Zuofeng Xu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Zuofeng Xu has a total of 108 co-authors. Here are the top co-authors by number of shared publications:
Danni He
Department of Medical Ultrasound, The Seventh Affiliated Hospital Sun Yat‐Sen University Shenzhen Guangdong China
5 shared publicationsJiachun Li
Department of Orthopaedics, the Seventh Affiliated Hospital of Sun Yat-sen University, Shenzhen, China
5 shared publicationsQiao Ji
5 shared publicationsRenjie Li
Department of Medical Ultrasound, The Seventh Affiliated Hospital Sun Yat‐Sen University Shenzhen Guangdong China
5 shared publicationsXiang Li
4 shared publications- Xizhe Liu
Guangdong Provincial Key Laboratory of Orthopedics and Traumatology, The First Affiliated Hospital of Sun Yat-Sen University, Guangzhou, China
4 shared publications
Latest Publications
- 29 July 2026
- Published by Elsevier in Ultrasound in Medicine & Biology
- Vol. 52 (10) , 2195-2203
Temporal Changes in Shear Wave Elastography and Doppler Ultrasound Parameters for Assessing Erectile Dysfunction
- 29 July 2026
- Published by Elsevier in Ultrasound in Medicine & Biology
- Vol. 52 (10) , 2195-2203
Temporal Changes in Shear Wave Elastography and Doppler Ultrasound Parameters for Assessing Erectile Dysfunction
- 31 May 2026
- Published by Wiley in Journal of Clinical Ultrasound
- Vol. 54 (8) , 2041-2045
Contrast‐Enhanced Ultrasound Successfully Diagnoses a Rare Case of Coexisting Colorectal Cancer Liver Metastasis and Hepatocellular Carcinoma: A Case Report
Colorectal cancer liver metastasis (CRLM) with concomitant hepatocellular carcinoma (HCC) in a single patient has not been previously reported. We present a case of a 57‐year‐old Asian male with a rectal mass and synchronous, radiologically distinct multiple liver lesions. Contrast‐enhanced ultrasound (CEUS) characterized the liver lesions as suggestive of both CRLM and concomitant HCC, which was later histologically confirmed by ultrasound‐guided biopsy. This case underscores the significant diagnostic value of CEUS in differentiating complex multifocal liver lesions and the critical role of targeted biopsy for definitive diagnosis.
- 31 May 2026
- Published by Wiley in Journal of Clinical Ultrasound
- Vol. 54 (8) , 2041-2045
Contrast‐Enhanced Ultrasound Successfully Diagnoses a Rare Case of Coexisting Colorectal Cancer Liver Metastasis and Hepatocellular Carcinoma: A Case Report
Colorectal cancer liver metastasis (CRLM) with concomitant hepatocellular carcinoma (HCC) in a single patient has not been previously reported. We present a case of a 57‐year‐old Asian male with a rectal mass and synchronous, radiologically distinct multiple liver lesions. Contrast‐enhanced ultrasound (CEUS) characterized the liver lesions as suggestive of both CRLM and concomitant HCC, which was later histologically confirmed by ultrasound‐guided biopsy. This case underscores the significant diagnostic value of CEUS in differentiating complex multifocal liver lesions and the critical role of targeted biopsy for definitive diagnosis.
- Open Access
- 1 April 2026
- Published by AME Publishing Company in Quantitative Imaging in Medicine and Surgery
- Vol. 16 (4) , 277
Factors predicting the risk of breast cancer: construction and validation of a nomogram model
Background: A simple and practicable strategy for predicting the risk of breast cancer (BC) urgently needs to be established. This study aimed to construct a nomogram model based on age and ultrasound (US) features to predict BC. Methods: Consecutive adult females with a breast mass who underwent breast US followed by biopsy or surgery (Breast Imaging Reporting and Data System (BI-RADS) categories III–V) or who received follow-up US more than 6 months after the initial US (BI-RADS category II) from August 2020 to November 2023 were enrolled in this prospective multicenter study. The participants were allocated to three groups (the training set, internal validation set, and external validation set). A logistic regression analysis of the training set was performed to identify the independent variables associated with BC, based on which the breast nomogram model (B-NM) was constructed. The performance of the B-NM was evaluated using the area under the curve (AUC) of the receiver operating characteristic curve and calibration diagrams. Results: The training set comprised 306 females (43.0±11.9 years), the internal validation set comprised 45 females (46.0±12.6 years), and the external validation set comprised 114 females (40.6±11.4 years). Age and four US variables (mass size, orientation, margin, and vascularity) were found to be independently associated with BC. The B-NM combining these variables demonstrated relatively good performance {AUC [95% confidence interval (CI)]: 0.914 (0.882–0.946) vs. 0.905 (0.827–0.982) vs. 0.846 (0.750–0.940)} in the training, internal, and external validation sets, respectively. The calibration diagram showed that the nomogram’s predicted probabilities were highly consistent with the observed values. Conclusions: The B-NM incorporating age and US variables demonstrated favorable discrimination and calibration in predicting the risk of BC.
- 1 April 2026
- Published by AME Publishing Company in Quantitative Imaging in Medicine and Surgery
- Vol. 16 (4) , 277
Open AccessFactors predicting the risk of breast cancer: construction and validation of a nomogram model
Background: A simple and practicable strategy for predicting the risk of breast cancer (BC) urgently needs to be established. This study aimed to construct a nomogram model based on age and ultrasound (US) features to predict BC. Methods: Consecutive adult females with a breast mass who underwent breast US followed by biopsy or surgery (Breast Imaging Reporting and Data System (BI-RADS) categories III–V) or who received follow-up US more than 6 months after the initial US (BI-RADS category II) from August 2020 to November 2023 were enrolled in this prospective multicenter study. The participants were allocated to three groups (the training set, internal validation set, and external validation set). A logistic regression analysis of the training set was performed to identify the independent variables associated with BC, based on which the breast nomogram model (B-NM) was constructed. The performance of the B-NM was evaluated using the area under the curve (AUC) of the receiver operating characteristic curve and calibration diagrams. Results: The training set comprised 306 females (43.0±11.9 years), the internal validation set comprised 45 females (46.0±12.6 years), and the external validation set comprised 114 females (40.6±11.4 years). Age and four US variables (mass size, orientation, margin, and vascularity) were found to be independently associated with BC. The B-NM combining these variables demonstrated relatively good performance {AUC [95% confidence interval (CI)]: 0.914 (0.882–0.946) vs. 0.905 (0.827–0.982) vs. 0.846 (0.750–0.940)} in the training, internal, and external validation sets, respectively. The calibration diagram showed that the nomogram’s predicted probabilities were highly consistent with the observed values. Conclusions: The B-NM incorporating age and US variables demonstrated favorable discrimination and calibration in predicting the risk of BC.
- 25 February 2026
- Published by Elsevier in Ultrasound in Medicine & Biology
- Vol. 52 (4) , 882-888
Ultrasonography-Based Application of Node-RADS in Differentiating Malignant and Benign Superficial Lymph Nodes: A Retrospective Study
- 25 February 2026
- Published by Elsevier in Ultrasound in Medicine & Biology
- Vol. 52 (4) , 882-888
Ultrasonography-Based Application of Node-RADS in Differentiating Malignant and Benign Superficial Lymph Nodes: A Retrospective Study
- 22 August 2025
- Published by Elsevier in Ultrasound in Medicine & Biology
- Vol. 51 (11) , 2049-2057
A Point-based Risk Stratification System for Breast Masses: Potential Alternative to the Existing ACR BIRADS
- 22 August 2025
- Published by Elsevier in Ultrasound in Medicine & Biology
- Vol. 51 (11) , 2049-2057
A Point-based Risk Stratification System for Breast Masses: Potential Alternative to the Existing ACR BIRADS
- 26 November 2024
- Published by Elsevier in European Journal of Obstetrics & Gynecology and Reproductive Biology
- Vol. 305, 48-55
Constructing small for gestational age prediction models: A retrospective machine learning study
- 26 November 2024
- Published by Elsevier in European Journal of Obstetrics & Gynecology and Reproductive Biology
- Vol. 305, 48-55
Constructing small for gestational age prediction models: A retrospective machine learning study
- Open Access
- 12 July 2024
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 25 (1) , 1-11
Preliminarily exploring the intraoperative ultrasonography characteristics of patients with degenerative cervical myelopathy
Background: How to quickly read and interpret intraoperative ultrasound (IOUS) images of patients with degenerative cervical myelopathy (DCM) to obtain meaningful information? Few studies have systematically explored this topic. Purpose: To systematically and comprehensively explore the IOUS characteristics of patients with DCM. Materials and methods: This single-center study retrospectively included patients with DCM who underwent French-door laminoplasty (FDL) with IOUS guidance from October 2019 to March 2022. One-way ANOVA and Pearson’s /Spearman’s correlation analysis were used to analyze the correlations between the cross-sectional area of the spinal cord (SC) and individual characteristics; the relationships between the morphology, echogenicity, pulsation, decompression statuses, compression types of SC, location of the spinal cord central echo complex (SCCEC) and the disease severity (the preoperative Japanese Orthopedic Association score, preJOA score); the difference of the spinal cord pulsation amplitude(SCPA) and the SCCEC forward movement rate (FMR) between the compressed areas(CAs) and the non-compressed areas (NCAs). Results: A total of 38 patients were successfully enrolled (30 males and 8 females), and the mean age was 57.05 ± 10.29 (27–75) years. The cross-sectional area of the SC was negatively correlated with age (r = − 0.441, p = 0.006). The preJOA score was significantly lower in the heterogeneous group than in the homogeneous group (P < 0.05, p = 0.005). The hyperechoic area (HEA) was negatively while the SCCEC FMR was positively correlated with the preJOA score (r = − 0.334, p = 0.020; r = 0.286, p = 0.041). The SCCEC FMR and SCPA in CAs were significantly greater than those in NCAs (p < 0.05, p = 0.007; P < 0.001, P = 0.000). Conclusion: The cross-sectional area of the SC decreases with age in adults. More changes in intramedullary echogenicity and less moving forward of the SCCEC often indicate poor SC status, and the SCCEC FMR and SCPA are more pronounced in CAs.
- 12 July 2024
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 25 (1) , 1-11
Open AccessPreliminarily exploring the intraoperative ultrasonography characteristics of patients with degenerative cervical myelopathy
Background: How to quickly read and interpret intraoperative ultrasound (IOUS) images of patients with degenerative cervical myelopathy (DCM) to obtain meaningful information? Few studies have systematically explored this topic. Purpose: To systematically and comprehensively explore the IOUS characteristics of patients with DCM. Materials and methods: This single-center study retrospectively included patients with DCM who underwent French-door laminoplasty (FDL) with IOUS guidance from October 2019 to March 2022. One-way ANOVA and Pearson’s /Spearman’s correlation analysis were used to analyze the correlations between the cross-sectional area of the spinal cord (SC) and individual characteristics; the relationships between the morphology, echogenicity, pulsation, decompression statuses, compression types of SC, location of the spinal cord central echo complex (SCCEC) and the disease severity (the preoperative Japanese Orthopedic Association score, preJOA score); the difference of the spinal cord pulsation amplitude(SCPA) and the SCCEC forward movement rate (FMR) between the compressed areas(CAs) and the non-compressed areas (NCAs). Results: A total of 38 patients were successfully enrolled (30 males and 8 females), and the mean age was 57.05 ± 10.29 (27–75) years. The cross-sectional area of the SC was negatively correlated with age (r = − 0.441, p = 0.006). The preJOA score was significantly lower in the heterogeneous group than in the homogeneous group (P < 0.05, p = 0.005). The hyperechoic area (HEA) was negatively while the SCCEC FMR was positively correlated with the preJOA score (r = − 0.334, p = 0.020; r = 0.286, p = 0.041). The SCCEC FMR and SCPA in CAs were significantly greater than those in NCAs (p < 0.05, p = 0.007; P < 0.001, P = 0.000). Conclusion: The cross-sectional area of the SC decreases with age in adults. More changes in intramedullary echogenicity and less moving forward of the SCCEC often indicate poor SC status, and the SCCEC FMR and SCPA are more pronounced in CAs.
- Open Access
- 21 September 2023
- Published by Springer Nature in Journal of Materials Science: Materials in Medicine
- Vol. 34 (10) , 1-10
Tumor-microenvironment responsive nano-carrier system for therapy of prostate cancer
Poor selectivity, low bioavailability and serious systemic side-effects have limited the application of traditional chemotherapy method for treatment of prostate cancer. Stimuli-responsive drug delivery systems for chemotherapy are mainly based on the unique characteristics of tumor microenvironment. In this study, the GSH-sensitive poly-TTG-SS@DTX NPs (DTX-loaded poly-Tetraethylene glycol nanoparticles) were designed and synthesized, which were characterized with nanosized diameter (92.8 ± 2.5 nm) and negatively charged surface charge (−24.7 ± 5.56 mV). Experiments in vitro showed that poly-TTG-SS@DTX NPs had good compatibility to healthy cells and strong anti-tumor effect because of rapid and sustained drug release of DTX from poly-TTG-SS@DTX NPs under the tumor-microenvironment condition. The cellular activity remained greater than 90% when the concentration of poly-TTG-SS NPs reached as high as 100 µg/mL treated on healthy cells. The killing effect of DTX loading NPs group on C4-2 cells was stronger than that of free anti-tumor drug and free DTX combined with the blank nano-carrier (25.21% vs 19.93% vs 20.96%). In conclusion, poly-TTG-SS@DTX NPs may provide a new therapeutic strategy for the chemotherapy of prostate cancer. Graphical Abstract
- 21 September 2023
- Published by Springer Nature in Journal of Materials Science: Materials in Medicine
- Vol. 34 (10) , 1-10
Open AccessTumor-microenvironment responsive nano-carrier system for therapy of prostate cancer
Poor selectivity, low bioavailability and serious systemic side-effects have limited the application of traditional chemotherapy method for treatment of prostate cancer. Stimuli-responsive drug delivery systems for chemotherapy are mainly based on the unique characteristics of tumor microenvironment. In this study, the GSH-sensitive poly-TTG-SS@DTX NPs (DTX-loaded poly-Tetraethylene glycol nanoparticles) were designed and synthesized, which were characterized with nanosized diameter (92.8 ± 2.5 nm) and negatively charged surface charge (−24.7 ± 5.56 mV). Experiments in vitro showed that poly-TTG-SS@DTX NPs had good compatibility to healthy cells and strong anti-tumor effect because of rapid and sustained drug release of DTX from poly-TTG-SS@DTX NPs under the tumor-microenvironment condition. The cellular activity remained greater than 90% when the concentration of poly-TTG-SS NPs reached as high as 100 µg/mL treated on healthy cells. The killing effect of DTX loading NPs group on C4-2 cells was stronger than that of free anti-tumor drug and free DTX combined with the blank nano-carrier (25.21% vs 19.93% vs 20.96%). In conclusion, poly-TTG-SS@DTX NPs may provide a new therapeutic strategy for the chemotherapy of prostate cancer. Graphical Abstract
- 14 September 2023
- Published by Springer Nature in European Radiology
- Vol. 34 (4) , 2297-2309
Predictive value of intraoperative contrast-enhanced ultrasound in functional recovery of non-traumatic cervical spinal cord injury
Objectives To evaluate the ability of intraoperative CEUS to predict neurological recovery in patients with degenerative cervical myelopathy (DCM). Methods Twenty-six patients with DCM who underwent laminoplasty and intraoperative ultrasound (IOUS) were included in this prospective study. The modified Japanese Orthopaedic Association (mJOA) scores and MRI were assessed before surgery and 12 months postoperatively. The anteroposterior diameter (APD), maximum spinal cord compression (MSCC), and area of signal changes in the cord at the compressed and normal levels were measured and compared using MRI and IOUS. Conventional blood flow and CEUS indices (time to peak, ascending slope, peak intensity (PI), and area under the curve (AUC)) at different levels during IOUS were calculated and analysed. Correlations between all indicators and the neurological recovery rate were evaluated. Results All patients underwent IOUS and intraoperative CEUS, and the total recovery rate was 50.7 ± 33.3%. APD and MSCC improved significantly (p < 0.01). The recovery rate of the hyperechoic lesion group was significantly worse than that of the isoechoic group (p = 0.016). 22 patients were analysed by contrast analysis software. PI was higher in the compressed zone than in the normal zone (24.58 ± 3.19 versus 22.43 ± 2.39, p = 0.019). ΔPI compress-normal and ΔAUC compress-normal of the hyperechoic lesion group were significantly higher than those of the isoechoic group (median 2.19 versus 0.55, p = 0.017; 135.7 versus 21.54, p = 0.014, respectively), and both indices were moderately negatively correlated with the recovery rate (r = − 0.463, p = 0.030; r = − 0.466, p = 0.029). Conclusions Signal changes and microvascular perfusion evaluated using CEUS during surgery are valuable predictors of cervical myelopathy prognosis. Clinical relevance statement In the spinal cord compression area of degenerative cervical myelopathy, especially in the hyperechoic lesions, intraoperative CEUS showed more significant contrast agent perfusion than in the normal area, and the degree was negatively correlated with the neurological prognosis. Key Points • Recovery rates in patients with hyperechoic findings were lower than those of patients without lesions detected during intraoperative ultrasound. • The peak intensity of CEUS was higher in compressed zones than in the normal parts of the spinal cord. • Quantitative CEUS comparisons of the peak intensity and area under the curve at the compressed and normal levels of the spinal cord revealed differences that were inversely correlated to the recovery rate.
- 14 September 2023
- Published by Springer Nature in European Radiology
- Vol. 34 (4) , 2297-2309
Predictive value of intraoperative contrast-enhanced ultrasound in functional recovery of non-traumatic cervical spinal cord injury
Objectives To evaluate the ability of intraoperative CEUS to predict neurological recovery in patients with degenerative cervical myelopathy (DCM). Methods Twenty-six patients with DCM who underwent laminoplasty and intraoperative ultrasound (IOUS) were included in this prospective study. The modified Japanese Orthopaedic Association (mJOA) scores and MRI were assessed before surgery and 12 months postoperatively. The anteroposterior diameter (APD), maximum spinal cord compression (MSCC), and area of signal changes in the cord at the compressed and normal levels were measured and compared using MRI and IOUS. Conventional blood flow and CEUS indices (time to peak, ascending slope, peak intensity (PI), and area under the curve (AUC)) at different levels during IOUS were calculated and analysed. Correlations between all indicators and the neurological recovery rate were evaluated. Results All patients underwent IOUS and intraoperative CEUS, and the total recovery rate was 50.7 ± 33.3%. APD and MSCC improved significantly (p < 0.01). The recovery rate of the hyperechoic lesion group was significantly worse than that of the isoechoic group (p = 0.016). 22 patients were analysed by contrast analysis software. PI was higher in the compressed zone than in the normal zone (24.58 ± 3.19 versus 22.43 ± 2.39, p = 0.019). ΔPI compress-normal and ΔAUC compress-normal of the hyperechoic lesion group were significantly higher than those of the isoechoic group (median 2.19 versus 0.55, p = 0.017; 135.7 versus 21.54, p = 0.014, respectively), and both indices were moderately negatively correlated with the recovery rate (r = − 0.463, p = 0.030; r = − 0.466, p = 0.029). Conclusions Signal changes and microvascular perfusion evaluated using CEUS during surgery are valuable predictors of cervical myelopathy prognosis. Clinical relevance statement In the spinal cord compression area of degenerative cervical myelopathy, especially in the hyperechoic lesions, intraoperative CEUS showed more significant contrast agent perfusion than in the normal area, and the degree was negatively correlated with the neurological prognosis. Key Points • Recovery rates in patients with hyperechoic findings were lower than those of patients without lesions detected during intraoperative ultrasound. • The peak intensity of CEUS was higher in compressed zones than in the normal parts of the spinal cord. • Quantitative CEUS comparisons of the peak intensity and area under the curve at the compressed and normal levels of the spinal cord revealed differences that were inversely correlated to the recovery rate.