RKRao Khan

Rao Khan

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Rao Khan has a total of 129 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    In vitro gold nanoparticle radiation sensitization effects in conjunction with a 2.5 megavoltage photon beam in MDA-MB-231, HeLa and PC-3 cell lines

    by Xiao Qing Yao, Sarah A Sabatinos, Eric Da Silva, Rao Khan, James L Gräfe, Raffi Karshafian

    Purpose: To study gold nanoparticle (GNP) mediated radiosensitization across three tumour cells lines that vary in radiosensitivity for a 2.5 MV X-ray beam. The intrinsic sensitivity of the cell lines is studied for the effects of GNPs. Materials and methods: Prostate adenocarcinoma (PC-3), breast adenocarcinoma (MDA-MB-231), and cervical adenocarcinoma (HeLa) cells were used to determine the in vitro dose enhancement effects of GNPs combined with a 2.5 MV photon beam to determine the feasibility of irradiating cells with 2.5 MV in cell lines which exhibit different radiation response. Cells were incubated with 20 μg/mL GNPs for 24 hours, and any extracellular GNPs were washed out prior to each assay. The cellular uptake of GNPs was assessed with inductively coupled plasma optical emission spectroscopy (ICP-OES). Clonogenic assays were conducted to assess cell viability after irradiation. The biological damage was assessed through DNA damage using terminal deoxynucleotidyl transferase dUTP nick end labeling assay (TUNEL). The production of reactive oxygen species (ROS) was assessed using CellRox assays. Results: The enhancement factor when cells were irradiated in the presence of GNPs with 2.5 MV was 1.35±0.46 for HeLa, 1.35±0.11 for MDA-MB-231, and 0.99±0.08 for PC-3 cells. On average, the level of DNA damage increased in MDA-MB-231 and HeLa cells when irradiated with 2.5 MV in the presence of GNPs. Increase in the ROS levels were detected in all cell lines when irradiated in the presence of GNPs. Conclusions: The enhancement effects with GNPs combined with a 2.5 MV photon beam were dependent on the cell line. The enhancement factor for HeLa and MDA-MB-231 supports further investigation of intermediate photon-energy beams in combination with GNPs. The combination of using a conventionally lower energy megavoltage beam with gold nanoparticles may become applicable in the clinical setting due to reduced skin dose and enhanced secondary electron production.

  • Open Access

    Benchmarking Radiochromic EBT4 Film for Clinical Proton Dosimetry

    by Robabeh Rahimi, Kuan Ling Chen, Jiajin Fan, Rao Khan


  • Systematic characterization of new EBT4 radiochromic films in clinical x-ray beams

    by Rao Khan, Robabeh Rahimi, Jiajin Fan, Kuan Ling Chen

    Objective. We aim to characterize kinetics of radiation-induced optical density in newly released EBT4 radiochromic films exposed to clinical x-rays. Several film models and batches were evaluated for the film sensitivity, optical signal increasing with time, relative film noise, and minimum detectable limits (MDL). Approach. Radiochromic film pieces from a single batch of EBT3 and three batches of EBT4 were exposed to doses of 77.38 cGy, 386.92 cGy, and 773.84 cGy using a 6 MV x-ray beam. The films were scanned with a flatbed scanner at specific time intervals up to 120 h. The time-series net optical density of red, green and blue colors was corrected for response of the scanner with time and studied to establish the saturation characteristics of film polymerization process. Dose–response from 3.86 cGy to 1935 cGy was also determined for each color. MDL of the films was quantitatively defined as the dose that would double the net optical density of red color above the standard deviation of the residual signal at zero dose. The relative noise characteristics of EBT3 versus EBT4 were studied as a function of time, dose and scanner resolution. Main Results. For doses ≥ 100 cGy, analysis revealed a stability of optical density beyond 48 h post-exposure for EBT3 and EBT4 films. EBT3 films attained 80%-90% of their net optical density at 48 h within minutes of irradiation, compared to 72%-88% for EBT4 films. The rate of growth was slowest for blue color, fastest for red, while green was in between the two. The MDL for EBT4 averaged 15 cGy for three batches, whereas EBT3 films reliably detected doses as low as 8.5 cGy. Significance. Several batches of the new EBT4 film showed slightly lower response compared to its predecessor over 3.86 cGy to 1935 Gy range. For all practical purposes, the post-irradiation growth of polymers ceases between 48 to 60 h for both EBT films. Overall, the EBT4 film exhibited noise characteristics similar to EBT3, except for lower doses where the noise was observed to be higher than its predecessor.


  • RBE-based dose planning, and calculation of TCP and NTCP with gold nanoparticles for intermediate photon energy in pancreatic cancer

    by Navid Khaledi, Raffi Karshafian, Amandeep S Taggar, Khalid Alrabiah, Rao Khan, James L Gräfe

    Objective. This study simulated the potential of gold nanoparticles (GNPs) to improve the effectiveness of radiation therapy in pancreatic cancer cases. The purpose of this study was to assess the impact of GNPs on tumor control probability (TCP) and normal tissue complication probability (NTCP) in pancreatic cancer cases undergoing radiation therapy. The work aimed to compare treatment plans generated with a novel 2.5 MV beam using GNPs to conventional 6 MV plans and evaluate the dose-volume histogram (DVH), TCP, and NTCP. Approach. Treatment planning for five pancreatic computed tomography (CT) images was performed using the open-source MATLAB-based treatment planning program matRad. MATLAB codes were developed to calculate the relative biological effectiveness (RBE) of GNPs and apply the corresponding dose and RBE values to each voxel. TCP and NTCP were calculated based on the applied RBE values. Main results. Adding GNPs to the 2.5 MV treatment plan resulted in a significant increase in TCP, from around 59% to 93.5%, indicating that the inclusion of GNPs improved the effectiveness of the radiation treatment. The range in NTCP without GNPs was relatively larger compared to that with GNPs. Significance. The results indicated that the addition of GNPs to a 2.5 MV plan can increase TCP while maintaining a relatively low NTCP value (<1%). The use of GNPs may also reduce NTCP values by decreasing the dose to normal tissues while maintaining the same prescribed dose to the tumor. Hence, the addition of GNPs can improve the balance between TCP and NTCP.


  • Spectroscopic analysis of irradiated radiochromic EBT-XD films in proton and photon beams

    by Arash Darafsheh, Tianyu Zhao, Rao Khan

    The response of Gafchromic TM EBT-XD films to proton irradiation using a Mevion S250 TM proton therapy system is studied in this work. Film samples from different batches were irradiated with doses from 0.25 Gy to 20 Gy using a Mevion S250 spread-out Bragg peak (SOBP) clinical proton beam. Using a fiber-coupled optical spectrometer, transmission spectra of the films were acquired over 400–800 nm range (with 2.5 nm resolution). The optical density (OD) of the films was also measured with a flatbed scanner. The characteristics of the film were investigated for dependencies on dose, inter-batch, energy, linear energy transfer (LET), and radiation type. Post-irradiation temporal growth of the OD of the films was also investigated. The net absorbance spectra of EBT-XD films exhibited two absorption peaks located at 636 nm and 585 nm. The measurement of percentage depth dose with the films showed ∼1%–5% and 7%–8% under-estimation on the dose in mid-SOBP and distal SOBP regions, respectively, compared to ionization chamber measurement. No significant energy dependence was noted in the OD of the films when irradiated at the same dose using different proton energies. Approximately 4%–10% drop in spectral response was seen for the proton-irradiated films relative to the films irradiated in photon beams. Temporal growth of the optical density showed a different developing slope between photon and proton irradiation in the first 12 h, but both reached a stable response 24 h after irradiation.


  • Neutron measurements with a CdTe spectrometer on a proton therapy unit

    by Kurt W. Van Delinder, Daniel Crawford, Tiezhi Zhang, Rao Khan, James L. Gräfe


  • Open Access

    Mitigating disruptions, and scalability of radiation oncology physics work during the COVID‐19 pandemic

    by Arash Darafsheh, Hossein Lavvafi, Reza Taleei, Rao Khan

    Purpose: The COVID‐19 pandemic has led to disorder in work and livelihood of a majority of the modern world. In this work, we review its major impacts on procedures and workflow of clinical physics tasks, and suggest alternate pathways to avoid major disruption or discontinuity of physics tasks in the context of small, medium, and large radiation oncology clinics. We also evaluate scalability of medical physics under the stress of “social distancing”.Methods: Three models of facilities characterized by the number of clinical physicists, daily patient throughput, and equipment were identified for this purpose. For identical objectives of continuity of clinical operations, with constraints such as social distancing and unavailability of staff due to system strain, however with the possibility of remote operations, the performance of these models was investigated. General clinical tasks requiring on‐site personnel presence or otherwise were evaluated to determine the scalability of the three models at this point in the course of disease spread within their surroundings.Results: The clinical physics tasks within three models could be divided into two categories. The former, which requires individual presence, include safety‐sensitive radiation delivery, high dose per fraction treatments, brachytherapy procedures, fulfilling state and nuclear regulatory commission's requirements, etc. The latter, which can be handled through remote means, include dose planning, physics plan review and supervision of quality assurance, general troubleshooting, etc.Conclusion: At the current level of disease in the United States, all three models have sustained major system stress in continuing reduced operation. However, the small clinic model may not perform if either the current level of infections is maintained for long or staff becomes unavailable due to health issues. With abundance, and diversity of innovative resources, medium and large clinic models can sustain further for physics‐related radiotherapy services.


  • Telecommuting: A viable option for medical physicists amid the COVID‐19 outbreak and beyond

    by Holly Lincoln, Rao Khan, Jing Cai

    The impact of recent outbreak of novel coronavirus disease, COVID‐19, to the global healthcare systems is unprecedently enormous. Like many other clinical disciplines, medical physics has encountered unique challenges during this special period in wider aspects from clinical practice, research, administration to education. As hospitals implement various preventive and control measures to contain the virus, medical physicists are asked to perform non‐essential activities by telecommuting or work‐from‐home (WFH) in many places.


  • Investigating neutron activated contrast agent imaging for tumor localization in proton therapy: a feasibility study for proton neutron gamma-x detection (PNGXD)

    by Kurt W Van Delinder, Daniel Crawford, Tiezhi Zhang, Rao Khan, James L Gräfe

    Proton neutron gamma-x detection (PNGXD) is a novel imaging concept being investigated for tumor localization during proton therapy that uses secondary neutron interactions with a gadolinium contrast agent (GDCA) to produce characteristic photons within the 40–200 keV energy region. The purpose of this study is to experimentally investigate the feasibility of implementing this procedure by performing experimental measurements on a passive double scattering proton treatment unit. Five experimental measurements were performed with varying concentrations and irradiation conditions. Photon spectra were measured with a 25 mm 2 , 1 mm thick uncollimated X-123 CdTe spectrometer. For a 10.4 Gy administration on a 100 ml volume phantom with 10 mg g −1 Gd solution placed in a water phantom, 1129 ± 184 K-shell Gd counts were detected. For an administered dose of 21 Gy and the same Gd solution measured in air, resulted in 3296 ± 256 counts. A total of 1094 ± 171, 421 ± 150 and 23 ± 141 K-shell Gd counts were measured for Gd concentrations of 10 mg g −1 , 1 mg g −1 and 0 mg g −1 for 7 Gy dose in air. The signal to noise ratio for these five measurements were: 7, 15, 6, 3, and 0.2, respectively. The spectrum contained 43 keV K α and 49 keV K β peaks, however a small amount of 79.5 and 181.9 keV prompt gamma rays were detected from gadolinium neutron capture. This discrepancy is due to a drop in the intrinsic detection efficiency of the CdTe spectrometer over this energy range. The measurements were compared with Monte-Carlo simulation to determine the contributions of Gd neutron capture from internal and external neutrons on a passive scattering proton therapy unit and to investigate the discrepancy in detected characteristic x-rays versus prompt gamma rays.


  • Response characterization of EBT‐XD radiochromic films in megavoltage photon and electron beams

    by E. Yazmin León‐Marroquín, Daniel Mulrow, Arash Darafsheh, Rao Khan

    Purpose: The purpose of this study was to investigate the beam quality dependence of the EBT‐XD radiochromic films for megavoltage photon and electron beam irradiations by studying their spectral response. Dose, dose rate, and interbatch dependencies were investigated as well.Methods: EBT‐XD and EBT3 radiochromic films were cut into 5 cm2 × 5 cm2 pieces, placed between solid water phantoms, and irradiated with 6 and 15 MV photon beams, 6 and 10 MV flattening filter free photon beams, and 6 and 20 MeV electron beams at dose levels between 0.5 and 50 Gy. In order to measure the spectral response, the films were illuminated by a deuterium and tungsten‐halogen lamp and net absorption was measured in 400–800 nm spectral range using a fiber‐coupled optical spectrometer. Film samples were then analyzed using a flatbed scanner in the red, green, and blue channel to obtain the optical density of the films.Results: The net absorption spectra of the EBT‐XD and EBT3 films showed two absorption bands centered at 635 and 585 nm, characteristic of the EBT model. However, for a given dose, the EBT‐XD films showed lower net absorbance compared to the EBT3 films. At a given dose level, the net absorption spectra and dose–response curves for EBT‐XD films showed only slight variations across various beam qualities. When a calibration curve obtained from a given beam quality is used to measure dose from films irradiated with other beam qualities, the maximum uncertainty in the calculated dose, in ranges 5–40 and 8–50 Gy for red and green channels, respectively, were ~3.1% and ~2.4%.Conclusions: The response of the EBT‐XD films is dose rate independent but batch dependent. No significant beam quality dependence was observed in EBT‐XD films in the dose range up to 50 Gy.