Hiroshi Muramatsu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Hiroshi Muramatsu has a total of 27 co-authors. Here are the top co-authors by number of shared publications:
Sae Ito
School of Bioscience and Biotechnology, Tokyo University of Technology, 1401-1 Katakura, Hachioji, Tokyo 192-0982, Japan
3 shared publicationsAbdullah Hussain A. Alsaleem
Graduate School of Bionics, Computer and Media Sciences, Tokyo University of Technology, Tokyo, Japan
2 shared publications- Egawa
Corporate R & D, Seiko Instruments Inc., Chiba, Japan
1 shared publication Eiji Yuasa
Musashi Institute of Technology
1 shared publicationHao Long
Graduate School of Bionics, Tokyo University of Technology, 1401 Katakura-Machi, Hachioji, Tokyo, 192-0982, Japan
1 shared publication- Jong Min Kim
Aging Research Group, Korea Food Research Institute, Wanju-gun, Jeollabuk-do, South Korea
1 shared publication
Latest Publications
- 22 December 2025
- Published by Springer Nature in Journal of Biological Physics
- Vol. 52 (1) , 2
Difference in cell death response between mitomycin C and 5-fluorouracil treatment studied using quartz crystal microbalance combined with simultaneous monitoring of viable cells
A quartz crystal microbalance (QCM) can be used to evaluate the physical properties of cells exposed to anticancer drugs. Mass-sensing techniques on electrodes detect subtle changes in adherent cells during drug treatment, providing insights into physiological, biochemical, and morphological events from a physical perspective. Although these methods have been established in many studies using living cells, their drug responses remain associated with cell viability. This study aimed to measure QCM response by simultaneously monitoring non-viable cell images. Treatment with mitomycin C (MMC) caused the resonant frequency to shift from a decrease to an increase, followed by a delayed rise in the proportion of non-viable cells. By contrast, treatment with 5-fluorouracil (5-FU) produced minimal frequency changes, accompanied by a shorter delay before cell death was observed. The fitting data to the model equations of the cumulative log-normal distribution curve showed a clear difference in parameter values between MMC and 5-FU, indicating distinct cell death processes. These results demonstrate that QCM-based monitoring of physical properties provides complementary information on drug responses and may serve as a useful tool in anticancer drug development.
- 22 December 2025
- Published by Springer Nature in Journal of Biological Physics
- Vol. 52 (1) , 2
Difference in cell death response between mitomycin C and 5-fluorouracil treatment studied using quartz crystal microbalance combined with simultaneous monitoring of viable cells
A quartz crystal microbalance (QCM) can be used to evaluate the physical properties of cells exposed to anticancer drugs. Mass-sensing techniques on electrodes detect subtle changes in adherent cells during drug treatment, providing insights into physiological, biochemical, and morphological events from a physical perspective. Although these methods have been established in many studies using living cells, their drug responses remain associated with cell viability. This study aimed to measure QCM response by simultaneously monitoring non-viable cell images. Treatment with mitomycin C (MMC) caused the resonant frequency to shift from a decrease to an increase, followed by a delayed rise in the proportion of non-viable cells. By contrast, treatment with 5-fluorouracil (5-FU) produced minimal frequency changes, accompanied by a shorter delay before cell death was observed. The fitting data to the model equations of the cumulative log-normal distribution curve showed a clear difference in parameter values between MMC and 5-FU, indicating distinct cell death processes. These results demonstrate that QCM-based monitoring of physical properties provides complementary information on drug responses and may serve as a useful tool in anticancer drug development.
- 24 April 2021
- Published by Springer Nature in Journal of Biological Physics
- Vol. 47 (2) , 117-129
Comparison of cultured cell attachment on a temperature-responsive polymer, poly-l-lysine, and collagen using modeling curves and a thermal-controlled quartz crystal microbalance
The characteristics of cultured cell attachment onto poly-l-lysine (PLL), collagen, and the thermoresponsive polymer poly(N-isopropylacrylamide) (PNIPAM) were studied using a quartz crystal microbalance (QCM). A QCM with microscope cameras enclosed in a Peltier chamber was developed to enable QCM measurements and microphotographic imaging to be conducted in a temperature-controlled CO2 incubator. Human hepatoma cell line HepG2 cells were cultured on the quartz crystals coated with PLL, collagen, and PNIPAM. Response curves of the resonant frequency of the quartz crystals during the cell attachment process were analyzed on the basis of the parameters of modeling curves fit to the experimentally obtained curves. Analysis of the fitting curves showed that the time constants of the first-lag response were 11 h for PLL, 16 h for collagen, and 38 h for PNIPAM and that the frequency change for the PNIPAM films was six times smaller than those for the PLL and collagen films. These findings were supported by photographic images showing wider cell spread on PLL and collagen than on PNIPAM. The response of cells on PNIPAM was measured during a thermal cycle from 37 to 20 °C to 37 °C. In the resonance frequency–resonance resistance (F–R) diagram, the slopes of ΔR/ΔF corresponding to the cell attachment process and those corresponding to the thermal cycling process differed; the positions in the F–R diagram also shifted to higher resonant frequencies after the thermal cycle. These results suggested that the mass effect decreased as a result of the weakening of the cell attachment strength by the thermal cycle because the molecular brushes of PNIPAM were disarranged.
- 24 April 2021
- Published by Springer Nature in Journal of Biological Physics
- Vol. 47 (2) , 117-129
Comparison of cultured cell attachment on a temperature-responsive polymer, poly-l-lysine, and collagen using modeling curves and a thermal-controlled quartz crystal microbalance
The characteristics of cultured cell attachment onto poly-l-lysine (PLL), collagen, and the thermoresponsive polymer poly(N-isopropylacrylamide) (PNIPAM) were studied using a quartz crystal microbalance (QCM). A QCM with microscope cameras enclosed in a Peltier chamber was developed to enable QCM measurements and microphotographic imaging to be conducted in a temperature-controlled CO2 incubator. Human hepatoma cell line HepG2 cells were cultured on the quartz crystals coated with PLL, collagen, and PNIPAM. Response curves of the resonant frequency of the quartz crystals during the cell attachment process were analyzed on the basis of the parameters of modeling curves fit to the experimentally obtained curves. Analysis of the fitting curves showed that the time constants of the first-lag response were 11 h for PLL, 16 h for collagen, and 38 h for PNIPAM and that the frequency change for the PNIPAM films was six times smaller than those for the PLL and collagen films. These findings were supported by photographic images showing wider cell spread on PLL and collagen than on PNIPAM. The response of cells on PNIPAM was measured during a thermal cycle from 37 to 20 °C to 37 °C. In the resonance frequency–resonance resistance (F–R) diagram, the slopes of ΔR/ΔF corresponding to the cell attachment process and those corresponding to the thermal cycling process differed; the positions in the F–R diagram also shifted to higher resonant frequencies after the thermal cycle. These results suggested that the mass effect decreased as a result of the weakening of the cell attachment strength by the thermal cycle because the molecular brushes of PNIPAM were disarranged.
- 29 April 2020
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 92 (11) , 7907-7914
Monitoring and Modeling of Living Cell Responses in the Attachment Process and Reaction to the Antitumor Reagent Cisplatin Studied by a Quartz Crystal Microbalance Combined with a Microscope
The attachment process and response to an antitumor reagent for cultured cells were monitored with a quartz crystal microbalance (QCM) combined with a microscope. To fit the experimentally obtained curves of the resonant frequency, model equations of resonant frequency curves were built, and parameters of time constants and scale coefficients were determined. For the cell attachment process, a first-order lag response curve well fit the experimental curves. For the response to cisplatin, two response steps were observed in both QCM data and microscopic images, where the cells loosened in the first step and shrank in the second step. Resonant frequency responses for both processes were well fit by two logarithmic normal distribution functions. In addition, the dependence of the resonant frequency change on the cell number was also studied, and a cell–cell interaction model for attached cells was proposed to explain the saturation of the resonant frequency change in high density cell seeding.
- 29 April 2020
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 92 (11) , 7907-7914
Monitoring and Modeling of Living Cell Responses in the Attachment Process and Reaction to the Antitumor Reagent Cisplatin Studied by a Quartz Crystal Microbalance Combined with a Microscope
The attachment process and response to an antitumor reagent for cultured cells were monitored with a quartz crystal microbalance (QCM) combined with a microscope. To fit the experimentally obtained curves of the resonant frequency, model equations of resonant frequency curves were built, and parameters of time constants and scale coefficients were determined. For the cell attachment process, a first-order lag response curve well fit the experimental curves. For the response to cisplatin, two response steps were observed in both QCM data and microscopic images, where the cells loosened in the first step and shrank in the second step. Resonant frequency responses for both processes were well fit by two logarithmic normal distribution functions. In addition, the dependence of the resonant frequency change on the cell number was also studied, and a cell–cell interaction model for attached cells was proposed to explain the saturation of the resonant frequency change in high density cell seeding.
- Open Access
- 29 June 2017
- Published by Springer Nature in Journal of Biological Physics
- Vol. 43 (3) , 355-365
Direct measurement of interaction forces between a platinum dichloride complex and DNA molecules
The interaction forces between a platinum dichloride complex and DNA molecules have been studied using atomic force microscopy (AFM). The platinum dichloride complex, di-dimethylsulfoxide-dichloroplatinum (II) (Pt(DMSO)2Cl2), was immobilized on an AFM probe by coordinating the platinum to two amino groups to form a complex similar to Pt(en)Cl2, which is structurally similar to cisplatin. The retraction forces were measured between the platinum complex and DNA molecules immobilized on mica plates using force curve measurements. The histogram of the retraction force for λ-DNA showed several peaks; the unit retraction force was estimated to be 130 pN for a pulling rate of 60 nm/s. The retraction forces were also measured separately for four single-base DNA oligomers (adenine, guanine, thymine, and cytosine). Retraction forces were frequently observed in the force curves for the DNA oligomers of guanine and adenine. For the guanine DNA oligomer, the most frequent retraction force was slightly lower than but very similar to the retraction force for λ-DNA. A higher retraction force was obtained for the adenine DNA oligomer than for the guanine oligomer. This result is consistent with a higher retraction activation energy of adenine with the Pt complex being than that of guanine because the kinetic rate constant for retraction correlates to exp(FΔx – ΔE) where ΔE is an activation energy, F is an applied force, and Δx is a displacement of distance.
- 29 June 2017
- Published by Springer Nature in Journal of Biological Physics
- Vol. 43 (3) , 355-365
Open AccessDirect measurement of interaction forces between a platinum dichloride complex and DNA molecules
The interaction forces between a platinum dichloride complex and DNA molecules have been studied using atomic force microscopy (AFM). The platinum dichloride complex, di-dimethylsulfoxide-dichloroplatinum (II) (Pt(DMSO)2Cl2), was immobilized on an AFM probe by coordinating the platinum to two amino groups to form a complex similar to Pt(en)Cl2, which is structurally similar to cisplatin. The retraction forces were measured between the platinum complex and DNA molecules immobilized on mica plates using force curve measurements. The histogram of the retraction force for λ-DNA showed several peaks; the unit retraction force was estimated to be 130 pN for a pulling rate of 60 nm/s. The retraction forces were also measured separately for four single-base DNA oligomers (adenine, guanine, thymine, and cytosine). Retraction forces were frequently observed in the force curves for the DNA oligomers of guanine and adenine. For the guanine DNA oligomer, the most frequent retraction force was slightly lower than but very similar to the retraction force for λ-DNA. A higher retraction force was obtained for the adenine DNA oligomer than for the guanine oligomer. This result is consistent with a higher retraction activation energy of adenine with the Pt complex being than that of guanine because the kinetic rate constant for retraction correlates to exp(FΔx – ΔE) where ΔE is an activation energy, F is an applied force, and Δx is a displacement of distance.
- 28 September 2004
- Published by American Chemical Society (ACS) in Nano Letters
- Vol. 4 (11) , 2091-2097
Visualizing a Hybridized PNA Probe on a DNA Molecule with Near-Field Optical Microscopy
- 28 September 2004
- Published by American Chemical Society (ACS) in Nano Letters
- Vol. 4 (11) , 2091-2097
Visualizing a Hybridized PNA Probe on a DNA Molecule with Near-Field Optical Microscopy
- 1 January 2002
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 372 (2) , 314-321
Quartz-crystal sensors for biosensing and chemical analysis
The principle and applications of quartz-crystal sensors based on the three basic concepts for mass, viscosity, and viscoelastic changes are reported. In the general discussion the realization of a resonant frequency–resonant resistance diagram is described in detail. As an example of application to mass sensing, gas sensing with a carbon-coated quartz crystal is reported. Determination of the blood coagulation factor is used as an example of the application to viscosity sensing. As an example of viscoelastic measurement, an ion-exchange polymer-coated quartz crystal is investigated to show that viscoelasticity changes more than mass in the transport process. The possibility of developing new biosensors and chemical sensors is discussed on the basis of these results.
- 1 January 2002
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 372 (2) , 314-321
Quartz-crystal sensors for biosensing and chemical analysis
The principle and applications of quartz-crystal sensors based on the three basic concepts for mass, viscosity, and viscoelastic changes are reported. In the general discussion the realization of a resonant frequency–resonant resistance diagram is described in detail. As an example of application to mass sensing, gas sensing with a carbon-coated quartz crystal is reported. Determination of the blood coagulation factor is used as an example of the application to viscosity sensing. As an example of viscoelastic measurement, an ion-exchange polymer-coated quartz crystal is investigated to show that viscoelasticity changes more than mass in the transport process. The possibility of developing new biosensors and chemical sensors is discussed on the basis of these results.
- Open Access
- 1 January 2001
- Published by Japan Society of Mechanical Engineers in The Proceedings of the Materials and processing conference
- Vol. 2001.9, 439-440
622 Characteristics of Mg Based Composite Material via Solid-State Synthesis
- 1 January 2001
- Published by Japan Society of Mechanical Engineers in The Proceedings of the Materials and processing conference
- Vol. 2001.9, 439-440
Open Access622 Characteristics of Mg Based Composite Material via Solid-State Synthesis
- 1 May 1999
- Published by Wiley in Journal of Microscopy
- Vol. 194 (2-3) , 325-328
High‐speed scanning by dual feedback control in SNOM/AFM
We have developed a high‐speed scanning near‐field optical microscope (SNOM)/atomic force microscope (AFM) system including dual feedback controllers. The system includes an additional piezoelectric actuator with fast response in the z direction and a correction circuit to eliminate unnecessary components from the feedback signal. From the measurement of a patterned chromium layer of 2 × 2 μm2 checks on a quartz glass plate, we confirmed that our system had more effective feedback control and faster scanning than current SNOM/AFM systems that use only a piezo‐tube. The scanning speed of the present system was estimated to be about five times faster than that of current SNOM/AFM systems.
- 1 May 1999
- Published by Wiley in Journal of Microscopy
- Vol. 194 (2-3) , 325-328
High‐speed scanning by dual feedback control in SNOM/AFM
We have developed a high‐speed scanning near‐field optical microscope (SNOM)/atomic force microscope (AFM) system including dual feedback controllers. The system includes an additional piezoelectric actuator with fast response in the z direction and a correction circuit to eliminate unnecessary components from the feedback signal. From the measurement of a patterned chromium layer of 2 × 2 μm2 checks on a quartz glass plate, we confirmed that our system had more effective feedback control and faster scanning than current SNOM/AFM systems that use only a piezo‐tube. The scanning speed of the present system was estimated to be about five times faster than that of current SNOM/AFM systems.
- 1 February 1996
- Published by Elsevier in Thin Solid Films
- Vol. 273 (1-2) , 154-160
Design and application of scanning near-field optical/atomic force microscopy
- 1 February 1996
- Published by Elsevier in Thin Solid Films
- Vol. 273 (1-2) , 154-160
Design and application of scanning near-field optical/atomic force microscopy