Alexander N. Moiseichenkov
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Alexander N. Moiseichenkov has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
A.R. Beketov
UrFU, Yekaterinburg, Russian Federation
1 shared publicationA.R. Shaikhiev
FSBES HPE Rostov State Transport University, Rostov-on-Don, Russian Federation
1 shared publicationA.T. Plastun
UrFU, Yekaterinburg, Russian Federation
1 shared publicationAlexander Bakhtin
National Research University of Electronic Technology (MIET), Moscow, Russia
1 shared publicationAnastasia Semenova
National Research University of Electronic Technology (MIET), Moscow, Russia
1 shared publication- Anna A. Dmitrieva
Department of Automated Electrical Systems, Ural Federal University, Yekaterinburg, Russia
1 shared publication
Latest Publications
- 16 November 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 4, 68-73
Adaptive Algorithm for Steam Turbine Fast Valving Based on the Equal Area Criterion and Synchrophasor Measurements
The paper describes development and testing of the adaptive algorithm of turbine fast valving control. The purpose is to ensure transient stability of a synchronous generator during a disturbance. The turbine fast valving control algorithm is synthesized based on the equal area criterion in terms of torque. Phasor Measurement Unit data was used to identify the inception of a transient event and its parameters. Adaptability of the algorithm is achieved by using minimal amount of previously obtained parameters of a synchronous generator and a power system under consideration. The algorithm was tested on the single-machine system with automatic excitation control, steam turbine and its governor being taken into account.
- 16 November 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 4, 68-73
Adaptive Algorithm for Steam Turbine Fast Valving Based on the Equal Area Criterion and Synchrophasor Measurements
The paper describes development and testing of the adaptive algorithm of turbine fast valving control. The purpose is to ensure transient stability of a synchronous generator during a disturbance. The turbine fast valving control algorithm is synthesized based on the equal area criterion in terms of torque. Phasor Measurement Unit data was used to identify the inception of a transient event and its parameters. Adaptability of the algorithm is achieved by using minimal amount of previously obtained parameters of a synchronous generator and a power system under consideration. The algorithm was tested on the single-machine system with automatic excitation control, steam turbine and its governor being taken into account.
- 1 January 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1198-1203
Predictive Analytics Usage for Power Transformer Operating Costs Optimization
The article presents the research results on the development of a method for parameter monitoring periodicity definition for reliable and effective power transformers (PT) state evaluation during operation.The method takes into account:• the intensity of damage to the elements of the PT, which are affected by the quality of transformer oil in terms of the duration of operation;• models of aging of materials of PT elements, taking into account the influence of design features and applied PT materials on the aging rate of insulation;• refined permissible and maximum permissible values of the monitored parameters, differentiated by the duration of operation, design features of the PT.Operational cost savings is achieved by parameters monitoring periodicity adjustment for every PT according to individual trends of parameters changing based on ageing models and specified criteria for evaluating the parameters.
- 1 January 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1198-1203
Predictive Analytics Usage for Power Transformer Operating Costs Optimization
The article presents the research results on the development of a method for parameter monitoring periodicity definition for reliable and effective power transformers (PT) state evaluation during operation.The method takes into account:• the intensity of damage to the elements of the PT, which are affected by the quality of transformer oil in terms of the duration of operation;• models of aging of materials of PT elements, taking into account the influence of design features and applied PT materials on the aging rate of insulation;• refined permissible and maximum permissible values of the monitored parameters, differentiated by the duration of operation, design features of the PT.Operational cost savings is achieved by parameters monitoring periodicity adjustment for every PT according to individual trends of parameters changing based on ageing models and specified criteria for evaluating the parameters.
- Open Access
- 27 November 2019
- Published by EDP Sciences in ITM Web of Conferences
- Vol. 30, 03001
5G base station prototyping: implementation possibilities in Russia
A brief overview of the development of 5G mobile communications in the world and in Russia is presented. 5G pilot projects in Russia are considered. The basic requirements for 5G networks, the tasks facing developers, examples of hardware and brief technical specifications of hardware produced in Russia that can be used to create base station equipment for 5G networks are given. The work of MIET on the development of software and algorithmic support for 5G transceiver equipment is described. An estimation is given concerning the feasibility of implementing 5G generation mobile communication base stations in Russia, including on the basis of hardware from Russian manufacturers.
- 27 November 2019
- Published by EDP Sciences in ITM Web of Conferences
- Vol. 30, 03001
Open Access5G base station prototyping: implementation possibilities in Russia
A brief overview of the development of 5G mobile communications in the world and in Russia is presented. 5G pilot projects in Russia are considered. The basic requirements for 5G networks, the tasks facing developers, examples of hardware and brief technical specifications of hardware produced in Russia that can be used to create base station equipment for 5G networks are given. The work of MIET on the development of software and algorithmic support for 5G transceiver equipment is described. An estimation is given concerning the feasibility of implementing 5G generation mobile communication base stations in Russia, including on the basis of hardware from Russian manufacturers.
- Open Access
- 11 July 2017
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 870 (1) , 012013
Comparing the techniques of defining the synchronous machine load angle
The low-frequency oscillations are natural for power systems and may arise due to both small variations of load and large disturbance. The effect of slight load changes may significantly differ for cases of low-magnitude permanent oscillations, which may be considered acceptable, and unstable oscillations, which may lead to a major system emergency. The existing trend of increasing the capacity of long-range power transmission has led to the situation where inter-area oscillations may appear underdamped or even rising in terms of magnitude. Effective oscillations detection with the corresponding countermeasures along with eliminating the prerequisites leading to the oscillations is a guarantee of minimizing their negative consequences. Therefore, it is of crucial importance to perform continuous monitoring which is to provide the information on the "source" of oscillations – a generator or a group of generators, which do not contribute to the oscillations damping or even support their development. The algorithm of quantitative estimation of synchronous generators participation in low-frequency oscillations damping based on synchronized phasor measurements has been proposed previously. It implies utilizing the concept of synchronizing power as a measure of the capability of the machine to maintain synchronous operation. The load angle of the generator is necessary to define the value of the synchronizing power and since the direct measurement of the load angle is generally not available the techniques of its derivation have been developed. The comparison of these techniques is presented with the estimation of the adopted assumptions effect on the synchronizing power evaluation results.
- 11 July 2017
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 870 (1) , 012013
Open AccessComparing the techniques of defining the synchronous machine load angle
The low-frequency oscillations are natural for power systems and may arise due to both small variations of load and large disturbance. The effect of slight load changes may significantly differ for cases of low-magnitude permanent oscillations, which may be considered acceptable, and unstable oscillations, which may lead to a major system emergency. The existing trend of increasing the capacity of long-range power transmission has led to the situation where inter-area oscillations may appear underdamped or even rising in terms of magnitude. Effective oscillations detection with the corresponding countermeasures along with eliminating the prerequisites leading to the oscillations is a guarantee of minimizing their negative consequences. Therefore, it is of crucial importance to perform continuous monitoring which is to provide the information on the "source" of oscillations – a generator or a group of generators, which do not contribute to the oscillations damping or even support their development. The algorithm of quantitative estimation of synchronous generators participation in low-frequency oscillations damping based on synchronized phasor measurements has been proposed previously. It implies utilizing the concept of synchronizing power as a measure of the capability of the machine to maintain synchronous operation. The load angle of the generator is necessary to define the value of the synchronizing power and since the direct measurement of the load angle is generally not available the techniques of its derivation have been developed. The comparison of these techniques is presented with the estimation of the adopted assumptions effect on the synchronizing power evaluation results.
- 1 May 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-3
Designing and testing a system of controlling a switched reluctance motor with ceramic insulation, using no pickups
The paper considers designing and testing a system of controlling a switched reluctance motors with ceramic insulation, using no pickups. The functional diagram of the SRM control soft-hardware component using no pickups and examples of currents' oscillograms of the SRM are demonstrated.
- 1 May 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-3
Designing and testing a system of controlling a switched reluctance motor with ceramic insulation, using no pickups
The paper considers designing and testing a system of controlling a switched reluctance motors with ceramic insulation, using no pickups. The functional diagram of the SRM control soft-hardware component using no pickups and examples of currents' oscillograms of the SRM are demonstrated.