Joachim von Zanthier
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Joachim von Zanthier has a total of 267 co-authors. Here are the top co-authors by number of shared publications:
H. Walther
Max-Planck-Institut für Quantenoptik and Sektion Physik der Ludwig-Maximilians-Universität München, 85748 Garching, Germany
23 shared publicationsG. S. Agarwal
Department of Physics, Oklahoma State University, Stillwater, Oklahoma 74078, USA
18 shared publications- Thierry Bastin
University of Liège
13 shared publications C. Thiel
Institut für Optik, Information und Photonik, Universität Erlangen-Nürnberg, Erlangen, Germany
8 shared publications- Ekkehard Peik
Physikalisch-Technische Bundesanstalt (PTB), Braunschweig, Germany
8 shared publications - Stefan Richter
Institut für Optik, Information und Photonik, Friedrich-Alexander Universität Erlangen-Nürnberg, Staudtstraße 1, 91058 Erlangen, Germany
8 shared publications
Latest Publications
- 8 October 2026
- Published by American Physical Society (APS) in Physical Review A
- Vol. 114 (4) , 043710
Deviations from thermal light statistics in ensembles of independent two-level emitters
We investigate the light statistics of an ensemble of independent motionless two-level atoms in a product state. In particular, we explore under which conditions the atomic ensemble produces light similar to that of a classical thermal source obeying the Gaussian moment theorem (GMT). We derive leading-order corrections due to finite-size and spin-coherence effects, providing a guide to the deviation from thermal statistics and the GMT. We discuss the validity of the corrections for atoms in either a pure or mixed state. Our results contribute to the understanding of the generation of thermal light by two-level atoms without interactions among the emitters.
- 8 October 2026
- Published by American Physical Society (APS) in Physical Review A
- Vol. 114 (4) , 043710
Deviations from thermal light statistics in ensembles of independent two-level emitters
We investigate the light statistics of an ensemble of independent motionless two-level atoms in a product state. In particular, we explore under which conditions the atomic ensemble produces light similar to that of a classical thermal source obeying the Gaussian moment theorem (GMT). We derive leading-order corrections due to finite-size and spin-coherence effects, providing a guide to the deviation from thermal statistics and the GMT. We discuss the validity of the corrections for atoms in either a pure or mixed state. Our results contribute to the understanding of the generation of thermal light by two-level atoms without interactions among the emitters.
- Open Access
- 19 September 2026
- Published by Springer Nature in Scientific Reports
Real-time measurement error mitigation for one-way quantum computation
We propose a quantum error mitigation scheme for single-qubit measurement errors, particularly suited for one-way quantum computation. Contrary to well established error mitigation methods for circuit-based quantum computation that require the circuits to be run several times, our method is capable of mitigating measurement errors in real time during the processing measurements in the one-way computation. For that, an ancillary qubit register is entangled with the to-be-measured qubit and additionally measured afterwards. By using a voting protocol on all measurement outcomes, occurring measurement errors can be mitigated in real time while the one-way computation continues. We provide an analytical expression for the probability to detect a measurement error depending on the error rate and the number of ancilla qubits. From this, we derive an estimate of the ancilla register size for a given measurement error rate and a required success probability to detect a measurement error. Additionally, we consider the CNOT gate error in our mitigation method and investigate how this influences the probability to detect a measurement error. Finally, we show in proof-of-principle simulations and in experiments executed on IBM quantum hardware that our method is capable of reducing the measurement errors significantly in a one-way quantum computation with only a small number of ancilla qubits.
- 19 September 2026
- Published by Springer Nature in Scientific Reports
Open AccessReal-time measurement error mitigation for one-way quantum computation
We propose a quantum error mitigation scheme for single-qubit measurement errors, particularly suited for one-way quantum computation. Contrary to well established error mitigation methods for circuit-based quantum computation that require the circuits to be run several times, our method is capable of mitigating measurement errors in real time during the processing measurements in the one-way computation. For that, an ancillary qubit register is entangled with the to-be-measured qubit and additionally measured afterwards. By using a voting protocol on all measurement outcomes, occurring measurement errors can be mitigated in real time while the one-way computation continues. We provide an analytical expression for the probability to detect a measurement error depending on the error rate and the number of ancilla qubits. From this, we derive an estimate of the ancilla register size for a given measurement error rate and a required success probability to detect a measurement error. Additionally, we consider the CNOT gate error in our mitigation method and investigate how this influences the probability to detect a measurement error. Finally, we show in proof-of-principle simulations and in experiments executed on IBM quantum hardware that our method is capable of reducing the measurement errors significantly in a one-way quantum computation with only a small number of ancilla qubits.
- 4 December 2025
- Published by American Physical Society (APS) in Physical Review A
- Vol. 112 (6)
Light statistics from large ensembles of independent two-level emitters: Classical and nonclassical effects
- 4 December 2025
- Published by American Physical Society (APS) in Physical Review A
- Vol. 112 (6)
Light statistics from large ensembles of independent two-level emitters: Classical and nonclassical effects
- 21 October 2025
- Published by American Physical Society (APS) in Physical Review A
- Vol. 112 (4)
Spin-selective coherent light scattering from ion crystals
- 21 October 2025
- Published by American Physical Society (APS) in Physical Review A
- Vol. 112 (4)
Spin-selective coherent light scattering from ion crystals
- 2 October 2025
- Published by Wolters Kluwer Health in Investigative Radiology
- Vol. 61 (6) , 395-403
Multicontrast Multiphase Intestinal Imaging Using Photon-Counting CT
Objectives: The aim of this study is to validate a 3-material decomposition algorithm for distinguishing between 2 contrast media (CM) (iodine-based and tungsten-based) and water in vivo using a commercial photon-counting CT (PCCT) unit, able to acquire 4 energy thresholds simultaneously. Materials and Methods: Six healthy rats were imaged during different CM distribution phases with both iodine-based and tungsten-based CM present in the animals, one administered orally and one intravenously. Material decomposition was used to compute quantitative contrast maps, virtual noncontrast (VNC) maps, and virtual monoenergetic images (VMI). The mean enhancement in CM-filled regions and in CM-free muscle was measured. This prospective preclinical study was conducted in accordance with the German Animal Welfare Act guidelines and with the approval of the local state animal welfare committee. Results: Iodine-filled regions were exclusively enhanced (PP<0.001) in the tungsten map. VNC maps of a 3-material decomposition received no additional enhancement by CM. VMI, incorporating both iodine and tungsten CM, of different energy levels indicated the K-edge of tungsten. Conclusions: This study successfully demonstrated the capability of PCCT combined with material decomposition to delineate 2 CM and water in rats. The contrast dynamics of the 2 CM in the vessels (aorta and vena cava) and intestines were successfully reproduced in the CM maps. VNC maps may omit the need for CT scans before contrast administration. VMI revealed distinct energy-dependent attenuation profiles of the given materials.
- 2 October 2025
- Published by Wolters Kluwer Health in Investigative Radiology
- Vol. 61 (6) , 395-403
Multicontrast Multiphase Intestinal Imaging Using Photon-Counting CT
Objectives: The aim of this study is to validate a 3-material decomposition algorithm for distinguishing between 2 contrast media (CM) (iodine-based and tungsten-based) and water in vivo using a commercial photon-counting CT (PCCT) unit, able to acquire 4 energy thresholds simultaneously. Materials and Methods: Six healthy rats were imaged during different CM distribution phases with both iodine-based and tungsten-based CM present in the animals, one administered orally and one intravenously. Material decomposition was used to compute quantitative contrast maps, virtual noncontrast (VNC) maps, and virtual monoenergetic images (VMI). The mean enhancement in CM-filled regions and in CM-free muscle was measured. This prospective preclinical study was conducted in accordance with the German Animal Welfare Act guidelines and with the approval of the local state animal welfare committee. Results: Iodine-filled regions were exclusively enhanced (PP<0.001) in the tungsten map. VNC maps of a 3-material decomposition received no additional enhancement by CM. VMI, incorporating both iodine and tungsten CM, of different energy levels indicated the K-edge of tungsten. Conclusions: This study successfully demonstrated the capability of PCCT combined with material decomposition to delineate 2 CM and water in rats. The contrast dynamics of the 2 CM in the vessels (aorta and vena cava) and intestines were successfully reproduced in the CM maps. VNC maps may omit the need for CT scans before contrast administration. VMI revealed distinct energy-dependent attenuation profiles of the given materials.
- Open Access
- 1 June 2025
- Published by IOP Publishing in New Journal of Physics
- Vol. 27 (6) , 064105
Hanbury Brown and Twiss interference of electrons in free space from independent needle tip sources
We investigate two-electron interference in free space using two laser-triggered needle tips as independent electron sources, a fermionic realisation of the landmark Hanbury Brown and Twiss interferometer. We calculate the two-electron interference pattern in a quantum path formalism taking into account the fermionic nature and the spin configuration of the electrons. We also estimate the Coulomb repulsion in the setup in a semiclassical approach. We find that antibunching resulting from Pauli’s exclusion principle and repulsion stemming from the Coulomb interaction can be clearly distinguished.
- 1 June 2025
- Published by IOP Publishing in New Journal of Physics
- Vol. 27 (6) , 064105
Open AccessHanbury Brown and Twiss interference of electrons in free space from independent needle tip sources
We investigate two-electron interference in free space using two laser-triggered needle tips as independent electron sources, a fermionic realisation of the landmark Hanbury Brown and Twiss interferometer. We calculate the two-electron interference pattern in a quantum path formalism taking into account the fermionic nature and the spin configuration of the electrons. We also estimate the Coulomb repulsion in the setup in a semiclassical approach. We find that antibunching resulting from Pauli’s exclusion principle and repulsion stemming from the Coulomb interaction can be clearly distinguished.
- Open Access
- 15 April 2025
- Published by Wolters Kluwer Health in Investigative Radiology
- Vol. 60 (12) , 855-863
Photon-Counting Computed Tomography-Based Hepatic iron Quantification Using a Tungsten-Based Contrast Agent
Objectives: This study explores the potential of quantifying hepatic iron in computed tomography (CT) scans in the presence of iodine (I)- or tungsten (W)-based contrast media (CM). Materials and Methods: Experimental work was performed on a commercial photon-counting CT system able to simultaneously acquire up to 4 spectral data sets in a single scan. We examined 2 anthropomorphic abdominal phantoms with material samples of liquid liver tissue surrogate, fat, iron, and I- or W-based CM to mimic different liver compositions in an enhanced CT scan. Iron was quantified by material decomposition of reconstructed spectral CT images. Results: Two-material decomposition based on 2 spectral data sets provided material images of iron and liver with an accuracy of 1.4 mg/mL in the iron image of CM-free samples. The presence of W affected the iron quantification: For 2 and 4 mgW/mL in the material samples, the iron concentration was overestimated ( P < 0.05) with accuracies of 2.7 and 4.7 mg/mL, respectively. Three-material decomposition based on 4 spectral data sets provided material images of iron, liver, and W, with an accuracy of 1.4 mg/mL in the images without W and 1.5 (nonsignificant difference, P > 0.07) and 1.6 mg/mL (overestimation, P > 0.03) in the iron image at 2 and 4 mgW/mL, respectively. The presence of I affected the iron quantification more than W in both 2- and 3-material decomposition: For 2 and 4 mgI/mL in the material samples, the measured iron concentration was even higher ( P < 0.05), with accuracies >18 and >37 mg/mL, respectively. Conclusions: The accuracy of iron quantification from a 3-material decomposition suggested clinically feasible detection and quantification of critical hepatic iron levels in enhanced CT scans with suitable CM. In a 2-material decomposition, severe pathology is required to detect an iron liver. W-based CM was superior to I-based CM.
- 15 April 2025
- Published by Wolters Kluwer Health in Investigative Radiology
- Vol. 60 (12) , 855-863
Open AccessPhoton-Counting Computed Tomography-Based Hepatic iron Quantification Using a Tungsten-Based Contrast Agent
Objectives: This study explores the potential of quantifying hepatic iron in computed tomography (CT) scans in the presence of iodine (I)- or tungsten (W)-based contrast media (CM). Materials and Methods: Experimental work was performed on a commercial photon-counting CT system able to simultaneously acquire up to 4 spectral data sets in a single scan. We examined 2 anthropomorphic abdominal phantoms with material samples of liquid liver tissue surrogate, fat, iron, and I- or W-based CM to mimic different liver compositions in an enhanced CT scan. Iron was quantified by material decomposition of reconstructed spectral CT images. Results: Two-material decomposition based on 2 spectral data sets provided material images of iron and liver with an accuracy of 1.4 mg/mL in the iron image of CM-free samples. The presence of W affected the iron quantification: For 2 and 4 mgW/mL in the material samples, the iron concentration was overestimated ( P < 0.05) with accuracies of 2.7 and 4.7 mg/mL, respectively. Three-material decomposition based on 4 spectral data sets provided material images of iron, liver, and W, with an accuracy of 1.4 mg/mL in the images without W and 1.5 (nonsignificant difference, P > 0.07) and 1.6 mg/mL (overestimation, P > 0.03) in the iron image at 2 and 4 mgW/mL, respectively. The presence of I affected the iron quantification more than W in both 2- and 3-material decomposition: For 2 and 4 mgI/mL in the material samples, the measured iron concentration was even higher ( P < 0.05), with accuracies >18 and >37 mg/mL, respectively. Conclusions: The accuracy of iron quantification from a 3-material decomposition suggested clinically feasible detection and quantification of critical hepatic iron levels in enhanced CT scans with suitable CM. In a 2-material decomposition, severe pathology is required to detect an iron liver. W-based CM was superior to I-based CM.
- 10 February 2025
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 134 (6) , 060201
Multipath and Multiparticle Tests of Complex versus Hypercomplex Quantum Theory
The axioms of quantum mechanics provide limited information regarding the structure of the Hilbert space, such as the underlying number system. The latter is generally regarded as complex, but generalizations of complex numbers, so-called hypercomplex numbers, cannot be ruled out in theory. Therefore, specialized experiments to test for hypercomplex quantum mechanics are needed. To date, experimental tests are limited to single-particle interference exploiting a closed phase relation in a three-path interferometer called the Peres test. The latter distinguishes complex quantum mechanics from quaternionic quantum mechanics. Here, we propose a general matrix formalism putting the Peres test on a solid mathematical ground. On this basis, we introduce multipath and multiparticle interference tests, which provide a direct probe for any dimension of the number system of quantum mechanics.
- 10 February 2025
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 134 (6) , 060201
Multipath and Multiparticle Tests of Complex versus Hypercomplex Quantum Theory
The axioms of quantum mechanics provide limited information regarding the structure of the Hilbert space, such as the underlying number system. The latter is generally regarded as complex, but generalizations of complex numbers, so-called hypercomplex numbers, cannot be ruled out in theory. Therefore, specialized experiments to test for hypercomplex quantum mechanics are needed. To date, experimental tests are limited to single-particle interference exploiting a closed phase relation in a three-path interferometer called the Peres test. The latter distinguishes complex quantum mechanics from quaternionic quantum mechanics. Here, we propose a general matrix formalism putting the Peres test on a solid mathematical ground. On this basis, we introduce multipath and multiparticle interference tests, which provide a direct probe for any dimension of the number system of quantum mechanics.
- Open Access
- 23 July 2024
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 31 (5) , 1209-1216
TEMPUS, a Timepix4-based system for the event-based detection of X-rays
TEMPUS is a new detector system being developed for photon science. It is based on the Timepix4 chip and, thus, it can be operated in two distinct modes: a photon-counting mode, which allows for conventional full-frame readout at rates up to 40 kfps; and an event-driven time-stamping mode, which allows excellent time resolution in the nanosecond regime in measurements with moderate X-ray flux. In this paper, the initial prototype, a single-chip device, is introduced, and the readout system described. Moreover, and in order to evaluate its capabilities, some tests were performed at PETRA III and ESRF for which results are also presented.
- 23 July 2024
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 31 (5) , 1209-1216
Open AccessTEMPUS, a Timepix4-based system for the event-based detection of X-rays
TEMPUS is a new detector system being developed for photon science. It is based on the Timepix4 chip and, thus, it can be operated in two distinct modes: a photon-counting mode, which allows for conventional full-frame readout at rates up to 40 kfps; and an event-driven time-stamping mode, which allows excellent time resolution in the nanosecond regime in measurements with moderate X-ray flux. In this paper, the initial prototype, a single-chip device, is introduced, and the readout system described. Moreover, and in order to evaluate its capabilities, some tests were performed at PETRA III and ESRF for which results are also presented.
- Open Access
- 14 June 2024
- Published by MDPI AG in Diagnostics
- Vol. 14 (12) , 1262
An Image-Based Prior Knowledge-Free Approach for a Multi-Material Decomposition in Photon-Counting Computed Tomography
Photon-counting CT systems generally allow for acquiring multiple spectral datasets and thus for decomposing CT images into multiple materials. We introduce a prior knowledge-free deterministic material decomposition approach for quantifying three material concentrations on a commercial photon-counting CT system based on a single CT scan. We acquired two phantom measurement series: one to calibrate and one to test the algorithm. For evaluation, we used an anthropomorphic abdominal phantom with inserts of either aqueous iodine solution, aqueous tungsten solution, or water. Material CT numbers were predicted based on a polynomial in the following parameters: Water-equivalent object diameter, object center-to-isocenter distance, voxel-to-isocenter distance, voxel-to-object center distance, and X-ray tube current. The material decomposition was performed as a generalized least-squares estimation. The algorithm provided material maps of iodine, tungsten, and water with average estimation errors of 4% in the contrast agent maps and 1% in the water map with respect to the material concentrations in the inserts. The contrast-to-noise ratio in the iodine and tungsten map was 36% and 16% compared to the noise-minimal threshold image. We were able to decompose four spectral images into iodine, tungsten, and water.
- 14 June 2024
- Published by MDPI AG in Diagnostics
- Vol. 14 (12) , 1262
Open AccessAn Image-Based Prior Knowledge-Free Approach for a Multi-Material Decomposition in Photon-Counting Computed Tomography
Photon-counting CT systems generally allow for acquiring multiple spectral datasets and thus for decomposing CT images into multiple materials. We introduce a prior knowledge-free deterministic material decomposition approach for quantifying three material concentrations on a commercial photon-counting CT system based on a single CT scan. We acquired two phantom measurement series: one to calibrate and one to test the algorithm. For evaluation, we used an anthropomorphic abdominal phantom with inserts of either aqueous iodine solution, aqueous tungsten solution, or water. Material CT numbers were predicted based on a polynomial in the following parameters: Water-equivalent object diameter, object center-to-isocenter distance, voxel-to-isocenter distance, voxel-to-object center distance, and X-ray tube current. The material decomposition was performed as a generalized least-squares estimation. The algorithm provided material maps of iodine, tungsten, and water with average estimation errors of 4% in the contrast agent maps and 1% in the water map with respect to the material concentrations in the inserts. The contrast-to-noise ratio in the iodine and tungsten map was 36% and 16% compared to the noise-minimal threshold image. We were able to decompose four spectral images into iodine, tungsten, and water.