Chih-Wen Chi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Chih-Wen Chi has a total of 32 co-authors. Here are the top co-authors by number of shared publications:
- Chun-Pin Lin
Graduate Institute of Clinical Dentistry, School of Dentistry, National Taiwan University, Taipei, Taiwan
6 shared publications - Chow-Shing Shin
Department of Mechanical Engineering, National Taiwan University, No. 1, Sec. 4, Roosevelt Road, Taipei 10617, Taiwan
3 shared publications Chao-Yuan Liu
Institute of Applied Mechanics, National Taiwan University, Taipei, Taiwan
1 shared publicationCheng-Ta Lai
Division of Colon and Rectal Surgery, Department of Surgery, Mackay Memorial Hospital, Taipei, Taiwan
1 shared publicationChia-Chieh Chang
Graduate Institute of Clinical Dentistry, School of Dentistry, National Taiwan University, Taipei, Taiwan
1 shared publication- Chien-An Chen
Department of Nephrology Tainan Sinlau Hospital Tainan Taiwan
1 shared publication
Latest Publications
- Open Access
- 31 December 2024
- Published by Elsevier in Journal of Endodontics
- Vol. 51 (4) , 507-513
The Novel Assessment to Explore the Cutting Performance of Rotary Instruments Using Dynamic Finite Element Analysis With Failure Mode
- 31 December 2024
- Published by Elsevier in Journal of Endodontics
- Vol. 51 (4) , 507-513
Open AccessThe Novel Assessment to Explore the Cutting Performance of Rotary Instruments Using Dynamic Finite Element Analysis With Failure Mode
- Open Access
- 24 October 2024
- Published by Elsevier in Journal of Dental Sciences
- Vol. 20 (1) , 61-68
Investigation of the cushioning mechanism of a novel dental implant system with composite hydrogel
- 24 October 2024
- Published by Elsevier in Journal of Dental Sciences
- Vol. 20 (1) , 61-68
Open AccessInvestigation of the cushioning mechanism of a novel dental implant system with composite hydrogel
- 1 October 2017
- Published by Elsevier in International Immunopharmacology
- Vol. 51, 25-30
Daphnoretin modulates differentiation and maturation of human dendritic cells through down-regulation of c-Jun N-terminal kinase
- 1 October 2017
- Published by Elsevier in International Immunopharmacology
- Vol. 51, 25-30
Daphnoretin modulates differentiation and maturation of human dendritic cells through down-regulation of c-Jun N-terminal kinase
- Open Access
- 1 May 2017
- Published by Elsevier in Journal of the Formosan Medical Association
- Vol. 116 (5) , 373-379
Fracture resistance of dental nickel–titanium rotary instruments with novel surface treatment: Thin film metallic glass coating
- 1 May 2017
- Published by Elsevier in Journal of the Formosan Medical Association
- Vol. 116 (5) , 373-379
Open AccessFracture resistance of dental nickel–titanium rotary instruments with novel surface treatment: Thin film metallic glass coating
- Open Access
- 1 April 2017
- Published by Elsevier in Journal of the Formosan Medical Association
- Vol. 116 (4) , 306-312
Cyclic fatigue behavior of nickel–titanium dental rotary files in clinical simulated root canals
- 1 April 2017
- Published by Elsevier in Journal of the Formosan Medical Association
- Vol. 116 (4) , 306-312
Open AccessCyclic fatigue behavior of nickel–titanium dental rotary files in clinical simulated root canals
- Open Access
- 1 March 2017
- Published by Elsevier in Journal of Dental Sciences
- Vol. 12 (1) , 21-26
Influence of heat treatment on cyclic fatigue and cutting efficiency of ProTaper Universal F2 instruments
- 1 March 2017
- Published by Elsevier in Journal of Dental Sciences
- Vol. 12 (1) , 21-26
Open AccessInfluence of heat treatment on cyclic fatigue and cutting efficiency of ProTaper Universal F2 instruments
- 1 November 2014
- Published by Elsevier in Journal of the Formosan Medical Association
- Vol. 113 (11) , 850-856
Erosive potential of soft drinks on human enamel: An in vitro study
- 1 November 2014
- Published by Elsevier in Journal of the Formosan Medical Association
- Vol. 113 (11) , 850-856
Erosive potential of soft drinks on human enamel: An in vitro study
- 3 February 2014
- Published by Wiley in International Endodontic Journal
- Vol. 47 (9) , 882-888
Fatigue life enhancement of NiTi rotary endodontic instruments by progressive reciprocating operation
Aim: To evaluate the effect of reciprocating amplitude and progressive angular increment on fatigue life enhancement of NiTi rotary endodontic instruments.Methodology: ProTaper F2 instruments were operated in steel artificial canals with both stationary reciprocating (SR) and progressive reciprocating (PR) motions. The SR motions involved symmetric to and fro reciprocation of ±180o, ±135o, ±90o, ±60o and ±45o. The PR motions were ±45o stationary motion superimposed with angular increments of 7o, 11o, 22.5o or 31o whenever an instrument completed 1, 10 or 30 reciprocating cycles (rc). The fatigue lives were compared with those under continuous rotation (CR) and a reciprocating operation with a forward 144o and backward 72o motion proposed by Yared (2008). The statistical significance of these operating modes on fatigue life was examined using one way anova and post hoc Tukey's tests at P = 0.05. Fractographic analysis was also applied to probe the fracture mechanisms of different rotation motions.Results: Fatigue life increased with decreasing reciprocating amplitude. Operating in the SR increased fatigue life by 355% over that in the CR. Except for the 22.5o increment, all PR motions yielded longer fatigue lives than the SR motion. A progressive reciprocating operation with a ± 45o reciprocating amplitude and a + 7o progressive angular increment every 10 reciprocating cycles (±45o/10rc/+7o) increased fatigue life by 990% over that in the CR motion. In terms of life enhancement over the CR motion, the larger the curvature the less are the differences between different movements. Single crack initiation sites were found in the CR and SR motions, while three crack initiation sites were typical in the ±45o/10rc/+7o motion.Conclusions: Fatigue life increased with decreasing reciprocating amplitude in stationary reciprocation. A progressive reciprocating operation with ±45o/10rc/+7o motion led to significant fatigue life enhancement and multiple fatigue crack initiation in NiTi endodontic instruments.
- 3 February 2014
- Published by Wiley in International Endodontic Journal
- Vol. 47 (9) , 882-888
Fatigue life enhancement of NiTi rotary endodontic instruments by progressive reciprocating operation
Aim: To evaluate the effect of reciprocating amplitude and progressive angular increment on fatigue life enhancement of NiTi rotary endodontic instruments.Methodology: ProTaper F2 instruments were operated in steel artificial canals with both stationary reciprocating (SR) and progressive reciprocating (PR) motions. The SR motions involved symmetric to and fro reciprocation of ±180o, ±135o, ±90o, ±60o and ±45o. The PR motions were ±45o stationary motion superimposed with angular increments of 7o, 11o, 22.5o or 31o whenever an instrument completed 1, 10 or 30 reciprocating cycles (rc). The fatigue lives were compared with those under continuous rotation (CR) and a reciprocating operation with a forward 144o and backward 72o motion proposed by Yared (2008). The statistical significance of these operating modes on fatigue life was examined using one way anova and post hoc Tukey's tests at P = 0.05. Fractographic analysis was also applied to probe the fracture mechanisms of different rotation motions.Results: Fatigue life increased with decreasing reciprocating amplitude. Operating in the SR increased fatigue life by 355% over that in the CR. Except for the 22.5o increment, all PR motions yielded longer fatigue lives than the SR motion. A progressive reciprocating operation with a ± 45o reciprocating amplitude and a + 7o progressive angular increment every 10 reciprocating cycles (±45o/10rc/+7o) increased fatigue life by 990% over that in the CR motion. In terms of life enhancement over the CR motion, the larger the curvature the less are the differences between different movements. Single crack initiation sites were found in the CR and SR motions, while three crack initiation sites were typical in the ±45o/10rc/+7o motion.Conclusions: Fatigue life increased with decreasing reciprocating amplitude in stationary reciprocation. A progressive reciprocating operation with ±45o/10rc/+7o motion led to significant fatigue life enhancement and multiple fatigue crack initiation in NiTi endodontic instruments.