Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Sergio Martín-Martínez has a total of 101 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Harmonic Emission Variability in Identical PV Inverters Installed in Different Solar Farms

    by Alejandro Carretero-Hernández, José Alfonso Calero-Sevillano, Estefanía Artigao, Sergio Martín-Martínez

    The increasing integration of photovoltaic (PV) power plants into electrical grids has raised concerns regarding the harmonic emissions caused by power electronic devices. Understanding the impact of large-scale PV plants on power systems is essential for ensuring grid stability and power quality. This study analyses and compares the current harmonic emissions of two inverters with identical topologies, installed in two different PV plants: a 35 MW plant in Spain and a 12 MW plant in Greece. The results reveal significant differences in the harmonic emission spectra between the two inverters, highlighting the influence of external conditions on the harmonic behaviour of PV inverters. These findings underscore the necessity of considering site-specific factors when assessing the harmonic impact of large-scale PV installations.


  • Open Access

    Implementation of the RCM Methodology as a Technical Analysis for Maintenance and Innovation for Hydroelectric Power Plants

    by Francisco Javier Martínez Monseco, Emilio Gómez Lázaro, Sergio Martín Martínez

    Hydroelectric power plants are renewable electricity generation assets that require high availability and reliability in their operation and maintenance. To justify improvement actions (modernization and investments), it is necessary to analyze the operation of the plant, the maintenance plan being implemented, and, naturally, the incidents and breakdowns that affect this asset. This paper presents research on hydroelectric power plant maintenance based on the development of a database of incidents and failures of such plants, considering the methodology of failure modes, effects and criticality analysis (FMECA) as well as the reliability-centered maintenance (RCM) methodology of the initial maintenance plan of a standard hydroelectric power plant. Different maintenance standards and analysis standards (IATF criticality of failure modes, UNE 13306, ISO 14224, etc.) were considered. The results reveal different improvement and optimization actions based on the current technological development, which can be applied to hydroelectric generation (Innovation 4.0), as well as actions to optimize the initial maintenance plan based on Maintenance 4.0. The technical justification for such improvements in hydropower generation highlights a key area of development in the expansion of renewable energies worldwide. Hydropower generation assets have contributed renewable energy to the system for many years; however, they now require redesign in their operation and maintenance.


  • Open Access

    Voltage harmonic effect of a large-scale solar PV plant on high-voltage transmission network

    by A. Carretero-Hernández, J. Jiménez-Ruiz, S. Martín-Martínez, E. Artigao, E. Gómez-Lázaro


  • Open Access

    Short-Medium-Term Solar Irradiance Forecasting with a CEEMDAN-CNN-ATT-LSTM Hybrid Model Using Meteorological Data

    by Max Camacho, Jorge Maldonado-Correa, Joel Torres-Cabrera, Sergio Martín-Martínez, Emilio Gómez-Lázaro

    In recent years, the adverse effects of climate change have increased rapidly worldwide, driving countries to transition to clean energy sources such as solar and wind. However, these energies face challenges such as cloud cover, precipitation, wind speed, and temperature, which introduce variability and intermittency in power generation, making integration into the interconnected grid difficult. To achieve this, we present a novel hybrid deep learning model, CEEMDAN-CNN-ATT-LSTM, for short- and medium-term solar irradiance prediction. The model utilizes complete empirical ensemble modal decomposition with adaptive noise (CEEMDAN) to extract intrinsic seasonal patterns in solar irradiance. In addition, it employs a hybrid encoder-decoder framework that combines convolutional neural networks (CNN) to capture spatial relationships between variables, an attention mechanism (ATT) to identify long-term patterns, and a long short-term memory (LSTM) network to capture short-term dependencies in time series data. This model has been validated using meteorological data in a more than 2400 masl region characterized by complex climatic conditions south of Ecuador. It was able to predict irradiance at 1, 6, and 12 h horizons, with a mean absolute error (MAE) of 99.89 W/m2 in winter and 110.13 W/m2 in summer, outperforming the reference methods of this study. These results demonstrate that our model represents progress in contributing to the scientific community in the field of solar energy in environments with high climatic variability and its applicability in real scenarios.


  • Open Access

    A Novel Data-Driven Approach with a Long Short-Term Memory Autoencoder Model with a Multihead Self-Attention Deep Learning Model for Wind Turbine Converter Fault Detection

    by Joel Torres-Cabrera, Jorge Maldonado-Correa, Marcelo Valdiviezo-Condolo, Estefanía Artigao, Sergio Martín-Martínez, Emilio Gómez-Lázaro

    The imminent depletion of oil resources and increasing environmental pollution have driven the use of clean energy, particularly wind energy. However, wind turbines (WTs) face significant challenges, such as critical component failures, which can cause unexpected shutdowns and affect energy production. To address this challenge, we analyzed the Supervisory Control and Data Acquisition (SCADA) data to identify significant differences between the relationship of variables based on data reconstruction errors between actual and predicted values. This study proposes a hybrid short- and long-term memory autoencoder model with multihead self-attention (LSTM-MA-AE) for WT converter fault detection. The proposed model identifies anomalies in the data by comparing the reconstruction errors of the variables involved. However, more is needed. To address this model limitation, we developed a fault prediction system that employs an adaptive threshold with an Exponentially Weighted Moving Average (EWMA) and a fixed threshold. This system analyzes the anomalies of several variables and generates fault warnings in advance time. Thus, we propose an outlier detection method through data preprocessing and unsupervised learning, using SCADA data collected from a wind farm located in complex terrain, including real faults in the converter. The LSTM-MA-AE is shown to be able to predict the converter failure 3.3 months in advance, and with an F1 greater than 90% in the tests performed. The results provide evidence of the potential of the proposed model to improve converter fault diagnosis with SCADA data in complex environments, highlighting its ability to increase the reliability and efficiency of WTs.


  • Top Cited Papers
    Open Access

    Wind turbine fault detection based on the transformer model using SCADA data

    by Jorge Maldonado-Correa, Joel Torres-Cabrera, Sergio Martín-Martínez, Estefanía Artigao, Emilio Gómez-Lázaro


  • Open Access

    Classification of Highly Imbalanced Supervisory Control and Data Acquisition Data for Fault Detection of Wind Turbine Generators

    by Jorge Maldonado-Correa, Marcelo Valdiviezo-Condolo, Estefanía Artigao, Sergio Martín-Martínez, Emilio Gómez-Lázaro

    It is common knowledge that wind energy is a crucial, strategic component of the mix needed to create a green economy. In this regard, optimizing the operations and maintenance (O&M) of wind turbines (WTs) is key, as it will serve to reduce the levelized cost of electricity (LCOE) of wind energy. Since most modern WTs are equipped with a Supervisory Control and Data Acquisition (SCADA) system for remote monitoring and control, condition-based maintenance using SCADA data is considered a promising solution, although certain drawbacks still exist. Typically, large amounts of normal-operating SCADA data are generated against small amounts of fault-related data. In this study, we use high-frequency SCADA data from an operating WT with a significant imbalance between normal and fault classes. We implement several resampling techniques to address this challenge and generate synthetic generator fault data. In addition, several machine learning (ML) algorithms are proposed for processing the resampled data and WT generator fault classification. Experimental results show that ADASYN + Random Forest obtained the best performance, providing promising results toward wind farm O&M optimization.


  • Open Access

    Solar PV power plant revamping: Technical and economic analysis of different alternatives for a Spanish case

    by R. Villena-Ruiz, S. Martín-Martínez, A. Honrubia-Escribano, F. Javier Ramírez, E. Gómez-Lázaro


  • Comparison of harmonic emission in LV side of a large grid connected PV power plant

    by A. Carretero-Hernandez, E. Artigao, S. Martin-Martinez, C. Alvarez-Ortega, M. Ochoa-Gimenez, E. Gomez-Lazaro