Ali Hassan Elmokadem
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Ali Hassan Elmokadem has a total of 148 co-authors. Here are the top co-authors by number of shared publications:
Ahmed El-Morsy
Department of Radiology, Mansoura University, Mansoura, Egypt
6 shared publicationsTalal Amer
Department of Radiology, Mansoura University, Mansoura, Egypt
4 shared publications- Dalia Bayoumi
Department of Radiology, Mansoura University, Mansoura, Egypt
3 shared publications Rihame M. Abdel-Wahab
Department of Radiology, Mansoura University, Elgomhoria St., Mansoura, 35516, Egypt
3 shared publications- Sameer A. Ansari
Department of Radiology, Northwestern University, Feinberg School of Medicine
3 shared publications - Sherif A. Abo-Hedibah
Cairo University, Giza, Egypt
3 shared publications
Latest Publications
- Open Access
- 9 July 2024
- Published by Springer Nature in Egyptian Journal of Radiology and Nuclear Medicine
- Vol. 55 (1) , 1-11
Inter-observer and inter-modality concordance of non-contrast MR angiography and CT angiography for preoperative assessment of potential renal donors
Background: Magnetic resonance angiography (MRA) is rapidly being employed as an effective substitute for CTA, particularly in situations of poor kidney function. We aimed to examine the inter-observer and inter-modality reliability of non-contrast MR angiography (NC-MRA) and CTA as a non-invasive tool for assessing the anatomical findings of potential living kidney donors. Results: All potential donors were referred from specialized kidney transplantation center and underwent NC-MRA of the renal arteries using a respiratory-triggered magnetization prepared 3D balanced steady-state free precession (b-SSFP) with inversion recovery pulses and fat saturation (Inhance 3D Inflow Inversion Recovery (IFIR)). Two experienced radiologists reviewed NC-MRA images and were asked to evaluate both renal arteries anatomy and their branching pattern, presence of accessory or aberrant renal arteries, and identify any anatomical variant. Lin’s correlation test was performed to test MRA readings by each of the two observers against CTA findings which considered as the gold standard for assessment of renal arteries. Additionally, observers were asked to assess the image quality. The study included 60 potential kidney donors (43 males and 17 females) with mean age ± SD of 31.3 ± 5.6 years. Excellent to very good inter-observer agreement was found between both observers in the assessment of renal arteries by NC-MRA. There was perfect concordance between MRA and CTA findings in detecting early arterial division, caliber, and length of left extra-parenchymal segmental branches. Moderate concordance was found in the assessment of the supplied segments of extra-parenchymal segmental renal arterial branches and substantial concordance between both MRA observers’ findings in the remaining variables of the study. There was excellent agreement between both observers in the assessment of image quality parameters. Conclusions: NC-MRA for the renal arteries is an effective alternative for CTA without the risks of radiation or contrast media.
- 9 July 2024
- Published by Springer Nature in Egyptian Journal of Radiology and Nuclear Medicine
- Vol. 55 (1) , 1-11
Open AccessInter-observer and inter-modality concordance of non-contrast MR angiography and CT angiography for preoperative assessment of potential renal donors
Background: Magnetic resonance angiography (MRA) is rapidly being employed as an effective substitute for CTA, particularly in situations of poor kidney function. We aimed to examine the inter-observer and inter-modality reliability of non-contrast MR angiography (NC-MRA) and CTA as a non-invasive tool for assessing the anatomical findings of potential living kidney donors. Results: All potential donors were referred from specialized kidney transplantation center and underwent NC-MRA of the renal arteries using a respiratory-triggered magnetization prepared 3D balanced steady-state free precession (b-SSFP) with inversion recovery pulses and fat saturation (Inhance 3D Inflow Inversion Recovery (IFIR)). Two experienced radiologists reviewed NC-MRA images and were asked to evaluate both renal arteries anatomy and their branching pattern, presence of accessory or aberrant renal arteries, and identify any anatomical variant. Lin’s correlation test was performed to test MRA readings by each of the two observers against CTA findings which considered as the gold standard for assessment of renal arteries. Additionally, observers were asked to assess the image quality. The study included 60 potential kidney donors (43 males and 17 females) with mean age ± SD of 31.3 ± 5.6 years. Excellent to very good inter-observer agreement was found between both observers in the assessment of renal arteries by NC-MRA. There was perfect concordance between MRA and CTA findings in detecting early arterial division, caliber, and length of left extra-parenchymal segmental branches. Moderate concordance was found in the assessment of the supplied segments of extra-parenchymal segmental renal arterial branches and substantial concordance between both MRA observers’ findings in the remaining variables of the study. There was excellent agreement between both observers in the assessment of image quality parameters. Conclusions: NC-MRA for the renal arteries is an effective alternative for CTA without the risks of radiation or contrast media.
- 12 June 2024
- Published by SAGE Publications in The Neuroradiology Journal
- Vol. 37 (6) , 751-757
Utility of diffusion tensor imaging in differentiating benign from malignant thyroid nodules
Purpose: To assess diffusion tensor imaging (DTI) in differentiating benign from malignant thyroid nodules. Methods: A retrospective analysis was done on 55 patients with thyroid nodules who had undergone DTI. The fraction anisotropy (FA) and mean diffusivity (MD) of the thyroid nodules were measured using region of interest (ROI) by two observers. The final diagnosis was malignant and benign, as proved by pathological examination. Results: The mean MD of benign thyroid nodules (1.84 ± 0.42 and 1.90 ± 0.37 × 10-3mm2/s) was significantly higher ( p < .001) than malignant nodules (0.95 ± 0.46 and 0.97 ± 0.41 × 10-3mm2/s) as scored by both observers. The cut-off values of 1.45 and 1.50 × 10-3mm2/s were used to differentiate malignant from benign thyroid nodules with the areas under the curve (AUC) of 0.926 and 0.937, respectively. The mean FA of benign thyroid nodules (0.23 ± 0.07 and 0.24 ± 0.08) was significantly lower ( p < .001) than malignant nodules (0.48 ± 0.21 and 0.49 ± 0.18). The FA cut-off value of ≤0.32 and 0.33 was used for differentiating malignant from benign thyroid nodules with an AUC of 0.877 and 0.881, respectively. A combination of MD and FA values was used to differentiate benign from malignant thyroid nodules with an AUC of 0.932 and an accuracy of 87%. There was an excellent agreement between both observers for FA and MD (K = 0.939, 0.929). Conclusion: The DTI is a non-invasive, non-contrast imaging tool that can differentiate benign from malignant thyroid nodules.
- 12 June 2024
- Published by SAGE Publications in The Neuroradiology Journal
- Vol. 37 (6) , 751-757
Utility of diffusion tensor imaging in differentiating benign from malignant thyroid nodules
Purpose: To assess diffusion tensor imaging (DTI) in differentiating benign from malignant thyroid nodules. Methods: A retrospective analysis was done on 55 patients with thyroid nodules who had undergone DTI. The fraction anisotropy (FA) and mean diffusivity (MD) of the thyroid nodules were measured using region of interest (ROI) by two observers. The final diagnosis was malignant and benign, as proved by pathological examination. Results: The mean MD of benign thyroid nodules (1.84 ± 0.42 and 1.90 ± 0.37 × 10-3mm2/s) was significantly higher ( p < .001) than malignant nodules (0.95 ± 0.46 and 0.97 ± 0.41 × 10-3mm2/s) as scored by both observers. The cut-off values of 1.45 and 1.50 × 10-3mm2/s were used to differentiate malignant from benign thyroid nodules with the areas under the curve (AUC) of 0.926 and 0.937, respectively. The mean FA of benign thyroid nodules (0.23 ± 0.07 and 0.24 ± 0.08) was significantly lower ( p < .001) than malignant nodules (0.48 ± 0.21 and 0.49 ± 0.18). The FA cut-off value of ≤0.32 and 0.33 was used for differentiating malignant from benign thyroid nodules with an AUC of 0.877 and 0.881, respectively. A combination of MD and FA values was used to differentiate benign from malignant thyroid nodules with an AUC of 0.932 and an accuracy of 87%. There was an excellent agreement between both observers for FA and MD (K = 0.939, 0.929). Conclusion: The DTI is a non-invasive, non-contrast imaging tool that can differentiate benign from malignant thyroid nodules.
- 12 April 2024
- Published by Elsevier in Clinical Radiology
- Vol. 79 (7) , e892-e899
Texture analysis using non-contrast MRI to predict estrogen receptor status in breast cancer lesions: Is it feasible?
- 12 April 2024
- Published by Elsevier in Clinical Radiology
- Vol. 79 (7) , e892-e899
Texture analysis using non-contrast MRI to predict estrogen receptor status in breast cancer lesions: Is it feasible?
- Open Access
- 10 April 2024
- Published by Springer Nature in Egyptian Journal of Radiology and Nuclear Medicine
- Vol. 55 (1) , 1-8
The diagnostic efficacy of diffusion tensor imaging in children with chronic kidney disease: correlation with histopathology and serum biomarkers
Background: Children with chronic kidney disease (CKD) usually present with disease impact on growth besides cardiovascular problems that not only impact the patient's health during childhood but also affect their adult life. We aimed to identify the diagnostic role of diffusion tensor imaging (DTI) in CKD in pediatric using its metrics: apparent diffusion coefficient (ADC) and fraction anisotropy (FA). Results: This prospective study was performed on thirty-five CKD patients (16 girls, 19 boys; mean age 12.3 ± 2.6 years) and 19 sex- and age-matched controls. Both groups underwent renal DTI and renal function tests. Based on renal biopsy, patients with CKD were further categorized into sclerotic CKD (n = 25) and non-sclerotic CKD (n = 10). Mean FA renal medulla/cortex in CKD (0.18 ± 0.18 and 0.20 ± 0.17) was lower significantly (p = 0.001) than volunteers' (0.31 ± 0.19, 0.27 ± 0.18). The cutoff FA of renal medulla/cortex used for CKD diagnosis was 0.22 and 0.23 with AUC of 0.828, 0.838 and accuracy of 80.8%, 82.8%. Mean of renal medulla/cortex ADC in CKD (2.13 ± 0.23 and 1.93 ± 0.22 × 10−3 mm2/s) was higher significantly (p = 0.001) than that of volunteers' (1.67 ± 0.15 and 1.64 ± 0.133 × 10−3 mm2/s. ADC cutoff value of renal medulla/cortex used for CKD diagnosis was 1.86 and 1.74 × 10−3 mm2/s with AUC of 0.827, 0.82, 0.827, and 0.911, and accuracy of 80.6%, 79.6%, 82.8%, and 84.2%. Renal medulla/cortex FA in sclerotic CKD was significantly different (p = 0.001) from non-sclerotic CKD (0.25 ± 0.07 and 0.26 ± 0.08). Cortical and medullary FA in CKD patients correlated with e-GFR (r = 0.363, r = 0.317) and serum creatinine (r = − 0.467, r = − 0.383). Conclusions: Renal cortical/medullary FA can assist in diagnosing pediatric CKD, predict sclerotic CKD, and correlate with some serum biomarkers.
- 10 April 2024
- Published by Springer Nature in Egyptian Journal of Radiology and Nuclear Medicine
- Vol. 55 (1) , 1-8
Open AccessThe diagnostic efficacy of diffusion tensor imaging in children with chronic kidney disease: correlation with histopathology and serum biomarkers
Background: Children with chronic kidney disease (CKD) usually present with disease impact on growth besides cardiovascular problems that not only impact the patient's health during childhood but also affect their adult life. We aimed to identify the diagnostic role of diffusion tensor imaging (DTI) in CKD in pediatric using its metrics: apparent diffusion coefficient (ADC) and fraction anisotropy (FA). Results: This prospective study was performed on thirty-five CKD patients (16 girls, 19 boys; mean age 12.3 ± 2.6 years) and 19 sex- and age-matched controls. Both groups underwent renal DTI and renal function tests. Based on renal biopsy, patients with CKD were further categorized into sclerotic CKD (n = 25) and non-sclerotic CKD (n = 10). Mean FA renal medulla/cortex in CKD (0.18 ± 0.18 and 0.20 ± 0.17) was lower significantly (p = 0.001) than volunteers' (0.31 ± 0.19, 0.27 ± 0.18). The cutoff FA of renal medulla/cortex used for CKD diagnosis was 0.22 and 0.23 with AUC of 0.828, 0.838 and accuracy of 80.8%, 82.8%. Mean of renal medulla/cortex ADC in CKD (2.13 ± 0.23 and 1.93 ± 0.22 × 10−3 mm2/s) was higher significantly (p = 0.001) than that of volunteers' (1.67 ± 0.15 and 1.64 ± 0.133 × 10−3 mm2/s. ADC cutoff value of renal medulla/cortex used for CKD diagnosis was 1.86 and 1.74 × 10−3 mm2/s with AUC of 0.827, 0.82, 0.827, and 0.911, and accuracy of 80.6%, 79.6%, 82.8%, and 84.2%. Renal medulla/cortex FA in sclerotic CKD was significantly different (p = 0.001) from non-sclerotic CKD (0.25 ± 0.07 and 0.26 ± 0.08). Cortical and medullary FA in CKD patients correlated with e-GFR (r = 0.363, r = 0.317) and serum creatinine (r = − 0.467, r = − 0.383). Conclusions: Renal cortical/medullary FA can assist in diagnosing pediatric CKD, predict sclerotic CKD, and correlate with some serum biomarkers.
- 10 February 2023
- Published by Springer Nature in La radiologia medica
- Vol. 128 (3) , 289-298
Clinical utility of abbreviated breast MRI based on diffusion tensor imaging in patients underwent breast conservative therapy
Purpose To evaluate the added value of the diffusion tensor imaging (DTI) parameters to abbreviated breast MRI protocol in differentiating recurrent breast cancer from post-operative changes in cases of breast conservative surgery (BCS). Methods This prospective study was approved by our institutional review board. Written informed consent was obtained in all patients. 47 female patients (mean age, 49 years; range, 32–66 years) that previously underwent breast conservative surgery with a palpable mass were included in this study (62 breast lesions). Two abbreviated MRI protocols were compared using 1.5 Tesla MRI, AB-MRI 1 (axial T1, T2, pre-contrast T1, 1st post-contrast and subtracted images) and AB-MRI 2 (same sequences plus adding DTI). In both protocols, the wash-in rate was calculated. Histopathology was used as the standard of reference. Appropriate statistical tests were used to assess sensitivity, specificity, and diagnostic accuracy for each protocol. Results The mean total acquisition time was of 6 min for AB-MRI 1 and 10 min for AB-MRI 2 protocols while the mean interpretation time was of 57.5 and 75 s, respectively. Among analyzed DTI parameters, MD (mean diffusivity) showed the highest sensitivity (96.43%) and specificity (91.18%) (P value = < 0.001). FA (fractional anisotropy), AD (axial diffusivity) and RD (radial diffusivity) showed sensitivity = (78.57%, 82.14% and 85.71%), specificity = (88.24, 85.29% and 79.41%), respectively, P value (< 0.001). Conclusion DTI may be included in abbreviated MRI protocols without a significant increase in acquisition time and with the advantage of increasing specificity and clinical utility in the characterization of post-conservative breast lesions.
- 10 February 2023
- Published by Springer Nature in La radiologia medica
- Vol. 128 (3) , 289-298
Clinical utility of abbreviated breast MRI based on diffusion tensor imaging in patients underwent breast conservative therapy
Purpose To evaluate the added value of the diffusion tensor imaging (DTI) parameters to abbreviated breast MRI protocol in differentiating recurrent breast cancer from post-operative changes in cases of breast conservative surgery (BCS). Methods This prospective study was approved by our institutional review board. Written informed consent was obtained in all patients. 47 female patients (mean age, 49 years; range, 32–66 years) that previously underwent breast conservative surgery with a palpable mass were included in this study (62 breast lesions). Two abbreviated MRI protocols were compared using 1.5 Tesla MRI, AB-MRI 1 (axial T1, T2, pre-contrast T1, 1st post-contrast and subtracted images) and AB-MRI 2 (same sequences plus adding DTI). In both protocols, the wash-in rate was calculated. Histopathology was used as the standard of reference. Appropriate statistical tests were used to assess sensitivity, specificity, and diagnostic accuracy for each protocol. Results The mean total acquisition time was of 6 min for AB-MRI 1 and 10 min for AB-MRI 2 protocols while the mean interpretation time was of 57.5 and 75 s, respectively. Among analyzed DTI parameters, MD (mean diffusivity) showed the highest sensitivity (96.43%) and specificity (91.18%) (P value = < 0.001). FA (fractional anisotropy), AD (axial diffusivity) and RD (radial diffusivity) showed sensitivity = (78.57%, 82.14% and 85.71%), specificity = (88.24, 85.29% and 79.41%), respectively, P value (< 0.001). Conclusion DTI may be included in abbreviated MRI protocols without a significant increase in acquisition time and with the advantage of increasing specificity and clinical utility in the characterization of post-conservative breast lesions.
- 30 November 2022
- Published by SAGE Publications in Acta Radiologica
- Vol. 64 (5) , 2024-2032
Diagnostic accuracy of lower-dose cardiac CT in evaluating young infants with non-coronary complex congenital heart disease on a 64-slice multidetector CT scanner
Background: Redoable precise and non-invasive diagnostic imaging modality with the least radiation dose is essential for infants with congenital heart disease (CHD) . Purpose: To investigate the accuracy and estimate the radiation dose of our cardiac computed tomography (CCT) protocol. Material and Methods: A total of 82 infants with CHD underwent non-ECG-gated CCT without contrast timing scanning techniques and were retrospectively studied. The image quality and radiation dose were estimated. The radiation dose was compared statistically to virtual retrospective ECG-gated and prospective ECG-triggering scanning modes. The diagnostic accuracy was assessed assuming the surgical results as the diagnostic gold standard. Results: Most exams showed a high quality with low radiation doses compared to previous studies. The mean effective dose (ED) was 0.39 ± 1.2, significantly lower than that of the virtual retrospective ECG-gated and prospective ECG-triggering scanning and lower than in previous studies. Our CCT protocol has achieved a diagnostic accuracy of 99.52% with a sensitivity of 94.83% and specificity of 99.91%. Conclusion: Non-ECG-gated CCT without contrast timing techniques can detect the non-coronary cardiovascular defects of CHD in infants with an ultralow radiation dose and a high diagnostic accuracy.
- 30 November 2022
- Published by SAGE Publications in Acta Radiologica
- Vol. 64 (5) , 2024-2032
Diagnostic accuracy of lower-dose cardiac CT in evaluating young infants with non-coronary complex congenital heart disease on a 64-slice multidetector CT scanner
Background: Redoable precise and non-invasive diagnostic imaging modality with the least radiation dose is essential for infants with congenital heart disease (CHD) . Purpose: To investigate the accuracy and estimate the radiation dose of our cardiac computed tomography (CCT) protocol. Material and Methods: A total of 82 infants with CHD underwent non-ECG-gated CCT without contrast timing scanning techniques and were retrospectively studied. The image quality and radiation dose were estimated. The radiation dose was compared statistically to virtual retrospective ECG-gated and prospective ECG-triggering scanning modes. The diagnostic accuracy was assessed assuming the surgical results as the diagnostic gold standard. Results: Most exams showed a high quality with low radiation doses compared to previous studies. The mean effective dose (ED) was 0.39 ± 1.2, significantly lower than that of the virtual retrospective ECG-gated and prospective ECG-triggering scanning and lower than in previous studies. Our CCT protocol has achieved a diagnostic accuracy of 99.52% with a sensitivity of 94.83% and specificity of 99.91%. Conclusion: Non-ECG-gated CCT without contrast timing techniques can detect the non-coronary cardiovascular defects of CHD in infants with an ultralow radiation dose and a high diagnostic accuracy.
- 18 August 2022
- Published by Springer Nature in European Radiology
- Vol. 33 (2) , 1400-1411
Utility of diffusion tensor imaging in differentiating benign from malignant hepatic focal lesions
Objectives To assess the diagnostic accuracy of diffusion tensor imaging (DTI) in the characterization of hepatic focal lesions (HFLs) and compare it to diffusion-weighted imaging (DWI). Methods Prospective analysis was done for 49 patients (23 male and 26 female) with 74 HFLs who underwent dynamic MRI, DWI, and DTI. Apparent diffusion coefficient (ADC) values from DWI, fractional anisotropy (FA) values, and mean diffusivity (MD) values from DTI were measured by two independent radiologists. HFLs were classified into benign and malignant HFLs; the latter were subdivided into HCC and non-HCC lesions. Binary logistic regression was performed to analyze the associations between the DTI parameters and the distinction of malignant lesions. Results The ADC, MD, and FA at cutoff values of ≤ 1.17 × 10−3 mm2/s, ≤ 1.71 × 10−3 mm2/s, and > 0.29, respectively, are excellent discriminators for differentiating malignant and benign HFLs. The mean ADC and MD values of hemangiomas were significantly higher than HCC and non-HCC malignant lesions. In contrast, the mean FA values of hemangiomas were significantly lower than those of non-HCC malignant lesions and HCCs. The ADC and MD were very good discriminators at cutoff values of > 1.03 × 10−3 mm2/s and > 1.12 × 10−3 mm2/s, respectively. The FA at a cutoff value > 0.38 is an excellent discriminator for HCC versus non-HCC malignant lesions. Only FA value > 0.38 was a statistically significant independent predictor of HCC versus non-HCC lesions among the three parameters. There was an excellent inter-observer agreement with ICC > 0.9. Conclusion MD and FA of DTI are non-invasive, very good, and excellent discriminators superior to ADC measured by DWI for the differentiation of HFLs. Key Points • The ADC, MD, and FA at cutoff values of ≤ 1.17 × 10 −3 mm 2 /s, ≤ 1.71 × 10 −3 mm 2 /s, and > 0.29, respectively, are excellent discriminators for differentiating malignant and benign HFLs. • The mean ADC and MD values of hemangiomas were significantly higher than those of HCC and non-HCC malignant lesions. In contrast, the mean FA values of hemangiomas were significantly lower than those of non-HCC malignant lesions and HCCs, respectively. • Multivariate regression analysis revealed that only FA value > 0.38 was a statistically significant independent predictor of HCC vs. non-HCC lesions. A lesion with FA > 0.38 has 34 times higher odds of being HCC rather than non-HCC lesions
- 18 August 2022
- Published by Springer Nature in European Radiology
- Vol. 33 (2) , 1400-1411
Utility of diffusion tensor imaging in differentiating benign from malignant hepatic focal lesions
Objectives To assess the diagnostic accuracy of diffusion tensor imaging (DTI) in the characterization of hepatic focal lesions (HFLs) and compare it to diffusion-weighted imaging (DWI). Methods Prospective analysis was done for 49 patients (23 male and 26 female) with 74 HFLs who underwent dynamic MRI, DWI, and DTI. Apparent diffusion coefficient (ADC) values from DWI, fractional anisotropy (FA) values, and mean diffusivity (MD) values from DTI were measured by two independent radiologists. HFLs were classified into benign and malignant HFLs; the latter were subdivided into HCC and non-HCC lesions. Binary logistic regression was performed to analyze the associations between the DTI parameters and the distinction of malignant lesions. Results The ADC, MD, and FA at cutoff values of ≤ 1.17 × 10−3 mm2/s, ≤ 1.71 × 10−3 mm2/s, and > 0.29, respectively, are excellent discriminators for differentiating malignant and benign HFLs. The mean ADC and MD values of hemangiomas were significantly higher than HCC and non-HCC malignant lesions. In contrast, the mean FA values of hemangiomas were significantly lower than those of non-HCC malignant lesions and HCCs. The ADC and MD were very good discriminators at cutoff values of > 1.03 × 10−3 mm2/s and > 1.12 × 10−3 mm2/s, respectively. The FA at a cutoff value > 0.38 is an excellent discriminator for HCC versus non-HCC malignant lesions. Only FA value > 0.38 was a statistically significant independent predictor of HCC versus non-HCC lesions among the three parameters. There was an excellent inter-observer agreement with ICC > 0.9. Conclusion MD and FA of DTI are non-invasive, very good, and excellent discriminators superior to ADC measured by DWI for the differentiation of HFLs. Key Points • The ADC, MD, and FA at cutoff values of ≤ 1.17 × 10 −3 mm 2 /s, ≤ 1.71 × 10 −3 mm 2 /s, and > 0.29, respectively, are excellent discriminators for differentiating malignant and benign HFLs. • The mean ADC and MD values of hemangiomas were significantly higher than those of HCC and non-HCC malignant lesions. In contrast, the mean FA values of hemangiomas were significantly lower than those of non-HCC malignant lesions and HCCs, respectively. • Multivariate regression analysis revealed that only FA value > 0.38 was a statistically significant independent predictor of HCC vs. non-HCC lesions. A lesion with FA > 0.38 has 34 times higher odds of being HCC rather than non-HCC lesions
- 8 August 2022
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 43 (8) , 1180-1183
DTI of the Olfactory Bulb in COVID-19-Related Anosmia: A Pilot Study
SUMMARY: This study aimed to assess the utility of DTI in the detection of olfactory bulb dysfunction in COVID-19-related anosmia. It was performed in 62 patients with COVID-19-related anosmia and 23 controls. The mean diffusivity and fractional anisotropy were calculated by 2 readers. The difference between the fractional anisotropy and mean diffusivity values of anosmic and control olfactory bulbs was statistically significant (P = .001). The threshold of fractional anisotropy and mean diffusivity to differentiate a diseased from normal olfactory bulb were 0.22 and 1.5, with sensitivities of 84.4% and 96.8%, respectively, and a specificity of 100%.
- 8 August 2022
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 43 (8) , 1180-1183
DTI of the Olfactory Bulb in COVID-19-Related Anosmia: A Pilot Study
SUMMARY: This study aimed to assess the utility of DTI in the detection of olfactory bulb dysfunction in COVID-19-related anosmia. It was performed in 62 patients with COVID-19-related anosmia and 23 controls. The mean diffusivity and fractional anisotropy were calculated by 2 readers. The difference between the fractional anisotropy and mean diffusivity values of anosmic and control olfactory bulbs was statistically significant (P = .001). The threshold of fractional anisotropy and mean diffusivity to differentiate a diseased from normal olfactory bulb were 0.22 and 1.5, with sensitivities of 84.4% and 96.8%, respectively, and a specificity of 100%.
- Open Access
- 28 April 2022
- Published by Baishideng Publishing Group Inc. in World Journal of Radiology
- Vol. 14 (4) , 91-103
Outcome of percutaneous drainage for septic complications coexisted with COVID-19
The resulting tissue hypoxia and increased inflammation secondary to severe coronavirus disease 2019 (COVID-19) combined with viral load, and other baseline risk factors contribute to an increased risk of severe sepsis or co-existed septic condition exaggeration. To describe the clinical, radiological, and laboratory characteristics of a small cohort of patients infected by severe acute respiratory syndrome coronavirus 2 who underwent percutaneous drainage for septic complications and their post-procedural outcomes. This retrospective study consisted of 11 patients who were confirmed to have COVID-19 by RT-PCR test and required drain placement for septic complications. The mean age ± SD of the patients was 48.5 ± 14 years (range 30-72 years). Three patients underwent cholecystostomy for acute acalculous cholecystitis. Percutaneous drainage was performed in seven patients; two peripancreatic collections; two infected leaks after hepatic resection; one recurrent hepatic abscess, one psoas abscess and one lumbar abscess. One patient underwent a percutaneous nephrostomy for acute pyelonephritis. Technical success was achieved in 100% of patients, while clinical success was achieved in 4 out of 11 patients (36.3%). Six patients (54.5%) died despite proper percutaneous drainage and adequate antibiotic coverage. One patient (9%) needed operative intervention. Two patients (18.2%) had two drainage procedures to drain multiple fluid collections. Two patients (18.2%) had repeat drainage procedures due to recurrent fluid collections. The average volume of the drained fluid immediately after tube insertion was 85 mL. Follow-up scans show a reduction of the retained content and associated inflammatory changes after tube insertion in all patients. There was no significant statistical difference (P = 0.6 and 0.4) between the mean of WBCs and neutrophils count before drainage and seven days after drainage. The lymphocyte count shows significant increased seven days after drainage (P = 0.03). In this study, patients having septic complications associated with COVID-19 showed relatively poor clinical outcomes despite technically successful percutaneous drainage.
- 28 April 2022
- Published by Baishideng Publishing Group Inc. in World Journal of Radiology
- Vol. 14 (4) , 91-103
Open AccessOutcome of percutaneous drainage for septic complications coexisted with COVID-19
The resulting tissue hypoxia and increased inflammation secondary to severe coronavirus disease 2019 (COVID-19) combined with viral load, and other baseline risk factors contribute to an increased risk of severe sepsis or co-existed septic condition exaggeration. To describe the clinical, radiological, and laboratory characteristics of a small cohort of patients infected by severe acute respiratory syndrome coronavirus 2 who underwent percutaneous drainage for septic complications and their post-procedural outcomes. This retrospective study consisted of 11 patients who were confirmed to have COVID-19 by RT-PCR test and required drain placement for septic complications. The mean age ± SD of the patients was 48.5 ± 14 years (range 30-72 years). Three patients underwent cholecystostomy for acute acalculous cholecystitis. Percutaneous drainage was performed in seven patients; two peripancreatic collections; two infected leaks after hepatic resection; one recurrent hepatic abscess, one psoas abscess and one lumbar abscess. One patient underwent a percutaneous nephrostomy for acute pyelonephritis. Technical success was achieved in 100% of patients, while clinical success was achieved in 4 out of 11 patients (36.3%). Six patients (54.5%) died despite proper percutaneous drainage and adequate antibiotic coverage. One patient (9%) needed operative intervention. Two patients (18.2%) had two drainage procedures to drain multiple fluid collections. Two patients (18.2%) had repeat drainage procedures due to recurrent fluid collections. The average volume of the drained fluid immediately after tube insertion was 85 mL. Follow-up scans show a reduction of the retained content and associated inflammatory changes after tube insertion in all patients. There was no significant statistical difference (P = 0.6 and 0.4) between the mean of WBCs and neutrophils count before drainage and seven days after drainage. The lymphocyte count shows significant increased seven days after drainage (P = 0.03). In this study, patients having septic complications associated with COVID-19 showed relatively poor clinical outcomes despite technically successful percutaneous drainage.
- Open Access
- 2 March 2022
- Published by Termedia Sp. z.o.o. in Polish Journal of Radiology
- Vol. 87 (1) , 126-140
Diagnostic performance of chest computed tomography for COVID-19 in children: a systematic review and meta-analysis of clinical and computed tomography features in 987 patients
Purpose The outbreak of a new coronavirus is still spreading worldwide, affecting children and adults. However, COVID-19 in children shows distinctive characteristics in clinical and radiological presentation. We aimed to assess the diagnostic performance of chest CT and clarify the...
- 2 March 2022
- Published by Termedia Sp. z.o.o. in Polish Journal of Radiology
- Vol. 87 (1) , 126-140
Open AccessDiagnostic performance of chest computed tomography for COVID-19 in children: a systematic review and meta-analysis of clinical and computed tomography features in 987 patients
Purpose The outbreak of a new coronavirus is still spreading worldwide, affecting children and adults. However, COVID-19 in children shows distinctive characteristics in clinical and radiological presentation. We aimed to assess the diagnostic performance of chest CT and clarify the...