Elzbieta Lesniewska
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Elzbieta Lesniewska has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
Regina Rajchert
POLCONTACT‐WARSZAWA ul. Gozdzikow 26 04–231 Warsaw Poland
4 shared publicationsA. Lisowiec
Department of Teleinformation Technology and Electronics, Tele and Radio Research Institute, Warsaw, Poland
2 shared publications- Jan Olak
TRANSFORMEX Limited Liability Company, 04-965 Warsaw, Poland
2 shared publications A. Koszmider
Department of Applied Electrical Engineering & Instrument Transformers, Technical University of Lodz, ul. Stefanowskiego, 18/22, Lodz, 90-924, Poland
1 shared publicationBogdan Tulodziecki
Electric Apparatuses Factory Zwarpol Ltd, Warszawa, Poland
1 shared publication- Daniel Roger
Univ. Artois, UR 4025, Laboratoire Systèmes Électrotechniques et Environnement (LSEE)
1 shared publication
Latest Publications
- Open Access
Problems during the Design and Testing of Instrument, Special and Power Transformers: The Outlook
In 1831, Michael Faraday discovered the phenomenon of electromagnetic induction, which allowed for the construction of previously unknown electrical devices and significantly impacted economic and social development
Open AccessProblems during the Design and Testing of Instrument, Special and Power Transformers: The Outlook
In 1831, Michael Faraday discovered the phenomenon of electromagnetic induction, which allowed for the construction of previously unknown electrical devices and significantly impacted economic and social development
- Open Access
Selection of the Winding Type of Solid-State Transformers in Terms of Transmitting the Greatest Possible Power in the Frequency Range from 500 Hz to 6000 Hz
Solid-state transformer (SST) is an emerging technology that integrates with transformer power electronics converters and control. The most noticeable advantages of SST are the size and weight reduction compared with low-frequency transformers. Since this device is used in many devices such as smart grids, traction systems, systems with renewable energy sources (RESs) and electric vehicle charging devices, it is important to build a high-efficiency device at a low cost. The article evaluates a medium frequency transformer (SST) operating at a frequency of 500 Hz to 6000 Hz with coils wound with aluminum foil or Litz windings and of a grain-oriented electrical steel (GOES) core. The calculations were made using the 3D field method using the numerical finite element method, and the results were compared with the tests of the real model. The measurement method based on the Fourier analysis of real signals was used for the research.
Open AccessSelection of the Winding Type of Solid-State Transformers in Terms of Transmitting the Greatest Possible Power in the Frequency Range from 500 Hz to 6000 Hz
Solid-state transformer (SST) is an emerging technology that integrates with transformer power electronics converters and control. The most noticeable advantages of SST are the size and weight reduction compared with low-frequency transformers. Since this device is used in many devices such as smart grids, traction systems, systems with renewable energy sources (RESs) and electric vehicle charging devices, it is important to build a high-efficiency device at a low cost. The article evaluates a medium frequency transformer (SST) operating at a frequency of 500 Hz to 6000 Hz with coils wound with aluminum foil or Litz windings and of a grain-oriented electrical steel (GOES) core. The calculations were made using the 3D field method using the numerical finite element method, and the results were compared with the tests of the real model. The measurement method based on the Fourier analysis of real signals was used for the research.
- Open Access
Modern Methods of Construction Problem Solving in Designing Various Types of Instrument Transformers
Current and voltage instrument transformers are essential elements of the power system. They work like transformers but do not transmit power. Their task is to accurately transform currents or voltages during system operation, which are then used for measurement and protection. These devices are very precise, and their accuracy is defined by the IEC/CEN standards. Instrument transformers are located at all transformer stations, specialized high-voltage and high-power laboratories, and testing and teaching laboratories. Therefore, the design requirements are very different depending on their type (current, voltage, or combined), function (measuring, protection), and operating voltage (high, medium, and low). The requirements concern not only the operation but also the strength of the insulation system and, sometimes, the mechanical strength.
Open AccessModern Methods of Construction Problem Solving in Designing Various Types of Instrument Transformers
Current and voltage instrument transformers are essential elements of the power system. They work like transformers but do not transmit power. Their task is to accurately transform currents or voltages during system operation, which are then used for measurement and protection. These devices are very precise, and their accuracy is defined by the IEC/CEN standards. Instrument transformers are located at all transformer stations, specialized high-voltage and high-power laboratories, and testing and teaching laboratories. Therefore, the design requirements are very different depending on their type (current, voltage, or combined), function (measuring, protection), and operating voltage (high, medium, and low). The requirements concern not only the operation but also the strength of the insulation system and, sometimes, the mechanical strength.
- Open Access
Analysis of the Operation of Cascade Current Transformers for Measurements of Short-Circuit Currents with a Non-Periodic Component with a Large Time Constant of Its Decay
Simulations of emergency states and tests of resistance of electrical devices to emergencies are performed in specialized high-power laboratories, the so-called short-circuit laboratories. For most electrical power devices, such measurements are required by international standards. The basic equipment of short-circuit testing laboratories consists of current transformers for measuring short-circuit currents. These transformers should not only enable the accurate conversion of sinusoidal currents—which is typical for conventional current transformers, but also asymmetrical short-circuit currents containing an aperiodic component, which classic current transformers cannot reproduce. Therefore, manufacturers and designers try to meet the market demands and design these special class 0.2 current transformers. To meet the high technical requirements, the field-circuit method with three-dimensional space–time analysis of electromagnetic fields was used during design, considering physical phenomena in ferromagnetic cores (i.e., hysteresis and eddy current losses) and the load of the secondary winding of the current transformer by the measurement system. The article presents simulations of secondary currents for the short-circuit current transformer model, and the results were confirmed by measurements and oscillograms of the currents flowing in the windings of the real model. The prototype of the designed short-circuit transformer meets the IEC/EN standard requirements. When measuring harmonic currents, the transformation errors meet the requirements of class 0.2. During the short-circuit current waveforms, the maximum instantaneous peak error does not exceed 1% of the error for all the subsequent maxima of the current waveform during the specified transient switching cycle. In comparison, the standard allows this error to be 10%.
Open AccessAnalysis of the Operation of Cascade Current Transformers for Measurements of Short-Circuit Currents with a Non-Periodic Component with a Large Time Constant of Its Decay
Simulations of emergency states and tests of resistance of electrical devices to emergencies are performed in specialized high-power laboratories, the so-called short-circuit laboratories. For most electrical power devices, such measurements are required by international standards. The basic equipment of short-circuit testing laboratories consists of current transformers for measuring short-circuit currents. These transformers should not only enable the accurate conversion of sinusoidal currents—which is typical for conventional current transformers, but also asymmetrical short-circuit currents containing an aperiodic component, which classic current transformers cannot reproduce. Therefore, manufacturers and designers try to meet the market demands and design these special class 0.2 current transformers. To meet the high technical requirements, the field-circuit method with three-dimensional space–time analysis of electromagnetic fields was used during design, considering physical phenomena in ferromagnetic cores (i.e., hysteresis and eddy current losses) and the load of the secondary winding of the current transformer by the measurement system. The article presents simulations of secondary currents for the short-circuit current transformer model, and the results were confirmed by measurements and oscillograms of the currents flowing in the windings of the real model. The prototype of the designed short-circuit transformer meets the IEC/EN standard requirements. When measuring harmonic currents, the transformation errors meet the requirements of class 0.2. During the short-circuit current waveforms, the maximum instantaneous peak error does not exceed 1% of the error for all the subsequent maxima of the current waveform during the specified transient switching cycle. In comparison, the standard allows this error to be 10%.
- Open Access
Influence of the Selection of the Core Shape and Winding Arrangement on the Accuracy of Current Transformers with Through-Going Primary Cable
The current transformers with split-core are used for installation in places where it is impossible to install classic current transformers. Moreover, this design allows for any measurement location change, and even switching one current transformer into several different shapes of bars or cables. Power network operators, striving for more accurate current measurements, require producers to provide current transformers with a special accuracy class 0.2S. Therefore, manufacturers and designers try to meet the market requirements and, similarly to non-demountable current transformers, i.e., with a toroidal core, design current transformers with split-core class 0.2S. To meet the high metrological requirements, 3D analyses of electromagnetic fields were performed, taking into account physical phenomena and not approximate analytical models. Two types of cores and four different arrangements of the secondary windings of the measuring current transformers were considered. The magnetic field distributions, current error, and phase displacement diagrams of all current transformer models were analyzed, and the model of the transformer structure with the best accuracy was selected. Computations were conducted based on the finite element numerical method, and the results were compared with the real model tests.
Open AccessInfluence of the Selection of the Core Shape and Winding Arrangement on the Accuracy of Current Transformers with Through-Going Primary Cable
The current transformers with split-core are used for installation in places where it is impossible to install classic current transformers. Moreover, this design allows for any measurement location change, and even switching one current transformer into several different shapes of bars or cables. Power network operators, striving for more accurate current measurements, require producers to provide current transformers with a special accuracy class 0.2S. Therefore, manufacturers and designers try to meet the market requirements and, similarly to non-demountable current transformers, i.e., with a toroidal core, design current transformers with split-core class 0.2S. To meet the high metrological requirements, 3D analyses of electromagnetic fields were performed, taking into account physical phenomena and not approximate analytical models. Two types of cores and four different arrangements of the secondary windings of the measuring current transformers were considered. The magnetic field distributions, current error, and phase displacement diagrams of all current transformer models were analyzed, and the model of the transformer structure with the best accuracy was selected. Computations were conducted based on the finite element numerical method, and the results were compared with the real model tests.
- Open Access
3D Electromagnetic Field Analysis Applied to Evaluate the Accuracy of a Voltage Transformer under Distorted Voltage
Voltage transformers (VTs) are an important element of the measuring system that allows measuring the energy flow in medium and high voltage networks. Additional problems with the accuracy of the measurement introduced by the appearance of sources and nonlinear receivers cause deformation of the voltage shape in the energy system. Due to the high metrological requirements, the design of voltage transformers requires high accuracy (for class 0.2 ΔU ≤ 0.2, phase displacement ≤10 min), which is not possible with the use of analytical methods using approximate models. Therefore, only the application of numerical modeling by the finite element method, taking into account real three-dimensional phenomena, allows achieving high modeling accuracy. The article concerns the phenomenon of the influence of voltage higher harmonics of supply voltage on the accuracy (up to the 100th harmonic) of the measuring inductive voltage transformer (IVT). The applied modeling method takes into account the phenomena in the transformer core and the circuit equations resulting from the winding arrangement, which allows for the study of the deformation voltage transformation. Experimental tests on a real model to evaluate the method used were necessary. The article presents simulations for a model transformer, and results have been confirmed by experimental tests.
Open Access3D Electromagnetic Field Analysis Applied to Evaluate the Accuracy of a Voltage Transformer under Distorted Voltage
Voltage transformers (VTs) are an important element of the measuring system that allows measuring the energy flow in medium and high voltage networks. Additional problems with the accuracy of the measurement introduced by the appearance of sources and nonlinear receivers cause deformation of the voltage shape in the energy system. Due to the high metrological requirements, the design of voltage transformers requires high accuracy (for class 0.2 ΔU ≤ 0.2, phase displacement ≤10 min), which is not possible with the use of analytical methods using approximate models. Therefore, only the application of numerical modeling by the finite element method, taking into account real three-dimensional phenomena, allows achieving high modeling accuracy. The article concerns the phenomenon of the influence of voltage higher harmonics of supply voltage on the accuracy (up to the 100th harmonic) of the measuring inductive voltage transformer (IVT). The applied modeling method takes into account the phenomena in the transformer core and the circuit equations resulting from the winding arrangement, which allows for the study of the deformation voltage transformation. Experimental tests on a real model to evaluate the method used were necessary. The article presents simulations for a model transformer, and results have been confirmed by experimental tests.
- Open Access
- 1 September 2019
- Published by Institution of Engineering and Technology (IET) in IET Science, Measurement & Technology
- Vol. 13 (7) , 944-948
Behaviour of measuring current transformers with cores composed from different magnetic materials at non‐rated loads and overcurrents
This research is a continuation of researches into transformation errors of current transformers, when the cores consist of two different magnetic materials at non‐rated loads and overcurrents. Analyses of the electromagnetic field distribution for different secondary winding loads were performed (magnetic field distributions of current transformers, current error and phase displacement diagrams). Computations were conducted based on the finite element numerical method and the results were compared with tests of real‐life models.
- 1 September 2019
- Published by Institution of Engineering and Technology (IET) in IET Science, Measurement & Technology
- Vol. 13 (7) , 944-948
Open AccessBehaviour of measuring current transformers with cores composed from different magnetic materials at non‐rated loads and overcurrents
This research is a continuation of researches into transformation errors of current transformers, when the cores consist of two different magnetic materials at non‐rated loads and overcurrents. Analyses of the electromagnetic field distribution for different secondary winding loads were performed (magnetic field distributions of current transformers, current error and phase displacement diagrams). Computations were conducted based on the finite element numerical method and the results were compared with tests of real‐life models.
- 19 December 2017
- Published by Taylor & Francis
- p. 349-380
Applications of Field Analysis during Design Process of Instrument Transformers
- 19 December 2017
- Published by Taylor & Francis
- p. 349-380
Applications of Field Analysis during Design Process of Instrument Transformers
- 1 September 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 44, 1-2
Influence of different load of the secondary winding on measurement properties of current transformers with core made from different magnetic materials
Results of research on the influence of different load on current transformers' transformation errors when cores consist of two different magnetic materials are presented in this paper. Analyses of the electromagnetic field distribution for different cases of load of the secondary winding were performed (magnetic field distributions of current transformers, current error and phase displacement diagrams). Computations were carried out based on the finite element numerical method and their results were compared with tests of real-life models.
- 1 September 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 44, 1-2
Influence of different load of the secondary winding on measurement properties of current transformers with core made from different magnetic materials
Results of research on the influence of different load on current transformers' transformation errors when cores consist of two different magnetic materials are presented in this paper. Analyses of the electromagnetic field distribution for different cases of load of the secondary winding were performed (magnetic field distributions of current transformers, current error and phase displacement diagrams). Computations were carried out based on the finite element numerical method and their results were compared with tests of real-life models.
- 17 July 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 33 (6) , 2582-2589
Improvement of the Insulation System of Unconventional Combined Instrument Transformer Using 3-D Electric-Field Analysis
This paper presents the new PCB technology medium voltage (MV) combined instrument transformer. The capacitors of the voltage transformer and coils of the current-to-voltage transducers are designed and manufactured using printed circuit board technology. The design of the insulation system of combined transformer was carried out using the electric field analysis. The electric field distributions, computed applying the 3D finite-element numerical method, are presented. The results for several different applications were compared with tests of real-life models.
- 17 July 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 33 (6) , 2582-2589
Improvement of the Insulation System of Unconventional Combined Instrument Transformer Using 3-D Electric-Field Analysis
This paper presents the new PCB technology medium voltage (MV) combined instrument transformer. The capacitors of the voltage transformer and coils of the current-to-voltage transducers are designed and manufactured using printed circuit board technology. The design of the insulation system of combined transformer was carried out using the electric field analysis. The electric field distributions, computed applying the 3D finite-element numerical method, are presented. The results for several different applications were compared with tests of real-life models.