SRStefan Riechelmann

Stefan Riechelmann

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Stefan Riechelmann has a total of 23 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • The Impact of Spectral Irradiance Aggregation Into Kato Bands and PV-Bands on Estimates of Photovoltaic Spectral Effects

    by Sophie Pelland, Stefan Riechelmann

    Full-resolution spectral irradiance data can comprise upwards of 2000–3000 data points at a single time step. Given that photovoltaic (PV) modeling is regularly performed with subhourly time resolutions over multiyear periods, incorporating spectral effects can become challenging both in terms of file sizes and computational burden. For this reason, spectral irradiances are sometimes aggregated into a limited number of wavelength bands (or wavebands), such as the 32-band grouping known as Kato bands that is used in the IEC 61853 series of standards on “PV module performance testing and energy rating.” To test the impact of such aggregation, measured, and modeled spectral irradiance data from two sites in the United States—Tempe, Arizona and Golden, Colorado—are used to assess the impact on PV spectral effect estimates of aggregating spectral irradiances into Kato bands and into two other sets of wavebands known as PV-bands. Calculations using the aggregated spectra are compared with those using the full-resolution spectra, for crystalline silicon and cadmium telluride modules. Each of the three sets of wavebands yields negligible errors of less than 0.1% in the spectral derate factor, which characterizes long-term spectral effects. This indicates that both Kato bands and PV-bands should be sufficient for the purposes of PV energy rating. Meanwhile, a recent version of PV-bands performs best for evaluating the instantaneous spectral mismatch factor, leading to errors of less than 0.2% across all time steps for both sites and PV module technologies, while instantaneous errors for Kato bands reach magnitudes of up to 1.4%.

  • Open Access

    Improved Synthesis of Global Irradiance with One-Minute Resolution for PV System Simulations

    by Martin Hofmann, Stefan Riechelmann, Cristian Crisosto, Riyad Mubarak, Gunther Seckmeyer

    High resolution global irradiance time series are needed for accurate simulations of photovoltaic (PV) systems, since the typical volatile PV power output induced by fast irradiance changes cannot be simulated properly with commonly available hourly averages of global irradiance. We present a two-step algorithm that is capable of synthesizing one-minute global irradiance time series based on hourly averaged datasets. The algorithm is initialized by deriving characteristic transition probability matrices (TPM) for different weather conditions (cloudless, broken clouds and overcast) from a large number of high resolution measurements. Once initialized, the algorithm is location-independent and capable of synthesizing one-minute values based on hourly averaged global irradiance of any desired location. The one-minute time series are derived by discrete-time Markov chains based on a TPM that matches the weather condition of the input dataset. One-minute time series generated with the presented algorithm are compared with measured high resolution data and show a better agreement compared to two existing synthesizing algorithms in terms of temporal variability and characteristic frequency distributions of global irradiance and clearness index values. A comparison based on measurements performed in Lindenberg, Germany, and Carpentras, France, shows a reduction of the frequency distribution root mean square errors of more than 60% compared to the two existing synthesizing algorithms.


  • A Novel Method to Calculate Solar UV Exposure Relevant to Vitamin D Production in Humans

    by Gunther Seckmeyer, Michael Schrempf, Anna Wieczorek, Stefan Riechelmann, Kathrin Graw, Stefan Seckmeyer, Maria Zankl

    We present a novel method to calculate vitamin D3–weighted exposure by integrating the incident solar spectral radiance over all relevant parts of the human body. Earlier investigations are based on the irradiance on surfaces, whereas our calculated exposure of a voxel model of a human takes into account the complex geometry of the radiation field. Assuming that sufficient vitamin D3 (1000 international units) can be produced within the human body in one minute for a completely uncovered body in vertical posture in summer at midlatitudes (e.g. Rome, June 21, noon, UV index of 10), we calculate the exposure times needed in other situations or seasons to gain enough vitamin D3. Our calculations show that the UV index is not a good indicator for the exposure which depends on the orientation of the body (e.g. vertical (standing) or horizontal (lying down) posture). Without clothing the exposure is dominated by diffuse sky radiation and it is nearly irrelevant how the body in vertical posture is oriented toward the sun. At the winter solstice (December 21, noon, cloudy) at least in central Europe sufficient vitamin D3 cannot be obtained with realistic clothing, even if the exposure were extended to all daylight hours.


  • Measuring high-resolution sky luminance distributions with a CCD camera

    by Korntip Tohsing, Michael Schrempf, Stefan Riechelmann, Holger Schilke, Gunther Seckmeyer

    We describe how sky luminance can be derived from a newly developed hemispherical sky imager (HSI) system. The system contains a commercial compact charge coupled device (CCD) camera equipped with a fish-eye lens. The projection of the camera system has been found to be nearly equidistant. The luminance from the high dynamic range images has been calculated and then validated with luminance data measured by a CCD array spectroradiometer. The deviation between both datasets is less than 10% for cloudless and completely overcast skies, and differs by no more than 20% for all sky conditions. The global illuminance derived from the HSI pictures deviates by less than 5% and 20% under cloudless and cloudy skies for solar zenith angles less than 80°, respectively. This system is therefore capable of measuring sky luminance with the high spatial and temporal resolution of more than a million pixels and every 20 s respectively.


  • Monte Carlo-based uncertainty analysis of UV array spectroradiometers

    by Raul R Cordero, Gunther Seckmeyer, Stefan Riechelmann, Alessandro Damiani, Fernando Labbe


  • A Critical Assessment of Two Types of Personal UV Dosimeters

    by Gunther Seckmeyer, Marcus Klingebiel, Stefan Riechelmann, Insa Lohse, Richard L. McKenzie, J. Ben Liley, Martin W. Allen, Anna‐Maria Siani, Giuseppe R. Casale

    Doses of erythemally weighted irradiances derived from polysulphone (PS) and electronic ultraviolet (EUV) dosimeters have been compared with measurements obtained using a reference spectroradiometer. PS dosimeters showed mean absolute deviations of 26% with a maximum deviation of 44%, the calibrated EUV dosimeters showed mean absolute deviations of 15% (maximum 33%) around noon during several test days in the northern hemisphere autumn. In the case of EUV dosimeters, measurements with various cut‐off filters showed that part of the deviation from the CIE erythema action spectrum was due to a small, but significant sensitivity to visible radiation that varies between devices and which may be avoided by careful preselection. Usually the method of calibrating UV sensors by direct comparison to a reference instrument leads to reliable results. However, in some circumstances the quality of measurements made with simple sensors may be over‐estimated. In the extreme case, a simple pyranometer can be used as a UV instrument, providing acceptable results for cloudless skies, but very poor results under cloudy conditions. It is concluded that while UV dosimeters are useful for their design purpose, namely to estimate personal UV exposures, they should not be regarded as an inexpensive replacement for meteorological grade instruments.