RJRenger H. Jellema

Renger H. Jellema

*This is an algorithmically generated author record based on publicly available information.

Renger H. Jellema has a total of 84 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Sample Preparation and Biostatistics for Integrated Genomics Approaches

    by Hein Stam, Michiel Akeroyd, Hilly Menke, Renger H. Jellema, Fredoen Valianpour, Wilbert H. M. Heijne, Maurien M. A. Olsthoorn, Sabine Metzelaar, Viktor M. Boer, Carlos M. F. M. Ribeiro, et al.

    Genomics is based on the ability to determine the transcriptome, proteome, and metabolome of a cell. These technologies only have added value when they are integrated and based on robust and reproducible workflows. This chapter describes the experimental design, sampling, sample pretreatment, data evaluation, integration, and interpretation. The actual generation of the data is not covered in this chapter since it is highly depended on available equipment and infrastructure. The enormous amount of data generated by these technologies are integrated and interpreted inorder to generate leads for strain and process improvement. Biostatistics are becoming very important for the whole work flow therefore, some general recommendations how to set up experimental design and how to use biostatistics in enhancing the quality of the data and the selection of biological relevant leads for strain engineering and target identification are described.

  • Data-processing strategies for metabolomics studies

    by Margriet M.W.B. Hendriks, Fred A.Van Eeuwijk, Renger H. Jellema, Johan A. Westerhuis, Theo H. Reijmers, Huub C.J. Hoefsloot, Age K. Smilde


  • Open Access

    Quantitative metabolomics based on gas chromatography mass spectrometry: status and perspectives

    by Maud M. Koek, Renger H. Jellema, Jan van der Greef, Albert C. Tas, Thomas Hankemeier

    Metabolomics involves the unbiased quantitative and qualitative analysis of the complete set of metabolites present in cells, body fluids and tissues (the metabolome). By analyzing differences between metabolomes using biostatistics (multivariate data analysis; pattern recognition), metabolites relevant to a specific phenotypic characteristic can be identified. However, the reliability of the analytical data is a prerequisite for correct biological interpretation in metabolomics analysis. In this review the challenges in quantitative metabolomics analysis with regards to analytical as well as data preprocessing steps are discussed. Recommendations are given on how to optimize and validate comprehensive silylation-based methods from sample extraction and derivatization up to data preprocessing and how to perform quality control during metabolomics studies. The current state of method validation and data preprocessing methods used in published literature are discussed and a perspective on the future research necessary to obtain accurate quantitative data from comprehensive GC-MS data is provided.


  • Deconvolution using signal segmentation

    by Renger H. Jellema, Shaji Krishnan, Margriet M.W.B. Hendriks, Bas Muilwijk, Jack T.W.E. Vogels


  • Open Access

    Dynamic metabolomic data analysis: a tutorial review

    by A. K. Smilde, J. A. Westerhuis, H. C. J. Hoefsloot, S. Bijlsma, C. M. Rubingh, D. J. Vis, R. H. Jellema, H. Pijl, F. Roelfsema, J. van der Greef

    In metabolomics, time-resolved, dynamic or temporal data is more and more collected. The number of methods to analyze such data, however, is very limited and in most cases the dynamic nature of the data is not even taken into account. This paper reviews current methods in use for analyzing dynamic metabolomic data. Moreover, some methods from other fields of science that may be of use to analyze such dynamic metabolomics data are described in some detail. The methods are put in a general framework after providing a formal definition on what constitutes a ‘dynamic’ method. Some of the methods are illustrated with real-life metabolomics examples.


  • Top Cited Papers

    Analytical Error Reduction Using Single Point Calibration for Accurate and Precise Metabolomic Phenotyping

    by Frans M. van der Kloet, Ivana Bobeldijk, Elwin R. Verheij, Renger H. Jellema

    Analytical errors caused by suboptimal performance of the chosen platform for a number of metabolites and instrumental drift are a major issue in large-scale metabolomics studies. Especially for MS-based methods, which are gaining common ground within metabolomics, it is difficult to control the analytical data quality without the availability of suitable labeled internal standards and calibration standards even within one laboratory. In this paper, we suggest a workflow for significant reduction of the analytical error using pooled calibration samples and multiple internal standard strategy. Between and within batch calibration techniques are applied and the analytical error is reduced significantly (increase of 25% of peaks with RSD lower than 20%) and does not hamper or interfere with statistical analysis of the final data.


  • Analyzing Longitudinal Microbial Metabolomics Data

    by Carina M. Rubingh, Sabina Bijlsma, Renger H. Jellema, Karin M. Overkamp, Mariët J. van der Werf, Age K. Smilde

    A longitudinal experimental design in combination with metabolomics and multiway data analysis is a powerful approach in the identification of metabolites whose correlation with bioproduct formation shows a shift in time. In this paper, a strategy is presented for the analysis of longitudinal microbial metabolomics data, which was performed in order to identify metabolites that are likely inducers of phenylalanine production by Escherichia coli. The variation in phenylalanine production as a function of differences in metabolism induced by the different environmental conditions in time was described by a validated multiway statistical model. Notably, most of the metabolites showing the strongest relations with phenylalanine production seemed to hardly change in time. Apparently, potential bottlenecks in phenylalanine seem to hardly change in the course of a batch fermentation. The approach described in this study is not limited to longitudinal microbial studies but can also be applied to other (biological) studies in which similar longitudinal data need to be analyzed.


  • Systems Biology

    by L. Coulier, S. Wopereis, C. Rubingh, H. Hendriks, M. Radonjić, R.H. Jellema


  • PREDICTION OF TEXTURE PERCEPTION OF MAYONNAISES FROM RHEOLOGICAL AND NOVEL INSTRUMENTAL MEASUREMENTS

    by Marjolein E.J. Terpstra, Renger H. Jellema, Anke M. Janssen, René A. DE Wijk, Jon F. Prinz, Erik VAN DER Linden

    Commercial and model mayonnaises varying in fat content and type and amount of thickener were characterized by sensory analysis, rheological measurements and novel instrumental measurements covering other physicochemical properties and/or reflecting changes of food properties during oral processing. Predictions of texture attributes by rheological measurements were analyzed and compared with predictions by rheological measurements combined with novel measurements. Most of the texture attributes were predicted well by rheological parameters alone. Parameters from other instrumental measurements played a small complementary role, except in the predictions of most of the afterfeel attributes. Most important were rheometry at large deformation and in the nonlinear regime of the dynamic stress sweep and two novel measurements reflecting the effect of saliva: turbidity of rinse water and viscosity with added saliva. Tanδat 500% strain, reflecting the fluid‐like character of the samples during high‐strain dynamic flow, relates best to creaminess and other texture attributes.PRACTICAL APPLICATIONS: This article describes how and how well the texture attributes of mayonnaises can be predicted from rheological and novel instrumental measurements. It shows that many texture attributes can be successfully predicted by bulk rheological properties alone, but that for some the quality of the predictions increases slightly when parameters from other instrumental measurements, such as those from turbidity measurements, those from viscosity measurements in the structure breakdown cell with saliva, or those from friction measurements, are added. These results are relevant not only to those investigating the mechanisms involved in the oral perception of texture in semisolids but also to those who want to perform quick screening of new samples without the use of time‐consuming and expensive sensory panels. Simulations can be performed using the models to predict how texture attributes are influenced by changes in the rheological characteristics of a product. The results also identify rheological measurements and novel instrumental measurements relevant for texture attributes of mayonnaise. This knowledge may help to improve the efficiency of product development in industry.