HNHamid Naghibi

Hamid Naghibi

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Hamid Naghibi has a total of 40 co-authors. Here are the top co-authors by number of shared publications:

  • Nico Verdonschot

    Radboud University Medical Centre, Radboud Institute for Health Sciences, Orthopaedic Research Laboratory, Nijmegen, the Netherlands; University of Twente, Faculty of Engineering Technology, Laboratory for Biomechanical Engineering, Enschede, the Netherlands

    7 shared publications
  • Dennis Janssen

    Orthopaedic Research Laboratory, Department of Orthopaedics Radboud University Medical Center Nijmegen The Netherlands

    4 shared publications
  • Momen Abayazid

    Robotics and Mechatronics, Universiteit Twente, Enschede, Netherlands

    4 shared publications
  • Antonius H. Van Den Boogaard

    University of Twente

    3 shared publications
  • Andre Sprengers

    Orthopaedic Research Lab, Radboud Institute for Health Sciences, Radboud University Medical Center, Nijmegen, The Netherlands

    2 shared publications
  • Dennis Janssen

    Radboud Institute for Health Sciences, Orthopaedic Research Lab, Radboud University Medical Center, Nijmegen, The Netherlands

    2 shared publications

Latest Publications

  • Open Access

    The implications of non-anatomical positioning of a meniscus prosthesis on predicted human knee joint biomechanics

    by Hamid Naghibi, Dennis Janssen, Ton van Den Boogaard, Tony van Tienen, Nico Verdonschot

    Despite all the efforts to optimize the meniscus prosthesis system (geometry, material, and fixation type), the success of the prosthesis in clinical practice will depend on surgical factors such as intra-operative positioning of the prosthesis. In this study, the aim was therefore to assess the implications of positional changes of the medial meniscus prosthesis for knee biomechanics. A detailed validated finite element (FE) model of human intact and meniscal implanted knees was developed based on a series of in vitro experiments. Different non-anatomical prosthesis positions were applied in the FE model, and the biomechanical response during the gait stance phase compared with an anatomically positioned prosthesis, as well as meniscectomized and also the intact knee model. The results showed that an anatomical positioning of the medial meniscus prosthesis could better recover the intact knee biomechanics, while a non-anatomical positioning of the prosthesis to a limited extent alters the knee kinematics and articular contact pressure and increases the implantation failure risk. The outcomes indicate that a medial or anterior positioning of the meniscus prosthesis may be more forgiving than a posteriorly or laterally positioned prosthesis. The outcome of this study may provide a better insight into the possible consequences of meniscus prosthesis positioning errors for the patient and the prosthesis functionality.


  • A novel approach for optimal graft positioning and tensioning in anterior cruciate ligament reconstructive surgery based on the finite element modeling technique

    by Hamid Naghibi, Dennis Janssen, Tony Van Tienen, Sebastiaan Van de Groes, Ton Van de Boogaard, Nico Verdonschot


  • Open Access

    A review on recent advances in soft surgical robots for endoscopic applications

    by M. Wildan Gifari, Hamid Naghibi, Stefano Stramigioli, Momen Abayazid

    Background: Soft materials, with their compliant properties, enable conformity and safe interaction with human body. With the advance in actuation and sensing of soft materials, new paradigm in robotics called “soft robotics” emerges. Soft robotics has become a new approach in designing medical devices such as wearable robotic gloves and exoskeleton. However, application of soft robotics in surgical instrument inside human body is still in its infancy.Aims: In this paper, current application and design of soft robots specifically applied for endoscopy are reviewed.Materials & Methods: Different aspects in the implementation of soft robotics in endoscope design were reviewed. The key studies about MIS and NOTES were reviewed to establish the clinical background and extract the limitations of current endoscopic device in the last decade.Results and discussion: In this review study, the implementation of soft robotics concepts in endoscopic application, with highlights on different features of several soft endoscopes, were evaluated. The progress in different aspects of soft robotics endoscope, current state, and future perspectives were also discussed.Conclusion: Based on the survey on the structural specification, actuation, sensing, and stiffening the future soft surgical endoscopes are recommended to fulfil the following specifications: safe especially from pressure leakage, fully biocompatible materials, MR‐compatible, capable for large bending in at least two antagonistic directions, modularity, adjustable stiffness.


  • Development of a Multi-level Stiffness Soft Robotic Module with Force Haptic Feedback for Endoscopic Applications

    by H. Naghibi, M. W. Gifari, W. Hoitzing, J. W. Lageveen, D.M.M. van As, S. Stramigioli, M. Abayazid

    Despite the recent advances in soft endoscopes, they could not yet fully fulfill the requirements for minimally invasive and natural orifice transluminal endoscopic surgeries. Maneuverability, bendability, different structural stiffness required for different endoscopic surgical interventions, the space needed for surgical manipulators and patient’s safety are amongst the main factors which can contribute to implementing the new soft robotics endoscope in practice. In this study, based on finite element analysis on an existing endoscopic segment, a new improved endoscopic module was developed. A novel approach for stiffening of the endoscopic module was proposed. The actuation and stiffening components were combined to introduce a multi-level stiffening mechanism to the endoscope, and also to provide a free lumen for manipulators. To increase patient’s safety, a force sensing module was developed to estimate the magnitude and direction of the force from tissues to the endoscope. The developed endoscopic system was integrated to a haptic control system. The 3D kinematics control and haptic feedback control of the endoscopic module were validated.


  • A noninvasive MRI based approach to estimate the mechanical properties of human knee ligaments

    by Hamid Naghibi, Valentina Mazzoli, Kaj Gijsbertse, Gerjon Hannink, Andre Sprengers, Dennis Janssen, Ton Van Den Boogaard, Nico Verdonschot


  • Evaluation of design aspects of modular pneumatic soft robotic endoscopes

    by Jan A. Lenssen, Hamid Naghibi, Momen Abayazid

    Minimally Invasive Surgery (MIS) and Natural Orifice Transluminal Endoscopic Surgery (NOTES) are gradually replacing purely open surgery. One of the key components in MIS or NOTES is an endoscope. Soft robotic endoscopes can provide accuracy and safe interaction with human soft tissue. In this study, the design aspects of pneumatic endoscopic soft robots are investigated. These aspects are the radial constraints (sheathing) of pneumatic chambers in the soft robotic module, the number of chambers and the geometric volume of the chambers. The evaluation is considering the influence of these design aspects on the bendability of the soft robot. Besides the module bending performance, other aspects are considered, including; reducing the pneumatic pressure applied for bending, minimizing the module dimensions, and using the design in multi-module configuration in endoscopic applications. These design aspects are evaluated using finite element models that are validated experimentally based on tests performed in this study and previous studies. The results show that despite the fact that the 4-chamber module provides higher moment arm while bending, using three chambers is more optimal for control and pneumatic hardware requirements. It was observed that outer sheathing provides more bending at lower pneumatic pressure. Moreover, the cylindrical chamber design provides higher bending capabilities, but other volumetric designs can be considered in case more space is needed for miniaturizing the design. In conclusion, the results in this study provide new insight in the design aspects of the pneumatic chambers of soft robotic endoscopes which is beneficial for bringing conceptual designs into clinical practice.


  • A Flexible Endoscopic Sensing Module for Force Haptic Feedback Integration

    by Hamid Naghibi, Willem B. Hoitzing, Stefano Stramigioli, Momen Abayazid

    Proper haptic feedback is a key aspect to the safety of a teleoperated endoscopic surgical robotics system. In this study we developed a flexible sensing module to measure the directional force, and a haptic control of a soft robotic endoscopic segment. The force amplitude and direction detection was based on the voltage changes in four strain gauges positioned at four quarters of a flexible cylinder. The flexible structure of the cylinder allowed for large deformation which can reduce the risk of tissue damage at interfaces. Inverse finite element analysis and finite element simulations were implemented to further improve and verify the developed system. The system including the haptic feedback controller could enhance operator navigation.


  • A Soft Robotic Phantom to Simulate the Dynamic Respiratory Motion of Human Liver

    by Hamid Naghibi, Paulo A. C. Costa, Momen Abayazid

    In percutaneous interventions for hepatic tumor treatment, organ motion caused by respiration can lead to inaccurate needle placement hence less effective therapeutic and diagnostic outcome. The aim of this study was to implement soft robotics technology to develop an actuated phantom that mimics respiratory motion in liver for needle insertion procedures. The actuated liver phantom should be MR-compatible as it will be used for testing needle insertion devices and prototypes in an MRI environment while considering the respiratory motion of the liver. The soft-actuated robotic phantom can also be used for training clinicians on MRI-guided percutaneous needle interventions such as manual biopsy and ablation. Pneumatic soft actuators were design and implemented in the phantom to achieve a smooth motion similar to liver respiratory motion. In order to evaluate the performance of the phantom, three common breathing types were simulated, as well as a normal and two abnormal breathing patterns in patients. Moreover, a normal respiration was simulated with different phantom weights to be representative for different liver masses. The results revealed that the developed robotic simulator is sensitive to feeding air pressure and actuating time period, and to a less extend to the phantom mass. Based on five cycle repetitions, the simulator could reproduce different respirations with a maximal deviation of 3mm in superior, 2mm in inferior and less than 1mm in anterior-posterior directions.


  • Open Access

    Strain imaging of the lateral collateral ligament using high frequency and conventional ultrasound imaging: An ex-vivo comparison

    by Kaj Gijsbertse, André Sprengers, Hamid Naghibi Beidokhti, Maartje Nillesen, Chris de Korte, Nico Verdonschot


  • Open Access

    The peripheral soft tissues should not be ignored in the finite element models of the human knee joint

    by Hamid Naghibi Beidokhti, Dennis Janssen, Sebastiaan van de Groes, Nico Verdonschot

    In finite element models of the either implanted or intact human knee joint, soft tissue structures like tendons and ligaments are being incorporated, but usually skin, peripheral knee soft tissues, and the posterior capsule are ignored and assumed to be of minor influence on knee joint biomechanics. It is, however, unknown how these peripheral structures influence the biomechanical response of the knee. In this study, the aim was to assess the significance of the peripheral soft tissues and posterior capsule on the kinematics and laxities of human knee joint, based on experimental tests on three human cadaveric specimens. Despite the high inter-subject variability of the results, it was demonstrated that the target tissues have a considerable influence on posterior translational and internal and valgus rotational laxities of lax knees under flexion. Consequently, ignoring these tissues from computational models may alter the knee joint biomechanics.