Vienna Rectifier
This paper proposed a novel analog-based critical conduction mode (CRM) control method for the three-phase three-level Vienna rectifier. By the proposed method, the simple analog CRM control can be achieved in each phase of the Vienna rectifier. All the control schemes are implemented with three low-cost analog CRM PFC IC controllers. The operation analysis of the CRM Vienna rectifier considering the parasitic capacitances is performed. Experimental results demonstrate that the valley-switching (VS) for IGBTs and the zero-current-switching (ZCS) for diodes are indeed achieved. A relatively high efficiency, a low input current total harmonic distortion, and a high power factor are tested at a 5.8 kW three-phase Vienna rectifier.
- 15 May 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 59 (5) , 6012-6024
Analog Controlled Critical Conduction Mode Three-Phase Vienna Rectifier
This paper proposed a novel analog-based critical conduction mode (CRM) control method for the three-phase three-level Vienna rectifier. By the proposed method, the simple analog CRM control can be achieved in each phase of the Vienna rectifier. All the control schemes are implemented with three low-cost analog CRM PFC IC controllers. The operation analysis of the CRM Vienna rectifier considering the parasitic capacitances is performed. Experimental results demonstrate that the valley-switching (VS) for IGBTs and the zero-current-switching (ZCS) for diodes are indeed achieved. A relatively high efficiency, a low input current total harmonic distortion, and a high power factor are tested at a 5.8 kW three-phase Vienna rectifier.
- Open Access
- 6 December 2022
- Published by Springer Nature in Journal of Electric Propulsion
- Vol. 1 (1) , 1-13
Control algorithm for a 6 kW hall thruster
This paper presents a control algorithm for ensuring the stable operation of a 6 kW Hall thruster. The Japan Aerospace Exploration Agency is developing a “wide-range” power processing unit (PPU) to power a 6 kW Hall thruster system, a candidate for all-electric satellites. The PPU provides discharge oscillation, power, and discharge current control. The increments in the control loop are fixed, so the PPU digital controller does not need to calculate them, and the algorithm’s computational complexity is minimal. Results of integration tests on the 6 kW Hall thruster and the PPU breadboard model showed that the three control functions run correctly. The total controlled PPU power was adjusted in the range of 3.45–3.55 kW under constant power control with a target of 3.5 kW. Oscillations of ± 0.05 kW around the target power are acceptable. 70% of the peaks in the discharge current acquired for 100 ms exceeded the limit of 1.5A. Discharge oscillation control varied the coil magnetic field and reduced them to 0%. The PPU successfully controlled the coil current, reducing the discharge current from 13.7 A to 13 A. The propulsion efficiency increased from 59% to 60.5%.
- 6 December 2022
- Published by Springer Nature in Journal of Electric Propulsion
- Vol. 1 (1) , 1-13
Open AccessControl algorithm for a 6 kW hall thruster
This paper presents a control algorithm for ensuring the stable operation of a 6 kW Hall thruster. The Japan Aerospace Exploration Agency is developing a “wide-range” power processing unit (PPU) to power a 6 kW Hall thruster system, a candidate for all-electric satellites. The PPU provides discharge oscillation, power, and discharge current control. The increments in the control loop are fixed, so the PPU digital controller does not need to calculate them, and the algorithm’s computational complexity is minimal. Results of integration tests on the 6 kW Hall thruster and the PPU breadboard model showed that the three control functions run correctly. The total controlled PPU power was adjusted in the range of 3.45–3.55 kW under constant power control with a target of 3.5 kW. Oscillations of ± 0.05 kW around the target power are acceptable. 70% of the peaks in the discharge current acquired for 100 ms exceeded the limit of 1.5A. Discharge oscillation control varied the coil magnetic field and reduced them to 0%. The PPU successfully controlled the coil current, reducing the discharge current from 13.7 A to 13 A. The propulsion efficiency increased from 59% to 60.5%.
- Open Access
Smart Grid as a Key Tool for the Future of Electrical Distribution Networks
A new paradigm has appeared in the electricity sector with the rapid development of new renewable energy sources, storage systems, information and communication technologies, and ways of integrating distributed energy sources
Open AccessSmart Grid as a Key Tool for the Future of Electrical Distribution Networks
A new paradigm has appeared in the electricity sector with the rapid development of new renewable energy sources, storage systems, information and communication technologies, and ways of integrating distributed energy sources
- 25 January 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 37 (7) , 7688-7704
Static Analysis of a Digital Peak Current Mode Control DC–DC Converter Using Current–Frequency Conversion
The purpose of this article is to discuss the design guideline and design chart of the digital peak current mode dc–dc converter using a current–frequency conversion by analyzing its static characteristics. The operation of the proposed method is expressed by equations, and the relationships between controller parameters are derived. This discussion reveals the relationships between the peak current instruction value and the output voltage or peak current, which are necessary for designing the proposed method. Then, the design guideline and design chart are given. The validity of the static characteristic analysis is demonstrated by a prototype, whose design follows the design guideline. An appropriate operation in the steady and static state is also indicated by the experiment. As a result, the validity of the static characteristics and the design guideline of the proposed method can be verified.
- 25 January 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 37 (7) , 7688-7704
Static Analysis of a Digital Peak Current Mode Control DC–DC Converter Using Current–Frequency Conversion
The purpose of this article is to discuss the design guideline and design chart of the digital peak current mode dc–dc converter using a current–frequency conversion by analyzing its static characteristics. The operation of the proposed method is expressed by equations, and the relationships between controller parameters are derived. This discussion reveals the relationships between the peak current instruction value and the output voltage or peak current, which are necessary for designing the proposed method. Then, the design guideline and design chart are given. The validity of the static characteristic analysis is demonstrated by a prototype, whose design follows the design guideline. An appropriate operation in the steady and static state is also indicated by the experiment. As a result, the validity of the static characteristics and the design guideline of the proposed method can be verified.