DWDaniel S. Wastl

Daniel S. Wastl

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Daniel S. Wastl has a total of 29 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Amplitude dependence of image quality in atomically-resolved bimodal atomic force microscopy

    by Hiroaki Ooe, Dominik Kirpal, Daniel S. Wastl, Alfred J. Weymouth, Toyoko Arai, Franz J. Giessibl

    In bimodal frequency modulation atomic force microscopy (FM-AFM), two flexural modes are excited simultaneously. We show atomically resolved images of KBr(100) in ambient conditions in both modes that display a strong correlation between the image quality and amplitude. We define the sum amplitude as the sum of the amplitudes of both modes. When the sum amplitude becomes larger than about 100 pm, the signal-to-noise ratio (SNR) drastically decreases. We propose that this is caused by the temporary presence of one or more water layers in the tip-sample gap. These water layers screen the short range interaction and must be displaced with each oscillation cycle. Decreasing the amplitude of either mode, however, increases the noise. Therefore, the highest SNR in ambient conditions is achieved when twice the sum amplitude is slightly less than the thickness of the primary hydration layer.


  • S-layer based biomolecular imprinting

    by Eva M. Ladenhauf, Dietmar Pum, Daniel S. Wastl, Jose Luis Toca-Herrera, Nam V. H. Phan, Peter A. Lieberzeit, Uwe B. Sleytr

    This work describes the development of molecularly imprinted polymer (MIP) thin films by using reassembled S-layer protein arrays as templates. Crystalline bacterial cell surface layer (S-layer) proteins are among the most abundant biopolymers on earth and form the outermost cell envelope component in a broad range of bacteria and archaea. The unique feature of S-layer based imprints is the crystalline character of the reassembled S-layer protein lattice leading to a precisely controllable periodicity of surface functional groups and topographical features. By determining the Young (elastic) modulus of the S-layer protein with respect to that of the polymer at its gel point, the feasibility of the S-layer based biomolecular imprinting was confirmed. After imprinting the polymer with an S-layer coated silicon stamp, the sensitivity of the imprints and their selectivity in relation to various other proteins were investigated by quartz crystal microbalance (QCM) studies. Furtheron, polycationic ferritin (PCF) was bound in a dense packing on the S-layer and subsequently used for stamping. Successful rebinding of PCF proved that the S-layer lattice can be used as a template for making imprints of densely packed and, probably, perfectly oriented biologically functional molecules, a concept that can in principle be extended to a wide range of other biomolecules (e.g. antibodies).


  • Atomic Resolution of Calcium and Oxygen Sublattices of Calcite in Ambient Conditions by Atomic Force Microscopy Using qPlus Sensors with Sapphire Tips

    by Daniel S. Wastl, Michael Judmann, Alfred J. Weymouth, Franz J. Giessibl

    Characterization and imaging at the atomic scale with atomic force microscopy in biocompatible environments is an ongoing challenge. We demonstrate atomically resolved imaging of the calcite (101̅4) surface plane using stiff quartz cantilevers (“qPlus sensors”, stiffness k = 1280 N/m) equipped with sapphire tips in ambient conditions without any surface preparation. With 10 atoms in one surface unit cell, calcite has a highly complex surface structure comprising three different chemical elements (Ca, C, and O). We obtain true atomic resolution of calcite in air at relative humidity ranging from 20% to 40%, imaging atomic steps and single atomic defects. We observe a great durability of sapphire tips with their Mohs hardness of 9, only one step below diamond. Depending on the state of the sapphire tip, we resolve either the calcium or the oxygen sublattice. We determine the tip termination by comparing the experimental images with simulations and discuss the possibility of chemical tip identification in air. The main challenges for imaging arise from the presence of water layers, which form on almost all surfaces and have the potential to dissolve the crystal surface. Frequency shift versus distance spectra show the presence of at least three ordered hydration layers. The measured height of the first hydration layer corresponds well to X-ray diffraction data and molecular dynamic simulations, namely, ∼220 pm. For the following hydration layers we measure ∼380 pm for the second and third layer, ending up in a total hydration layer thickness of at least 1 nm. Understanding the influence of water layers and their structure is important for surface segregation, surface reactions including reconstructions, healing of defects, and corrosion.


  • Oligolayer-Coated Nanoparticles: Impact of Surface Topography at the Nanobio Interface

    by Eva-Christina Wurster, Renate Liebl, Stefanie Michaelis, Rudolf Robelek, Daniel S. Wastl, Franz J. Giessibl, Achim Goepferich, Miriam Breunig

    Layer-by-layer coating of nanoparticles with a layer number in the single-digit range has gained increasing attention in the field of nanomedicinal research. However, the impact of using various polyelectrolytes on oligolayer formation and, more importantly, their influence on the interaction with the biological system has not often been considered in the past. Hence, we investigated the polyelectrolyte deposition profiles and resulting surface topographies of up to three polyelectrolyte layers on a flat gold sensor surface using three different polycations, namely, poly(ethylene imine) (PEI), poly(allylamine hydrochloride) (PAH), and poly(diallylammonium chloride) (PD), each in combination with poly(styrenesulfonate) (PSS). Surface plasmon resonance spectroscopy and atomic force microscopy revealed that the PEI/PSS pair in particular showed a so-called overshoot phenomenon, which is associated with partial polyelectrolyte desorption from the surface. This is also reflected by a significant increase in the surface roughness. Then, after having transferred the oligolayer assembly onto nanoparticles of ∼32 nm, we realized that quite similar surface topographies must have emerged on a curved gold surface. A major finding was that the extent of surface roughness contributes significantly to the fashion by which the oligolayer-coated nanoparticles interact with serum proteins and associate with cells. For example, for the PEI/PSS system, both the surface roughness and protein adsorption increased by a factor of ∼12 from the second to third coating layer and, at the same time, the cell association massively decreased to only one-third. Our study shows that surface roughness, along with other particle properties such as size, shape, zeta potential, and hydrophobicity, is another decisive factor for nanoparticles in a biological context, which has indeed been discussed previously but has not to date been investigated for oligolayers.


  • Influence of matrix and filler fraction on biofilm formation on the surface of experimental resin-based composites

    by Andrei Ionescu, Eugenio Brambilla, Daniel S. Wastl, Franz J. Giessibl, Gloria Cazzaniga, Sibylle Schneider-Feyrer, Sebastian Hahnel

    The aim of this study was to investigate the impact of resin matrix chemistry and filler fraction on biofilm formation on the surface of experimental resin-based composites (RBCs). Specimens were prepared from eight experimental RBC formulations differing in resin matrix blend (BisGMA/TEGDMA in a 7:3 wt% ratio or UDMA/aliphatic dimethacrylate in a 1:1 wt% ratio) and filler fraction (no fillers; 65 wt% dental glass with an average diameter of 7 or 0.7 µm or 65 wt% SiO2 with an average diameter of 20 nm). Surface roughness, surface free energy, and chemical surface composition were determined; surface topography was visualized using atomic force microscopy. Biofilm formation was simulated under continuous flow conditions for a 48 h period using a monospecies Streptococcus mutans and a multispecies biofilm model. In the monospecies biofilm model, the impact of the filler fraction overruled the influence of the resin matrix, indicating lowest biofilm formation on RBCs with nano-scaled filler particles and those manufactured from the neat resin blends. The multispecies model suggested a more pronounced effect of the resin matrix blend, as significantly higher biofilm formation was identified on RBCs with a UDMA/dimethacrylate matrix blend than on those including a BisGMA/TEGDMA matrix blend but analogous filler fractions. Although significant differences in surface properties between the various materials were identified, correlations between the surface properties and biofilm formation were poor, which highlights the relevance of surface topography and chemistry. These results may help to tailor novel RBC formulations which feature reduced biofilm formation on their surface.


  • Atomically Resolved Graphitic Surfaces in Air by Atomic Force Microscopy

    by Daniel S. Wastl, Alfred J. Weymouth, Franz J. Giessibl

    Imaging at the atomic scale using atomic force microscopy in biocompatible environments is an ongoing challenge. We demonstrate atomic resolution of graphite and hydrogen-intercalated graphene on SiC in air. The main challenges arise from the overall surface cleanliness and the water layers which form on almost all surfaces. To further investigate the influence of the water layers, we compare data taken with a hydrophilic bulk-silicon tip to a hydrophobic bulk-sapphire tip. While atomic resolution can be achieved with both tip materials at moderate interaction forces, there are strong differences in force versus distance spectra which relate to the water layers on the tips and samples. Imaging at very low tip–sample interaction forces results in the observation of large terraces of a naturally occurring stripe structure on the hydrogen-intercalated graphene. This structure has been previously reported on graphitic surfaces that are not covered with disordered adsorbates in ambient conditions (i.e., on graphite and bilayer graphene on SiC, but not on monolayer graphene on SiC). Both these observations indicate that hydrogen-intercalated graphene is close to an ideal graphene sample in ambient environments.


  • Streptococcus Mutans Biofilm Formation and Release of Fluoride from Experimental Resin-based Composites Depending on Surface Treatment and S-PRG Filler Particle Fraction

    by Sebastian Hahnel, Daniel S. Wastl, Sibylle Schneider-Feyrer, Franz J. Giessibl, Eugenio Brambilla, Gloria Cazzaniga, Andrei Ionescu

    PURPOSE:\ud To evaluate fluoride release and biofilm formation on resin-based composites (RBCs) including surface pre-reacted glass ionomer (S-PRG) filler particles.\ud MATERIALS AND METHODS:\ud Specimens were prepared from experimental RBCs including different fractions of S-PRG fillers (0/10/30/50/70% w/v). RBCs were light cured against mylar strips (MYL), and 50% of the specimens were additionally polished to a high gloss (POL). Surface roughness (SR), surface free energy (SFE) and fluoride release were determined. Streptococcus mutans biofilm formation (SMBF) was simulated for 48 h and 120 h; adherent viable biomass was assessed using an MTT-based assay.\ud RESULTS:\ud The highest SR was identified for POL specimens manufactured from the RBC with a filler fraction of 70%. For all specimens and surface treatments, polishing caused an increase in surface free energy. For both MYL and POL specimens, increasing the filler fraction coincided with an increased release of fluoride; a higher release of fluoride was identified for POL specimens with filler fractions of 50% and 70% in comparison to their MYL counterparts. Release of fluoride was lower after 120 h than after 48 h. No differences in SMBF were identified between MYL and POL specimens with identical filler fractions after 48 h of biofilm formation; with increasing filler fractions, a tendency towards decreasing SMBF was observed. After 120 h, less SMBF was identified for POL specimens with filler fractions of 30%, 50% and 70% in comparison to corresponding MYL specimens.\ud CONCLUSION:\ud The inclusion of S-PRG fillers and an effective surface treatment may reduce biofilm formation on RBCs


  • Observation of 4 nm Pitch Stripe Domains Formed by Exposing Graphene to Ambient Air

    by Daniel S. Wastl, Florian Speck, Elisabeth Wutscher, Markus Ostler, Thomas Seyller, Franz J. Giessibl

    We study epitaxial graphene on the 6H-SiC(0001) surface under ambient conditions using frequency-modulation atomic force microscopy. We observe large terraces with a self-assembled stripe structure within a highly adsorbate covered surface on top of the graphene. To identify the origin of the structure, we compare the experimental data on graphene with calculations and experiments on graphite that predict the formation of a solid–gas monolayer in the solid–liquid interface of hydrophobic surfaces.


  • Optimizing atomic resolution of force microscopy in ambient conditions

    by Daniel S. Wastl, Alfred J. Weymouth, Franz J. Giessibl

    Ambient operation poses a challenge to atomic force microscopy because in contrast to operation in vacuum or liquid environments, the cantilever dynamics change dramatically from oscillating in air to oscillating in a hydration layer when probing the sample. We demonstrate atomic resolution by imaging of the KBr(001) surface in ambient conditions by frequency-modulation atomic force microscopy with a cantilever based on a quartz tuning fork (qPlus sensor) and analyze both long- and short-range contributions to the damping. The thickness of the hydration layer increases with relative humidity; thus varying humidity enables us to study the influence of the hydration layer thickness on cantilever damping. Starting with measurements of damping versus amplitude, we analyzed the signal and the noise characteristics at the atomic scale. We then determined the optimal amplitude which enabled us to acquire high-quality atomically resolved images.