Abhishek Midya
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Abhishek Midya has a total of 62 co-authors. Here are the top co-authors by number of shared publications:
- Jayasree Chakraborty
Hepatopancreatobiliary Service, Department of Surgery, Memorial Sloan Kettering Cancer Center, United States
3 shared publications - Anant Madabhushi
Department of Biomedical Engineering, Emory University, Atlanta, GA
2 shared publications Mithat Gönen
Department of Epidemiology & Bio-statistics, Memorial Sloan Kettering Cancer Center, New York, NY, USA
2 shared publications- Richard Kinh Gian Do
Department of Radiology Memorial Sloan Kettering Cancer Center New York New York USA
2 shared publications - Abel Abraham
Northeast Ohio Medical University, Rootstown (A.A.).
1 shared publication - Aleksandar Izda
Cleveland Clinic Lerner College of Medicine
1 shared publication
Latest Publications
- Open Access
- 1 July 2025
- Published by Wolters Kluwer Health in JU Open Plus
- Vol. 3 (7)
Population-Specific Radiomics From Biparametric Magnetic Resonance Imaging Improves Prostate Cancer Risk Stratification in African American Men
Purpose: To quantify population-specific differences in prostate cancer (PCa) presentation between African American (AA) and White (W) men on MRI using radiomics. Materials and Methods: We identified N = 149 men with PCa who underwent 3T MRI, a confirmatory biopsy and for whom self-reported race was available. Patient studies were partitioned into training (DTr) and hold-out test set (DTe). Three hundred radiomic features quantifying textural patterns were extracted from radiologist delineated PCa regions of interest (ROI) on biparametric MRI. Features with significant differences (P < .05) between clinically significant (csPCa) and insignificant (ciPCa) PCa were identified. Machine learning models were trained separately for AA and W men (CAA, CW) on DTr to distinguish csPCa and ciPCa. Validation on DTe was assessed for AUC and compared against a population agnostic model (CPA) in combination with clinical parameters (age, PSA, Prostate Imaging Reporting and Diagnostic System and tumor volume). Results: Radiomic features from PCa ROIs on biparametric MRI associated with csPCa were observed to be different in AA compared with W men, especially in the peritumoral region. Population-specific radiomic models outperformed similarly trained CPA models (AUC = 0.84, 0.57 with CAA, CPA; P < .05) in AA men on DTe. Similar findings were observed for W men (AUC = 0.71, 0.60 with CW, CPA; P < .05). Integrating clinical and radiomics further improved the risk stratification for AA men (AUC = 0.90) and W men (AUC = 0.75). Conclusions: Accounting for population-specific differences in radiomics may enable improved PCa risk stratification at MRI among AA men compared with a population agnostic approach.
- 1 July 2025
- Published by Wolters Kluwer Health in JU Open Plus
- Vol. 3 (7)
Open AccessPopulation-Specific Radiomics From Biparametric Magnetic Resonance Imaging Improves Prostate Cancer Risk Stratification in African American Men
Purpose: To quantify population-specific differences in prostate cancer (PCa) presentation between African American (AA) and White (W) men on MRI using radiomics. Materials and Methods: We identified N = 149 men with PCa who underwent 3T MRI, a confirmatory biopsy and for whom self-reported race was available. Patient studies were partitioned into training (DTr) and hold-out test set (DTe). Three hundred radiomic features quantifying textural patterns were extracted from radiologist delineated PCa regions of interest (ROI) on biparametric MRI. Features with significant differences (P < .05) between clinically significant (csPCa) and insignificant (ciPCa) PCa were identified. Machine learning models were trained separately for AA and W men (CAA, CW) on DTr to distinguish csPCa and ciPCa. Validation on DTe was assessed for AUC and compared against a population agnostic model (CPA) in combination with clinical parameters (age, PSA, Prostate Imaging Reporting and Diagnostic System and tumor volume). Results: Radiomic features from PCa ROIs on biparametric MRI associated with csPCa were observed to be different in AA compared with W men, especially in the peritumoral region. Population-specific radiomic models outperformed similarly trained CPA models (AUC = 0.84, 0.57 with CAA, CPA; P < .05) in AA men on DTe. Similar findings were observed for W men (AUC = 0.71, 0.60 with CW, CPA; P < .05). Integrating clinical and radiomics further improved the risk stratification for AA men (AUC = 0.90) and W men (AUC = 0.75). Conclusions: Accounting for population-specific differences in radiomics may enable improved PCa risk stratification at MRI among AA men compared with a population agnostic approach.
- Open Access
- 1 December 2024
- Published by Wolters Kluwer Health in Circulation: Arrhythmia and Electrophysiology
- Vol. 17 (12) , e012679
Artificial Intelligence–Based Feature Analysis of Pulmonary Vein Morphology on Computed Tomography Scans and Risk of Atrial Fibrillation Recurrence After Catheter Ablation: A Multi-Site Study
BACKGROUND: Atrial fibrillation (AF) recurrence is common after catheter ablation. Pulmonary vein (PV) isolation is the cornerstone of AF ablation, but PV remodeling has been associated with the risk of AF recurrence. We aimed to evaluate whether artificial intelligence–based morphological features of primary and secondary PV branches on computed tomography images are associated with AF recurrence post-ablation. METHODS: Two artificial intelligence models were trained for the segmentation of computed tomography images, enabling the isolation of PV branches. Patients from Cleveland Clinic (N=135) and Vanderbilt University (N=594) were combined and divided into 2 sets for training and cross-validation (D 1 , n=218) and internal testing (D 2 , n=511). An independent validation set (D 3 , N=80) was obtained from University Hospitals of Cleveland. We extracted 48 fractal-based and 12 shape-based radiomic features from primary and secondary PV branches of patients with AF recurrence (AF+) and without recurrence after catheter ablation of AF (AF-). To predict AFrecurrence, 3 Gradient Boosting classification models based on significant features from primary (M p ), secondary (M s ), and combined (M c ) PV branches were built. RESULTS: Features relating to primary PVs were found to be associated with AF recurrence. The M p classifier achieved area under the curve values of 0.73, 0.71, and 0.70 across the 3 datasets. AF+ cases exhibited greater surface complexity in their primary PV area, as evidenced by higher fractal dimension values compared with AF- cases. The M s classifier results revealed a weaker association with AF+, suggesting higher relevance to AF recurrence post-ablation from primary PV branch morphology. CONCLUSIONS: This largest multi-institutional study to date revealed associations between artificial intelligence–extracted morphological features of the primary PV branches with AF recurrence in 809 patients from 3 sites. Future work will focus on enhancing the predictive ability of the classifier by integrating clinical, structural, and morphological features, including left atrial appendage and left atrium–related characteristics.
- 1 December 2024
- Published by Wolters Kluwer Health in Circulation: Arrhythmia and Electrophysiology
- Vol. 17 (12) , e012679
Open AccessArtificial Intelligence–Based Feature Analysis of Pulmonary Vein Morphology on Computed Tomography Scans and Risk of Atrial Fibrillation Recurrence After Catheter Ablation: A Multi-Site Study
BACKGROUND: Atrial fibrillation (AF) recurrence is common after catheter ablation. Pulmonary vein (PV) isolation is the cornerstone of AF ablation, but PV remodeling has been associated with the risk of AF recurrence. We aimed to evaluate whether artificial intelligence–based morphological features of primary and secondary PV branches on computed tomography images are associated with AF recurrence post-ablation. METHODS: Two artificial intelligence models were trained for the segmentation of computed tomography images, enabling the isolation of PV branches. Patients from Cleveland Clinic (N=135) and Vanderbilt University (N=594) were combined and divided into 2 sets for training and cross-validation (D 1 , n=218) and internal testing (D 2 , n=511). An independent validation set (D 3 , N=80) was obtained from University Hospitals of Cleveland. We extracted 48 fractal-based and 12 shape-based radiomic features from primary and secondary PV branches of patients with AF recurrence (AF+) and without recurrence after catheter ablation of AF (AF-). To predict AFrecurrence, 3 Gradient Boosting classification models based on significant features from primary (M p ), secondary (M s ), and combined (M c ) PV branches were built. RESULTS: Features relating to primary PVs were found to be associated with AF recurrence. The M p classifier achieved area under the curve values of 0.73, 0.71, and 0.70 across the 3 datasets. AF+ cases exhibited greater surface complexity in their primary PV area, as evidenced by higher fractal dimension values compared with AF- cases. The M s classifier results revealed a weaker association with AF+, suggesting higher relevance to AF recurrence post-ablation from primary PV branch morphology. CONCLUSIONS: This largest multi-institutional study to date revealed associations between artificial intelligence–extracted morphological features of the primary PV branches with AF recurrence in 809 patients from 3 sites. Future work will focus on enhancing the predictive ability of the classifier by integrating clinical, structural, and morphological features, including left atrial appendage and left atrium–related characteristics.
- 23 February 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 27 (5) , 2456-2464
Computerized Diagnosis of Liver Tumors From CT Scans Using a Deep Neural Network Approach
The liver is a frequent site of benign and malignant, primary and metastatic tumors. Hepatocellular carcinoma (HCC) and intrahepatic cholangiocarcinoma (ICC) are the most common primary liver cancers, and colorectal liver metastasis (CRLM) is the most common secondary liver cancer. Although the imaging characteristic of these tumors is central to optimal clinical management, it relies on imaging features that are often non-specific, overlap, and are subject to inter-observer variability. Thus, in this study, we aimed to categorize liver tumors automatically from CT scans using a deep learning approach that objectively extracts discriminating features not visible to the naked eye. Specifically, we used a modified Inception v3 network-based classification model to classify HCC, ICC, CRLM, and benign tumors from pretreatment portal venous phase computed tomography (CT) scans. Using a multi-institutional dataset of 814 patients, this method achieved an overall accuracy rate of 96%, with sensitivity rates of 96%, 94%, 99%, and 86% for HCC, ICC, CRLM, and benign tumors, respectively, using an independent dataset. These results demonstrate the feasibility of the proposed computer-assisted system as a novel non-invasive diagnostic tool to classify the most common liver tumors objectively.
- 23 February 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 27 (5) , 2456-2464
Computerized Diagnosis of Liver Tumors From CT Scans Using a Deep Neural Network Approach
The liver is a frequent site of benign and malignant, primary and metastatic tumors. Hepatocellular carcinoma (HCC) and intrahepatic cholangiocarcinoma (ICC) are the most common primary liver cancers, and colorectal liver metastasis (CRLM) is the most common secondary liver cancer. Although the imaging characteristic of these tumors is central to optimal clinical management, it relies on imaging features that are often non-specific, overlap, and are subject to inter-observer variability. Thus, in this study, we aimed to categorize liver tumors automatically from CT scans using a deep learning approach that objectively extracts discriminating features not visible to the naked eye. Specifically, we used a modified Inception v3 network-based classification model to classify HCC, ICC, CRLM, and benign tumors from pretreatment portal venous phase computed tomography (CT) scans. Using a multi-institutional dataset of 814 patients, this method achieved an overall accuracy rate of 96%, with sensitivity rates of 96%, 94%, 99%, and 86% for HCC, ICC, CRLM, and benign tumors, respectively, using an independent dataset. These results demonstrate the feasibility of the proposed computer-assisted system as a novel non-invasive diagnostic tool to classify the most common liver tumors objectively.
- 9 December 2019
- Published by World Scientific Pub Co Pte Ltd in Journal of Circuits, Systems and Computers
- Vol. 29 (10) , 2050156
Multi-Resolution Analysis of Edge-Texture Features for Mammographic Mass Classification
- 9 December 2019
- Published by World Scientific Pub Co Pte Ltd in Journal of Circuits, Systems and Computers
- Vol. 29 (10) , 2050156
Multi-Resolution Analysis of Edge-Texture Features for Mammographic Mass Classification
- 15 February 2018
- Published by SPIE-Intl Soc Optical Eng in Journal of Medical Imaging
- Vol. 5 (01) , 011020-15
Influence of CT acquisition and reconstruction parameters on radiomic feature reproducibility
High-dimensional imaging features extracted from diagnostic imaging, called radiomics, are increasingly reported for diagnosis, prognosis, and response to therapy. Establishing the sensitivity of radiomic features to variation in scan protocols is necessary because acquisition and reconstruction parameters can vary widely across and within institutions. Our objective was to assess the reproducibility of radiomic features derived from computed tomography (CT) images by varying tube current (mA), noise index, and reconstruction [adaptive statistical iterative reconstruction (ASiR)], parameters increasingly varied by institutions seeking to reduce radiation dose in their patients. We extracted radiomic features from CT images of a uniform water phantom, anthropomorphic phantom, and a human scan. Scans were acquired from the phantoms with six tube currents (50, 100, 200, 300, 400, and 500 mA) and five noise index levels (12, 14, 16, 18, and 20), respectively. Scans of the phantoms and patient were reconstructed from 0% ASiR (i.e., filtered back projection) to 100% ASiR in increments of 10%. Two hundred and forty-eight well-known radiomic features were extracted from all scans. The concordance correlation coefficient was used to assess agreement of features. Our analysis suggests that image acquisition parameters (tube current, noise index) as well as the reconstruction technique strongly influence radiomic feature reproducibility and demonstrate a subset of reproducible features potentially usable in clinical practice.
- 15 February 2018
- Published by SPIE-Intl Soc Optical Eng in Journal of Medical Imaging
- Vol. 5 (01) , 011020-15
Influence of CT acquisition and reconstruction parameters on radiomic feature reproducibility
High-dimensional imaging features extracted from diagnostic imaging, called radiomics, are increasingly reported for diagnosis, prognosis, and response to therapy. Establishing the sensitivity of radiomic features to variation in scan protocols is necessary because acquisition and reconstruction parameters can vary widely across and within institutions. Our objective was to assess the reproducibility of radiomic features derived from computed tomography (CT) images by varying tube current (mA), noise index, and reconstruction [adaptive statistical iterative reconstruction (ASiR)], parameters increasingly varied by institutions seeking to reduce radiation dose in their patients. We extracted radiomic features from CT images of a uniform water phantom, anthropomorphic phantom, and a human scan. Scans were acquired from the phantoms with six tube currents (50, 100, 200, 300, 400, and 500 mA) and five noise index levels (12, 14, 16, 18, and 20), respectively. Scans of the phantoms and patient were reconstructed from 0% ASiR (i.e., filtered back projection) to 100% ASiR in increments of 10%. Two hundred and forty-eight well-known radiomic features were extracted from all scans. The concordance correlation coefficient was used to assess agreement of features. Our analysis suggests that image acquisition parameters (tube current, noise index) as well as the reconstruction technique strongly influence radiomic feature reproducibility and demonstrate a subset of reproducible features potentially usable in clinical practice.
- 1 January 2015
- Published by Elsevier in Biomedical Signal Processing and Control
- Vol. 15, 80-89
Detection of the nipple in mammograms with Gabor filters and the Radon transform
- 1 January 2015
- Published by Elsevier in Biomedical Signal Processing and Control
- Vol. 15, 80-89
Detection of the nipple in mammograms with Gabor filters and the Radon transform
- 19 November 2013
- Published by Elsevier in Signal Processing: Image Communication
- Vol. 29 (1) , 37-48
Scene content driven FEC allocation for video streaming
- 19 November 2013
- Published by Elsevier in Signal Processing: Image Communication
- Vol. 29 (1) , 37-48
Scene content driven FEC allocation for video streaming
- 1 November 2013
- Published by Springer Nature in Multimedia Tools and Applications
- Vol. 74 (6) , 2033-2054
Switchable video error concealment using encoder driven scene transition detection and edge preserving SEC
- 1 November 2013
- Published by Springer Nature in Multimedia Tools and Applications
- Vol. 74 (6) , 2033-2054
Switchable video error concealment using encoder driven scene transition detection and edge preserving SEC