Laurence Guédon-Moreau
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Laurence Guédon-Moreau has a total of 173 co-authors. Here are the top co-authors by number of shared publications:
Salem Kacet
Department of Cardiovascular Medicine, Lille University Hospital, 59370 Lille, France; Faculty of Medicine, University of Lille 2, 59000 Lille, France
17 shared publicationsClaude Kouakam
CHU Lille , Lille , France
16 shared publicationsDominique Lacroix
Department of cardiovascular medicine, heart & lung institute, Lille university hospital, 59037 Lille, France; Faculty of medicine, Lille university, 59045 Lille, France
16 shared publicationsChristelle Marquié
Department of cardiovascular medicine, heart & lung institute, Lille university hospital, 59037 Lille, France
13 shared publicationsDidier Klug
Department of Cardiovascular Medicine, Lille University Hospital, 59370 Lille, France; Faculty of Medicine, University of Lille 2, 59000 Lille, France
12 shared publicationsFrançois Brigadeau
Department of cardiovascular medicine, heart & lung institute, Lille university hospital, 59037 Lille, France
12 shared publications
Latest Publications
- Open Access
- 3 October 2024
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 26 (10)
Comprehensive vs. standard remote monitoring of cardiac resynchronization devices in heart failure patients: results of the ECOST-CRT study
Integrating remote monitoring (RM) into existing healthcare practice for heart failure (HF) patients to improve clinical outcome remains challenging. The ECOST-CRT study compared the clinical outcome of a comprehensive RM scheme including a patient questionnaire capturing signs and symptoms of HF and notifications for HF specific parameters to traditional RM in patients with cardiac resynchronization therapy (CRT) devices. Patients were randomized 1:1 to standard daily RM (notification for technical parameters and ventricular arrhythmias; control group) or comprehensive RM (adding a monthly symptom questionnaire and notifications for biventricular pacing, premature ventricular contraction, atrial arrhythmias; active group). The primary endpoint was all-cause mortality or hospitalization for worsening HF (WHF). Six hundred fifty-two patients (70.4 ± 10.3 years, 73% men, left ventricular ejection fraction 29.1 ± 7.6%, 68% CRT-Defibrillators, 32% CRT-Pacemakers) were enrolled. The COVID-19 pandemic caused an early termination of the study, so the mean follow-up duration was 18 ± 8 months. No statistically significant difference in the primary endpoint was found between the groups [59 (18.3%) control vs. 77 (23.3%) active group; log-rank test P = 0.13]. Among the secondary endpoints, the MLHF questionnaire showed a larger share of patients with improvement of quality of life compared to baseline in the active group (78%) vs. control (61%; P = 0.03). The study does not support the notion that comprehensive RM, when compared to standard RM, in HF patients with CRT improves the clinical outcome of all-cause mortality or WHF hospitalizations. However, this study was underpowered due to an early termination and further trials are required. Clinical Trials.gov Identifier: NCT03012490 CRT, cardiac resynchronization therapy; HF, heart failure; PVC, premature ventricular contraction; RM, remote monitoring; WHF, worsening heart failure.
- 3 October 2024
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 26 (10)
Open AccessComprehensive vs. standard remote monitoring of cardiac resynchronization devices in heart failure patients: results of the ECOST-CRT study
Integrating remote monitoring (RM) into existing healthcare practice for heart failure (HF) patients to improve clinical outcome remains challenging. The ECOST-CRT study compared the clinical outcome of a comprehensive RM scheme including a patient questionnaire capturing signs and symptoms of HF and notifications for HF specific parameters to traditional RM in patients with cardiac resynchronization therapy (CRT) devices. Patients were randomized 1:1 to standard daily RM (notification for technical parameters and ventricular arrhythmias; control group) or comprehensive RM (adding a monthly symptom questionnaire and notifications for biventricular pacing, premature ventricular contraction, atrial arrhythmias; active group). The primary endpoint was all-cause mortality or hospitalization for worsening HF (WHF). Six hundred fifty-two patients (70.4 ± 10.3 years, 73% men, left ventricular ejection fraction 29.1 ± 7.6%, 68% CRT-Defibrillators, 32% CRT-Pacemakers) were enrolled. The COVID-19 pandemic caused an early termination of the study, so the mean follow-up duration was 18 ± 8 months. No statistically significant difference in the primary endpoint was found between the groups [59 (18.3%) control vs. 77 (23.3%) active group; log-rank test P = 0.13]. Among the secondary endpoints, the MLHF questionnaire showed a larger share of patients with improvement of quality of life compared to baseline in the active group (78%) vs. control (61%; P = 0.03). The study does not support the notion that comprehensive RM, when compared to standard RM, in HF patients with CRT improves the clinical outcome of all-cause mortality or WHF hospitalizations. However, this study was underpowered due to an early termination and further trials are required. Clinical Trials.gov Identifier: NCT03012490 CRT, cardiac resynchronization therapy; HF, heart failure; PVC, premature ventricular contraction; RM, remote monitoring; WHF, worsening heart failure.
- Open Access
- 31 August 2023
- Published by MDPI AG in Healthcare
- Vol. 11 (17) , 2447
Activities of Clinical Expertise and Research in a Rare Disease Referral Centre: A Place for Telemedicine beyond the COVID-19 Pandemic?
Introduction: Rare disease referral centres are entrusted with missions of clinical expertise and research, two activities that have to contend with numerous obstacles. Providing specialist opinions is time-consuming, uncompensated and limited by difficulties in exchanging medical data. Clinical research is constrained by the need for frequent research protocol visits. Our objective was to determine whether telemedicine (TLM) can overcome these difficulties. Methods: To better characterise the activity of clinical expertise provided by our French centre, each opinion delivered by our team was reported on a standardised form. To investigate our clinical research activity, investigators and patients were asked to complete a questionnaire on the acceptability of research protocol teleconsultations. Results: Regarding clinical expertise, our team delivered 120 opinions per week (representing a total of 21 h), of which 29% were delivered to patients and 69% to medical practitioners. If these were delivered using TLM, it would represent a potential weekly income of EUR 500 (tele-expertise) and EUR 775 (teleconsultations). Regarding the research activity, 70% of investigators considered the frequency of visits to be a limiting factor for patient inclusions; nearly half of the patients surveyed would be in favour of having teleconsultations in place of (40%) or in addition to (56%) in-person visits. Conclusion: Whereas TLM has become widely used as a back-up procedure to in-person consultations during the COVID-19 pandemic, the solutions it provides to the problems encountered in performing expertise and research activities have made it a new conventional follow-up modality for patients with rare diseases.
- 31 August 2023
- Published by MDPI AG in Healthcare
- Vol. 11 (17) , 2447
Open AccessActivities of Clinical Expertise and Research in a Rare Disease Referral Centre: A Place for Telemedicine beyond the COVID-19 Pandemic?
Introduction: Rare disease referral centres are entrusted with missions of clinical expertise and research, two activities that have to contend with numerous obstacles. Providing specialist opinions is time-consuming, uncompensated and limited by difficulties in exchanging medical data. Clinical research is constrained by the need for frequent research protocol visits. Our objective was to determine whether telemedicine (TLM) can overcome these difficulties. Methods: To better characterise the activity of clinical expertise provided by our French centre, each opinion delivered by our team was reported on a standardised form. To investigate our clinical research activity, investigators and patients were asked to complete a questionnaire on the acceptability of research protocol teleconsultations. Results: Regarding clinical expertise, our team delivered 120 opinions per week (representing a total of 21 h), of which 29% were delivered to patients and 69% to medical practitioners. If these were delivered using TLM, it would represent a potential weekly income of EUR 500 (tele-expertise) and EUR 775 (teleconsultations). Regarding the research activity, 70% of investigators considered the frequency of visits to be a limiting factor for patient inclusions; nearly half of the patients surveyed would be in favour of having teleconsultations in place of (40%) or in addition to (56%) in-person visits. Conclusion: Whereas TLM has become widely used as a back-up procedure to in-person consultations during the COVID-19 pandemic, the solutions it provides to the problems encountered in performing expertise and research activities have made it a new conventional follow-up modality for patients with rare diseases.
- 11 February 2023
- Published by Elsevier in Archives des Maladies du Coeur et des Vaisseaux - Pratique
- Vol. 2023 (316) , 3-7
Télésurveillance en rythmologie : apports et limites
- 11 February 2023
- Published by Elsevier in Archives des Maladies du Coeur et des Vaisseaux - Pratique
- Vol. 2023 (316) , 3-7
Télésurveillance en rythmologie : apports et limites
- 26 May 2022
- Published by Elsevier in Archives of Cardiovascular Diseases
- Vol. 115 (6-7) , 406-407
Remote monitoring for cardiac implantable electronic devices: A practical guide
- 26 May 2022
- Published by Elsevier in Archives of Cardiovascular Diseases
- Vol. 115 (6-7) , 406-407
Remote monitoring for cardiac implantable electronic devices: A practical guide
- 1 April 2021
- Published by Elsevier in Archives of Cardiovascular Diseases
- Vol. 114 (4) , 287-292
Usefulness of remote monitoring for the early detection of back-up mode in implantable cardioverter defibrillators
- 1 April 2021
- Published by Elsevier in Archives of Cardiovascular Diseases
- Vol. 114 (4) , 287-292
Usefulness of remote monitoring for the early detection of back-up mode in implantable cardioverter defibrillators
- 24 February 2021
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 32 (5) , 1376-1384
Evolution of high‐grade atrioventricular conduction disorders after transcatheter aortic valve implantation in patients who underwent implantation of a pacemaker with specific mode—that minimizes ventricular pacing—activated
Introduction: The evolution of atrioventricular conduction disorders after transcatheter aortic valve implantation (TAVI) remains poorly understood. We sought to identify factors associated with late (occurring ≥7 days after the procedure) high‐grade atrioventricular blocks after TAVI, based on specific pacemaker memory data.Methods and Results: STIM‐TAVI (NCT03338582) was a prospective, multicentre, observational study that enrolled all patients (from November 2015 to January 2017) implanted with a specific dual chamber pacemaker after TAVI, with the SafeR algorithm activated, allowing continuous monitoring of atrioventricular conduction. The primary endpoint was the occurrence of centrally adjudicated late high‐grade atrioventricular blocks during the year after TAVI. Among 197 patients, 138 (70.1%) had ≥1 late high‐grade atrioventricular block. Whereas oversizing (p = .005), high‐grade atrioventricular block during TAVI (p < .001), and early (within 6 days) high‐grade atrioventricular block (p < .001) were associated with occurrence of late high‐grade atrioventricular block, self‐expanding prothesis (p = .88), prior right bundle branch block (p = .45), low implantation (p = .06), and new or wider left bundle branch block and lengthening of PR interval (p = .24) were not. In multivariable analysis, only post‐TAVI early high‐grade atrioventricular block remained associated with late high‐grade atrioventricular blocks (Days 0–1: odds ratio [OR], 3.25; 95% confidence interval [CI], 1.57–6.74; p = .001; Days 2–6: OR, 4.13; 95% CI, 2.06–8.31; p < .001), whereas other conventionally used predictors were not.Conclusion: One‐third of pacemaker‐implanted patients do not experience late high‐grade atrioventricular block. Our findings suggest that post‐TAVI early high‐grade atrioventricular block is the main factor associated with occurrence of late high‐grade atrioventricular blocks.
- 24 February 2021
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 32 (5) , 1376-1384
Evolution of high‐grade atrioventricular conduction disorders after transcatheter aortic valve implantation in patients who underwent implantation of a pacemaker with specific mode—that minimizes ventricular pacing—activated
Introduction: The evolution of atrioventricular conduction disorders after transcatheter aortic valve implantation (TAVI) remains poorly understood. We sought to identify factors associated with late (occurring ≥7 days after the procedure) high‐grade atrioventricular blocks after TAVI, based on specific pacemaker memory data.Methods and Results: STIM‐TAVI (NCT03338582) was a prospective, multicentre, observational study that enrolled all patients (from November 2015 to January 2017) implanted with a specific dual chamber pacemaker after TAVI, with the SafeR algorithm activated, allowing continuous monitoring of atrioventricular conduction. The primary endpoint was the occurrence of centrally adjudicated late high‐grade atrioventricular blocks during the year after TAVI. Among 197 patients, 138 (70.1%) had ≥1 late high‐grade atrioventricular block. Whereas oversizing (p = .005), high‐grade atrioventricular block during TAVI (p < .001), and early (within 6 days) high‐grade atrioventricular block (p < .001) were associated with occurrence of late high‐grade atrioventricular block, self‐expanding prothesis (p = .88), prior right bundle branch block (p = .45), low implantation (p = .06), and new or wider left bundle branch block and lengthening of PR interval (p = .24) were not. In multivariable analysis, only post‐TAVI early high‐grade atrioventricular block remained associated with late high‐grade atrioventricular blocks (Days 0–1: odds ratio [OR], 3.25; 95% confidence interval [CI], 1.57–6.74; p = .001; Days 2–6: OR, 4.13; 95% CI, 2.06–8.31; p < .001), whereas other conventionally used predictors were not.Conclusion: One‐third of pacemaker‐implanted patients do not experience late high‐grade atrioventricular block. Our findings suggest that post‐TAVI early high‐grade atrioventricular block is the main factor associated with occurrence of late high‐grade atrioventricular blocks.
- 1 October 2016
- Published by Elsevier in Archives of Cardiovascular Diseases
- Vol. 109 (10) , 517-526
Long-term outcome of implantable cardioverter–defibrillator implantation in secondary prevention of sudden cardiac death
- 1 October 2016
- Published by Elsevier in Archives of Cardiovascular Diseases
- Vol. 109 (10) , 517-526
Long-term outcome of implantable cardioverter–defibrillator implantation in secondary prevention of sudden cardiac death
- 1 March 2016
- Published by Elsevier in European Research in Telemedicine / La Recherche Européenne en Télémédecine
- Vol. 5 (1) , 9-17
Méthodes de détection des troubles du rythme supraventriculaire par télésurveillance des défibrillateurs automatiques implantables et analyse de 2620 alertes monocentriques
- 1 March 2016
- Published by Elsevier in European Research in Telemedicine / La Recherche Européenne en Télémédecine
- Vol. 5 (1) , 9-17
Méthodes de détection des troubles du rythme supraventriculaire par télésurveillance des défibrillateurs automatiques implantables et analyse de 2620 alertes monocentriques
- 28 December 2015
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 18 (12) , euv392-1817
Potential role of antitachycardia pacing alerts for the reduction of emergency presentations following shocks in patients with implantable cardioverter-defibrillators: implications for the implementation of remote monitoring
Despite increased use of remote monitoring (RM) to follow up implantable cardioverter-defibrillator (ICD) recipients, many patients still receive ICD shocks in the community and present to the emergency department. Our aim was to identify the best predictors of impending shock delivery that can be measured with an ICD and to identify the most appropriate activities to alert physicians to during RM follow-up. All patients presenting to our institution for ICD shock, from November 2011 to November 2014, were enrolled in this prospective study. Patient characteristics, investigation results, and details of electrical activities from ICD interrogation were recorded at presentation. Presentations were classified as potentially avoidable if activities from a list of set criteria were apparent more than 48 h before index shock. Univariate and multivariate analyses were then used to identify predictors of potentially avoidable shocks. In total, 109 emergency presentations were recorded in 90 patients (male: 85%; 57 ± 16 years; ischaemic cardiomyopathy: 49%; LVEF: 34 ± 13%; electrical storm: 40%), of which 26 (24%) were potentially avoidable. Antitachycardia pacing (ATP) episodes were the most important predictor of impending shock. Potentially avoidable shocks were preceded by more episodes of ATP than unavoidable shocks (13 [3-67] vs. 3 [0-10]; P < 0.001). Patients followed up with RM systems configured to generate alerts following ATP delivery experienced significantly less ICD shocks (24 vs. 16%, P < 0.01). Remote monitoring systems that generate alerts following ATP delivery could reduce emergency presentations for ICD shock by 24%, as ATP is a key predictor of impending shock delivery.
- 28 December 2015
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 18 (12) , euv392-1817
Potential role of antitachycardia pacing alerts for the reduction of emergency presentations following shocks in patients with implantable cardioverter-defibrillators: implications for the implementation of remote monitoring
Despite increased use of remote monitoring (RM) to follow up implantable cardioverter-defibrillator (ICD) recipients, many patients still receive ICD shocks in the community and present to the emergency department. Our aim was to identify the best predictors of impending shock delivery that can be measured with an ICD and to identify the most appropriate activities to alert physicians to during RM follow-up. All patients presenting to our institution for ICD shock, from November 2011 to November 2014, were enrolled in this prospective study. Patient characteristics, investigation results, and details of electrical activities from ICD interrogation were recorded at presentation. Presentations were classified as potentially avoidable if activities from a list of set criteria were apparent more than 48 h before index shock. Univariate and multivariate analyses were then used to identify predictors of potentially avoidable shocks. In total, 109 emergency presentations were recorded in 90 patients (male: 85%; 57 ± 16 years; ischaemic cardiomyopathy: 49%; LVEF: 34 ± 13%; electrical storm: 40%), of which 26 (24%) were potentially avoidable. Antitachycardia pacing (ATP) episodes were the most important predictor of impending shock. Potentially avoidable shocks were preceded by more episodes of ATP than unavoidable shocks (13 [3-67] vs. 3 [0-10]; P < 0.001). Patients followed up with RM systems configured to generate alerts following ATP delivery experienced significantly less ICD shocks (24 vs. 16%, P < 0.01). Remote monitoring systems that generate alerts following ATP delivery could reduce emergency presentations for ICD shock by 24%, as ATP is a key predictor of impending shock delivery.