Corey Scholes
Research Subjects
Research Interests
Corey Scholes has a total of 201 co-authors. Here are the top co-authors by number of shared publications:
David A. Parker
Sydney Orthopaedic Research Institute, NSW, Australia
13 shared publicationsMilad Ebrahimi
EBM Analytics
9 shared publicationsManaal Fatima
EBM Analytics, Sydney, New South Wales
8 shared publicationsNalan Ektas
<!--1--> EBM Analytics Crows Nest NSW Australia
8 shared publications- Christopher Bell
<!--2--> Orthopaedics Department Queen Elizabeth II Jubilee Hospital Coopers Plains QLD Australia
7 shared publications - David A. Parker
Sydney Orthopaedic Research Institute
7 shared publications
Latest Publications
- Open Access
- 6 July 2026
- Published by Springer Nature in European Journal of Orthopaedic Surgery & Traumatology
- Vol. 36 (1) , 276
Robotic-assisted total knee arthroplasty does not increase procedure duration or adverse event incidence: a retrospective comparative cohort study in a secondary public hospital
Background: Total knee arthroplasty (TKA) with various guidance methods for bone cuts and soft-tissue balancing yields excellent outcomes for end-stage knee osteoarthritis, offering durable pain relief and functional restoration. However, there is a growing interest in further enhancing intraoperative accuracy and consistency, with the aim of reducing complications and reducing recovery times through the introduction of robotic-assisted surgery (RAS). As with any new technology, concerns remain regarding the surgeon learning curve, operative efficiency, and safety profile of RAS compared to conventional techniques. This study evaluates the clinical utility of a RAS system (ROSA, Zimmer Biomet) in a public hospital setting, assessing its impact on procedure duration and adverse event incidence at 90 days postoperatively. Methods: A retrospective comparative cohort study was conducted at a secondary public hospital (Queen Elizabeth II Jubilee Hospital) in, Brisbane, Australia. Data was extracted from a departmental registry, electronic medical records, and intraoperative reports from September 2017 to February 2023. The study included 568 TKA cases: 173 instrumented or navigated TKAs performed before RAS introduction (Pre-RAS), 258 robotic-assisted TKAs after RAS adoption (RAS group), and 137 TKAs performed by other department surgeons who did not use RAS (non-RAS), serving as a benchmark for department-wide outcomes. The primary outcomes were procedure duration and adverse event incidence including surgical site infection (SSI), venous thromboembolism (VTE), knee stiffness, and all-cause readmission within 90 days postoperatively. Results: Among 67 recorded adverse events, no significant differences in total adverse event incidence were observed between the pre-RAS and RAS groups (12.1% vs. 11.6%, p = 0.78). A non-significant increase in superficial infections in males undergoing RAS-TKA was observed ( p = 0.062). The pre-RAS group had significantly longer operative times than the RAS group (128 ± 21.6 min vs. 121.4 ± 19.5 min, p < 0.01). The non-RAS department group had shorter procedure durations than the pre-RAS group (118.3 ± 20.1 min, p < 0.01). Conclusion: RAS-TKA was associated with shorter operative times and a comparable safety profile to non-robotic TKA in this cohort. Further investigation is warranted to determine whether these findings are maintained across different settings and over longer follow-up periods.
- 6 July 2026
- Published by Springer Nature in European Journal of Orthopaedic Surgery & Traumatology
- Vol. 36 (1) , 276
Open AccessRobotic-assisted total knee arthroplasty does not increase procedure duration or adverse event incidence: a retrospective comparative cohort study in a secondary public hospital
Background: Total knee arthroplasty (TKA) with various guidance methods for bone cuts and soft-tissue balancing yields excellent outcomes for end-stage knee osteoarthritis, offering durable pain relief and functional restoration. However, there is a growing interest in further enhancing intraoperative accuracy and consistency, with the aim of reducing complications and reducing recovery times through the introduction of robotic-assisted surgery (RAS). As with any new technology, concerns remain regarding the surgeon learning curve, operative efficiency, and safety profile of RAS compared to conventional techniques. This study evaluates the clinical utility of a RAS system (ROSA, Zimmer Biomet) in a public hospital setting, assessing its impact on procedure duration and adverse event incidence at 90 days postoperatively. Methods: A retrospective comparative cohort study was conducted at a secondary public hospital (Queen Elizabeth II Jubilee Hospital) in, Brisbane, Australia. Data was extracted from a departmental registry, electronic medical records, and intraoperative reports from September 2017 to February 2023. The study included 568 TKA cases: 173 instrumented or navigated TKAs performed before RAS introduction (Pre-RAS), 258 robotic-assisted TKAs after RAS adoption (RAS group), and 137 TKAs performed by other department surgeons who did not use RAS (non-RAS), serving as a benchmark for department-wide outcomes. The primary outcomes were procedure duration and adverse event incidence including surgical site infection (SSI), venous thromboembolism (VTE), knee stiffness, and all-cause readmission within 90 days postoperatively. Results: Among 67 recorded adverse events, no significant differences in total adverse event incidence were observed between the pre-RAS and RAS groups (12.1% vs. 11.6%, p = 0.78). A non-significant increase in superficial infections in males undergoing RAS-TKA was observed ( p = 0.062). The pre-RAS group had significantly longer operative times than the RAS group (128 ± 21.6 min vs. 121.4 ± 19.5 min, p < 0.01). The non-RAS department group had shorter procedure durations than the pre-RAS group (118.3 ± 20.1 min, p < 0.01). Conclusion: RAS-TKA was associated with shorter operative times and a comparable safety profile to non-robotic TKA in this cohort. Further investigation is warranted to determine whether these findings are maintained across different settings and over longer follow-up periods.
- Open Access
- 28 August 2025
- Published by Springer Nature in Archives of orthopaedic and trauma surgery
- Vol. 145 (1) , 1-12
High retention rates of custom 3D printed titanium implants in complex pelvic reconstruction, a report on 106 consecutive cases over 10 years
Introduction Access to custom 3D printed pelvic implants (3DPI) is improving for application in both arthroplasty revision and tumour reconstruction. There is limited evidence regarding the safety and outcomes of such implants for large bony defects of the pelvis. The aim of this study is to report the incidence of complications, patient mortality and implant survival following pelvic reconstruction using custom 3Dprinted prostheses in the setting of extensive pelvic bone defects following pelvic tumour resection or failure of total hip arthroplasty (THA). Materials and methods Patients who underwent reconstruction with a custom 3D printed pelvic prosthesis (3DPI) were identified from our clinical outcomes registry (Complex Reconstruction and Sarcoma Surgical Outcomes Registry; ANZCTRN 12621001421820). Indications for surgery, adverse events, reoperations and rates and modes of failure were recorded. Kaplan-Meier and multistate survival curves were generated for cumulative survival based on indication. Results One hundred and six procedures were completed (Revision THA = 33; Tumour Pelvis = 73) with a median follow up of 4.1 years, ranging from 0.6 to 10 years. Acetabular loosening was the most frequent indication for the Revision THA cohort, while indications for tumour varied across primary presentations, metastases and failures of previous resection/reconstruction. Intraoperative complications were observed in 4.1% (95%CI 1.1–12.3) of Tumour Pelvis cases. Overall implant retention was 96% (90–99). No mortality events were observed in the Revision THA cohort, with 5-year patient survival 79% (70–90) in the Tumour Pelvis cohort. Procedure-survival free from periprosthetic infection was 86% (74–100) in the Revision THA cohort and 85% (76–95) in the Tumour Pelvis cohort. Modelling adverse events using multistate survival models in both cohorts revealed complex time-varying presentation of adverse events, with a significant burden of reoperations and local tumour recurrence in the Tumour Pelvis cohort. Conclusions 3DPIs are a safe and viable option for complex reconstruction of the pelvis across a range of oncological and non-oncological indications. The initial results of the present study provide important information to aid in counselling patients about such procedures and allocating healthcare resources for ongoing care. Further work is required to document functional and biomechanical outcomes in these patient populations. Trial registration Australian New Zealand Clinical Trials Registry (ANZCTRN 12621001421820); Registration date 21-Oct-2021.
- 28 August 2025
- Published by Springer Nature in Archives of orthopaedic and trauma surgery
- Vol. 145 (1) , 1-12
Open AccessHigh retention rates of custom 3D printed titanium implants in complex pelvic reconstruction, a report on 106 consecutive cases over 10 years
Introduction Access to custom 3D printed pelvic implants (3DPI) is improving for application in both arthroplasty revision and tumour reconstruction. There is limited evidence regarding the safety and outcomes of such implants for large bony defects of the pelvis. The aim of this study is to report the incidence of complications, patient mortality and implant survival following pelvic reconstruction using custom 3Dprinted prostheses in the setting of extensive pelvic bone defects following pelvic tumour resection or failure of total hip arthroplasty (THA). Materials and methods Patients who underwent reconstruction with a custom 3D printed pelvic prosthesis (3DPI) were identified from our clinical outcomes registry (Complex Reconstruction and Sarcoma Surgical Outcomes Registry; ANZCTRN 12621001421820). Indications for surgery, adverse events, reoperations and rates and modes of failure were recorded. Kaplan-Meier and multistate survival curves were generated for cumulative survival based on indication. Results One hundred and six procedures were completed (Revision THA = 33; Tumour Pelvis = 73) with a median follow up of 4.1 years, ranging from 0.6 to 10 years. Acetabular loosening was the most frequent indication for the Revision THA cohort, while indications for tumour varied across primary presentations, metastases and failures of previous resection/reconstruction. Intraoperative complications were observed in 4.1% (95%CI 1.1–12.3) of Tumour Pelvis cases. Overall implant retention was 96% (90–99). No mortality events were observed in the Revision THA cohort, with 5-year patient survival 79% (70–90) in the Tumour Pelvis cohort. Procedure-survival free from periprosthetic infection was 86% (74–100) in the Revision THA cohort and 85% (76–95) in the Tumour Pelvis cohort. Modelling adverse events using multistate survival models in both cohorts revealed complex time-varying presentation of adverse events, with a significant burden of reoperations and local tumour recurrence in the Tumour Pelvis cohort. Conclusions 3DPIs are a safe and viable option for complex reconstruction of the pelvis across a range of oncological and non-oncological indications. The initial results of the present study provide important information to aid in counselling patients about such procedures and allocating healthcare resources for ongoing care. Further work is required to document functional and biomechanical outcomes in these patient populations. Trial registration Australian New Zealand Clinical Trials Registry (ANZCTRN 12621001421820); Registration date 21-Oct-2021.
- Open Access
- 10 June 2025
- Published by Springer Nature in Archives of orthopaedic and trauma surgery
- Vol. 145 (1) , 1-12
Stay or go? Outcomes of lower limb arthroplasty in patients travelling away from home for surgery: A cross-sectional analysis of the Australian Orthopaedic Association National Joint Replacement Registry (AOANJRR) comparing patient residence and hospital remoteness
Introduction: The relationship between remoteness of patient residence and post-surgical outcomes is yet to be examined. This study aimed to assess whether incidence of all-cause revision up to two years following primary total hip or knee arthroplasty varies with the remoteness of a patient’s residence at the time of surgery. Materials and Methods: Data from the Australian Orthopaedic Association National Joint Replacement Registry from 1-Sep-1999 to 31-Dec-2022 were analysed. The Modified Monash Model of remoteness classification categorised patient residence and hospital location into metro-regional and rural-remote. The primary outcome was all-cause revision within two years after surgery for primary total knee arthroplasty (TKA) and primary total hip arthroplasty (THA) for osteoarthritis as the primary diagnosis. Cumulative percent revision (CPR) rates with 95% confidence intervals (CI) were reported with hazard ratios (HR) between subgroups of residential and hospital remoteness. Results: Two-year CPR for primary TKA ranged from 1.8% (95% CI 1.7–1.9) to 2.2% (95% CI 1.8–2.7). Patients residing in rural-remote areas who travelled to metro-regional hospitals displayed significantly higher CPR following TKA compared to patients treated at rural-remote facilities (HR = 1.11, 95% CI 1.05–1.18, P = 0.001). Patients residing in rural-remote areas that stayed in-area for surgery displayed significantly reduced CPR compared to metro-regional patients that stayed in-area (HR = 0.90, 95%CI 0.85–0.95, P < 0.001). Infection was the dominant reason for TKA revision. No differences in revision risk were observed between patient and hospital combinations for primary THA. Conclusions: Travel distance, but not remoteness of a patient’s residence, may be associated with cumulative risk of early revision of primary TKA, particularly in regional/remote patients travelling out of area, but not for patients undergoing THA. Further work is needed to clarify whether revision differences are due to variability in the clinical threshold for offering revision arthroplasty between regional and metropolitan surgeons, or improved outcomes of the primary procedure.
- 10 June 2025
- Published by Springer Nature in Archives of orthopaedic and trauma surgery
- Vol. 145 (1) , 1-12
Open AccessStay or go? Outcomes of lower limb arthroplasty in patients travelling away from home for surgery: A cross-sectional analysis of the Australian Orthopaedic Association National Joint Replacement Registry (AOANJRR) comparing patient residence and hospital remoteness
Introduction: The relationship between remoteness of patient residence and post-surgical outcomes is yet to be examined. This study aimed to assess whether incidence of all-cause revision up to two years following primary total hip or knee arthroplasty varies with the remoteness of a patient’s residence at the time of surgery. Materials and Methods: Data from the Australian Orthopaedic Association National Joint Replacement Registry from 1-Sep-1999 to 31-Dec-2022 were analysed. The Modified Monash Model of remoteness classification categorised patient residence and hospital location into metro-regional and rural-remote. The primary outcome was all-cause revision within two years after surgery for primary total knee arthroplasty (TKA) and primary total hip arthroplasty (THA) for osteoarthritis as the primary diagnosis. Cumulative percent revision (CPR) rates with 95% confidence intervals (CI) were reported with hazard ratios (HR) between subgroups of residential and hospital remoteness. Results: Two-year CPR for primary TKA ranged from 1.8% (95% CI 1.7–1.9) to 2.2% (95% CI 1.8–2.7). Patients residing in rural-remote areas who travelled to metro-regional hospitals displayed significantly higher CPR following TKA compared to patients treated at rural-remote facilities (HR = 1.11, 95% CI 1.05–1.18, P = 0.001). Patients residing in rural-remote areas that stayed in-area for surgery displayed significantly reduced CPR compared to metro-regional patients that stayed in-area (HR = 0.90, 95%CI 0.85–0.95, P < 0.001). Infection was the dominant reason for TKA revision. No differences in revision risk were observed between patient and hospital combinations for primary THA. Conclusions: Travel distance, but not remoteness of a patient’s residence, may be associated with cumulative risk of early revision of primary TKA, particularly in regional/remote patients travelling out of area, but not for patients undergoing THA. Further work is needed to clarify whether revision differences are due to variability in the clinical threshold for offering revision arthroplasty between regional and metropolitan surgeons, or improved outcomes of the primary procedure.
- 2 December 2024
- Published by Elsevier in Australasian Emergency Care
- Vol. 28 (2) , 110-115
The Clinical Frailty Scale offers little utility as part of a prediction model for community-dwelling older fallers at risk of re-presenting to the emergency department.
- 2 December 2024
- Published by Elsevier in Australasian Emergency Care
- Vol. 28 (2) , 110-115
The Clinical Frailty Scale offers little utility as part of a prediction model for community-dwelling older fallers at risk of re-presenting to the emergency department.
- Open Access
High retention rates of custom 3D printed titanium implants in complex pelvic reconstruction, a report on 106 consecutive cases over 10 years
Background: Access to custom 3D printed pelvic implants (3DPI) is improving for application in both arthroplasty revision and tumour reconstruction. There is limited evidence regarding the safety and outcomes of such implants for large bony defects of the pelvis. Purpose: To report the incidence of complications, patient mortality and implant survival following pelvic reconstruction using custom 3Dprinted prostheses in the setting of extensive pelvic bone defects following pelvic tumour resection or failure of total hip arthroplasty (THA) Methods: Patients who underwent reconstruction with a custom 3D printed pelvic prosthesis (3DPI) were identified from our clinical outcomes registry (Complex Reconstruction and Sarcoma Surgical Outcomes Registry; ANZCTRN 12621001421820). Indications for surgery, adverse events, reoperations and rates and modes of failure were recorded. Kaplan-Meier and multistate survival curves were generated for cumulative survival based on indication. Results: One hundred and six procedures were completed(RevisionTHA = 33; TumourPelvis = 73) with a median follow up of 4.1 years, ranging from 0.6 to 10 years. Acetabular loosening was the most frequent indication for the RevisionTHA cohort, while indications for tumour varied across primary presentations, metastases and failures of previous resection/reconstruction. Intraoperative complications were observed in 4.1% (95%CI 1.1 - 12.3) of TumourPelvis cases. Overall implant retention was 96% (90 - 99). No mortality events were observed in the RevisionTHA cohort, with 5-year patient survival 79% (70-90) in the TumourPelvis cohort. Procedure-survival free from periprosthetic infection was 86% (74-100) in the RevisionTHA cohort and 85% (76 - 95) in the TumourPelvisCohort. Modelling adverse events using multistate survival models in both cohorts revealed complex time-varying presentation of adverse events, with a significant burden of reoperations and local tumour recurrence in the TumourPelvis cohort. Conclusion: 3DPIs are a safe and viable option for complex reconstruction of the pelvis across a range of oncological and non-oncological indications. The initial results of the present study provide important information to aid in counselling patients about such procedures and allocating healthcare resources for ongoing care. Further work is required to document functional and biomechanical outcomes in these patient populations.
Open AccessHigh retention rates of custom 3D printed titanium implants in complex pelvic reconstruction, a report on 106 consecutive cases over 10 years
Background: Access to custom 3D printed pelvic implants (3DPI) is improving for application in both arthroplasty revision and tumour reconstruction. There is limited evidence regarding the safety and outcomes of such implants for large bony defects of the pelvis. Purpose: To report the incidence of complications, patient mortality and implant survival following pelvic reconstruction using custom 3Dprinted prostheses in the setting of extensive pelvic bone defects following pelvic tumour resection or failure of total hip arthroplasty (THA) Methods: Patients who underwent reconstruction with a custom 3D printed pelvic prosthesis (3DPI) were identified from our clinical outcomes registry (Complex Reconstruction and Sarcoma Surgical Outcomes Registry; ANZCTRN 12621001421820). Indications for surgery, adverse events, reoperations and rates and modes of failure were recorded. Kaplan-Meier and multistate survival curves were generated for cumulative survival based on indication. Results: One hundred and six procedures were completed(RevisionTHA = 33; TumourPelvis = 73) with a median follow up of 4.1 years, ranging from 0.6 to 10 years. Acetabular loosening was the most frequent indication for the RevisionTHA cohort, while indications for tumour varied across primary presentations, metastases and failures of previous resection/reconstruction. Intraoperative complications were observed in 4.1% (95%CI 1.1 - 12.3) of TumourPelvis cases. Overall implant retention was 96% (90 - 99). No mortality events were observed in the RevisionTHA cohort, with 5-year patient survival 79% (70-90) in the TumourPelvis cohort. Procedure-survival free from periprosthetic infection was 86% (74-100) in the RevisionTHA cohort and 85% (76 - 95) in the TumourPelvisCohort. Modelling adverse events using multistate survival models in both cohorts revealed complex time-varying presentation of adverse events, with a significant burden of reoperations and local tumour recurrence in the TumourPelvis cohort. Conclusion: 3DPIs are a safe and viable option for complex reconstruction of the pelvis across a range of oncological and non-oncological indications. The initial results of the present study provide important information to aid in counselling patients about such procedures and allocating healthcare resources for ongoing care. Further work is required to document functional and biomechanical outcomes in these patient populations.
- Open Access
Stay or go? Outcomes of lower limb arthroplasty in patients travelling away from home for surgery: A cross-sectional analysis of the AOANJRR comparing patient residence and hospital remoteness
Purpose The relationship between remoteness of patient residence and post-surgical outcomes, such as early implant revision, has yet to be examined. The aim of this study was to assess whether the incidence of all-cause revision at up to 2 years following primary hip or knee total joint arthroplasty varies with the remoteness of a person’s place of residence at the time of the primary procedure. Methods An analysis was performed of data from the Australian Orthopaedic Association National Joint Replacement Registry (AOANJRR) from 1 Sept 1999 to 31 Dec 2022. The Modified Monash Model (2015) of remoteness classification was used to categorise patient residence and hospital location into metro-regional (MM 1-2) and rural-remote (MM 3-7). All-cause revision within the two-year period after surgery for primary total knee arthroplasty (TKA) and primary total hip arthroplasty (THA) for osteoarthritis as the primary diagnosis was selected as the primary outcome. A directed-acyclic graph approach was used to prioritise covariates for inclusion in a Cox proportional hazards regression model. Cumulative percent revision (CPR) rates with 95% confidence intervals was reported with hazard ratios between subgroups of residential and hospital remoteness. Results The two-year CPR for primary TKA ranged from 1.8% (95% CI 1.7 - 1.9) to 2.2% (95% CI 1.8 - 2.7). Patients residing in rural-remote areas who travelled to a metro-regional hospital displayed a significantly higher rate of revision following TKA compared to patients that were treated at a rural-remote hospital (HR: 1.11, 95% CI 1.05 - 1.18, P = 0.001) within two-year follow-up of the primary procedure. Patients residing in rural-remote areas that stayed in these areas for their operation displayed a significantly reduced revision rate compared to metro-regional patients that stayed in-area for their joint replacement (HR=0.90, 95%CI 0.85 - 0.95, P Conclusions Travel distance, but not remoteness of a patient’s place of residence may be associated with cumulative risk of early revision (within 2 years) of primary TKA, particularly in regional/remote patients travelling out of area, but not for patients undergoing THA. Further work linking service utilisation prior to a revision procedure is required to clarify whether differences in revision between remoteness and travel distances are due to variability in the clinical threshold for offering revision arthroplasty between regional and metropolitan surgeons or improved outcomes of the primary procedure.
Open AccessStay or go? Outcomes of lower limb arthroplasty in patients travelling away from home for surgery: A cross-sectional analysis of the AOANJRR comparing patient residence and hospital remoteness
Purpose The relationship between remoteness of patient residence and post-surgical outcomes, such as early implant revision, has yet to be examined. The aim of this study was to assess whether the incidence of all-cause revision at up to 2 years following primary hip or knee total joint arthroplasty varies with the remoteness of a person’s place of residence at the time of the primary procedure. Methods An analysis was performed of data from the Australian Orthopaedic Association National Joint Replacement Registry (AOANJRR) from 1 Sept 1999 to 31 Dec 2022. The Modified Monash Model (2015) of remoteness classification was used to categorise patient residence and hospital location into metro-regional (MM 1-2) and rural-remote (MM 3-7). All-cause revision within the two-year period after surgery for primary total knee arthroplasty (TKA) and primary total hip arthroplasty (THA) for osteoarthritis as the primary diagnosis was selected as the primary outcome. A directed-acyclic graph approach was used to prioritise covariates for inclusion in a Cox proportional hazards regression model. Cumulative percent revision (CPR) rates with 95% confidence intervals was reported with hazard ratios between subgroups of residential and hospital remoteness. Results The two-year CPR for primary TKA ranged from 1.8% (95% CI 1.7 - 1.9) to 2.2% (95% CI 1.8 - 2.7). Patients residing in rural-remote areas who travelled to a metro-regional hospital displayed a significantly higher rate of revision following TKA compared to patients that were treated at a rural-remote hospital (HR: 1.11, 95% CI 1.05 - 1.18, P = 0.001) within two-year follow-up of the primary procedure. Patients residing in rural-remote areas that stayed in these areas for their operation displayed a significantly reduced revision rate compared to metro-regional patients that stayed in-area for their joint replacement (HR=0.90, 95%CI 0.85 - 0.95, P Conclusions Travel distance, but not remoteness of a patient’s place of residence may be associated with cumulative risk of early revision (within 2 years) of primary TKA, particularly in regional/remote patients travelling out of area, but not for patients undergoing THA. Further work linking service utilisation prior to a revision procedure is required to clarify whether differences in revision between remoteness and travel distances are due to variability in the clinical threshold for offering revision arthroplasty between regional and metropolitan surgeons or improved outcomes of the primary procedure.
- Open Access
Low incidence of adverse events or construct failure of a novel high-strength No.2 round suture in rotator cuff repair: An IDEAL Stage 2a assessment retrospective cohort analysis
Background Despite technical and material improvements in rotator cuff repair (RCR) clinical and radiological failure remains common. Following suture fixation, tension and footprint compression decrease from time zero. A novel suture (Dynacord, Depuy Synthes) has been designed to shorten when submerged in liquid to maintain tension and increase repair construct security. Methods A retrospective cohort analysis was performed on the PRULO (Patient Reported Outcomes in Upper Limb Surgery) registry for 12 months follow up after RCR using this suture regarding all cause failure, rates of common complications, Quick Disability of the Arm, Shoulder and Hand (QuickDASH), and Western Ontario Rotator Cuff Index (WORC). Summary statistics were generated for patient characteristics and patient-reported outcome measures (PROMs) analysed using multiple imputation and a linear model to assess changes over 12 months follow up. Results A cohort of 236 cases was included for analysis. Complication rates and functional improvements were comparable to literature on similar sutures. At 12 months follow up, all-cause failure occurred in 12% of cases, and mean scores for QuickDASH decreased by 37 and WORC increased by 44, both of which surpass the minimum clinically important difference. Our observed rates of complications are as follows: Infection 2.1%, stiffness/capsulitis 11% and retear 12%. Conclusion The novel suture demonstrated favourable safety and efficacy profiles, with outcomes comparable to those published for commonly used sutures. This study through an IDEAL 2a framework for surgical innovation highlights this suture as safe, effective in mitigating common failure mechanisms and having satisfactory outcomes in RCR.
Open AccessLow incidence of adverse events or construct failure of a novel high-strength No.2 round suture in rotator cuff repair: An IDEAL Stage 2a assessment retrospective cohort analysis
Background Despite technical and material improvements in rotator cuff repair (RCR) clinical and radiological failure remains common. Following suture fixation, tension and footprint compression decrease from time zero. A novel suture (Dynacord, Depuy Synthes) has been designed to shorten when submerged in liquid to maintain tension and increase repair construct security. Methods A retrospective cohort analysis was performed on the PRULO (Patient Reported Outcomes in Upper Limb Surgery) registry for 12 months follow up after RCR using this suture regarding all cause failure, rates of common complications, Quick Disability of the Arm, Shoulder and Hand (QuickDASH), and Western Ontario Rotator Cuff Index (WORC). Summary statistics were generated for patient characteristics and patient-reported outcome measures (PROMs) analysed using multiple imputation and a linear model to assess changes over 12 months follow up. Results A cohort of 236 cases was included for analysis. Complication rates and functional improvements were comparable to literature on similar sutures. At 12 months follow up, all-cause failure occurred in 12% of cases, and mean scores for QuickDASH decreased by 37 and WORC increased by 44, both of which surpass the minimum clinically important difference. Our observed rates of complications are as follows: Infection 2.1%, stiffness/capsulitis 11% and retear 12%. Conclusion The novel suture demonstrated favourable safety and efficacy profiles, with outcomes comparable to those published for commonly used sutures. This study through an IDEAL 2a framework for surgical innovation highlights this suture as safe, effective in mitigating common failure mechanisms and having satisfactory outcomes in RCR.
- Open Access
Stage 2a IDEAL evaluation of a third-generation biocomposite suture anchor in arthroscopic rotator cuff repair: Subgroup cohort analysis of the PRULO registry with 12-month follow up
Background: Poly-lactic co-glycolide with tricalcium phosphate (PLGA)/β-TCP is both bioactive and biodegradable, and is considered a third generation biomaterial for suture anchors. This study aims to describe the incidence of adverse events and the trajectory of patient-reported outcomes up to 12 months follow up in patients undergoing rotator cuff repair with this type of anchor. Methods: A sub-group analysis of a prospective clinical registry embedded in an orthopaedic clinic was conducted. Patients undergoing surgery with the Healix Advance BR were identified and data on patient demographics, treatment details, complications and adverse events, as well as patient-reported outcomes (QuickDASH, WORC Index Normalised) were retrieved. Summary statistics were generated for patient characteristics and PROMs analysed using multiple imputation and a linear model to assess changes between baseline and 12 month follow up. Results: A consecutive cohort of 68 cases receiving the anchor of interest was included for analysis. Complications were recorded in six cases (8.8%, 95%CI 3.6 - 18.9), presenting as postoperative capsulitis/stiffness (N=3), persistent shoulder pain (N=1), a case of hemi-diaphragm palsy and a case of complex regional pain syndrome in the hand. No infections or reoperations were encountered in this series. The QuickDASH scores improved significantly from 45 (IQR 34-57) preoperatively to 5 (IQR 2-22) at 12 months. WORC Index scores improved from 46 (IQR 27-60) preoperatively to 85 (IQR 62-93) at 12 months. Conclusion: This study found a low incidence of adverse events, no requirement for reoperation or revision, and favourable recovery of patient-reported outcomes in patients treated with arthroscopic rotator cuff repair with a third-generation biocomposite suture anchor at up to 12 months follow up.
Open AccessStage 2a IDEAL evaluation of a third-generation biocomposite suture anchor in arthroscopic rotator cuff repair: Subgroup cohort analysis of the PRULO registry with 12-month follow up
Background: Poly-lactic co-glycolide with tricalcium phosphate (PLGA)/β-TCP is both bioactive and biodegradable, and is considered a third generation biomaterial for suture anchors. This study aims to describe the incidence of adverse events and the trajectory of patient-reported outcomes up to 12 months follow up in patients undergoing rotator cuff repair with this type of anchor. Methods: A sub-group analysis of a prospective clinical registry embedded in an orthopaedic clinic was conducted. Patients undergoing surgery with the Healix Advance BR were identified and data on patient demographics, treatment details, complications and adverse events, as well as patient-reported outcomes (QuickDASH, WORC Index Normalised) were retrieved. Summary statistics were generated for patient characteristics and PROMs analysed using multiple imputation and a linear model to assess changes between baseline and 12 month follow up. Results: A consecutive cohort of 68 cases receiving the anchor of interest was included for analysis. Complications were recorded in six cases (8.8%, 95%CI 3.6 - 18.9), presenting as postoperative capsulitis/stiffness (N=3), persistent shoulder pain (N=1), a case of hemi-diaphragm palsy and a case of complex regional pain syndrome in the hand. No infections or reoperations were encountered in this series. The QuickDASH scores improved significantly from 45 (IQR 34-57) preoperatively to 5 (IQR 2-22) at 12 months. WORC Index scores improved from 46 (IQR 27-60) preoperatively to 85 (IQR 62-93) at 12 months. Conclusion: This study found a low incidence of adverse events, no requirement for reoperation or revision, and favourable recovery of patient-reported outcomes in patients treated with arthroscopic rotator cuff repair with a third-generation biocomposite suture anchor at up to 12 months follow up.
- Open Access
- 5 December 2023
- Published by Springer Nature in Arthroplasty
- Vol. 5 (1) , 1-10
CT validation of intraoperative imageless navigation (Naviswiss) for component positioning accuracy in primary total hip arthroplasty in supine patient position: a prospective observational cohort study in a single-surgeon practice
Background: The aim of this study was to report on the validity of the Naviswiss handheld image-free navigation device for accurate intraoperative measurement of THA component positioning, in comparison with the three-dimensional (3D) reconstruction of computed tomography (CT) images as the gold standard. Methods: A series of patients presenting to a single-surgeon clinic with end-stage hip osteoarthritis received primary hip arthroplasty with the anterolateral muscle-sparing surgical approach in the supine position. Imageless navigation was applied during the procedure with bone-mounted trackers applied to the greater trochanter and ASIS. Patients underwent routine CT scans before and after surgery and these were analyzed by using three-dimensional reconstruction to generate cup orientation, offset and leg length changes, which were compared to the intraoperative measurements provided by the navigation system. Estimates of agreement between the intraoperative and image-derived measurements were assessed with and without correction for bias and declared cases with potential measurement issues. Results: The mean difference between intraoperative and postoperative CT measurements was within 2° for angular measurements and 2 mm for leg length. Absolute differences for the two indices were between 5° and 4 mm. Mean bias was 1.9°–3.6° underestimation for cup orientation and up to 2 mm overestimation for leg length change, but absolute thresholds of 10° and 10 mm were not exceeded by 95% limits of agreement (LOA), especially after correction for bias. Four cases (12%) were declared intraoperatively for issues with fixation on the greater trochanter. Inclusion of these cases generated acceptable accuracy overall and their omission failed to improve between-case variability in accuracy or LOA for both offset and leg length. Conclusions: The accuracy of the Naviswiss system applied during primary THA in a supine position and anterolateral surgical approach falls within clinically acceptable recommendations for acetabular cup placement, femoral offset, and length. With refinements to surgical technique to adapt to the navigation hardware, the system could be further improved with regression-based bias correction. Trial registration: Registered with the Australian New Zealand Clinical Trials Registry (ACTRN12618000317291)
- 5 December 2023
- Published by Springer Nature in Arthroplasty
- Vol. 5 (1) , 1-10
Open AccessCT validation of intraoperative imageless navigation (Naviswiss) for component positioning accuracy in primary total hip arthroplasty in supine patient position: a prospective observational cohort study in a single-surgeon practice
Background: The aim of this study was to report on the validity of the Naviswiss handheld image-free navigation device for accurate intraoperative measurement of THA component positioning, in comparison with the three-dimensional (3D) reconstruction of computed tomography (CT) images as the gold standard. Methods: A series of patients presenting to a single-surgeon clinic with end-stage hip osteoarthritis received primary hip arthroplasty with the anterolateral muscle-sparing surgical approach in the supine position. Imageless navigation was applied during the procedure with bone-mounted trackers applied to the greater trochanter and ASIS. Patients underwent routine CT scans before and after surgery and these were analyzed by using three-dimensional reconstruction to generate cup orientation, offset and leg length changes, which were compared to the intraoperative measurements provided by the navigation system. Estimates of agreement between the intraoperative and image-derived measurements were assessed with and without correction for bias and declared cases with potential measurement issues. Results: The mean difference between intraoperative and postoperative CT measurements was within 2° for angular measurements and 2 mm for leg length. Absolute differences for the two indices were between 5° and 4 mm. Mean bias was 1.9°–3.6° underestimation for cup orientation and up to 2 mm overestimation for leg length change, but absolute thresholds of 10° and 10 mm were not exceeded by 95% limits of agreement (LOA), especially after correction for bias. Four cases (12%) were declared intraoperatively for issues with fixation on the greater trochanter. Inclusion of these cases generated acceptable accuracy overall and their omission failed to improve between-case variability in accuracy or LOA for both offset and leg length. Conclusions: The accuracy of the Naviswiss system applied during primary THA in a supine position and anterolateral surgical approach falls within clinically acceptable recommendations for acetabular cup placement, femoral offset, and length. With refinements to surgical technique to adapt to the navigation hardware, the system could be further improved with regression-based bias correction. Trial registration: Registered with the Australian New Zealand Clinical Trials Registry (ACTRN12618000317291)
- Open Access
Multidimensional analysis of preoperative patient-reported outcomes identifies distinct phenotypes in patients booked for total knee arthroplasty: Secondary analysis of the SHARKS registry in a metropolitan hospital department
Aims Traditional research on total knee arthroplasty (TKA) has predominantly utilised individual preoperative patient-reported outcome measures (PROMs) to predict postoperative satisfaction. The objective of this study was to leverage the power of machine learning to simultaneously analyse multiple PROMs, thus unveiling unique patient phenotypes within this heterogeneous population. This study aimed to identify phenotypes in patients scheduled for TKA using multidimensional analysis of preoperative PROMs and evaluate their correlation with patient characteristics. Methods Patients booked for primary TKA between 2017 and 2021 at a metropolitan public hospital were enrolled in the clinical quality registry (SHARKS) maintained by the orthopaedics department. The registry collected demographic and clinical data, including PROMs such as the Veterans Rand 12 (VR-12) and Oxford Knee Score (OKS). The imputed data was used for the primary analysis, which involved clustering patients based on their responses to VR-12 and OKS subscale scores using a k-means clustering algorithm. A k value of 4 was chosen to identify four distinct phenotypes. ANOVA was used to compare average scores in each cluster. Relationships between phenotype and patient age, sex, body mass index (BMI), and laterality were determined using nominal logistic regression Results There were 389 patients and 450 primary knees included in the study (49.6% females and 50.4% males). The cluster analysis categorised patients into four distinct phenotypes based on VR-12 PCS, VR-12 MCS, OKS-F, and OKS-P scores. Patients in phenotype 3 (Mild symptoms with good mental health) reported superior physical function, less pain, and higher mental and general health scores, while those in phenotype 2 (Severe symptoms with poor mental health) experienced the greatest knee pain, impairment, and poorer physical and mental health. Notably, phenotype 4 (Moderate symptoms with good mental health) patients reported high mental health scores despite significant knee pain and physical health impairment. Patient characteristics were significantly associated with phenotype. Patients in the Severe symptoms with poor mental health phenotype were significantly more likely to be younger, female, have a higher BMI, and exhibit bilateral OA compared to those in the Mild symptoms with good mental health phenotype (PConclusions This preliminary study employed a multidimensional data analysis method to identify phenotypes in OA patients based on commonly used PROMs. These phenotypes demonstrated significant associations with patient demographics. A key advantage of this approach is the capability to identify patterns that may not be discernible when interpreting PROMs independently. The use of cluster analysis demonstrates potential for developing prognostic models in joint replacement and warrants further research to improve clinical decision-making and patient outcomes.
Open AccessMultidimensional analysis of preoperative patient-reported outcomes identifies distinct phenotypes in patients booked for total knee arthroplasty: Secondary analysis of the SHARKS registry in a metropolitan hospital department
Aims Traditional research on total knee arthroplasty (TKA) has predominantly utilised individual preoperative patient-reported outcome measures (PROMs) to predict postoperative satisfaction. The objective of this study was to leverage the power of machine learning to simultaneously analyse multiple PROMs, thus unveiling unique patient phenotypes within this heterogeneous population. This study aimed to identify phenotypes in patients scheduled for TKA using multidimensional analysis of preoperative PROMs and evaluate their correlation with patient characteristics. Methods Patients booked for primary TKA between 2017 and 2021 at a metropolitan public hospital were enrolled in the clinical quality registry (SHARKS) maintained by the orthopaedics department. The registry collected demographic and clinical data, including PROMs such as the Veterans Rand 12 (VR-12) and Oxford Knee Score (OKS). The imputed data was used for the primary analysis, which involved clustering patients based on their responses to VR-12 and OKS subscale scores using a k-means clustering algorithm. A k value of 4 was chosen to identify four distinct phenotypes. ANOVA was used to compare average scores in each cluster. Relationships between phenotype and patient age, sex, body mass index (BMI), and laterality were determined using nominal logistic regression Results There were 389 patients and 450 primary knees included in the study (49.6% females and 50.4% males). The cluster analysis categorised patients into four distinct phenotypes based on VR-12 PCS, VR-12 MCS, OKS-F, and OKS-P scores. Patients in phenotype 3 (Mild symptoms with good mental health) reported superior physical function, less pain, and higher mental and general health scores, while those in phenotype 2 (Severe symptoms with poor mental health) experienced the greatest knee pain, impairment, and poorer physical and mental health. Notably, phenotype 4 (Moderate symptoms with good mental health) patients reported high mental health scores despite significant knee pain and physical health impairment. Patient characteristics were significantly associated with phenotype. Patients in the Severe symptoms with poor mental health phenotype were significantly more likely to be younger, female, have a higher BMI, and exhibit bilateral OA compared to those in the Mild symptoms with good mental health phenotype (PConclusions This preliminary study employed a multidimensional data analysis method to identify phenotypes in OA patients based on commonly used PROMs. These phenotypes demonstrated significant associations with patient demographics. A key advantage of this approach is the capability to identify patterns that may not be discernible when interpreting PROMs independently. The use of cluster analysis demonstrates potential for developing prognostic models in joint replacement and warrants further research to improve clinical decision-making and patient outcomes.