Hassan Bayat
Research Subjects
Hassan Bayat has a total of 27 co-authors. Here are the top co-authors by number of shared publications:
- James O. Westgard
Department of Pathology and Laboratory Medicine, School of Medicine and Public Health, University of Wisconsin, Madison, WI 53705, USA; Westgard QC, Inc, Madison, WI 53717, USA
3 shared publications Sten A. Westgard
Westgard QC, Inc. , Madison WI , USA
3 shared publicationsSten Westgard
Westgard QC
2 shared publicationsSverre Sandberg
Consultant, The Norwegian Organization for Quality Improvement of Laboratory Examinations (NOKLUS) , Bergen
2 shared publications- Abdurrahman Coskun
Department of Medicine Knappschaft Kliniken University Hospital Bochum, Ruhr‐University Bochum Bochum Germany
1 shared publication Anders Kallner
Department of Clinical Chemistry , Karolinska University Hospital Stockholm , Stockholm , Sweden
1 shared publication
Latest Publications
- 14 October 2026
- Published by Oxford University Press (OUP) in Clinical Chemistry
What Should Internal Quality Control Look Like in 2030?
- 14 October 2026
- Published by Oxford University Press (OUP) in Clinical Chemistry
What Should Internal Quality Control Look Like in 2030?
- 12 June 2024
- Published by Walter de Gruyter GmbH in Clinical Chemistry and Laboratory Medicine (CCLM)
- Vol. 62 (12) , 2401-2404
The value of Sigma-metrics in laboratory medicine
While Six Sigma is used in different disciplines to improve quality, Tony Badric and Elvar Theodorsson in a recent paper in CCLM have questioned Six Sigma application in medical laboratory concluding Six Sigma has provided no value to medical laboratory. In addition, the authors have expanded their criticism to Total Analytical Error (TAE) model and statistical quality control. To address their arguments, we have explained the basics of TAE model and Six Sigma and have shown the value of Six Sigma to medical laboratory.
- 12 June 2024
- Published by Walter de Gruyter GmbH in Clinical Chemistry and Laboratory Medicine (CCLM)
- Vol. 62 (12) , 2401-2404
The value of Sigma-metrics in laboratory medicine
While Six Sigma is used in different disciplines to improve quality, Tony Badric and Elvar Theodorsson in a recent paper in CCLM have questioned Six Sigma application in medical laboratory concluding Six Sigma has provided no value to medical laboratory. In addition, the authors have expanded their criticism to Total Analytical Error (TAE) model and statistical quality control. To address their arguments, we have explained the basics of TAE model and Six Sigma and have shown the value of Six Sigma to medical laboratory.
- 1 June 2023
- Published by Walter de Gruyter GmbH in Clinical Chemistry and Laboratory Medicine (CCLM)
- Vol. 61 (11) , e215-e217
Limitations in using the EFLM WG-A/ISO approach for assessment of reagent lot variability
Article Limitations in using the EFLM WG-A/ISO approach for assessment of reagent lot variability was published on June 1, 2023 in the journal Clinical Chemistry and Laboratory Medicine (CCLM) (volume 0, issue 0).
- 1 June 2023
- Published by Walter de Gruyter GmbH in Clinical Chemistry and Laboratory Medicine (CCLM)
- Vol. 61 (11) , e215-e217
Limitations in using the EFLM WG-A/ISO approach for assessment of reagent lot variability
Article Limitations in using the EFLM WG-A/ISO approach for assessment of reagent lot variability was published on June 1, 2023 in the journal Clinical Chemistry and Laboratory Medicine (CCLM) (volume 0, issue 0).
- 14 June 2022
- Published by Walter de Gruyter GmbH in Clinical Chemistry and Laboratory Medicine (CCLM)
- Vol. 60 (9) , e199-e201
How to evaluate fixed clinical QC limits vs. risk-based SQC strategies
Article How to evaluate fixed clinical QC limits vs. risk-based SQC strategies was published on June 14, 2022 in the journal Clinical Chemistry and Laboratory Medicine (CCLM) (volume 0, issue 0).
- 14 June 2022
- Published by Walter de Gruyter GmbH in Clinical Chemistry and Laboratory Medicine (CCLM)
- Vol. 60 (9) , e199-e201
How to evaluate fixed clinical QC limits vs. risk-based SQC strategies
Article How to evaluate fixed clinical QC limits vs. risk-based SQC strategies was published on June 14, 2022 in the journal Clinical Chemistry and Laboratory Medicine (CCLM) (volume 0, issue 0).
- 6 January 2022
- Published by Elsevier in Clinical Biochemistry
- Vol. 102, 50-55
Multirule procedures vs moving average algorithms for IQC: An appropriate comparison reveals how best to combine their strengths
- 6 January 2022
- Published by Elsevier in Clinical Biochemistry
- Vol. 102, 50-55
Multirule procedures vs moving average algorithms for IQC: An appropriate comparison reveals how best to combine their strengths
- 1 December 2021
- Published by Elsevier in Clinica Chimica Acta
- Vol. 523, 216-223
A multi-test planning model for risk based statistical quality control strategies
- 1 December 2021
- Published by Elsevier in Clinica Chimica Acta
- Vol. 523, 216-223
A multi-test planning model for risk based statistical quality control strategies
- Open Access
- 15 December 2018
- Published by Croatian Society for Medical Biochemistry and Laboratory Medicine in Biochemia Medica
- Vol. 29 (1) , 010903
Mistaken assumptions drive new Six Sigma model off the road
Mistaken assumptions drive new Six Sigma model off the road
- 15 December 2018
- Published by Croatian Society for Medical Biochemistry and Laboratory Medicine in Biochemia Medica
- Vol. 29 (1) , 010903
Open AccessMistaken assumptions drive new Six Sigma model off the road
Mistaken assumptions drive new Six Sigma model off the road
- Open Access
- 15 June 2018
- Published by Croatian Society for Medical Biochemistry and Laboratory Medicine in Biochemia Medica
- Vol. 28 (2) , 020101
Expected long-term defect rate of analytical performance in the medical laboratory: Assured Sigma versus observed Sigma
Reliability of laboratory results is determined by the ratio of incorrect results expected in long-term. Sigma is a measure of defect ratio, therefore long-term Sigma is a measure of the reliability of laboratory results. Commonly, long-term Sigma is estimated based on the short-term Sigma. The Six Sigma methodology assumes that in long-term performances will shift up to 1.5 Sigma, and therefore the long-term Sigma is considered 1.5 Sigma less than short-term Sigma. Analytical performance in the medical laboratory is prone to shifts larger than 1.5 Sigma. Thus, the 1.5 Sigma shift assumed in the Six Sigma is not a correct estimate in the medical laboratory. On the other hand, in the medical laboratory statistical quality control procedure (SQC) is applied to detect and correct shifts. Since SQC can be planned to trap shifts of different sizes, the threshold set for SQC determines the defect rate expected for long-term.
- 15 June 2018
- Published by Croatian Society for Medical Biochemistry and Laboratory Medicine in Biochemia Medica
- Vol. 28 (2) , 020101
Open AccessExpected long-term defect rate of analytical performance in the medical laboratory: Assured Sigma versus observed Sigma
Reliability of laboratory results is determined by the ratio of incorrect results expected in long-term. Sigma is a measure of defect ratio, therefore long-term Sigma is a measure of the reliability of laboratory results. Commonly, long-term Sigma is estimated based on the short-term Sigma. The Six Sigma methodology assumes that in long-term performances will shift up to 1.5 Sigma, and therefore the long-term Sigma is considered 1.5 Sigma less than short-term Sigma. Analytical performance in the medical laboratory is prone to shifts larger than 1.5 Sigma. Thus, the 1.5 Sigma shift assumed in the Six Sigma is not a correct estimate in the medical laboratory. On the other hand, in the medical laboratory statistical quality control procedure (SQC) is applied to detect and correct shifts. Since SQC can be planned to trap shifts of different sizes, the threshold set for SQC determines the defect rate expected for long-term.
- 10 August 2017
- Published by Walter de Gruyter GmbH in Clinical Chemistry and Laboratory Medicine (CCLM)
- Vol. 56 (2) , 209-219
The use of error and uncertainty methods in the medical laboratory
Error methods – compared with uncertainty methods – offer simpler, more intuitive and practical procedures for calculating measurement uncertainty and conducting quality assurance in laboratory medicine. However, uncertainty methods are preferred in other fields of science as reflected by the guide to the expression of uncertainty in measurement. When laboratory results are used for supporting medical diagnoses, the total uncertainty consists only partially of analytical variation. Biological variation, pre- and postanalytical variation all need to be included. Furthermore, all components of the measuring procedure need to be taken into account. Performance specifications for diagnostic tests should include the diagnostic uncertainty of the entire testing process. Uncertainty methods may be particularly useful for this purpose but have yet to show their strength in laboratory medicine. The purpose of this paper is to elucidate the pros and cons of error and uncertainty methods as groundwork for future consensus on their use in practical performance specifications. Error and uncertainty methods are complementary when evaluating measurement data.
- 10 August 2017
- Published by Walter de Gruyter GmbH in Clinical Chemistry and Laboratory Medicine (CCLM)
- Vol. 56 (2) , 209-219
The use of error and uncertainty methods in the medical laboratory
Error methods – compared with uncertainty methods – offer simpler, more intuitive and practical procedures for calculating measurement uncertainty and conducting quality assurance in laboratory medicine. However, uncertainty methods are preferred in other fields of science as reflected by the guide to the expression of uncertainty in measurement. When laboratory results are used for supporting medical diagnoses, the total uncertainty consists only partially of analytical variation. Biological variation, pre- and postanalytical variation all need to be included. Furthermore, all components of the measuring procedure need to be taken into account. Performance specifications for diagnostic tests should include the diagnostic uncertainty of the entire testing process. Uncertainty methods may be particularly useful for this purpose but have yet to show their strength in laboratory medicine. The purpose of this paper is to elucidate the pros and cons of error and uncertainty methods as groundwork for future consensus on their use in practical performance specifications. Error and uncertainty methods are complementary when evaluating measurement data.
- 1 January 2017
- Published by Walter de Gruyter GmbH in Clinical Chemistry and Laboratory Medicine (CCLM)
- Vol. 55 (11) , 1702-1708
Selecting multi-rule quality control procedures based on patient risk
Background: Traditionally, statistical quality control (SQC) planning is aimed at preventing the error rate from exceeding a pre-defined acceptable rate (Westgard JO. Basic QC Practices, 4th ed. Westgard QC, 2016). A pivotal characteristic for planning a QC procedure with the traditional approach is the probability of rejecting an analytical run that contains critical size errors (PMethods: We used a statistical model to investigate the relationship between PResults: There is a close relationship between PConclusions: Multi-rule SQC procedures can be used for controlling intermediate and low sigma capability method to attain a low Max E(N
- 1 January 2017
- Published by Walter de Gruyter GmbH in Clinical Chemistry and Laboratory Medicine (CCLM)
- Vol. 55 (11) , 1702-1708
Selecting multi-rule quality control procedures based on patient risk
Background: Traditionally, statistical quality control (SQC) planning is aimed at preventing the error rate from exceeding a pre-defined acceptable rate (Westgard JO. Basic QC Practices, 4th ed. Westgard QC, 2016). A pivotal characteristic for planning a QC procedure with the traditional approach is the probability of rejecting an analytical run that contains critical size errors (PMethods: We used a statistical model to investigate the relationship between PResults: There is a close relationship between PConclusions: Multi-rule SQC procedures can be used for controlling intermediate and low sigma capability method to attain a low Max E(N