Shuyang Han
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Shuyang Han has a total of 82 co-authors. Here are the top co-authors by number of shared publications:
Sabir K. Ismaily
Department of Orthopedic Surgery, McGovern Medical School, University of Texas Health Science Center at Houston, Houston, Texas
11 shared publicationsPhilip C. Noble
Department of Orthopedic Surgery, McGovern Medical School, University of Texas Health Science Center at Houston, Houston, Texas
7 shared publicationsDavid Rodriguez-Quintana
Department of Orthopedic Surgery, McGovern Medical School, University of Texas Health Science Center at Houston, Houston, Texas
5 shared publicationsDavid B. Doherty
Department of Orthopedic Surgery, McGovern Medical School University of Texas Health Science Center at Houston Houston Texas USA
4 shared publicationsJonathan E. Gold
Department of Orthopedic Surgery, McGovern Medical School, University of Texas Health Science Center at Houston, Houston, Texas
4 shared publications- Joshua David Harris
Department of Orthopedics & Sports Medicine, Houston Methodist Hospital, Houston, Texas
4 shared publications
Latest Publications
- 6 May 2025
- Published by Elsevier in The Journal of Arthroplasty
- Vol. 40 (9) , S564-S570
Does Stem Design Affect Primary Stability of Splined Tapered Fluted Stems? A Biomechanical Cadaver Study
- 6 May 2025
- Published by Elsevier in The Journal of Arthroplasty
- Vol. 40 (9) , S564-S570
Does Stem Design Affect Primary Stability of Splined Tapered Fluted Stems? A Biomechanical Cadaver Study
A goal‐directed rehabilitation protocol for people with transfemoral amputation receiving osseointegration prostheses
Background: Osseointegration (OI) has become an increasingly popular option for people with amputations around the world. However, limited information is available regarding the rehabilitation protocols before and after OI surgery, particularly for the civilian population who face several constraints.Objective: To evaluate the effectiveness of a civilian‐focused, goal‐directed rehabilitation protocol for patients with transfemoral amputation receiving a screw‐type OI prosthesis to optimize functional outcomes.Design: A retrospective cohort study of patients with transfemoral amputation who received OI surgery.Setting: A national rehabilitation innovation center.Patients: Ten patients treated by the same orthopedic surgeon using the Osseoanchored Prostheses for the Rehabilitation of Amputees (OPRA) system were included in this study.Methods: Prehabilitation and rehabilitation protocols for the civilian population were developed, which outlined week‐by‐week, progressive rehabilitation goals before and longitudinally after the OI surgery. After Stage 2 of the surgery, patient outcome was evaluated using outcome measures at 6 months and 1 year.Results: On average, the number of rehabilitation sessions received by the patients was 15.9 ± 4.5 at 6 months, which increased to 26.7 ± 10.2 at 1 year. There were significant improvements in the Amputee Mobility Predictor (37.9 ± 5.0 vs. 38.9 ± 4.8, p = .003), 6‐Minute Walk Test (225.3 ± 118.5 vs. 264.0 ±143.3 m, p = .02), and 10 M fast walk (11.9 ± 3.5 vs. 9.3 ± 2.4 seconds, p = .03). The 10‐M self‐paced walk test reduced from 19.5 ± 9.9 seconds at 6 months to 12.1 ± 4.7 seconds at 1 year, although the difference was insignificant (p = .20). At the conclusion of the study, all patients were walking post OI surgery.Conclusions: Given the constraints faced by civilians with transfemoral amputation, we proposed a rehabilitation protocol for the population who received OI prostheses. Critical clinical milestones were presented to guide rehabilitation progression. Initial results showed improvements in certain outcome measures between 6 months and 12 months following Stage 2 surgery. However, long‐term randomized control studies are needed to further validate its efficacy.
A goal‐directed rehabilitation protocol for people with transfemoral amputation receiving osseointegration prostheses
Background: Osseointegration (OI) has become an increasingly popular option for people with amputations around the world. However, limited information is available regarding the rehabilitation protocols before and after OI surgery, particularly for the civilian population who face several constraints.Objective: To evaluate the effectiveness of a civilian‐focused, goal‐directed rehabilitation protocol for patients with transfemoral amputation receiving a screw‐type OI prosthesis to optimize functional outcomes.Design: A retrospective cohort study of patients with transfemoral amputation who received OI surgery.Setting: A national rehabilitation innovation center.Patients: Ten patients treated by the same orthopedic surgeon using the Osseoanchored Prostheses for the Rehabilitation of Amputees (OPRA) system were included in this study.Methods: Prehabilitation and rehabilitation protocols for the civilian population were developed, which outlined week‐by‐week, progressive rehabilitation goals before and longitudinally after the OI surgery. After Stage 2 of the surgery, patient outcome was evaluated using outcome measures at 6 months and 1 year.Results: On average, the number of rehabilitation sessions received by the patients was 15.9 ± 4.5 at 6 months, which increased to 26.7 ± 10.2 at 1 year. There were significant improvements in the Amputee Mobility Predictor (37.9 ± 5.0 vs. 38.9 ± 4.8, p = .003), 6‐Minute Walk Test (225.3 ± 118.5 vs. 264.0 ±143.3 m, p = .02), and 10 M fast walk (11.9 ± 3.5 vs. 9.3 ± 2.4 seconds, p = .03). The 10‐M self‐paced walk test reduced from 19.5 ± 9.9 seconds at 6 months to 12.1 ± 4.7 seconds at 1 year, although the difference was insignificant (p = .20). At the conclusion of the study, all patients were walking post OI surgery.Conclusions: Given the constraints faced by civilians with transfemoral amputation, we proposed a rehabilitation protocol for the population who received OI prostheses. Critical clinical milestones were presented to guide rehabilitation progression. Initial results showed improvements in certain outcome measures between 6 months and 12 months following Stage 2 surgery. However, long‐term randomized control studies are needed to further validate its efficacy.
- 10 April 2025
- Published by Elsevier in The Journal of Arthroplasty
- Vol. 40 (8) , S55-S61
Patient-Specific Preoperative Plans Can Optimize Femoral Head Coverage and Range of Motion After Periacetabular Osteotomies
- 10 April 2025
- Published by Elsevier in The Journal of Arthroplasty
- Vol. 40 (8) , S55-S61
Patient-Specific Preoperative Plans Can Optimize Femoral Head Coverage and Range of Motion After Periacetabular Osteotomies
- 23 November 2024
- Published by Springer Nature in European Journal of Orthopaedic Surgery & Traumatology
- Vol. 35 (1) , 1-8
Does contemporary total knee designs replicate the anatomy of the native trochlea?
Purpose Registry data shows that less surgeons are resurfacing the patella during total knee arthroplasty (TKA). This tendency highlights the importance of matching trochlear and native patellar anatomy. Currently, there is a lack of consensus on implant design that best accommodates native patellae. The objective of this study was to compare the trochlear morphology of a large selection of contemporary TKA designs with the native trochlear anatomy. Methods Three-dimensional models of 13 femoral component designs from seven manufacturers and 37 healthy human femora (average age: 31.2 ± 13.4 years) were reconstructed. The trochlear morphology, including trochlear length, sulcus angle, trochlear groove angle, and height and width of the medial and lateral facets, was measured along the trochlea at 15° increments. Results The prosthetic trochlea was shorter and shallower compared to the native trochlea (p < 0.01). The native trochlea was bilinear and had a medial orientation proximally, whereas all asymmetrical TKA designs had a laterally oriented trochlea, resulting in opposite trochlear groove orientation (TKA, 5.8 ± 3.7°; native -3.1 ± 4.1°, p < 0.001). In addition, a strong correlation (R2 = 0.89) was found in TKA models between the heights of the medial and lateral facets, which was not observed for the native femora (R2 = 0.06). Conclusion This study highlights that the lateral trochlear orientation in existing TKA models is not anatomical. Given the rising trend in patellar non-resurfacing during TKA, further studies are necessary to improve trochlear design that better accommodates the native patellar morphology.
- 23 November 2024
- Published by Springer Nature in European Journal of Orthopaedic Surgery & Traumatology
- Vol. 35 (1) , 1-8
Does contemporary total knee designs replicate the anatomy of the native trochlea?
Purpose Registry data shows that less surgeons are resurfacing the patella during total knee arthroplasty (TKA). This tendency highlights the importance of matching trochlear and native patellar anatomy. Currently, there is a lack of consensus on implant design that best accommodates native patellae. The objective of this study was to compare the trochlear morphology of a large selection of contemporary TKA designs with the native trochlear anatomy. Methods Three-dimensional models of 13 femoral component designs from seven manufacturers and 37 healthy human femora (average age: 31.2 ± 13.4 years) were reconstructed. The trochlear morphology, including trochlear length, sulcus angle, trochlear groove angle, and height and width of the medial and lateral facets, was measured along the trochlea at 15° increments. Results The prosthetic trochlea was shorter and shallower compared to the native trochlea (p < 0.01). The native trochlea was bilinear and had a medial orientation proximally, whereas all asymmetrical TKA designs had a laterally oriented trochlea, resulting in opposite trochlear groove orientation (TKA, 5.8 ± 3.7°; native -3.1 ± 4.1°, p < 0.001). In addition, a strong correlation (R2 = 0.89) was found in TKA models between the heights of the medial and lateral facets, which was not observed for the native femora (R2 = 0.06). Conclusion This study highlights that the lateral trochlear orientation in existing TKA models is not anatomical. Given the rising trend in patellar non-resurfacing during TKA, further studies are necessary to improve trochlear design that better accommodates the native patellar morphology.
- 16 October 2024
- Published by Elsevier in Clinical Biomechanics
- Vol. 120, 106362
Is suture-based cerclage biomechanically superior to traditional metallic cerclage for fixation of periprosthetic femoral fractures: A matched pair cadaveric study
- 16 October 2024
- Published by Elsevier in Clinical Biomechanics
- Vol. 120, 106362
Is suture-based cerclage biomechanically superior to traditional metallic cerclage for fixation of periprosthetic femoral fractures: A matched pair cadaveric study
- 1 September 2024
- Published by Wolters Kluwer Health in Journal of Orthopaedic Trauma
- Vol. 38 (9) , 491-496
Impact of Prophylactic Cerclage Location on Femoral Fracture Propagation: A Biomechanical Study
OBJECTIVES: Prophylactic cerclage cables are often placed intraoperatively about a fracture to prevent propagation. However, biomechanical data supporting optimal cable placement location are lacking. The objective of this study was to evaluate the impact of prophylactic cerclage placement location on the propagation of femoral shaft fractures. METHODS: The diaphysis of 14 fresh-frozen cadaveric femora were included. Volumetric bone mineral density in the femoral shaft was obtained from quantitative computed tomography scans. For each specimen, a 5-mm longitudinal fracture was created proximally to simulate a pre-existing fracture. After reaming of the femoral canal, a 3 degrees tapered wedge was advanced with an MTS machine at 0.2 mm/s until failure. The tests were conducted with a CoCr cable placed at varying distances (5 mm, 10 mm, 15 mm, 20 mm, and cableless) from the distal tip of the initial fracture. A compression loadcell was used to measure the cable tension during the tests. The axial force, displacement, and cable tension were monitored for comparison between groups. RESULTS: In the cableless group, the mean force needed to propagate the fracture was 1017.8 ± 450.3 N. With the addition of a cable at 5 mm below the fracture, the failure force nearly doubled to 1970.4 ± 801.1 N (P < 0.001). This also led to significant increases in stiffness (P = 0.006) and total work (P = 0.001) when compared with the control group. By contrast, in the 15 and 20 mm groups, there were no significant changes in the failure force, stiffness, and total work as compared with the control group (P > 0.05). CONCLUSIONS: Propagation of femoral shaft fracture was effectively resisted when a prophylactic cable was placed within 5 mm from the initial fracture, whereas cables placed more than 10 mm below the initial fracture were not effective in preventing fracture propagation.
- 1 September 2024
- Published by Wolters Kluwer Health in Journal of Orthopaedic Trauma
- Vol. 38 (9) , 491-496
Impact of Prophylactic Cerclage Location on Femoral Fracture Propagation: A Biomechanical Study
OBJECTIVES: Prophylactic cerclage cables are often placed intraoperatively about a fracture to prevent propagation. However, biomechanical data supporting optimal cable placement location are lacking. The objective of this study was to evaluate the impact of prophylactic cerclage placement location on the propagation of femoral shaft fractures. METHODS: The diaphysis of 14 fresh-frozen cadaveric femora were included. Volumetric bone mineral density in the femoral shaft was obtained from quantitative computed tomography scans. For each specimen, a 5-mm longitudinal fracture was created proximally to simulate a pre-existing fracture. After reaming of the femoral canal, a 3 degrees tapered wedge was advanced with an MTS machine at 0.2 mm/s until failure. The tests were conducted with a CoCr cable placed at varying distances (5 mm, 10 mm, 15 mm, 20 mm, and cableless) from the distal tip of the initial fracture. A compression loadcell was used to measure the cable tension during the tests. The axial force, displacement, and cable tension were monitored for comparison between groups. RESULTS: In the cableless group, the mean force needed to propagate the fracture was 1017.8 ± 450.3 N. With the addition of a cable at 5 mm below the fracture, the failure force nearly doubled to 1970.4 ± 801.1 N (P < 0.001). This also led to significant increases in stiffness (P = 0.006) and total work (P = 0.001) when compared with the control group. By contrast, in the 15 and 20 mm groups, there were no significant changes in the failure force, stiffness, and total work as compared with the control group (P > 0.05). CONCLUSIONS: Propagation of femoral shaft fracture was effectively resisted when a prophylactic cable was placed within 5 mm from the initial fracture, whereas cables placed more than 10 mm below the initial fracture were not effective in preventing fracture propagation.
- 6 July 2024
- Published by Elsevier in Clinical Biomechanics
- Vol. 118, 106303
Contributions of capsular releases to femoral exposure in total hip arthroplasty via the direct anterior approach
- 6 July 2024
- Published by Elsevier in Clinical Biomechanics
- Vol. 118, 106303
Contributions of capsular releases to femoral exposure in total hip arthroplasty via the direct anterior approach
- 12 December 2023
- Published by Elsevier in Journal of Clinical Orthopaedics and Trauma
- Vol. 47, 102313
The hidden impact of orthopedic surgeries: Examining the psychological consequences
- 12 December 2023
- Published by Elsevier in Journal of Clinical Orthopaedics and Trauma
- Vol. 47, 102313
The hidden impact of orthopedic surgeries: Examining the psychological consequences