Carlos Hernandez-Matas
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Carlos Hernandez-Matas has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Xenophon Zabulis
Foundation for Research and Technology Hellas, Heraklion, Greece, Greece
7 shared publications - Antonis Argyros
University of Crete
4 shared publications Antonia M. Joussen
Department of Ophthalmology, Charité University Medicine Berlin, Berlin, Germany
1 shared publicationAntonis A. Argyros
Institute of Computer Science, Foundation for Research and Technology-Hellas, Heraklion, 70013 Greece; Computer Science Department, University of Crete, Heraklion, 70013 Greece
1 shared publication- Areti Triantafyllou
First Propedeutic Department of Internal Medicine, Hypertension Outpatient Clinic and ESH Excellence Center, AHEPA University Hospital, Aristotle University of Thessaloniki, 54636 Thessaloniki, Greece
1 shared publication Claudia Brockmann
Department of Ophthalmology, Charité University Medicine Berlin, Berlin, Germany
1 shared publication
Latest Publications
- 1 February 2021
- Published by Elsevier in Computer Methods and Programs in Biomedicine
- Vol. 199, 105900
Retinal image registration as a tool for supporting clinical applications
- 1 February 2021
- Published by Elsevier in Computer Methods and Programs in Biomedicine
- Vol. 199, 105900
Retinal image registration as a tool for supporting clinical applications
- 2 April 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 24 (12) , 3362-3373
REMPE: Registration of Retinal Images Through Eye Modelling and Pose Estimation
$Objective:$ In-vivo assessment of small vessels can promote accurate diagnosis and monitoring of diseases related to vasculopathy, such as hypertension and diabetes. The eye provides a unique, open, and accessible window for directly imaging small vessels in the retina with non-invasive techniques, such as fundoscopy. In this context, accurate registration of retinal images is of paramount importance in the comparison of vessel measurements from original and follow-up examinations, which is required for monitoring the disease and its treatment. At the same time, retinal registration exhibits a range of challenges due to the curved shape of the retina and the modification of imaged tissue across examinations. Thereby, the objective is to improve the state-of-the-art in the accuracy of retinal image registration.
- 2 April 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 24 (12) , 3362-3373
REMPE: Registration of Retinal Images Through Eye Modelling and Pose Estimation
$Objective:$ In-vivo assessment of small vessels can promote accurate diagnosis and monitoring of diseases related to vasculopathy, such as hypertension and diabetes. The eye provides a unique, open, and accessible window for directly imaging small vessels in the retina with non-invasive techniques, such as fundoscopy. In this context, accurate registration of retinal images is of paramount importance in the comparison of vessel measurements from original and follow-up examinations, which is required for monitoring the disease and its treatment. At the same time, retinal registration exhibits a range of challenges due to the curved shape of the retina and the modification of imaged tissue across examinations. Thereby, the objective is to improve the state-of-the-art in the accuracy of retinal image registration.
- 1 January 2017
- Published by Elsevier in Computerized Medical Imaging and Graphics
- Vol. 55, 95-105
Retinal image registration under the assumption of a spherical eye
- 1 January 2017
- Published by Elsevier in Computerized Medical Imaging and Graphics
- Vol. 55, 95-105
Retinal image registration under the assumption of a spherical eye
- 18 October 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2016, 3247-3251
Retinal image registration through simultaneous camera pose and eye shape estimation
In this paper, a retinal image registration method is proposed. The approach utilizes keypoint correspondences and assumes that the human eye has a spherical or ellipsoidal shape. The image registration problem amounts to solving a camera 3D pose estimation problem and, simultaneously, an eye 3D shape estimation problem. The camera pose estimation problem is solved by estimating the relative pose between the views from which the images were acquired. The eye shape estimation problem parameterizes the shape and orientation of an ellipsoidal model for the eye. Experimental evaluation shows 17.91% reduction of registration error and 47.52% reduction of the error standard deviation over state of the art methods.
- 18 October 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2016, 3247-3251
Retinal image registration through simultaneous camera pose and eye shape estimation
In this paper, a retinal image registration method is proposed. The approach utilizes keypoint correspondences and assumes that the human eye has a spherical or ellipsoidal shape. The image registration problem amounts to solving a camera 3D pose estimation problem and, simultaneously, an eye 3D shape estimation problem. The camera pose estimation problem is solved by estimating the relative pose between the views from which the images were acquired. The eye shape estimation problem parameterizes the shape and orientation of an ellipsoidal model for the eye. Experimental evaluation shows 17.91% reduction of registration error and 47.52% reduction of the error standard deviation over state of the art methods.
- 1 October 2015
- Published by Elsevier in Experimental Eye Research
- Vol. 139, 13-21
In vivo analysis of the time and spatial activation pattern of microglia in the retina following laser-induced choroidal neovascularization
- 1 October 2015
- Published by Elsevier in Experimental Eye Research
- Vol. 139, 13-21
In vivo analysis of the time and spatial activation pattern of microglia in the retina following laser-induced choroidal neovascularization
- 1 August 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2015 (1094687X) , 5650-5654
Retinal image registration based on keypoint correspondences, spherical eye modeling and camera pose estimation
In this work, an image registration method for two retinal images is proposed. The proposed method utilizes keypoint correspondences and assumes a spherical model of the eye. Image registration is treated as a pose estimation problem, which requires estimation of the rigid transformation that relates the two images. Using this estimate, one image can be warped so that it is registered to the coordinate frame of the other. Experimental evaluation shows improved accuracy over state-of-the-art approaches as well as robustness to noise and spurious keypoint correspondences. Experiments also indicate the method's applicability to diagnostic image enhancement and comparative analysis of images from different examinations.
- 1 August 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2015 (1094687X) , 5650-5654
Retinal image registration based on keypoint correspondences, spherical eye modeling and camera pose estimation
In this work, an image registration method for two retinal images is proposed. The proposed method utilizes keypoint correspondences and assumes a spherical model of the eye. Image registration is treated as a pose estimation problem, which requires estimation of the rigid transformation that relates the two images. Using this estimate, one image can be warped so that it is registered to the coordinate frame of the other. Experimental evaluation shows improved accuracy over state-of-the-art approaches as well as robustness to noise and spurious keypoint correspondences. Experiments also indicate the method's applicability to diagnostic image enhancement and comparative analysis of images from different examinations.
- 1 August 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE) in 2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)
- Vol. 2014 (1094687X) , 6332-6338
Super resolution for fundoscopy based on 3D image registration
An approach to the generation of super-resolution (SR) images from fundoscopy images is proposed that is based on the 3D registration of the original fundoscopy images. The proposed approach utilizes a simple 3D registration method to enable the application of conventional SR techniques which, otherwise, employ 2D image registration. Qualitative and quantitative comparative evaluation shows that the obtained results improve image definition and alleviate noise.
- 1 August 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE) in 2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)
- Vol. 2014 (1094687X) , 6332-6338
Super resolution for fundoscopy based on 3D image registration
An approach to the generation of super-resolution (SR) images from fundoscopy images is proposed that is based on the 3D registration of the original fundoscopy images. The proposed approach utilizes a simple 3D registration method to enable the application of conventional SR techniques which, otherwise, employ 2D image registration. Qualitative and quantitative comparative evaluation shows that the obtained results improve image definition and alleviate noise.