Antonín Hlaváček
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Antonín Hlaváček has a total of 111 co-authors. Here are the top co-authors by number of shared publications:
- Hans H. Gorris
Department of Biochemistry, Faculty of Science, Masaryk University, Kamenice 5, 625 00 Brno, Czech Republic
16 shared publications - Zdeněk Farka
Department of Biochemistry, Faculty of Science, Masaryk University, Brno, Czech Republic
16 shared publications - Petr Skládal
Department of Biochemistry, Faculty of Science, Masaryk University, Kamenice 5, 625 00 Brno, Czech Republic
15 shared publications - Matthias Jürgen Mickert
Institute of Analytical Chemistry, Chemo- and Biosensors, University of Regensburg, Universitätsstraße 31, 93040, Regensburg, Germany
9 shared publications Julie Weisová
Institute of Analytical Chemistry of the Czech Academy of Sciences
7 shared publicationsPetr Skládal
Department of Biochemistry, Faculty of Science, Masaryk University, Kamenice 5, 625 00 Brno, Czech Republic
6 shared publications
Latest Publications
- Open Access
- 24 June 2025
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 97 (26) , 13832-13839
Digital Immunoassay for Biomarker Detection Based on Single-Particle Laser Ablation ICP MS
Single-particle (digital) immunoassays offer significantly lower limits of detection (LODs) than traditional immunoassays, making them suitable for the detection of low-abundance biomarkers. The most common approach for digital detection is based on counting individual labels. Here, we introduce a novel dot-blot particle-linked immunosorbent assay (PLISA) with digital readout utilizing laser ablation (LA) of photon upconversion nanoparticle (UCNP) labels from the nitrocellulose substrate. Compared to conventional LA, our approach allows desorption of intact nanoparticles and their precise counting by single-particle inductively coupled plasma mass spectrometry (SP ICP MS), thus counting individual UCNP-labeled immunocomplexes. Digital signal processing filters instrument noise and nanoparticle aggregates, minimizing potential errors. The immunoassay and LA SP ICP MS readout were optimized using human serum albumin, a kidney damage biomarker, as a model analyte, obtaining LODs of 0.18 and 0.12 ng/mL for the reference upconversion luminescence (UCL) and LA SP ICP MS readout, respectively. Building upon these optimized conditions, we developed PLISA for prostate-specific antigen, the key prostate cancer biomarker, with LODs of 2.4, 1.4, and 0.3 pg/mL for the UCL, analog, and digital LA SP ICP MS readout, respectively. The LOD in the sub-pg/mL range highlighted the advantage of particle counting and its ability to detect low-abundance biomarkers, as superior performance was achieved compared to the UCL and analog LA ICP MS readout. Finally, clinical serum samples of patients tested for prostate cancer were analyzed, and a strong correlation with the reference electrochemiluminescence method confirmed the potential of LA SP ICP MS for clinical diagnostics.
- 24 June 2025
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 97 (26) , 13832-13839
Open AccessDigital Immunoassay for Biomarker Detection Based on Single-Particle Laser Ablation ICP MS
Single-particle (digital) immunoassays offer significantly lower limits of detection (LODs) than traditional immunoassays, making them suitable for the detection of low-abundance biomarkers. The most common approach for digital detection is based on counting individual labels. Here, we introduce a novel dot-blot particle-linked immunosorbent assay (PLISA) with digital readout utilizing laser ablation (LA) of photon upconversion nanoparticle (UCNP) labels from the nitrocellulose substrate. Compared to conventional LA, our approach allows desorption of intact nanoparticles and their precise counting by single-particle inductively coupled plasma mass spectrometry (SP ICP MS), thus counting individual UCNP-labeled immunocomplexes. Digital signal processing filters instrument noise and nanoparticle aggregates, minimizing potential errors. The immunoassay and LA SP ICP MS readout were optimized using human serum albumin, a kidney damage biomarker, as a model analyte, obtaining LODs of 0.18 and 0.12 ng/mL for the reference upconversion luminescence (UCL) and LA SP ICP MS readout, respectively. Building upon these optimized conditions, we developed PLISA for prostate-specific antigen, the key prostate cancer biomarker, with LODs of 2.4, 1.4, and 0.3 pg/mL for the UCL, analog, and digital LA SP ICP MS readout, respectively. The LOD in the sub-pg/mL range highlighted the advantage of particle counting and its ability to detect low-abundance biomarkers, as superior performance was achieved compared to the UCL and analog LA ICP MS readout. Finally, clinical serum samples of patients tested for prostate cancer were analyzed, and a strong correlation with the reference electrochemiluminescence method confirmed the potential of LA SP ICP MS for clinical diagnostics.
- Open Access
- 15 June 2025
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 97 (25) , 12940-12946
A Method for Determination of Transport Efficiency in Laser Ablation Inductively Coupled Plasma Mass Spectrometry for Tissue Analysis
Recent studies have demonstrated the applicability of the "single particle" mode in laser ablation-inductively coupled plasma-mass spectrometry to map and size particles simultaneously. The transport efficiency (TE) is an important parameter in this configuration and affects the detection of individual nanoparticles, reliability of nanoparticle characterization, and related applications. This study introduces a novel method for the precise determination of TE, based on counting upconversion nanoparticles from gels characterized by fluorescent microscopy. The method was found to be most suitable for the 2940-nm laser ablation system, achieving virtually quantitative nanoparticle desorption, with TE primarily governed by ablation cell design and aerosol transport efficiency. With the 213-nm laser, attention had to be paid to incomplete desorption and possible nanoparticle redeposition at low laser fluences to avoid variability in TE measurements. Finally, use of the 193-nm laser-induced nanoparticle disintegration, resulting in elevated baseline noise and lower sensitivity, which prevented the use of this approach for the determination of TE. This study highlights the versatility of the proposed method, while also identifying its limitations, in terms of wavelength and fluence.
- 15 June 2025
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 97 (25) , 12940-12946
Open AccessA Method for Determination of Transport Efficiency in Laser Ablation Inductively Coupled Plasma Mass Spectrometry for Tissue Analysis
Recent studies have demonstrated the applicability of the "single particle" mode in laser ablation-inductively coupled plasma-mass spectrometry to map and size particles simultaneously. The transport efficiency (TE) is an important parameter in this configuration and affects the detection of individual nanoparticles, reliability of nanoparticle characterization, and related applications. This study introduces a novel method for the precise determination of TE, based on counting upconversion nanoparticles from gels characterized by fluorescent microscopy. The method was found to be most suitable for the 2940-nm laser ablation system, achieving virtually quantitative nanoparticle desorption, with TE primarily governed by ablation cell design and aerosol transport efficiency. With the 213-nm laser, attention had to be paid to incomplete desorption and possible nanoparticle redeposition at low laser fluences to avoid variability in TE measurements. Finally, use of the 193-nm laser-induced nanoparticle disintegration, resulting in elevated baseline noise and lower sensitivity, which prevented the use of this approach for the determination of TE. This study highlights the versatility of the proposed method, while also identifying its limitations, in terms of wavelength and fluence.
- Open Access
- 19 May 2025
- Published by American Chemical Society (ACS) in Langmuir
- Vol. 41 (21) , 13126-13133
The Application of Anisotropically Collapsing Gels, Deep Learning, and Optical Microscopy for Chemical Characterization of Nanoparticles and Nanoplastics
The surface chemistry of nanomaterials, particularly the density of functional groups, governs their behavior in applications such as bioanalysis, bioimaging, and environmental impact studies. Here, we report a precise method to quantify carboxyl groups per nanoparticle by combining anisotropically collapsing agarose gels for nanoparticle immobilization with fluorescence microscopy and acid-base titration. We applied this approach to photon-upconversion nanoparticles (UCNPs) coated with poly(acrylic acid) (PAA) and fluorescence-labeled polystyrene nanoparticles (PNs), which serve as models for bioimaging and environmental pollutants, respectively. UCNPs exhibited 152 ± 14 thousand carboxyl groups per particle (∼11 groups/nm2), while PNs were characterized with 38 ± 3.6 thousand groups (∼1.7 groups/nm2). The limit of detection was 6.4 and 1.9 thousand carboxyl groups per nanoparticle, and the limit of quantification was determined at 21 and 6.2 thousand carboxyl groups per nanoparticle for UCNP-PAAs and PNs, respectively. High intrinsic luminescence enabled direct imaging of UCNPs, while PNs required fluorescence staining with Nile Red to overcome low signal-to-noise ratios. The study also discussed the critical influence of nanoparticle concentration and titration conditions on the assay performance. This method advances the precise characterization of surface chemistry, offering insights into nanoparticle structure that extend beyond the resolution of electron microscopy. Our findings establish a robust platform for investigating the interplay of surface chemistry with nanoparticle function and fate in technological and environmental contexts, with broad applicability across nanomaterials.
- 19 May 2025
- Published by American Chemical Society (ACS) in Langmuir
- Vol. 41 (21) , 13126-13133
Open AccessThe Application of Anisotropically Collapsing Gels, Deep Learning, and Optical Microscopy for Chemical Characterization of Nanoparticles and Nanoplastics
The surface chemistry of nanomaterials, particularly the density of functional groups, governs their behavior in applications such as bioanalysis, bioimaging, and environmental impact studies. Here, we report a precise method to quantify carboxyl groups per nanoparticle by combining anisotropically collapsing agarose gels for nanoparticle immobilization with fluorescence microscopy and acid-base titration. We applied this approach to photon-upconversion nanoparticles (UCNPs) coated with poly(acrylic acid) (PAA) and fluorescence-labeled polystyrene nanoparticles (PNs), which serve as models for bioimaging and environmental pollutants, respectively. UCNPs exhibited 152 ± 14 thousand carboxyl groups per particle (∼11 groups/nm2), while PNs were characterized with 38 ± 3.6 thousand groups (∼1.7 groups/nm2). The limit of detection was 6.4 and 1.9 thousand carboxyl groups per nanoparticle, and the limit of quantification was determined at 21 and 6.2 thousand carboxyl groups per nanoparticle for UCNP-PAAs and PNs, respectively. High intrinsic luminescence enabled direct imaging of UCNPs, while PNs required fluorescence staining with Nile Red to overcome low signal-to-noise ratios. The study also discussed the critical influence of nanoparticle concentration and titration conditions on the assay performance. This method advances the precise characterization of surface chemistry, offering insights into nanoparticle structure that extend beyond the resolution of electron microscopy. Our findings establish a robust platform for investigating the interplay of surface chemistry with nanoparticle function and fate in technological and environmental contexts, with broad applicability across nanomaterials.
- Open Access
- 31 March 2025
- Published by Royal Society of Chemistry (RSC) in Nanoscale
- Vol. 17 (18) , 11401-11412
Bioconjugates of photon-upconversion nanoparticles with antibodies for the detection of prostate-specific antigen and p53 in heterogeneous and homogeneous immunoassays
Sensitive immunoassays for the detection of tumor biomarkers play an important role in early diagnosis and therapy of cancer. Using luminescent nanomaterials as labels can significantly improve immunoassay performance, especially in terms of sensitivity. Lanthanide-doped photon-upconversion nanoparticles (UCNPs) are nanocrystals capable of converting near-infrared radiation into visible light, and their emission spectra can be tuned by altering the dopant ions. In this study, the bioconjugation between UCNPs and biomolecules was optimized, and different conjugates of Er- and Tm-doped UCNPs (NaYF4:Yb3+,Er3+ and NaYF4:Yb3+,Tm3+) were prepared for detecting prostate-specific antigen (PSA) and tumor protein p53, comparing heterogeneous and homogeneous assay formats. The heterogeneous sandwich immunoassay achieved detection limits of 1.3 pg/mL of PSA and 330 pg/mL of p53. The homogeneous immunoassays were based on massively parallel spectroscopy (MPS), a novel artificial intelligence-aided single-molecule approach, utilizing conjugates of two different monoclonal antibodies with Er- and Tm-doped UCNPs, respectively. The conjugates provide distinct emission spectra, with only sandwich immunocomplexes of analyte and both types of labels showing both signals at the same location. The MPS-based immunoassay was suitable for observing the immunocomplexes in an aqueous dispersion using only a small sample volume. This innovative method achieved detection limits of 8.2 ng/mL and 390 pg/mL for PSA and p53, respectively. MPS eliminates the need for time-consuming washing steps required in heterogeneous immunoassays and is amenable to high-throughput applications.
- 31 March 2025
- Published by Royal Society of Chemistry (RSC) in Nanoscale
- Vol. 17 (18) , 11401-11412
Open AccessBioconjugates of photon-upconversion nanoparticles with antibodies for the detection of prostate-specific antigen and p53 in heterogeneous and homogeneous immunoassays
Sensitive immunoassays for the detection of tumor biomarkers play an important role in early diagnosis and therapy of cancer. Using luminescent nanomaterials as labels can significantly improve immunoassay performance, especially in terms of sensitivity. Lanthanide-doped photon-upconversion nanoparticles (UCNPs) are nanocrystals capable of converting near-infrared radiation into visible light, and their emission spectra can be tuned by altering the dopant ions. In this study, the bioconjugation between UCNPs and biomolecules was optimized, and different conjugates of Er- and Tm-doped UCNPs (NaYF4:Yb3+,Er3+ and NaYF4:Yb3+,Tm3+) were prepared for detecting prostate-specific antigen (PSA) and tumor protein p53, comparing heterogeneous and homogeneous assay formats. The heterogeneous sandwich immunoassay achieved detection limits of 1.3 pg/mL of PSA and 330 pg/mL of p53. The homogeneous immunoassays were based on massively parallel spectroscopy (MPS), a novel artificial intelligence-aided single-molecule approach, utilizing conjugates of two different monoclonal antibodies with Er- and Tm-doped UCNPs, respectively. The conjugates provide distinct emission spectra, with only sandwich immunocomplexes of analyte and both types of labels showing both signals at the same location. The MPS-based immunoassay was suitable for observing the immunocomplexes in an aqueous dispersion using only a small sample volume. This innovative method achieved detection limits of 8.2 ng/mL and 390 pg/mL for PSA and p53, respectively. MPS eliminates the need for time-consuming washing steps required in heterogeneous immunoassays and is amenable to high-throughput applications.
- Open Access
- 31 January 2025
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 97 (5) , 2588-2592
Optical Microscopy and Deep Learning for Absolute Quantification of Nanoparticles on a Macroscopic Scale and Estimating Their Number Concentration
We present a simplistic and absolute method for estimating the number concentration of nanoparticles. Macroscopic volumes of a nanoparticle dispersion (several μL) are dropped on a glass surface and the solvent is evaporated. The optical microscope scans the entire surface of the dried droplet (several mm2), micrographs are stitched together (several tens), and all nanoparticles are counted (several thousand per droplet) by using an artificial neural network. We call this method evaporated volume analysis (EVA) because nanoparticles are counted after droplet volume evaporation. As a model, the concentration of ∼60 nm Tm3+-doped photon-upconversion nanoparticles coated in carboxylated silica shells is estimated with a combined relative standard uncertainty of 2.7%. Two reference methods provided comparable concentration values. A wider applicability is tested by imaging ∼80 nm Nile red-doped polystyrene and ∼90 nm silver nanoparticles. Theoretical limits of EVA such as the limit of detection, limit of quantification, and optimal working range are discussed.
- 31 January 2025
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 97 (5) , 2588-2592
Open AccessOptical Microscopy and Deep Learning for Absolute Quantification of Nanoparticles on a Macroscopic Scale and Estimating Their Number Concentration
We present a simplistic and absolute method for estimating the number concentration of nanoparticles. Macroscopic volumes of a nanoparticle dispersion (several μL) are dropped on a glass surface and the solvent is evaporated. The optical microscope scans the entire surface of the dried droplet (several mm2), micrographs are stitched together (several tens), and all nanoparticles are counted (several thousand per droplet) by using an artificial neural network. We call this method evaporated volume analysis (EVA) because nanoparticles are counted after droplet volume evaporation. As a model, the concentration of ∼60 nm Tm3+-doped photon-upconversion nanoparticles coated in carboxylated silica shells is estimated with a combined relative standard uncertainty of 2.7%. Two reference methods provided comparable concentration values. A wider applicability is tested by imaging ∼80 nm Nile red-doped polystyrene and ∼90 nm silver nanoparticles. Theoretical limits of EVA such as the limit of detection, limit of quantification, and optimal working range are discussed.
- Open Access
- 24 June 2024
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 24 (14) , 3536-3545
Single-molecule microfluidic assay for prostate-specific antigen based on magnetic beads and upconversion nanoparticles
A microfluidic device for single-molecule detection of prostate-specific antigen was developed, utilizing magnetic microparticles as a solid phase and photon-upconversion nanoparticles as a label.
- 24 June 2024
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 24 (14) , 3536-3545
Open AccessSingle-molecule microfluidic assay for prostate-specific antigen based on magnetic beads and upconversion nanoparticles
A microfluidic device for single-molecule detection of prostate-specific antigen was developed, utilizing magnetic microparticles as a solid phase and photon-upconversion nanoparticles as a label.
- Open Access
- 13 June 2024
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 96 (25) , 10237-10245
Upconversion Nanoparticle-Based Dot-Blot Immunoassay for Quantitative Biomarker Detection
Dot-blot immunoassays are widely used for the user-friendly detection of clinical biomarkers. However, the majority of dot-blot assays have only limited sensitivity and are only used for qualitative or semiquantitative analysis. To overcome this limitation, we have employed labels based on photon-upconversion nanoparticles (UCNPs) that exhibit anti-Stokes luminescence and can be detected without optical background interference. First, the dot-blot immunoassay on a nitrocellulose membrane was optimized for the quantitative analysis of human serum albumin (HSA), resulting in a limit of detection (LOD) of 0.19 ng/mL and a signal-to-background ratio (S/B) of 722. Commercial quantum dots were used as a reference label, reaching the LOD of 4.32 ng/mL and the S/B of 3, clearly indicating the advantages of UCNPs. In addition, the potential of UCNP-based dot-blot for real sample analysis was confirmed by analyzing spiked urine samples, reaching the LOD of 0.24 ng/mL and recovery rates from 79 to 123%. Furthermore, we demonstrated the versatility and robustness of the assay by adapting it to the detection of two other clinically relevant biomarkers, prostate-specific antigen (PSA) and cardiac troponin (cTn), reaching the LODs in spiked serum of 9.4 pg/mL and 0.62 ng/mL for PSA and cTn, respectively. Finally, clinical samples of patients examined for prostate cancer were analyzed, achieving a strong correlation with the reference electrochemiluminescence immunoassay (recovery rates from 89 to 117%). The achieved results demonstrate that UCNPs are highly sensitive labels that enable the development of dot-blot immunoassays for quantitative analysis of low-abundance biomarkers.
- 13 June 2024
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 96 (25) , 10237-10245
Open AccessUpconversion Nanoparticle-Based Dot-Blot Immunoassay for Quantitative Biomarker Detection
Dot-blot immunoassays are widely used for the user-friendly detection of clinical biomarkers. However, the majority of dot-blot assays have only limited sensitivity and are only used for qualitative or semiquantitative analysis. To overcome this limitation, we have employed labels based on photon-upconversion nanoparticles (UCNPs) that exhibit anti-Stokes luminescence and can be detected without optical background interference. First, the dot-blot immunoassay on a nitrocellulose membrane was optimized for the quantitative analysis of human serum albumin (HSA), resulting in a limit of detection (LOD) of 0.19 ng/mL and a signal-to-background ratio (S/B) of 722. Commercial quantum dots were used as a reference label, reaching the LOD of 4.32 ng/mL and the S/B of 3, clearly indicating the advantages of UCNPs. In addition, the potential of UCNP-based dot-blot for real sample analysis was confirmed by analyzing spiked urine samples, reaching the LOD of 0.24 ng/mL and recovery rates from 79 to 123%. Furthermore, we demonstrated the versatility and robustness of the assay by adapting it to the detection of two other clinically relevant biomarkers, prostate-specific antigen (PSA) and cardiac troponin (cTn), reaching the LODs in spiked serum of 9.4 pg/mL and 0.62 ng/mL for PSA and cTn, respectively. Finally, clinical samples of patients examined for prostate cancer were analyzed, achieving a strong correlation with the reference electrochemiluminescence immunoassay (recovery rates from 89 to 117%). The achieved results demonstrate that UCNPs are highly sensitive labels that enable the development of dot-blot immunoassays for quantitative analysis of low-abundance biomarkers.
- Open Access
- 8 August 2023
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 95 (33) , 12256-12263
Artificial Intelligence-Aided Massively Parallel Spectroscopy of Freely Diffusing Nanoscale Entities
Massively parallel spectroscopy (MPS) of many single nanoparticles in an aqueous dispersion is reported. As a model system, bioconjugated photon-upconversion nanoparticles (UCNPs) with a near-infrared excitation are prepared. The UCNPs are doped either with Tm3+ (emission 450 and 802 nm) or Er3+ (emission 554 and 660 nm). These UCNPs are conjugated to biotinylated bovine serum albumin (Tm3+-doped) or streptavidin (Er3+-doped). MPS is correlated with an ensemble spectra measurement, and the limit of detection (1.6 fmol L-1) and the linearity range (4.8 fmol L-1 to 40 pmol L-1) for bioconjugated UCNPs are estimated. MPS is used for observing the bioaffinity clustering of bioconjugated UCNPs. This observation is correlated with a native electrophoresis and bioaffinity assay on a microtiter plate. A competitive MPS bioaffinity assay for biotin is developed and characterized with a limit of detection of 6.6 nmol L-1. MPS from complex biological matrices (cell cultivation medium) is performed without increasing background. The compatibility with polydimethylsiloxane microfluidics is proven by recording MPS from a 30 μm deep microfluidic channel.
- 8 August 2023
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 95 (33) , 12256-12263
Open AccessArtificial Intelligence-Aided Massively Parallel Spectroscopy of Freely Diffusing Nanoscale Entities
Massively parallel spectroscopy (MPS) of many single nanoparticles in an aqueous dispersion is reported. As a model system, bioconjugated photon-upconversion nanoparticles (UCNPs) with a near-infrared excitation are prepared. The UCNPs are doped either with Tm3+ (emission 450 and 802 nm) or Er3+ (emission 554 and 660 nm). These UCNPs are conjugated to biotinylated bovine serum albumin (Tm3+-doped) or streptavidin (Er3+-doped). MPS is correlated with an ensemble spectra measurement, and the limit of detection (1.6 fmol L-1) and the linearity range (4.8 fmol L-1 to 40 pmol L-1) for bioconjugated UCNPs are estimated. MPS is used for observing the bioaffinity clustering of bioconjugated UCNPs. This observation is correlated with a native electrophoresis and bioaffinity assay on a microtiter plate. A competitive MPS bioaffinity assay for biotin is developed and characterized with a limit of detection of 6.6 nmol L-1. MPS from complex biological matrices (cell cultivation medium) is performed without increasing background. The compatibility with polydimethylsiloxane microfluidics is proven by recording MPS from a 30 μm deep microfluidic channel.
- 16 November 2022
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 94 (47) , 16376-16383
Influence of Label and Solid Support on the Performance of Heterogeneous Immunoassays
Conventional immunochemical methods used in clinical analysis are often not sensitive enough for early-stage diagnosis, resulting in the need for novel assay formats. Here, we provide a detailed comparison of the effect of different labels and solid supports on the performance of heterogeneous immunoassays. When comparing three types of streptavidin-modified labels─horseradish peroxidase, carboxyfluorescein, and photon-upconversion nanoparticles (UCNPs)─UCNPs led to the most sensitive and robust detection of the cancer biomarker prostate-specific antigen. Additionally, we compared the immunoassay formats based on conventional microtiter plates and magnetic microbeads (MBs). In both cases, the highest signal-to-background ratios and the lowest limits of detection (LODs) were obtained by using the UCNP labels. The MB-based upconversion-linked immunosorbent assay carried out with a preconcentration step provided the lowest LOD of 0.46 pg/mL in serum. The results demonstrate that the use of UCNPs and MBs can significantly improve the sensitivity and working range of heterogeneous immunoassays for biomarker detection.
- 16 November 2022
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 94 (47) , 16376-16383
Influence of Label and Solid Support on the Performance of Heterogeneous Immunoassays
Conventional immunochemical methods used in clinical analysis are often not sensitive enough for early-stage diagnosis, resulting in the need for novel assay formats. Here, we provide a detailed comparison of the effect of different labels and solid supports on the performance of heterogeneous immunoassays. When comparing three types of streptavidin-modified labels─horseradish peroxidase, carboxyfluorescein, and photon-upconversion nanoparticles (UCNPs)─UCNPs led to the most sensitive and robust detection of the cancer biomarker prostate-specific antigen. Additionally, we compared the immunoassay formats based on conventional microtiter plates and magnetic microbeads (MBs). In both cases, the highest signal-to-background ratios and the lowest limits of detection (LODs) were obtained by using the UCNP labels. The MB-based upconversion-linked immunosorbent assay carried out with a preconcentration step provided the lowest LOD of 0.46 pg/mL in serum. The results demonstrate that the use of UCNPs and MBs can significantly improve the sensitivity and working range of heterogeneous immunoassays for biomarker detection.
- 4 October 2022
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 94 (41) , 14340-14348
Absolute Counting Method with Multiplexing Capability for Estimating the Number Concentration of Nanoparticles Using Anisotropically Collapsed Gels
Number concentration─the number of nanoparticles in a given volume─is an important characteristic of any nanoparticle dispersion. However, its estimation for small nanoparticles (∼30 nm) is generally challenging. We introduce an absolute and widely applicable method for analyzing aqueous dispersions of nanoparticles. An innovative immobilization of nanomaterials in the anisotropically collapsed agarose gel is pioneered, followed by optical microscopy and nanoparticle counting. The number of counted nanoparticles is inherently coupled with sampled volume (517 pL) and translates to the number concentration. Photon-upconversion, fluorescence, bright-field, and dark-field microscopy techniques have been proven applicable and used for imaging lanthanide-doped photon-upconversion nanoparticles, their bioconjugates with antibodies, silica dye-doped fluorescent nanoparticles, quantum dots, and pure silica submicron particles. The precision and linearity were characterized by constructing a dilution series of photon-upconversion nanoparticles. The limit of detection was 2.0 × 106 mL-1, and the working range was from 4.4 × 107 to 2.2 × 1010 mL-1. The quantification of nanoparticle clusters was achieved by a thorough analysis of the micrographs. The accuracy was confirmed using gravimetric analysis and transmission electron microscopy as a reference. Multiplexed detection of two nanoparticle types in a mixed dispersion was feasibly demonstrated. The low thickness of the collapsed gel (3+-doped photon-upconversion nanoparticles (17 nm hydrodynamic diameter) with a nanoparticle emission rate of only ∼900 photons/s at a wavelength of 800 nm (excitation wavelength 976 nm).
- 4 October 2022
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 94 (41) , 14340-14348
Absolute Counting Method with Multiplexing Capability for Estimating the Number Concentration of Nanoparticles Using Anisotropically Collapsed Gels
Number concentration─the number of nanoparticles in a given volume─is an important characteristic of any nanoparticle dispersion. However, its estimation for small nanoparticles (∼30 nm) is generally challenging. We introduce an absolute and widely applicable method for analyzing aqueous dispersions of nanoparticles. An innovative immobilization of nanomaterials in the anisotropically collapsed agarose gel is pioneered, followed by optical microscopy and nanoparticle counting. The number of counted nanoparticles is inherently coupled with sampled volume (517 pL) and translates to the number concentration. Photon-upconversion, fluorescence, bright-field, and dark-field microscopy techniques have been proven applicable and used for imaging lanthanide-doped photon-upconversion nanoparticles, their bioconjugates with antibodies, silica dye-doped fluorescent nanoparticles, quantum dots, and pure silica submicron particles. The precision and linearity were characterized by constructing a dilution series of photon-upconversion nanoparticles. The limit of detection was 2.0 × 106 mL-1, and the working range was from 4.4 × 107 to 2.2 × 1010 mL-1. The quantification of nanoparticle clusters was achieved by a thorough analysis of the micrographs. The accuracy was confirmed using gravimetric analysis and transmission electron microscopy as a reference. Multiplexed detection of two nanoparticle types in a mixed dispersion was feasibly demonstrated. The low thickness of the collapsed gel (3+-doped photon-upconversion nanoparticles (17 nm hydrodynamic diameter) with a nanoparticle emission rate of only ∼900 photons/s at a wavelength of 800 nm (excitation wavelength 976 nm).