Brian Zahler Bentz
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Brian Zahler Bentz has a total of 98 co-authors. Here are the top co-authors by number of shared publications:
Albuquerque Sandia National Laboratories (Snl-Nm)
14 shared publicationsKevin Youngman
Sandia National Laboratories
12 shared publicationsKarl Westlake
Sandia Natl Labs, Albuquerque, NM 87123 USA
7 shared publications- Matthew M. Hopkins
Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States)
7 shared publications Brian J. Redman
Sandia Natl Labs, Albuquerque, NM 87123 USA
6 shared publications- Jeremy Benjamin Wright
Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)
6 shared publications
Latest Publications
- Open Access
- 6 November 2026
- Published by IOP Publishing in Plasma Sources Science and Technology
Counter-propagating opposite polarity guided streamer interactions: EFISH electric fields, propagation thresholds, and memory effects
Interactions between counter-propagating guided streamers are important in multi-jet atmospheric pressure plasma jet (APPJ) systems used to extend plasma treatment over larger areas and complex three-dimensional targets. Here, two geometrically identical helium APPJs are operated in ambient air with opposite polarity and independently controlled voltages, and their interactions are investigated using time-gated ICCD imaging and electric-field-induced second harmonic (EFISH) generation. We found that the voltage of the positive polarity jet required for streamer head merging decreases as the magnitude of the negative polarity jet voltage increases, showing that the presence of the opposing streamer strongly modifies the environment governing positive streamer propagation. Reducing the pulse repetition rate from 5 kHz to 50 Hz increases the voltage required for the positive streamer to form and reduces the positive streamer’s propagation distance, consistent with reduced memory effects. However, enhanced propagation persists at low repetition rates when the negative jet is present, consistent with an increasing relative importance of streamer interaction driven effects as memory effects weaken. Measurements of EFISH electric fields provide direct benchmarks for these opposite polarity guided streamer interactions. When the fields during dual-jet operation are compared to single-jet operation, the peak field at the positive guided streamer head is unchanged within the uncertainty of the diagnostic, whereas the field distribution ahead of the peak is elongated and approximately doubled by the presence of the negative guided streamer.
- 6 November 2026
- Published by IOP Publishing in Plasma Sources Science and Technology
Open AccessCounter-propagating opposite polarity guided streamer interactions: EFISH electric fields, propagation thresholds, and memory effects
Interactions between counter-propagating guided streamers are important in multi-jet atmospheric pressure plasma jet (APPJ) systems used to extend plasma treatment over larger areas and complex three-dimensional targets. Here, two geometrically identical helium APPJs are operated in ambient air with opposite polarity and independently controlled voltages, and their interactions are investigated using time-gated ICCD imaging and electric-field-induced second harmonic (EFISH) generation. We found that the voltage of the positive polarity jet required for streamer head merging decreases as the magnitude of the negative polarity jet voltage increases, showing that the presence of the opposing streamer strongly modifies the environment governing positive streamer propagation. Reducing the pulse repetition rate from 5 kHz to 50 Hz increases the voltage required for the positive streamer to form and reduces the positive streamer’s propagation distance, consistent with reduced memory effects. However, enhanced propagation persists at low repetition rates when the negative jet is present, consistent with an increasing relative importance of streamer interaction driven effects as memory effects weaken. Measurements of EFISH electric fields provide direct benchmarks for these opposite polarity guided streamer interactions. When the fields during dual-jet operation are compared to single-jet operation, the peak field at the positive guided streamer head is unchanged within the uncertainty of the diagnostic, whereas the field distribution ahead of the peak is elongated and approximately doubled by the presence of the negative guided streamer.
- 1 October 2026
- Published by Office of Scientific and Technical Information (OSTI)
Project Final Report: Reconstruction of Density and Porosity Distribution in Explosive Materials from Incoherent Light and Speckle Correlation Measurements
This report summarizes a three year LDRD effort to develop laser microscopy methods for non- destructive characterization of the internal microstructure of energetic composites.
- 1 October 2026
- Published by Office of Scientific and Technical Information (OSTI)
Project Final Report: Reconstruction of Density and Porosity Distribution in Explosive Materials from Incoherent Light and Speckle Correlation Measurements
This report summarizes a three year LDRD effort to develop laser microscopy methods for non- destructive characterization of the internal microstructure of energetic composites.
- Open Access
- 1 October 2025
- Published by Office of Scientific and Technical Information (OSTI)
Measuring the effect of secondary electron emission on the decay of temporal sheath perturbations
- 1 October 2025
- Published by Office of Scientific and Technical Information (OSTI)
Open AccessMeasuring the effect of secondary electron emission on the decay of temporal sheath perturbations
- 1 May 2025
- Published by Office of Scientific and Technical Information (OSTI)
Multidimensional Optical Diagnostics
- 1 May 2025
- Published by Office of Scientific and Technical Information (OSTI)
Multidimensional Optical Diagnostics
- Open Access
- 1 February 2025
- Published by IOP Publishing in Plasma Sources Science and Technology
- Vol. 34 (2) , 025007
Electron density measurements and calculations in a helium capacitively-coupled radio-frequency plasma
We report a comparison of inferred electron density ( n e ) in a He capacitively-coupled plasma, deduced from laser-collision induced fluorescence measurements, with values computed using a hybrid simulation framework based on particle-in-cell/Monte Carlo collisions simulations and a fluid model for excited He atoms. The studies were carried out for gas pressures between 50 mTorr and 1000 mTorr and peak-to-peak radio-frequency (13.56 MHz) voltages between 150 V and 350 V, in a highly symmetric source equipped with plane-parallel electrodes. A good agreement is found between the experimental and modeling results for n e except at the lowest operating voltages and gas pressures. The (effective) electron temperature ( T e ) values derived by the two methods agree as well reasonably within the plasma bulk. The simulation results are used to compare the density distributions of He+ and various He excited levels and their major populating and de-populating channels at 100 mTorr and 1000 mTorr.
- 1 February 2025
- Published by IOP Publishing in Plasma Sources Science and Technology
- Vol. 34 (2) , 025007
Open AccessElectron density measurements and calculations in a helium capacitively-coupled radio-frequency plasma
We report a comparison of inferred electron density ( n e ) in a He capacitively-coupled plasma, deduced from laser-collision induced fluorescence measurements, with values computed using a hybrid simulation framework based on particle-in-cell/Monte Carlo collisions simulations and a fluid model for excited He atoms. The studies were carried out for gas pressures between 50 mTorr and 1000 mTorr and peak-to-peak radio-frequency (13.56 MHz) voltages between 150 V and 350 V, in a highly symmetric source equipped with plane-parallel electrodes. A good agreement is found between the experimental and modeling results for n e except at the lowest operating voltages and gas pressures. The (effective) electron temperature ( T e ) values derived by the two methods agree as well reasonably within the plasma bulk. The simulation results are used to compare the density distributions of He+ and various He excited levels and their major populating and de-populating channels at 100 mTorr and 1000 mTorr.
- Open Access
- 1 December 2024
- Published by IOP Publishing in Plasma Sources Science and Technology
- Vol. 33 (12) , 125007
Measurement of atomic oxygen densities using TALIF on a dielectric barrier discharge: insights into the volume above a micro cavity plasma array
Dielectric barrier discharges, particularly micro cavity plasma arrays, offer significant potential for plasma-catalytic research due to their ability to ignite plasma in direct contact with a catalytic surface, enabling the observation of plasma-surface interactions. A key factor in their application is the generation of reactive species, such as atomic oxygen, within the cavities. These species can interact with both the surface (e.g. for activation or cleaning) and the gas being treated (e.g. for oxidation). Given the central role of oxygen atoms in plasma catalysis and their use as a model for more complex species, this work investigates the transport of these atoms out of the cavities. Two-photon absorption laser-induced fluorescence spectroscopy with picosecond laser excitation is performed in the volume above the cavities. The results are compared with a basic diffusion model. The reactor operates with a He/O2 mixture at a flow rate of 1 slm and atmospheric pressure. Densities of up to 1016 cm−3 are measured near the surface. Time-dependent measurements show that, at a distance of 350 µm from the surface, a density equilibrium is reached within less than 3 ms of reactor operation. Decay times due to ozone formation after the reactor is turned off are on a similar scale. Spatially resolved measurements show that the oxygen density decreases exponentially from the surface but remains detectable up to approximately 1 mm above the surface, indicating significant application potential. Variations in the O2 admixture show a density maximum at 0.4%, confirming previous helium state enhanced actinometry measurements within the cavities.
- 1 December 2024
- Published by IOP Publishing in Plasma Sources Science and Technology
- Vol. 33 (12) , 125007
Open AccessMeasurement of atomic oxygen densities using TALIF on a dielectric barrier discharge: insights into the volume above a micro cavity plasma array
Dielectric barrier discharges, particularly micro cavity plasma arrays, offer significant potential for plasma-catalytic research due to their ability to ignite plasma in direct contact with a catalytic surface, enabling the observation of plasma-surface interactions. A key factor in their application is the generation of reactive species, such as atomic oxygen, within the cavities. These species can interact with both the surface (e.g. for activation or cleaning) and the gas being treated (e.g. for oxidation). Given the central role of oxygen atoms in plasma catalysis and their use as a model for more complex species, this work investigates the transport of these atoms out of the cavities. Two-photon absorption laser-induced fluorescence spectroscopy with picosecond laser excitation is performed in the volume above the cavities. The results are compared with a basic diffusion model. The reactor operates with a He/O2 mixture at a flow rate of 1 slm and atmospheric pressure. Densities of up to 1016 cm−3 are measured near the surface. Time-dependent measurements show that, at a distance of 350 µm from the surface, a density equilibrium is reached within less than 3 ms of reactor operation. Decay times due to ozone formation after the reactor is turned off are on a similar scale. Spatially resolved measurements show that the oxygen density decreases exponentially from the surface but remains detectable up to approximately 1 mm above the surface, indicating significant application potential. Variations in the O2 admixture show a density maximum at 0.4%, confirming previous helium state enhanced actinometry measurements within the cavities.