Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Archana Mootha has a total of 7 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Is There a Similarity in Serum Cytokine Profile between Patients with Periodontitis or 2019-Novel Coronavirus Infection?—A Scoping Review

    by Archana Mootha

    On 11 March 2020, the WHO declared a global emergency as a result of the ‘novel coronavirus infection’, which emerged from Wuhan, China, and rapidly spread across international borders. There is vast evidence that supports a direct link between oral cavities and this systemic circulation, but it is still unclear if oral conditions like periodontitis influenced the COVID-19 disease outcome. This scoping review highlights the fact that both periodontitis and COVID-19 independently increase serum pro-inflammatory cytokine levels, however there is a lack of documentation on if this biochemical profile synergizes with COVID-19 and/or periodontal severity in the same individuals. The purpose of this scoping review is to accumulate existing data on the serums IL-1β, IL-6, and TNF-α in COVID-19 and periodontitis patients and check if periodontitis negatively impacts the COVID-19 outcome, educating the population about the implications of COVID-19-related complications on their oral health, and vice versa, and motivating patients towards oral hygiene maintenance.


  • Open Access

    Refinement of synthetic guanine crystals for fast diamagnetic rotation

    by Archana Mootha, Kentaro Suzuki, Takayuki Kimura, Masaru Kurahashi, Etsuhiro Muneyama, Masakazu Iwasaka, Hironori Asada

    Synthetic guanine crystals, with the same magnetic controllable reflection property as a biogenic guanine crystal from fish scales, were prepared using a classical Ostwald ripening method for crude crystals, from the aqueous sodium hydroxide solution of a commercially available synthesized guanine powder. The resulting synthetic guanine crystals with an average size of several tens of micrometers were in the same crystal system as the biogenic guanine crystals under measurement by X-ray diffraction (XRD). However, XRD patterns of water-floating crystals showed that the correlation between the growing direction and reflecting surface in the synthetic crystals is different from that in the biogenic crystals. Therefore, the synthetic crystals were ground by an agate mortar for refinement of its optical and magnetic-orientation characters. As a result, we realized a fast-magnetic orientation against the vertical field, which is related to the magnetic control of light reflection, the same as the biogenic guanine crystal behavior.


  • Guanine Vesicle Hybrid Particles for Bio-Reflector-Based Bio-Imaging

    by Archana Mootha, Kentaro Suzuki, Hironori Asada, Masakazu Iwasaka

    The ability to visualize biological processes in real time rather than observing them at discrete points of time holds huge applicability in understanding the incredible processes of how the human body behaves during disease progression and healing. The prospects of live cell imaging include observing changes during cell differentiation, signaling, and molecular analysis of cell cycle including targeted drug delivery. Studying cells in real time assist in recording invaluable data whose knowledge holds great importance in understanding several aspects of cell functions at both microscopic and macroscopic levels. Cell labeling using photonic crystals for live cell imaging has never been tried before. Guanine crystals (GCs) are optical nanoparticles having fulgent light reflective properties that respond rapidly and align parallel to an applied magnetic field. Our target was to fabricate a brilliant “hybrid vesicle” using guanine inside lipid vesicles. Under dark field microscopy, GC shone brilliantly, causing strong illumination of the lipid vesicles with increased motion of vesicles under magnetic exposure. We think that “hybrid vesicle” could possibly be used for real-time cell tracking in live cell bio-imaging.


  • Open Access

    Quenching of light flickering in synthetic guanine crystals in aqueous solutions under strong static magnetic fields

    by A. Mootha, Y. Takanezawa, M. Iwasaka

    The present study focused on the vibration of micro crystal particles of guanine due to Brownian motion. The organic particle has a refractive index of 1.83 and caused a flickering of light. To test the possibility of using magnetic properties under wet conditions, changes in the frequency of particle vibration by applying magnetic fields were investigated. At first, we found that the exposure at 5 T inhibited the flickering light intensities and the particle vibration slightly decreased. Next, we carried out a high speed camera measurement of the Brownian motion of the particle with a time resolution of 100 flame per second (fps) with and without magnetic field exposures. It was revealed that the vibrational speed of synthetic particles was enhanced at 500 mT. Detailed analyses of the particle vibration by changing the direction of magnetic fields versus the light source revealed that the Brownian motion’s vibrational frequency was entrained under magnetic fields at 500 mT, and an increase in vibration speed to 20Hz was observed. Additional measurements of light scattering fluctuation using photo-detector and analyses on auto-correlation also confirmed this speculation. The studied Brownian vibration may be influenced by the change in mechanical interactions between the vibration particles and surrounding medium. The discovered phenomena can be applied for molecular and biological interactions in future studies.