DJDavid Jahoda

David Jahoda

*This is an algorithmically generated author record based on publicly available information.

David Jahoda has a total of 114 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Synovial fluid alpha-defensins in Lyme arthritis—a useful marker

    by Pavel Melicherčík, Matěj Mazura, Martin Hodík, Kamila Dundrová, Ivan Landor, David Jahoda, Rudolf Horváth, Vladislav Barták, René Kizek, Eva Klapková

    Lyme arthritis, one of the possible late manifestations of Lyme borreliosis, predominantly affects the supporting joints and in adults most often occurs in the form of monoarthritis of the knee. Early diagnosis is based on clinical findings and serology. PCR detection of Borrelia in synovial fluid has become an integral part of the laboratory testing algorithm. The clinical presentation and inflammatory markers in Lyme arthritis can resemble septic arthritis. Determining the levels of alpha-defensins (human neutrophil peptide (HNP 1–3)) in synovial fluid by liquid chromatography is a highly sensitive method revealing the presence of inflammatory process. Between 2020 and 2022, we examined eleven patients with Lyme arthritis of the knee. We measured levels of HNP 1–3 from synovial fluid by HPLC in patients, and we compared it with the corresponding C-reactive protein (CRP) levels in paired serum samples. In patients diagnosed with Lyme arthritis, HNP 1–3 levels in synovial fluid ranged from 2.5 to 261 mg/L, with a median of 46.5 mg/L. Average serum CRP was 43 mg/L. The results show that elevated HNP 1–3 can be consistent with not only septic arthritis or systemic disease, but also with Lyme arthritis, especially in patients with negative culture and 16S PCR from synovial fluid. Final diagnosis must be verified by examination for anti-Borrelia antibodies from serum and synovial fluid. The aim of this work is to introduce an HPLC method for the determination of alpha-defensins as one of the possible diagnostic markers.


  • Open Access

    Acidity Is an Excellent Marker of Infection in Hip and Knee Arthroplasty

    by Tobiáš Judl, Stanislav Popelka, Elena Tomšík, Martin Hrubý, Matěj Daniel, Jaroslav Fojt, Pavel Melicherčík, Ivan Landor, David Jahoda

    Background: The diagnosis of joint replacement infection is a difficult clinical challenge that often occurs when the implant cannot be salvaged. We hypothesize that the pH value of synovial fluid could be an important indicator of the inflammatory status of the joint. However, in the literature, there is a lack of data on the pH changes in hip and knee joint replacements and their relation to infection and implant failure. In this study, we aimed to measure the pH levels of synovial fluid in patients with hip and knee joint replacements. We also investigated the potential of pH measurement as a diagnostic tool for joint replacement infection. In this study, we recorded the pH values to be 7.55 and 7.46 in patients where Pseudomonas aeruginosa was identified as the cause of the prosthetic joint infection. We attribute this to the different environments created by this specific bacterium. In other cases where the pH was higher, chronic mitigated infections were diagnosed, caused by strains of Staphylococcus aureus, Streptococcus agalactiase, and coagulase negative staphylococcus. Materials and methods: In our cohort of 155 patients with implanted hip (THA; n = 85) or knee (TKA; n = 70) joint replacements, we conducted a prospective study with a pH measurement. Out of the whole cohort, 44 patients had confirmed joint replacement infection (28.4%) (44/155). In 111 patients, infection was ruled out (71.6%) (111/155). Joint replacement infection was classified according to the criteria of the Musculoskeletal Infection Society (MSIS) from 2018. Based on the measured values, we determined the cut-off level for the probability of ongoing inflammation. We also determined the sensitivity and specificity of the measurement. Results: The group of patients with infection (n = 44) had a significantly lower synovial fluid pH (pH = 6.98 ± 0.48) than the group of patients with no infection (n = 111, pH = 7.82 ± 0.29, p < 0.001). The corresponding median pH values were 7.08 for the patients with infection and 7.83 for the patients with no infection. When we determined the cut-off level of pH 7.4, the sensitivity level of infected replacements was 88.6%, and the specificity level of the measurement was 95.5%. The predictive value of a positive test was 88.6%, and the predictive value of a negative test was 95.5%. Conclusions: Our results confirm that it is appropriate to include a pH measurement in the diagnostic spectrum of hip and knee replacements. This diagnostic approach has the potential to provide continuous in vivo feedback, facilitated by specialized biosensors. The advantage of this method is the future incorporation of a pH-detecting sensor into intelligent knee and hip replacements that will assess pH levels over time. By integrating these biosensors into intelligent implants, the early detection of joint replacement infections could be achieved, enhancing proactive intervention strategies.


  • Open Access

    High-Performance Liquid Chromatography as a Novel Method for the Determination of α-Defensins in Synovial Fluid for Diagnosis of Orthopedic Infections

    by Pavel Melicherčík, Eva Klapková, Karel Kotaška, David Jahoda, Ivan Landor, Václav Čeřovský

    The α-defensins (AD) present in synovial fluid have been regarded as constituting the most accurate periprosthetic joint infection (PJI) biomarker. The methods most commonly used for estimating AD as a biomarker are the qualitative Synovasure® PJI tests, based on the technique of lateral flow, and quantitative enzyme-linked immunosorbent assay (ELISA). Here, we propose a novel test based on detecting α-defensins in synovial fluid by high-performance liquid chromatography (HPLC). Synovial fluid was collected from 157 patients diagnosed with PJI, infectious arthritis (IA), arthrosis, reactive arthritis, and rheumatoid arthritis. AD concentrations in the fluid were determined by HPLC, and these same samples were used for additional diagnostic analyses. The results were statistically processed to calculate cutoff concentrations for PJI and IA. HPLC testing showed a sensitivity of 94% and a specificity of 92% for diagnosis of PJI, and a sensitivity of 97% and a specificity of 87% for diagnosis of IA. Using HPLC, we detected in synovial fluid a combination of three α-defensins: human neutrophil peptides HNP1, HNP2, and HNP3. All measured AD concentration values shown in this work refer to the sum of these three individual concentrations. Our study shows that the HPLC method meets the conditions for measuring precise concentrations of the sum of AD and can be recommended as part of a diagnostic array for PJI and IA diagnostics. By this method, we have verified that higher levels of AD in synovial fluid can also be seen in rheumatoid illnesses, crystal arthropathies, and reactive arthritis.


  • PCR diagnostic system in the treatment of prosthetic joint infections

    by D. Jahoda, I. Landor, J. Benedík, D. Pokorný, T. Judl, V. Barták, I. Jahodová, P. Fulín, M. Síbek

    In our prospective study, we examined whether a multiplex PCR diagnostic method is suitable for the primary detection of pathogens. We also examined the possibility and sensitivity of detecting genes responsible for biofilm production and methicillin resistance. From 2007 to 2009, 94 patients were included in the study. A UNB (universal detection of 16S ribosomal bacterial DNA) and UNF (universal detection of pathogenic fungi) were used in the primary detection. A multiplex assay for biofilm production, methicillin resistance allowed us to distinguish between Gram positivity and negativity and to detect Staphylococci. From all the samples, the culture was positive in 53.2 % of cases, and by using the UNB method, we detected bacteria in 79.8 % of cases—the UNF detection of fungi was positive in 10.6 % of cases. In 75 % of positive findings, we detected a Gram-negative bacterium in 65.3 % of cases. In 47.2 % of Staphylococci detected, the ability to produce biofilm was confirmed. 61.1 % of the Staphylococci exhibited a methicillin resistance. Our multiplex scheme cannot yet fully replace microbial cultivation but can be a rational guide when choosing an appropriate antibiotic therapy in cases where the microbial culture is negative.


  • The effect of Vancomycin degradation products in the topical treatment of osteomyelitis

    by P Melichercik, E Klapkova, I Landor, T Judl, M Sibek, D Jahoda

    The effect of Vancomycin degradation products in the topical treatment of osteomyelitis


  • Spacers

    by Mustafa Citak, Jean-Noel Argenson, Bas Masri, Daniel Kendoff, Bryan Springer, Volker Alt, Andrea Baldini, Quanjun Cui, Gregory K. Deirmengian, Hernan del Sel, et al.


  • Spacers

    by Mustafa Citak, Jean-Noel Argenson, Bas Masri, Daniel Kendoff, Bryan Springer, Volker Alt, Andrea Baldini, Quanjun Cui, Gregory K Deirmengian, Hernan Del Sel, et al.


  • Bone grafts as vancomycin carriers in local therapy of resistant infections

    by P. Melicherčík, D. Jahoda, O. Nyč, E. Klapková, V. Barták, I. Landor, D. Pokorný, T. Judl, A. Sosna

    The level of an antibiotic capable of inhibiting the etiological agent at the site of infection is an essential prerequisite for successful antibiotic therapy. In some cases, locally applied antibiotics may compensate for limitations of systemic administration and shorten systemic therapy. We aimed at verifying to what extent vancomycin (Van) bound to ground bone grafts is usable in the treatment of serious infections. The levels of released Van significantly exceeded the Van minimum inhibitory concentration, which can suppress Van-sensitive staphylococci and Van intermediate Staphylococcus aureus, for the whole period of a 16-day measurement. Our results indicate that bone grafts can be used as Van carriers in therapy of osteomyelitis caused by Van-sensitive Staphylococcus strains.


  • Evaluation of MP4OX for Prevention of Perioperative Hypotension in Patients Undergoing Primary Hip Arthroplasty with Spinal Anesthesia

    by Christina I. Olofsson, Andrzej Z. Górecki, Ris Dirksen, Ivo Kofranek, Jacek A. Majewski, Tomasz Mazurkiewicz, David Jahoda, Bengt Fagrell, Peter E. Keipert, Yun J. Hardiman, et al.

    Background: MP4OX (oxygenated polyethylene glycol-modified hemoglobin) is an oxygen therapeutic agent with potential applications in clinical settings where targeted delivery of oxygen to ischemic tissues is required. The primary goal of this study was to investigate MP4OX for preventing hypotensive episodes. An additional goal was to establish the safety profile of MP4OX in a large surgical population. Methods: Patients (n = 367) from 18 active study sites in six countries, undergoing elective primary hip arthroplasty with spinal anesthesia, were randomized to receive MP4OX or hydroxyethyl starch 130/0.4. Patients received a 250-ml dose at induction of spinal anesthesia and a second 250-ml dose if the protocol-specified trigger (predefined decrease in systolic blood pressure) was reached. The primary end point was the proportion of patients who developed one or more hypotensive episodes. Results: The proportion of patients with one or more hypotensive episodes was significantly lower (P < 0.0001) in the MP4OX group (66.1%) versus controls receiving hydroxyethyl starch 130/0.4 (90.2%). More MP4OX-treated patients experienced adverse events compared with controls (72.7% vs. 61.4%; P = 0.026). Transient elevations in laboratory values (e.g., alanine aminotransferase, aspartate aminotransferase, lipase, and troponin concentrations) occurred more frequently in the MP4OX group. There were no significant differences in the incidence of serious adverse events or in the composite morbidity and ischemia outcome end points, but nausea and hypertension were reported more often in MP4OX-treated patients. Conclusion: MP4OX significantly reduced the incidence of hypotensive episodes in patients undergoing hip arthroplasty, but the adverse event profile does not support use in routine low-risk surgical patients for the indication evaluated in this study.


  • A Double-Blind, Randomized, Multicenter Study of MP4OX for Treatment of Perioperative Hypotension in Patients Undergoing Primary Hip Arthroplasty Under Spinal Anesthesia

    by Philippe van der Linden, Tadeusz S. Gazdzik, David Jahoda, René J. Heylen, Jan C. Skowronski, David Pellar, Ivo Kofranek, Andrzej Z. Górecki, Bengt Fagrell, Peter E. Keipert, et al.

    MP4OX (oxygenated polyethylene glycol-modified hemoglobin) is a novel oxygen therapeutic agent specifically developed to perfuse and oxygenate tissue at risk for ischemia and hypoxia. In this study, we investigated the ability of MP4OX to treat hypotensive episodes. In addition, the tolerability profile of MP4OX in a large surgical population was established. Patients from 21 study sites in 5 countries, scheduled to undergo primary hip arthroplasty under spinal anesthesia, were randomized in a double-blind manner to receive MP4OX or hydroxyethyl starch (HES) solution (Voluven®; HES 130/0.4). Patients received the first 250-mL dose of investigational product when systolic blood pressure decreased to the predefined dosing trigger. A second 250-mL dose was given only if the systolic blood pressure decreased to the same trigger level after administration of the first dose. The primary efficacy outcome was total duration of all hypotensive episodes during surgery and the first 6 hours after skin closure. Of the 474 patients randomized, 405 reached the dosing trigger and received at least 1 dose. The mean total duration of all hypotensive episodes was significantly shorter (P < 0.0001) in the MP4OX group (52.4 ± 71.50 minutes; range, 3-442 minutes) compared with the HES group (137.6 ± 120.21 minutes; range, 5-435 minutes). The overall incidence of adverse events (AEs) in the intent-to-treat population was similar between the MP4OX and HES groups (75.2% vs 73.4%; P = 0.733). Transient increases in laboratory values were reported in more patients in the MP4OX group versus HES controls for aspartate aminotransferase (13.4% vs 7.4%; P = 0.052), alanine aminotransferase (6.9% vs 4.9%; P = 0.409), lipase (9.7% vs 3.6%; P = 0.015), and troponin (8.1% vs 2.0%; P = 0.006). There was no significant difference in the incidence of serious AEs reported (6.4% in MP4OX group vs 3.0% in HES controls; P = 0.106). Certain AEs did occur more frequently in the MP4OX group, including nausea (23.8% vs 14.3%; P = 0.016), bradycardia (14.9% vs 5.9%; P = 0.003), hypertension (8.4% vs 2.5%; P = 0.009), and oliguria (5.9% vs 1.5%; P = 0.019). The composite morbidity and ischemia end points did not reveal any differences between the 2 treatment groups. Administration of MP4OX achieved the end point of treating perioperative hypotension in patients undergoing primary hip arthroplasty under spinal anesthesia. The study was not powered to demonstrate clinical benefit based on the composite morbidity or ischemia outcomes. Although efficacy end points with sufficient power were met, MP4OX is not being proposed for use in routine surgery where the risk-benefit profile would not be favorable based on the safety profile demonstrated in this study.