Duxin Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Duxin Li has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Oliver Johannes Schmitz
Applied Analytical Chemistry, University of Duisburg-Essen, Essen, Germany
6 shared publications - Weibing Zhang
Shanghai Key Laboratory of Functional Materials Chemistry , East China University of Science and Technology , Shanghai , P. R. China
3 shared publications Lingyi Zhang
East China University of Science and Technology
2 shared publicationsAlexandra von Trotha
1 shared publicationAmela Bronja
University of Duisburg-Essen, Applied Analytical Chemistry, Universitaetsstr. 5-7, 45141 Essen, Germany
1 shared publication- Azeem Intisar
School of Chemistry, University of the Punjab, Lahore, Pakistan
1 shared publication
Latest Publications
- 1 September 2015
- Published by Elsevier in Analytica Chimica Acta
- Vol. 891, 43-61
Gas chromatography coupled to atmospheric pressure ionization mass spectrometry (GC-API-MS): Review
- 1 September 2015
- Published by Elsevier in Analytica Chimica Acta
- Vol. 891, 43-61
Gas chromatography coupled to atmospheric pressure ionization mass spectrometry (GC-API-MS): Review
- 14 October 2014
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 407 (1) , 153-167
Practical considerations in comprehensive two-dimensional liquid chromatography systems (LCxLC) with reversed-phases in both dimensions
Online comprehensive two-dimensional liquid chromatography (online LCxLC) presents high peak capacity compared with one-dimensional liquid chromatography, and reasonable operation time compared with an offline or stop-flow mode. Among various combinations, coupling of two reversed-phase (RPxRP) columns generates a high peak capacity product rate. Its wide applicability made RPxRP a promising technique in separation of complex samples. This review discusses the practical considerations in development and application of an RPxRP system, including systematic investigation of column stationary phase chemistry, column combinations, mobile phase system, interface, gradient types, and achieving fast analysis in LCxLC. In addition, many efforts are given to methods that increase the fraction coverage because this is the main obstacle caused by the correlated separation mechanism in RPxRP. Graphical Abstract
- 14 October 2014
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 407 (1) , 153-167
Practical considerations in comprehensive two-dimensional liquid chromatography systems (LCxLC) with reversed-phases in both dimensions
Online comprehensive two-dimensional liquid chromatography (online LCxLC) presents high peak capacity compared with one-dimensional liquid chromatography, and reasonable operation time compared with an offline or stop-flow mode. Among various combinations, coupling of two reversed-phase (RPxRP) columns generates a high peak capacity product rate. Its wide applicability made RPxRP a promising technique in separation of complex samples. This review discusses the practical considerations in development and application of an RPxRP system, including systematic investigation of column stationary phase chemistry, column combinations, mobile phase system, interface, gradient types, and achieving fast analysis in LCxLC. In addition, many efforts are given to methods that increase the fraction coverage because this is the main obstacle caused by the correlated separation mechanism in RPxRP. Graphical Abstract
- 1 September 2014
- Published by Elsevier in Journal of Chromatography A
- Vol. 1358, 128-135
The advantage of mixed-mode separation in the first dimension of comprehensive two-dimensional liquid-chromatography
- 1 September 2014
- Published by Elsevier in Journal of Chromatography A
- Vol. 1358, 128-135
The advantage of mixed-mode separation in the first dimension of comprehensive two-dimensional liquid-chromatography
- 30 August 2014
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 407 (1) , 231-240
Comprehensive two-dimensional liquid chromatography tandem diode array detector (DAD) and accurate mass QTOF-MS for the analysis of flavonoids and iridoid glycosides in Hedyotis diffusa
The analysis of chemical constituents in Chinese herbal medicines (CHMs) is a challenge because of numerous compounds with various polarities and functional groups. Liquid chromatography coupled with quadrupole time-of-flight (QTOF) mass spectrometry (LC/MS) is of particular interest in the analysis of herbal components. One of the main attributes of QTOF that makes it an attractive analytical technique is its accurate mass measurement for both precursor and product ions. For the separation of CHMs, comprehensive two-dimensional chromatography (LCxLC) provides much higher resolving power than traditional one-dimensional separation. Therefore, a LCxLC-QTOF-MS system was developed and applied to the analysis of flavonoids and iridoid glycosides in aqueous extracts of Hedyotis diffusa (Rubiaceae). Shift gradient was applied in the two-dimensional separation in the LCxLC system to increase the orthogonality and effective peak distribution area of the analysis. Tentative identification of compounds was done by accurate mass interpretation and validation by UV spectrum. A clear classification of flavonol glycosides (FGs), acylated FGs, and iridoid glycosides (IGs) was shown in different regions of the LCxLC contour plot. In total, five FGs, four acylated FGs, and three IGs were tentatively identified. In addition, several novel flavonoids were found, which demonstrates that LCxLC-QTOF-MS detection also has great potential in herbal medicine analysis.
- 30 August 2014
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 407 (1) , 231-240
Comprehensive two-dimensional liquid chromatography tandem diode array detector (DAD) and accurate mass QTOF-MS for the analysis of flavonoids and iridoid glycosides in Hedyotis diffusa
The analysis of chemical constituents in Chinese herbal medicines (CHMs) is a challenge because of numerous compounds with various polarities and functional groups. Liquid chromatography coupled with quadrupole time-of-flight (QTOF) mass spectrometry (LC/MS) is of particular interest in the analysis of herbal components. One of the main attributes of QTOF that makes it an attractive analytical technique is its accurate mass measurement for both precursor and product ions. For the separation of CHMs, comprehensive two-dimensional chromatography (LCxLC) provides much higher resolving power than traditional one-dimensional separation. Therefore, a LCxLC-QTOF-MS system was developed and applied to the analysis of flavonoids and iridoid glycosides in aqueous extracts of Hedyotis diffusa (Rubiaceae). Shift gradient was applied in the two-dimensional separation in the LCxLC system to increase the orthogonality and effective peak distribution area of the analysis. Tentative identification of compounds was done by accurate mass interpretation and validation by UV spectrum. A clear classification of flavonol glycosides (FGs), acylated FGs, and iridoid glycosides (IGs) was shown in different regions of the LCxLC contour plot. In total, five FGs, four acylated FGs, and three IGs were tentatively identified. In addition, several novel flavonoids were found, which demonstrates that LCxLC-QTOF-MS detection also has great potential in herbal medicine analysis.
- 6 November 2013
- Published by Wiley in Nachrichten aus der Chemie
- Vol. 61 (11) , 1135-1137
Komplexe Proben und zweidimensionale Trennmethoden
- 6 November 2013
- Published by Wiley in Nachrichten aus der Chemie
- Vol. 61 (11) , 1135-1137
Komplexe Proben und zweidimensionale Trennmethoden
- 13 June 2013
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 405 (20) , 6511-6517
Use of shift gradient in the second dimension to improve the separation space in comprehensive two-dimensional liquid chromatography
Comprehensive two-dimensional liquid chromatography (LC × LC) has received much attention because it offers much higher peak capacities than separation in a single dimension. The advantageous peak capacity makes it attractive for the separation of complex samples. Various gradient methods have been used in LC × LC systems. The use of continuous shift gradient is advantageous because it combines the peak compression effect of full gradient mode and the tailed gradient program in parallel gradient mode. Here, a comparison of LC × LC analysis of Chinese herbal medicine with full gradient mode and shift gradient mode in the second dimension was performed. A correlation between the first and second dimensions was found in full gradient mode, and this was significantly reduced with shift gradient mode. The orthogonality increased by 43.7 %. The effective peak distribution area increased significantly, which produced better separation.
- 13 June 2013
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 405 (20) , 6511-6517
Use of shift gradient in the second dimension to improve the separation space in comprehensive two-dimensional liquid chromatography
Comprehensive two-dimensional liquid chromatography (LC × LC) has received much attention because it offers much higher peak capacities than separation in a single dimension. The advantageous peak capacity makes it attractive for the separation of complex samples. Various gradient methods have been used in LC × LC systems. The use of continuous shift gradient is advantageous because it combines the peak compression effect of full gradient mode and the tailed gradient program in parallel gradient mode. Here, a comparison of LC × LC analysis of Chinese herbal medicine with full gradient mode and shift gradient mode in the second dimension was performed. A correlation between the first and second dimensions was found in full gradient mode, and this was significantly reduced with shift gradient mode. The orthogonality increased by 43.7 %. The effective peak distribution area increased significantly, which produced better separation.
- 18 March 2011
- Published by Springer Nature in Chromatographia
- Vol. 73 (9-10) , 871-877
Development of a Parallel-Tandem Column Interface in a Two-Dimensional Liquid Chromatography System
- 18 March 2011
- Published by Springer Nature in Chromatographia
- Vol. 73 (9-10) , 871-877
Development of a Parallel-Tandem Column Interface in a Two-Dimensional Liquid Chromatography System
- 14 April 2010
- Published by China Science Publishing & Media Ltd. in Chinese Journal of Chromatography
- Vol. 28 (2) , 163-167
Improvement of interface in comprehensive two-dimensional liquid chromatography and its application in the research of proteomics
A two-dimensional liquid chromatography (2D-LC) system was constructed with improved trap column interface. Weak anion exchange (WAX) LC was used as the first dimension separation mode and reversed-phase (RP) LC as the second dimension. Two 35 mm long columns (column 1 and column 2) were used as trap columns to retain the fraction from the first dimension, and forward-flushing was employed to pre-separate the components when the trap column was connected to the second dimension. The interface greatly increases the efficiency of the second dimension column without losing the separation speed. Rat serum sample was separated on this system to evaluate the performance of the constructed system. The viscous fingering (VF) phenomenon was generated attribute to the difference in the velocities of the mobile phases of the two dimensions. The separation efficiency was theoretically increased by 70% when the 35 mm trap columns were used in the forward-flush mode.
- 14 April 2010
- Published by China Science Publishing & Media Ltd. in Chinese Journal of Chromatography
- Vol. 28 (2) , 163-167
Improvement of interface in comprehensive two-dimensional liquid chromatography and its application in the research of proteomics
A two-dimensional liquid chromatography (2D-LC) system was constructed with improved trap column interface. Weak anion exchange (WAX) LC was used as the first dimension separation mode and reversed-phase (RP) LC as the second dimension. Two 35 mm long columns (column 1 and column 2) were used as trap columns to retain the fraction from the first dimension, and forward-flushing was employed to pre-separate the components when the trap column was connected to the second dimension. The interface greatly increases the efficiency of the second dimension column without losing the separation speed. Rat serum sample was separated on this system to evaluate the performance of the constructed system. The viscous fingering (VF) phenomenon was generated attribute to the difference in the velocities of the mobile phases of the two dimensions. The separation efficiency was theoretically increased by 70% when the 35 mm trap columns were used in the forward-flush mode.
- 1 January 2008
- Vol. 26 (1) , 105-9
[Research progress of ultrahigh-pressure liquid chromatograph and the related issues caused by ultrahigh-pressure].
Characterized by high performance and rapid analysis, ultrahigh-pressure liquid chromatography using sub-2 microm packings becomes one of the new orientations of liquid chromatography. On the basis of the research of influence of the pressure on the properties of chromatography, the development of ultrahigh-pressure liquid chromatograph and its related issues are reviewed, and 36 papers are cited.
- 1 January 2008
- Vol. 26 (1) , 105-9
[Research progress of ultrahigh-pressure liquid chromatograph and the related issues caused by ultrahigh-pressure].
Characterized by high performance and rapid analysis, ultrahigh-pressure liquid chromatography using sub-2 microm packings becomes one of the new orientations of liquid chromatography. On the basis of the research of influence of the pressure on the properties of chromatography, the development of ultrahigh-pressure liquid chromatograph and its related issues are reviewed, and 36 papers are cited.